Installation and Operating Instructions for Phase Demodulator Type _.2

Similar documents
Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Installation and Operational Instructions for primeflex -couplings Types 933._33.1 / 933._35.1 / 933._66.1 / 933._67.1

Power supply CP-E 24/0.75

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-T 48/20.0 Primary switch mode power supply

MINI-PS AC/24DC/1.3

Power supply CP-T 48/5.0 Primary switch mode power supply

Instruction manual for STA 1 sectional door operator

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 12/2.1

QUINT-PS AC/24DC/40

Power supply CP-E 24/2.5

Power supply CP-D 24/1.3

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 3AC/24DC/10

Instruction manual for STA 1 sectional door operator

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Switching power supplies CP range, Linear power supplies CP-L range. Content

Operating instructions Fail-safe delay timer AZS About this document. Content

User and Safety Manual ProLine P224xx P1

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

SEPARATOR P20G TYPE USER S MANUAL

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

MINI-PS AC/2X15DC/1

Industrial motor controller for brushed DC motors 24 VDC

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Type CP-S, CP-C & CP-A Switch mode

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

QUINT-PS-24DC/24DC/10

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

EC 45 flat with integrated electronics Document ID: en Operating Manual

E-STOP relays, safety gate monitors

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

CP-T range Product group picture

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Industrial motor controller for brushed DC motors 24 VDC

Safety switches with slotted hole lever

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Power Supplies 3. SDN-C Compact DIN Rail Series

Proportional amplifier type EV22K5

AMM-1022 Digital Multimeter USER`S MANUAL

CP-T range Benefits and advantages

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Analogue Demo Multimeter ADM

02/11/2015

External brake resistor AX2090-BW5x

Electronic timer CT-TGD.22

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

MINI MCR-SL-UI-I-LP-NC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

OPTITEMP TT 10 C/R Technical Datasheet

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

MAVOWATT 4 Multifunction Power Meter

Electronic timer CT-SDD.22

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

3B SCIENTIFIC PHYSICS

Industrial motor controller for brushed DC motors 12 VDC

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

DISCRETE INPUT MODULE, 16 points

PHOENIX CONTACT - 09/2009

3B SCIENTIFIC PHYSICS

Primary switch mode power supplies Product group picture

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Operating Instructions

Reliable control of DC consumers

Level Switch NRS 2-50 NRS Original Installation Instructions English

PRetrans Table of contents

MINI MCR-SL-UI-f(-SP)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

E-STOP relays, safety gate monitors

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Operating Instructions

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

3 line sine wave EMC output filters for converters and power electronics

Liquid level monitoring relay CM-ENS.2x

05/09/2012

High precision measurement system for current and voltage IHC-A/B-RM01/03

Transcription:

Guidelines on the Declaration of Conformity A conformity evaluation has been carried out for the product in terms of the EU Low Voltage Directive 2014/35/EU and the Electromagnetic Compatibility (EMC) Directive 2014/30/EU. The Declaration of Conformity is laid out in writing in a separate document and can be requested if required. Guidelines on the EMC Directive (2014/30/EU) The product cannot be operated independently according to the EMC directive. Only after integration of the product into an overall system can this be evaluated in terms of the EMC. For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions, but not in the overall system. Guidelines on the Machinery Directive (2006/42/EC) The product is a component for installation into machines according to the machinery directive 2006/42/EC. The product can fulfil the specifications for safety-related applications in coordination with other elements. The type and scope of the required measures result from the machine risk analysis. The product then becomes a machine component and the machine manufacturer assesses the conformity of the safety device to the directive. It is forbidden to start use of the product until you have ensured that the machine accords with the regulations stated in the directive. Guidelines on the ATEX Directive Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger of explosion. For application of this product in areas where there is a high danger of explosion, it must be classified and marked according to directive 2014/34/EU. Safety and Guideline Signs General Safety Guidelines Immediate and impending danger, which can lead to severe physical injuries or to death. Danger of death! Do not touch carrying lines and components. CAUTION Danger of injury to personnel and damage to machines. Danger of burns when touching hot surfaces Guidelines on important points. CAUTION Danger from devices caused by shortcircuits and earth short-circuits at the terminals Electronic devices cannot be guaranteed fail-safe. General Safety Guidelines During the risk assessment required when designing the machine or system, the dangers involved must be evaluated and removed by taking appropriate protective measures. To prevent injury or damage, only professionals and specialists are allowed to work on the devices. They must be familiar with the dimensioning, transport, installation, initial operation, maintenance and disposal according to the relevant standards and regulations. Only carry out installation, maintenance and repairs in a de-energised, disengaged state and secure the system against inadvertent switch-on. Before product installation and initial operation, please read the Installation and Operational Instructions carefully and observe the Safety Regulations. Incorrect operation can cause injury or damage. Page 1 of 5

Application s are used to connect DC units to alternating supplies. Due to automatic switching from the applied overexcitation to the holding, it is possible to energise brakes for shorter switching times with overexcitation and to reduce power dissipation after the armature disk has attracted. s are not suitable for all applications, e.g. use of the phase demodulator when operating noisedamped brakes is not possible. The product s suitability should be checked before use. Function The phase demodulator is used for an input of 230 VAC or 400 VAC. The coil is energised after the input is switched on using overexcitation. After the overexcitation time, the unit switches automatically to the holding. Dimensions (mm) 64 17,5 Apart from this, the phase demodulator has an integrated automatic DC-side disconnection. In contrast to the usual DC-side disconnection, no further protective measures or external components are required. The DC-side disconnection is activated as a standard measure (terminals 3 and 4 are not wired) and causes short switching times on the electromagnetic consumer. 48,6 15 5,6 The integrated automatic DC-side disconnection can be deactivated by fitting a bridge between the terminals 3 and 4. The coil is de-energised via an internal freewheeling diode. This has the advantages of soft brakings and quieter switching noises. However, this substantially lengthens the switching times (approx. 6 10x). 30 4,5 54 5 9 Accessories: Mounting bracket set for 35 mm rail acc. EN 60715: Article No. 1802911 Electrical Connection (Terminals) 1 + 2 Input 3 + 4 Deactivation of integrated automatic DC-side disconnection Ø4,5 9 54 5 + 6 Output Page 2 of 5 Your reliable partner

Technical Data Type Input Output Size 1 2 012.000.2 012.001.2 012.002.2 012.003.2 012.005.2 012.001.2 SO SO SO SO SO ± 10% U I [VAC] 230 230 230 230 230 400 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 60 Hz 50 Hz Holding ± 35% [VDC] 52 52 52 90 63 38 50 Hz 60 Hz 104 Overexcitation ± 35% [VDC] 190 190 190 190 190 330 Overexcitation time ± 20% t over [ms] 150 700 30 Output current at 45 C I RMS [A] 1 1 1 1 1 1 Max. coil power P [W] 130 130 130 130 130 155 Max. switching frequency [1/min] 120 10 10 120 10 10 Device fuses FF 5 A (H) 5 x 20 mm Protection IP65 components IP20 terminals Terminals Nominal cross-section 1.5 mm 2 (AWG 22-14), screws M3, max. tightening torque 0.5 Nm Ambient temperature [ C] -25 to +85 Storage temperature [ C] -40 to +85 Conformity markings FF 4 A (H) 6.3 x 32 mm Installation conditions The installation position can be user-defined. Please ensure sufficient heat dissipation and air convection! Do not install near to sources of intense heat! Special designs with other input and output s as well as longer overexcitation times are available on request! Wiring Example (400 VAC, DC-side switching) L1 L2 L3 Wiring Example (230 VAC, AC-side switching) L1 L2 L3 N Output 104VDC 400 Overexcitation 330VDC/ms Max. switching time 10 cycles/min. Coil Please observe installation and operation instructions! 2/012.001.2SO Output 52VDC Overexcitation 190VDC/150ms Max. switching time 2 cycles/min. Coil Please observe installation and operation instructions! M 3 ~ M 3 ~ Page 3 of 5

Switch-ON Switch-on always takes place AC-side, as only then is the overexcitation activated. Switch-OFF If a longer brake engagement time or a quieter switching noise is required, please switch AC-side. For this, a bridge must be installed between terminals 3 and 4. Device Fuses If short switching times are required, please switch DC-side. To protect against damage from short-circuits or earth short-circuits, please add suitable device fuses to the mains cable. Short-circuits or earth short-circuits can lead to phase demodulator failures. After fuse elements have reacted to a malfunction, the phase demodulator must be checked for functional and operational safety (overexcitation, switch-off, response delay time, holding ). The same procedure is to be carried out after coil failure. Coil Capacity Calculations: P nom P hold P nom The coil capacity must not be larger than P nom or the nominal current I RMS which flows through the phase demodulator must not be exceeded, as otherwise the coil and the phase demodulator can fail due to thermic overload. [W] RMS coil capacity dependent on switching frequency, overexcitation, reduction in capacity and duty cycle x t over + P hold x t hold = t tot. [W] Coil nominal capacity (catalogue values, Type tag) [W] Coil capacity on overexcitation = ( )² x P nom [W] Coil capacity at reduced capacity Overexcitation time t over P hold = ( )² x P nom Increased wear (enlarged air gap) as well as coil heat-up lengthen the brake separation time t 2. Therefore, when dimensioning the overexcitation time t over, please select at least double the separation time t 2 on each brake Type and size (catalogue values). Recovery Time 50 ms The recovery time is the time the phase demodulator requires in order to reach its starting position after switch-off. Therefore, the input may be switched on again at the earliest after 50 ms. During cycle operation, please take suitable measures to ensure that the recovery time of 50 ms is kept to. Maximum Output Current t over [s] Overexcitation time t hold [s] Time of operation with reduction in capacity t off [s] Time without t tot [s] Total time (t over + t hold + t off ) [V] Overexcitation [V] Holding [V] Coil nominal I eff [A] RMS current, dependent on switching frequency, overexcitation time and duty cycle I RMS = Time Diagram: U x P nom ² t on t tot. t off RMS coil current [A] Load diagram for Phase Demodulator 1,1 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0-40 -20 0 20 40 60 80 100 Temperature [ C] 0 t over t hold t Page 4 of 5 Your reliable partner

EMC-compatible Installation The measure described for compliance with the EMC directive is examined under laboratory conditions. It can not be transferred obligatorily to the condition of a machine or equipment due to deviations. The inspection tests the individual components mayr -phase demodulator and the mayr -brake and is applicable for an input of 230 VAC. Standards Product standard VDE 0160 / DIN EN 50178:1998-04 Electronic equipment for use in power installations EMC inspections EN 61000-6-2:2006-03 EN 61000-6-4:2007-09 Interference immunity Interference emission L N PE line filter Ferrite Insulation coordination acc. VDE 0110 / EN 60664:2008-01 Over category III Pollution degree 1 Rated insulation 400 V RMS Output 52VDC Overexcitation 190VDC/150ms Max. switching time 2 cycles/min. Coil Please observe installation and operation instructions! Measure Installation of a line filter in the AC-supply line (e. g. Epcos B84112-B-B30) Installation of a snap ferrite (e. g. Würth 74271221) or of a ferrite sleeve (e. g. Würth 74270090) with a three line cable feedthrough in the brake cable Please mount the line filter, snap ferrite or ferrite sleeve directly onto the phase demodulator! Intended Use mayr -rectifiers have been developed, manufactured and tested as electronic equipment in compliance with the DIN EN 50178 standard and in accordance with the EU Low Voltage Directive. During installation, operation and maintenance of the product, the requirements for the standard must be observed. mayr -rectifiers are for use in machines, systems and devices and must only be used in the situations for which they are ordered and confirmed. The products are designed for installation into electrical control cabinets and terminal boxes. Using them for any other purpose is not allowed. Avoid an antennae effect: Keep the supply cables as short as possible; do not form rings or loops with the cables! Mount good earth connections onto the metal body of the brake! Lay control cables separately from power cables or from strongly pulsating supply cables! During operation with a frequency converter, please ensure EMC-compatible installation of the frequency converter! Please always check the holding of the phase demodulator during operation of all components in the system! Page 5 of 5