Digital Input Output Module for Zone 1 Series 9470/32

Similar documents
Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Temperature Input Module for Zone 1 Series 9482/32

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Remote I/O. 74 Remote I/O. Remote I/O System

Binary Output without Power Supply Series 9176

Binary Output Series 9175

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1.

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolating Repeater Input Series 9163

Isolators A3/1. Vibration Transducer Supply Unit Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Fieldbus Isolating Repeater Series 9185/11

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Digital I/O Coupler (4-wire) Series 9413/21

Two-channel safety barriers Series 9002

Isolators A3/1.

Two-channel safety barriers Series 9002

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers Series 9001

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Inductive sensor slot-type SI2-K08-AP7

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Technical Data. General specifications. Rated operating distance s n 3 mm

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Signal Beacon - LED Series 6162

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Field indicator for current loops with HART communication Models DIH50, DIH52

Rail mounted Temperature Transmitter TH102/TH102-Ex

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

onlinecomponents.com

Field indicator for current loops with HART communication Models DIH50, DIH52

Actuators Series 8602/3

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Assembly. Front view. Switch Power Rail

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Head mounted Temperature Transmitter TF02/TF02-Ex

Safety Instructions Nivotester FTC625, FTC325

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Control Unit Series 8208

Assembly. Front view. Parametrization interface. Power Bus

PRetrans Table of contents

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Temperature transmitter itemp PCP DIN rail TMT 121

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Assembly. Front view. Switch Power Rail

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Motor Protection Circuit Breaker Series 8146/5-V27

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Positioner with HART Communication Type 3780

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Technical Information Barrier RB223

Rotary Measuring Technology

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Temperature Transmitter itemp RTD DIN rail TMT 127

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Rudder or propeller angular position transmitter KINAX WT720

SINEAX TV809, 1 channel Programmable Isolating Amplifier

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

A6500-UM Universal Measurement Card

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

0 2 1 â Ó. itemp HART TMT182. Technical Information

General Specifications

0 2 1 â Ó. itemp HART TMT182. Technical Information

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Overcurrent Protection / 7SJ45

MACX MCR-EX-SL-RPSSI-I

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

SINEAX B 811 Power Pack with additional Functions

FLEX Ex Power Supplies

Technical Information RMA42

Transcription:

www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used as frequency/counter input; with rotation direction recognition > Line fault monitoring and LED display per channel > Diagnostics based on NE107 > Module can be replaced in the hazardous area under power (hot swap) 15232E00 The Digital Input Output Module is used for connecting of up to 16 intrinsically safe digital signals to the IS1 Remote I/O system. All can be parameterised in pairs as input for connection of passive contacts or NAMUR proximity switches (EN 60947-5-6) or as output for connection of low power solenoid valves. Up to 8 inputs can be used as frequency inputs or counters up to 20 khz, in operating mode "Rotation direction recognition" and "Forward/backward counter" up to 4 inputs. The Ex i inputs or outputs are short-circuit proof and galvanically separated from the system. Compatible spare for IS1 I/O modules: Series 9470/12, 9470/22, 9475/12-08-41 ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex interface x x x x x x Ex interface x x x x x x Ex interface x x x x x x Installation in x x x x Installation in x x x x Installation in x x x x x x WebCode 9470C Remote I/O /1

Explosion Protection Global (IECEx) Gas and dust IECEx DEK 12.0044X Ex ia [ia Ga] IIC T4 Gb [Ex ia Da] IIIC Europe (ATEX) Gas and dust DEKRA 12ATEX0099X E II 2 (1) G Ex ia [ia Ga] IIC T4 Gb Certifications and certificates Certificates Ship approval Further parameters Installation Further information Safety data Max. voltage U o Max. internal inductance L i 1 channel Max. current I o Max. power P o Max. internal capacity C i Max. connectable inductance L o/capacity C o IIC E II (1) D [Ex ia Da] IIIC ATEX, IECEx, Brazil (INMETRO), India (PESO), Canada (cfm), Kazakhstan (TR), Russia (TR), Serbia (SRPS), USA (FM), Belarus (TR) ABS, CCS, ClassNK, DNVGL, LR, RINA, RS, BV in Zone 1, Zone 2, Zone 21, Zone 22 and in the safe area for further interconnections (4, 8 or 16 ), see operating instructions and certificates 9.8 V negligible 10.4 ma 25.5 mw 2.5 nf L o [mh] 280 100 50 20 10 5 2 1 0.5 0.2 0.1 0.02 C o [μf] 0.49 0.56 0.64 0.72 0.81 0.96 1.1 1.3 1.6 2 3.3 IIB/IIIC L o [mh] 1000 100 50 20 10 5 2 1 0.5 0.2 0.1 0.01 C o [μf] 2.6 2.8 3.3 3.7 4.2 5.1 6 7.2 9.3 12 23 2 in parallel Max. current I o Max. power P o Max. internal capacity C i Max. connectable inductance L o/ capacity C o IIC 20.8 ma 51 mw 5 nf L o [mh] 100 50 20 10 5 2 1 0.5 0.2 0.1 0.02 C o [μf] 0.3 0.44 0.57 0.67 0.77 0.93 1.1 1.3 1.6 2 3.3 IIB/IIIC L o [mh] 270 100 50 20 10 5 2 1 0.5 0.2 0.1 0.01 C o [μf] 2.3 2.6 3.1 3.6 4.1 5.1 6 7.2 9.3 12 23 Selection Table Version Description Installation Order number Weight kg Digital Input Output Module Note 16 with adjustable parameters for contacts, NAMUR proximity switches or low-power solenoid valves, with channel status LEDs Zone 1 9470/32-16-11 0.275 Please order 2 terminals separately - see Accessories /2 Remote I/O

Technical Data Electrical data Ex i inputs/outputs Number of Inputs Min. input signal ON Max. input signal OFF Operating point Supply voltage Internal resistance Signal Frequency input Max. switching frequency Min. pulse width 16 (in pairs with adjustable parameters as input or output) 16 2.1 ma 1.2 ma 1.65 ma 8.2 V 1 kω EN 60947-5-6 (NAMUR) 8 20 khz (at frequencies > 1 khz the maximum conductor length is reduced, e.g. at 5 khz to approx. 75 m) 25 μs Measuring range 0.1 600 Hz 1 Hz 3 khz* 1 Hz 20 khz Resolution 0.01 Hz 0.05 Hz 0.5 Hz Accuracy 0.1 % 0.1 % 0.1 % Counter Counting range Rotation direction recognition, forward/ backward counter Function Resolution Outputs Application Open-circuit voltage Max. output current Internal resistance Rated operation Output characteristic 8 0... 65535 als UINT16 4 (each two inputs switched in parallel) Up/down counter; Frequency with direction 16 bit / 32 bit 16 Ex i low-power solenoid valves 8.2 V 8.2 ma 1 kω 6 V / 2 ma U[V] 9470/3. - Output 8 7 6 5 4 3 2 1 0 0 2 4 6 8 I[mA] * Default 15284E00 Remote I/O /3

Technical Data Electrical data Ex i inputs/outputs Signal transmission Max. delay from signal / internal bus Max. delay from frequency input / internal bus < 1 ms Filter without small medium large Frequency 0.1 Hz ( f < 1 Hz 1/f + 1 ms 2/f 3/f 6/f 1 Hz ( f < 10 Hz 1/f + 1 ms 4/f 9/f 18/f 10 Hz ( f < 100 Hz 1/f + 1 ms 8/f 27/f 54/f 100 Hz ( f < 1 khz 1/f + 1 ms 16/f 81/f 162/f 1 khz ( f < 1960 Hz 1.5 ms 32/f 243/f 486/f 1960 Hz ( f < 10 khz 1.5 ms 16.5 ms 124 ms 248 ms 10 khz ( f < 20 khz 1.5 ms 33 ms 372 ms 744 ms f ) 20 khz 1.5 ms 66 ms 372 ms 744 ms Galvanic separation Test voltage acc. to standard EN 60079-11 Between auxiliary ) 1500 V AC power / system components Between two ) 500 V AC I/O modules Between ) 500 V AC I/O / system components Between ) 500 V AC I/O / ground (PA) The inputs of an I/O module have a common negative conductor. Electromagnetic compatibility Geprüft nach folgenden Normen und Vorschriften: EN 61326-1 IEC 61000-4-1 6, NAMUR NE 21 Electrical connection Power supply BusRail Types 9494 Ex i field signals Pluggable, blue terminals, 16-pole, 2.5 mm 2, screw- or spring-type versions with lock Auxiliary power Version Intrinsically safe Ex ia via BusRail Max. current 120 ma consumption Max. power 2.5 W consumption Max. power dissipation 2.5 W Device-specific data Settings Module Diagnostics ON / OFF message Signal Signal type Input / output*) Pulse extension / 0 s / off; 0.6 s / small; 1.2 s / medium; 2.4 s / large *) frequency filter Inverting input/ normal / inverted*) output Line fault ON / OFF monitoring Behaviour in case Replacement value '0'; replacement value '1'; hold (initial value 0); hold (initial value 1) of error /4 Remote I/O

Technical Data Device-specific data Settings Signal Operating mode counter/frequency Counter control Counting event Counter 16 bit; 0.1... 600 Hz; 1 Hz... 3 khz; 1 Hz... 20 khz; 1 Hz... 20 khz with direction; up/down counter 16 bit; up/down counter 32 bit*) Run, Stop, Reset positive slope; negative slope*) *) setting is made for channel pairs Ambient conditions Ambient temperature -40 +75 C Storage temperature -40 +80 C Maximum relative 95 % (without condensation) humidity Use at the height of < 2000 m Semi-sinusoidal shock 15 g (3 shocks per axis and direction) (IEC EN 60068-2-27) Sinusoidal vibration (IEC EN 60068-2-6) Mechanical data Degree of protection (IEC 60529) Module enclosure Fire resistance (UL 94) Pollutant class Dimensions Indication LED indication Module requires maintenance Operating state Group error Channel error Channel status Function indication Retrievable parameters Error indication Module status and alarms Signal errors for each channel Signal status bit Wire breakage input/output Short circuit input/ output 1 g in the frequency range 10... 500 Hz 2 g in the frequency range 45... 100 Hz IP20 polyamide 6GF V2 corresponds to G3 L = 128 mm, W = 96.5 mm, H = 67 mm LED "M/S", blue LED "RUN", green LED "ERR", red LED red, for each channel LED yellow, for each channel Manufacturer, Type, hardware revision, software revision, serial number Internal bus error primer / redundant No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance "0" = signal disturbed; "1" = signal valid < 50 μa < 100 Ω Note: Contacts require circuitry with 1.2 kω in series and 15 kω in parallel for wire breakage/short-circuit detection. For outputs, wire breakage/short-circuit detection is only possible in the ON state. Mounting / Installation Mounting orientation horizontal or vertical (observe operating instructions) Mounting type on 35 mm DIN rail NS 35/15 (DIN EN 60715) Remote I/O /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 98 [3,86] 96,5 [3,8] 68 [2,68] 64 [2,52] 70 [2,76] 128,5 [5,06] 15254E00 9470/32 Accessories and Spare Parts Designation Figure Description Art. no. Pluggable terminal LED indicating lamp Model 8010/C1661 02079E00 02077E00 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, screw connector, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits Labelling: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 1... 16 Attention: An additional terminal is necessary for I/O module Series 9470 and 9480. Designation: 17... 32 2.5 mm 2 with lock, 16-pole, spring clamp connection, blue, for connecting the field signals to I/O modules, for intrinsically safe field circuits, incl. test jacks Labelling: 17... 32 single electrical equipment for intrinsically safe circuits according to EN 60079-11 162702 162718 162695 162716 228026 Labelling strips 11403E00 "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 DIN sheet 05869E00 For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 Partition 09900E00 For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance 220101 15196E00 /6 Remote I/O

Accessories and Spare Parts Designation Figure Description Art. no. Warning sign "Clean modules only with a damp cloth." 162796 Resistor error message suppression 05872E00 17310E00 Resistance value: 5K6 / 0.5 W Suitable for: AIM 9468; DIOM 9470; DIOM 9471; DIOM 9472; DOM 9475 single electrical equipment for intrinsically safe circuits according to EN 60079-11 244911 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Remote I/O /7