Technische Universität Chemnitz Physikalische Chemie. Laser Safety

Similar documents
Laser Safety & the Human Eye Recall the human eye is a simple single lens system Crystalline lens provide focus Cornea: outer surface protection

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

RENISHAW INVIA RAMAN SPECTROMETER

The Safe Use of Lasers. in Clinical Practice

Spectroscopy Application: Using Raman Spectroscopy to Detect Art Forgeries Detecting art forgeries using Raman spectroscopy

NDFG Non-collinear difference frequency generator

Operating Instructions GEMINI R

Manufacturing Metrology Team

Laser processing of materials. Laser safety

Standard Operating Procedure

RENISHAW RAMAN MICROSCOPE STANDARD OPERATING PROCEDURE

Series 48 Air Cooled Laser & UC-2000 Quick Start Guide

How to align your laser for two-photon imaging

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

Bruker Dimension Icon AFM Quick User s Guide

Instructions for the Experiment

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

X-Laser X-BEAM 5000 FEILD SERVICE ALIGNMENT GUIDE

Chapter 23 Study Questions Name: Class:

Bruker Dimension Icon AFM Quick User s Guide

Upcoming Changes in the ANSI Z136.1 Standard - Safe Use of Lasers

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

OPTICS DIVISION B. School/#: Names:

Firestar v Series air cooled laser & Flyer 3D System Quick Start Guide

Winter College on Optics: Trends in Laser Development and Multidisciplinary Applications to Science and Industry February 2013

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Optics looks at the properties and behaviour of light!

Renishaw InVia Raman microscope

Multi-application platform for education & training purposes in photonical measurement engineering & quality assurance with image processing

VIP User manual English

LASER RADIATION REQUIREMENTS

Lecture 1 1 Light Rays, Images, and Shadows

TABLE OF CONTENTS. References

KTP LASER. Photocoagulation System

SINGLE-MODE LASER DIODES. Chip on Submount, QA-Mount. Laser Diodes

Fluke 570 Series Infrared Thermometers:

Photonic-based spectral reflectance sensor for ground-based plant detection and weed discrimination

X-SCOPE Ultra large FOV micro video colorimeter

Diode Pointer Quick Start Guide

L20 - Solve Your Application Challenges with New Sensing Solutions Hands-On Lab For Classroom Use Only!

PiXL Independence: GCSE Physics Student Booklet KS4. I. Level 1- Multiple Choice Quiz 20 credits. Level 3 - Science in The News 100 credits

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

Pulstar p100/150 water cooled laser & Flyer 3D System Quick Start Guide

Color Video Projector

Life Science Chapter 2 Study Guide

General Safety Awareness

Physics Learning Guide Name:

National 3 Physics Waves and Radiation. 1. Wave Properties

Operating Instructions for ISSI Series LM2X, LM2X-DM, LM2X-DMHP

USING LASER POWER METER

Diode Pointer Quick Start Guide

Improving the Collection Efficiency of Raman Scattering

Practical work no. 3: Confocal Live Cell Microscopy

Beaming Optical Length Tester (BOLT)

WITec Alpha 300R Quick Operation Summary October 2018

Wave optics and interferometry

Science 8 Unit 2 Pack:

Name: Date: Block: Light Unit Study Guide Matching Match the correct definition to each term. 1. Waves

As the manufacturing world becomes more and more automated, industrial sensors have become the

Introduction to the operating principles of the HyperFine spectrometer

How-to guide. Working with a pre-assembled THz system

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

1. Diffuse sensor, intensity difference 2. Diffuse sensor with background suppression 3. Retro-reflective sensor with polarization filter 4.

Supplementary Materials

LASERS. & Protective Glasses. Your guide to Lasers and the Glasses you need to wear for protection.

Development and Applications of a Sample Compartment FTIR Microscope

Guide to Operating the Bruker FT-IR Microscope I. Basic Spectrum Acquisition with Vertex 70

Firestar f201 laser & Flyer 3D System Quick Start Guide

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

Basic concepts. Optical Sources (b) Optical Sources (a) Requirements for light sources (b) Requirements for light sources (a)

Reflection Teacher Notes

Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

YOUNGS MODULUS BY UNIFORM & NON UNIFORM BENDING OF A BEAM

EXAMINER+ Manual V.1. ARROWHEAD FORENSICS Strang Line Road Lenexa, Kansas PHONE FAX

3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.

improved stability (compared with

ID: A. Optics Review Package Answer Section TRUE/FALSE

Verizon NEBS Compliance and Quality Assurance (NQA) Labeling Requirements for Light Emitting Products

Radial Polarization Converter With LC Driver USER MANUAL

CONFOCAL MICROSCOPE CM-1

Unit Two Part II MICROSCOPY

Working with the BCC Cube Filter

Lecture Notes Prepared by Prof. J. Francis Spring Remote Sensing Instruments

CDRH 21 CFR Part 1040 Informative Laser Report

PGx11 series. Transform Limited Broadly Tunable Picosecond OPA APPLICATIONS. Available models

Firestar f201 laser & Flyer 3D System Quick Start Guide

Tapered Amplifiers. For Amplification of Seed Sources or for External Cavity Laser Setups. 750 nm to 1070 nm COHERENT.COM DILAS.

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

LH Series Sensor Configurator Software User Manual rev. D 1/11/2012

University of MN, Minnesota Nano Center Standard Operating Procedure

(Refer Slide Time: 00:10)

Description of options, upgrades and accessories for the laser beam stabilization system Compact

An Activity in Computed Tomography

Transmission of light - The Ray Model of Light

Microscopic Structures

Transcription:

Technische Universität Chemnitz Physikalische Chemie Laser Safety.

Lasers and laser systems are classified by their ability to cause biological damage to the eye or skin during use. Class I: Lasers or laser systems incapable of producing damaging radiation during intended use. Class II: Lasers emitting radiation in the visible portion of the spectrum. The power of these lasers is such that they will normally be protected by a physiological aversion response (blink reflex), However, this is not reliable. Thus, personnel has to wear laser eyewear for protection. In case of class II lasers, the maximum permissible exposure limits can be exceeded if the beam is viewed directly for extended periods. Class III Lasers that produce radiation that cause eye damage when viewed directly, or when a specular reflection is viewed. A diffuse reflection is usually not a hazard. Class IV Lasers that produce radiation that may be dangerous to the eye even when viewing a diffuse reflection. The direct beam can produce skin damage and can also be a fire hazard. In our group we have two instruments (FTIR-Spectrometer, Raman microscope) which contain Class II lasers. In normal operation these lasers are contained within the housing of the instrument. The most severe danger of damage to Your eyes stems from the atomic force microscope in 007/h. This instruments utilizes an invisible class III laser to measure the deflection of the afm-tip. This laser exits the scanner at the centre of the scanning unit. In normal operation the scanner is positioned on his three legs onto a horizontal surface. In this case the Laser hits this surface at close distance in almost in vertical incidence. In normal operation You have to switch on the laser actively via the computer control, there is a indicator light on the scanner that is lit when the laser is on. Switch the laser on only when You need it for Your measurements. Switch it off immediately when it is not needed any more. invisible laser radiation If the surface below the tip is non reflecting and IR-opaque, operation is safe. Be careful if the scanner is positioned onto a reflecting surface or onto a surface bearing reflecting objects or spots, reflected light might case damage to Your eyes. Be careful concerning reflecting objects on Yourself: reflecting jewellery and decoration like wedding rings, wristwatches, buttons cufflinks has to be taken off.

If the scanner is positioned on the microscope stage, be aware of the fact that the laser radiates directly into the optical system. Without safety filter, it would be focussed through the ocular directly into Your eyes. To prevent this from happening there is a safety filter (Schott BG39) installed preceding the ocular. Do never remove this safety filter. Do not use the microscope in combination with the afm, if the seal at the side of the microscope is broken Do not operate the afm on any other microscope that lacks this safety filter In here is the protective filter Do not operate the AFM If this seal is broken

The safety filter is placed immediately preceding the ocular. It does not affect the front or side ports of the microscope. Do not open the front or the side ports when the laser is on. The side port at the right side currently is used for the camera. This camera is sensitive to visible and infrared light and is beside others needed to visualize the laser for alignment. If You detach the camera for service, be aware that You open a port for the laser light. Do not open these ports Do not detach the camera while the afm is on invisible laser radiation The scanner has an electronic orientation sensor. The laser is on when the scanner has horizontal orientation, it is automatically interrupted when the scanner is tilted out of the horizontal orientation- However it is again on, when the scanner is upside down! This safety feature can be disabled within the controlling software by an appropriate direct command! Detach the scanner from the cables before You turn it upside down Do not disable the orientation dependent safety switch. [strictly forbidden at any time! by the head of the group]. Do not position the scanner in such a way that the laser is pointing towards the room or people even if the scanner is expected to be shut off.