SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

Similar documents
SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT. ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

SEMS & SEMS LIGHT. User s manual. Shielding Effectiveness Measurement System. MPB S.r.l. Via Giacomo Peroni 400/ Rome - Italy

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

Loop & Magnetic Field Coil

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

Chambers Accessories Equipment 1 Equipment 2 Amplifiers Antennas Emission

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 2.8GHz.

Test Systems. VSQ 3000/3002 Reference Radiation Source up to 3GHz

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

RADIOMETRICS Midwest Corporation

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

EMC SHIELDING EFFECTIVENESS TEST REPORT : : :

Advanced Test Equipment Rentals ATEC (2832)

Selective and broadband high frequency field analysis

CS114 + CS115 + CS116

Semi Anechoic Chamber (SAC)

YRS01 York Reference Source

Selective and broadband low frequency field analysis

Regarding RF Isolation for small Enclosures

EMC Precompliance Systems and Accessories Catalog

Selective and broadband low frequency field analysis

EMI Measuring Receiver & Analyzer 10 Hz-3 GHz

Better system sensitivity through preamplifiers

Advanced Test Equipment Rentals ATEC (2832)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Spectrum Analyzers 2680 Series Features & benefits

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

Banska Bystrica Branch. NDB + Marker NARASYS (Navigation Radio-Beacon System)

FM Modulation. Accuracy. Total. Harmonics. Input Range. Frequency. Range. Deviation. Range. Modulation. Accuracy. Audio In Switchable Loads.

Test Instrumentation Range Overview

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

MIL-STD 461F Results for M&A Technology Companion epad Computer

Radiated Spurious Emission Testing. Jari Vikstedt

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

MANUAL. PCD - Precision Conical Dipole Antenna

Todd Hubing. Clemson Vehicular Electronics Laboratory Clemson University

Double-Ridged Waveguide Horn

Measurement of Shielding Effectiveness. Nikhil Jain

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

EMC Accessories Catalog

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Advanced Test Equipment Rentals ATEC (2832) CNE III Comparison Noise Emitter

Trees, vegetation, buildings etc.

Channel 01 (2422MHz)

PMM 9010 PMM 9030 PMM 9060 Fully CISPR-Compliant Digital EMC/EMI receivers 10 Hz 6 GHz

We re In The Business Of Making Your Life Easier

Advanced Test Equipment Rentals ATEC (2832)

Alternative Radiated Emission Test Methods Progress Achieved in IND60 Project

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

E MC Ane c hoi c Chambers

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

ETS Lindgren Anechoic Chamber

Normalized Site Attenuation Test Report

Spectrum Analyzer R&S FS300

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ANSI/NCSL Z & ANSI/NCSL Z540.3

DSA700 Series Spectrum Analyzer

FCC Radio Test Report

Calibration and Validation for Automotive EMC

Accredited Standards Committee C63 - EMC

LUXONDES. See the electromagnetic waves. Product 2018 / 19

RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS

PHALANX INTELEGENT SAFETY SYSTEMS

Coils Loop sensors / radiating loops / Helmholtz coils

System configurations. Main features I SG 64 SOLUTION FOR

Model 3180B Mini-Bicon Antenna User Manual

INSTALLATION AND OPERATING MANUAL

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

Test sites for EMC measurements

SIGFOX END- PRODUCT RADIATED TEST PLAN FOR SIGFOX READY TM CERTIFICATION

ACCREDITED LABORATORY. LIBERTY LABS, INC. Kimballton, IA for technical competence in the field of Calibration

Utilizzo del Time Domain per misure EMI

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

Continuous, remote monitoring and logging of electromagnetic fields

Selecting the right antenna for the

Advanced Test Equipment Rentals ATEC (2832)

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

The Precision Spherical Dipole Source

Test and Measurement for EMC

EMI Pre-Compliance Testing Solution

AK-18G Antenna Kit Operation Manual

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing


Reducing Uncertainty in EMC Measurements

Preliminary features of the SDR-X receiver SDR-X , PowerSDR Winrad Winrad DDS SFDR SFDR AD995 AD99 1

Saturation of Active Loop Antennas

Transcription:

SEMS SHIELDING EFFECTIVENESS MEASUREMENT SYSTEM IN MRI AND SHIELDED ENVIRONMENT ELECTRIC AND MAGNETIC FIELD FROM 10 khz TO 300 MHz*

MRI Shielding Environment (Magnetic Resonance Imaging) Shielded and anechoic environment for EMI/EMC testing Shielded environment with high electromagnetic protection for civil and military applications (Shelter) SEMS SEMS has been conceived and designed to meet the growing test / verification requirements of shielding effectiveness for shielded environments in hospitals and other applications, such as EMI-EMC chamber, military and civil Shelters for telecommunications. SEMS allows great automatic and precise measurement and within a short time to determine the reduction value of the magnetic and electric field in shielded environments.

NOT ONLY SHIELDING EFFECTIVENESS (RAPID, PRECISE AND CORRECT MEASUREMENTS) THERE ARE MANY ADVANTAGES IN USING SEMS INNOVATIVE SYSTEM EXAMPLE OF SETUP: TRADITIONAL SYSTEM CONNECTION Coaxial cables to connect transmitting and receiving antennas. POWER SUPPLY Plug in power supplies needed to supply energy to the instrumental chain of the signal generator/spectrum analyser. DYNAMIC External amplifier to increase the signal strength and, therefore, the measurement dynamic. CONNECTION TO THE PC A PC is required for the automation of the Measurement Test and the subsequent data storage. MEASUREMENT USERS Two users are required to perform measurements. EXAMPLE OF SETUP: SEMS SYSTEM CONNECTION The antennas of the SEMS system are directly connected to the TX and RX units without any cables. POWER SUPPLY The TX and RX units of the SEMS system are equipped with rechargeable batteries with an autonomy of 6 hours. DYNAMIC The TX unit of the SEMS system has a power amplifier covering the whole range up to 300 MHz. CONNECTION TO THE PC SEMS system has a powerful internal CPU that manages independently all the functions of calibration, zero setting and measurement with the respective storing. Data can be downloaded onto a PC via Wireless connection. MEASUREMENT USERS Only one user is required because the system synchronizes itself via Wireless.

SYSTEM DESCRIPTION SEMS Measurement system is made of a TX transmitting unit and a RX receiving unit. Both of them use two pairs of small antennas to measure respectively the attenuation of the magnetic and electric field. TX and RX system covers the whole frequency range from 10 khz to 300 MHz. Obviously, the measurement range being tested is determined by the antenna. In Standard configuration SEMS is equipped with loop antennas for magnetic fields from 2 to 128 MHz and biconical antennas for electric fields from 60 to 300 MHz. Alternatively, two loops for the 10 khz to 4 MHz coverage, two rod antennas for the 1MHz to 60 MHz coverage and two dipole antennas for the 40MHz to 300MHz coverage can be supplied. Contrary to the traditional system, which measures the shielding effectiveness only at a few frequency points, SEMS performs the complete Test continuously on the whole frequency range. A further innovation and development compared to traditional Test systems is the synchronization of the TX and RX units. The two units communicate with each other thanks to a Wireless technology, which is very useful to automate, speed up the test and minimize any user errors. OPERATING PRINCIPLE SEMS measures the shielding effectiveness of a shielded environment, that is the attenuation of the electric and magnetic field that such environment causes. The operating principle is simple: FIRST PHASE OR ZERO SETTING The TX receiving unit generates a RF signal, which is radiated via the antenna. The RX receiver is positioned at a predetermined distance, receives the signal via similar antenna and measures its level in dbm. SECOND PHASE MEASUREMENT Now, if the RX receiver is moved into the environment to be measured, being careful to maintain the same initial distance from the TX unit, a reduction of the measured signal is achieved. The RX unit will show directly the reduction of the environment in db by subtracting the two results measured without the user s intervention. D - ZERO SETTING D - MEASUREMENT SHIELDED ROOM THE ZERO SETTING DISTANCE D MUST BE EQUAL TO THE MEASUREMENT DISTANCE D

SEMS RECEIVER The following concise block diagram represents SEMS receiving part. By following the RF signal coming from the receiving antenna, you find the reduction module, which adjusts the level of the RF signal to the subsequent stages, and the filter modules, which select the bands according to the reception frequency. The RF signal thus adjusted gets into the digital part through a digital analog converter (ADC). Then a RSP and a DSP process the digital signal by using complex algorithms and show it on the display. DIGITAL PART RF IN ADC RSP DSP ATTENUATOR FILTERS DISPLAY SEMS TRASMITTER SEMS transmitting part is briefly represented by the following diagram. The signal to be transmitted is generated by the DDS, following the CPU commands. The CPU receives instructions by the wireless interface of the receiver. This signal is duplicated and amplified to reach the level necessary to the transmitting antenna. DIGITAL PART CPU DDS DOUBLER POWER AMP RF OUT SAME MEASUREMENT, DIFFERENT WAYS Unconnected Mode This function allows to do the measurements in all those enviroment where it s not possible using neither the bluetooth bridge nor the fiber optic cable. The operator will make a list of frequencies with the SEMS Software and upload it on the RX unit from the PC. It s fast and easy. Sniffer Mode Sniffing is an important function for all those technicians that want to mantain the performance of the chamber. Using this operating mode you can find the weak spots in the shielding. Prequiet Mode During the test you will find inside the chamber one or more noisy frequencies. Beore making the measurement, the RX unit can find these frequencies and re-start the test with a new list of frequencies. The new list differs from the former one by few decimal units.

CALIBRATION WITH CAL-KIT SEMS system, while not taking measurements in absolute values, needs a periodic check of its linearity. Cal-Kit meets this requirement simply and precisely. Cal-Kit is supplied with Accreditated Calibration. Calibration procedure can be recalled from the Cal menu. By selecting CalK, the display will show the correct execution step by step. The following pictures show the set-up to be used. STAND ALONE MEASUREMENTS Both SEMS units, TX ed RX, are powered by rechargeable Li-lon batteries. This ensures completely independent measurements without any problem with the industrial mains power supply. Two battery chargers are supplied. USE AND OPERATION OF THE SEMS PC UTILITY SW Thanks to SEMS PC Utility software the measurements recorded on the RX unit can be downloaded, stored and/or exported in ASCII format to write customized measurement reports. Also, zero setting scans can be pre-programmed and then directly transferred to the non-volatile memory of the RX unit.

TECHNICAL SPECIFICATIONS TX/RX Frequency range Resolution RF Output (TX Module) Max output power (typical) RF input (RX module) VSWR Attenuators Max Input Level Dynamics 10 khz...300mhz 10 Hz Z out 50 Ω, N fem. +30 dbm Z in 50 Ω, N fem. < 1.2 0...20dB 110 dbuv 120 db max IF bandwidth (RX Module) 3 db bandwidth 5/150Hz Precision of the attenuation measurement (typical) 10 khz... 30MHz ± 1.0dB 30 MHz...300MHz ± 1.5dB I/0 Interface RS232 / Wireless Acoustic alarm Programmable at the attenuation level Compliance with international standards MIL-Std-285 IEEE Std 299 EN50147-1 NSA65-6 Operating temperature 0... 40 C Battery power supply Rechargeable Li-Ion (6h life) Not replaceable by the user Weight and Dimensions: TX RX Total Weight Rigid case Dimension Antennas Loop Mod. L1 Bi-conical Mod. B1 Set-Up of 0 Calibration & Measurement Options Loop Antennas Mod. L2 Rod Antennas Mod. R1 Dipole Antennas Mod. D1 Wood tripods Mod. TR-02-A Optical Link Mod. LO CalKit 708 g 106x46x194mm 774 g 106x46x194mm 9,4 kg 52 x 43 x 23 cm Frequency range 2...128MHz / Diameter 30cm Frequency range 60...300MHz / Width 35cm Pre-programmable by the user via software Frequency range 10kHz...4MHz / Diameter 30 cm Frequency range 1MHz...60MHz Frequency range 40MHz... 300MHz Adjustable in height 10m 4x 30dB attenuators kit. Specifications may change without prior notice THE SYSTEM INCLUDES Il Sistema SEMS e gli accessori 1) SEMS RX receiver 2) SEMS TX trasmitter 3) 2 biconical antennas Mod. B1 4) 2 loop antennas Mod. L1 5) 2 loop antennas Mod. L2 (Option) 6) 2 dipole antennas Mod. D1 (Option) 7) 2 RS232/wireless 8) 2 AC Adapter/Charger 9) 2.4GHz Active bridge 10) SEMS PC Utility software 11) Rigid case 6 7 1 2 4 10 9 3 11 6 5 8

SEMS 01.12 REVIEW MPB srl Headquarters - Place of Business Via Giacomo Peroni, 400/402 00131 - Rome (Italy) T +39 06 41200744 F +39 06 41200653 www.gruppompb.com info@gruppompb.com