TIY Programmable, Isolated Thermocouple Transmitter combines

Similar documents
TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

FDY PC-Programmable Frequency-to-DC Transmitter with Display

Isolated, Scaleable 4-20mA with HART Superimposed

SPT. Description. Features. Site-Programmable, Isolated Temperature Transmitter

THZ DH & WL. Features. Smart HART and WirelessHART Temperature Solutions

ECT-DIN. Description. Features. Signal Isolator, Converter, Repeater, Booster and Splitter

ECT-DIN. Features. Signal Isolator, Converter, Repeater, Booster and Splitter. Isolate Signals to stop erratic measurements caused by ground loops.

Two-Wire Programmable Transmitter for:

General Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Fisher 646 Electro Pneumatic Transducer

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Rosemount 148 Temperature Transmitter

250T Loop-Powered (2-wire) Transmitter 250T. Input. Isolation. 350T DC-Powered (3-wire) Transmitter 350T. Input. Isolation

Assembly. Front view. Parametrization interface. Power Bus

Process display RIA 261

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Rosemount 248 Temperature Transmitter

Fisher 646 Electro-Pneumatic Transducers

The Rosemount 848T Wireless Temperature Transmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

P5201 Universal Programmable Transmitters with Galvanic Isolation

Miniature Temptran RTD Transmitters

IP26 Series Current to Pneumatic Converter

Smart Pressure Transmitter

Temperature Measurement Transmitters for mounting in sensor head

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Rosemount 148 Temperature Transmitter

Temperature transmitter with local display RIT 261

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

General Specifications

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Rosemount 248 Temperature Transmitter

Rosemount 644 Temperature Transmitter

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

STT 3000 Smart Temperature Transmitter

Temperature Measurement

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Rosemount 148 Temperature Transmitter

PAD - Heavy Duty Differential Pressure Trasmitter

2002 IS Catalog. Page

Rosemount 644 Temperature Transmitter

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

R88000 T (including ATEX)

Transmitter. Configuration Code TM01 Series 440 Programmable RTD Temperature Transmitter. Application Areas. Features and Benefits

FC-33, DC SELECTABLE SIGNAL CONDITIONER

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Rosemount 3101, 3102, and 3105

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Temperature transmitter itemp PCP DIN rail TMT 121

Universal Intelligent 2-wire DIN Rail Transmitters

0 2 1 â Ó. itemp HART TMT182. Technical Information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Rosemount 644 Temperature Transmitter

Fisher 4200 Series Electronic Position Transmitters

SITRANS T measuring instruments for temperature

Series Smart Pressure Transmitter

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

Rosemount 148 Temperature Transmitter

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Temperature Measurement

FICHA TÉCNICA DE PRODUTO

General Specifications

Temperature head transmitter itemp TC TMT 188

FIELD DEVICES - PRESSURE

Temperature Measurement Transmitters for mounting in sensor head

Temperature Transmitter itemp RTD DIN rail TMT 127

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Head mounted Temperature Transmitter TF02/TF02-Ex

Alphaline Temperature Transmitters

Mass and Volume Flow Transmitter

itemp HART DIN rail TMT112

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

ATT2100/2200 SMART TEMPERATURE TRANSMITTER. Application Areas: ATT 2200 ATT2100

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

SMART TEMPERATURE TRANSMITTERS. smar

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Model TL Linearized Platinum Resistance Thermometer Temperature Transmitter Instruction Manual

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Field indicator for current loops with HART communication Models DIH50, DIH52

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature head transmitter itemp PCP TMT 181

Mass Flow and Density Transmitter

I/A Series Intelligent Temperature Transmitter Model RTT20 Transmitter with Analog 4 to 20 ma Output, or with FoxCom or HART Communication Protocol

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

General Specifications

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT TEL: FAX:

Isolated 4 to 20 ma Transmitters For Demanding Applications Thermocouples, RTD (Pt100) or Ohms, Millivolts, Milliamps, Volts

Rosemount 248 Temperature Transmitter and Monitoring Assembly

Transcription:

April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based, the 2-wire accepts a non-linear temperature input from standard ISA and other thermocouple types, as well as from millivolt sources. It provides an accurate 4-20mA output that is linear with temperature or millivolt input. No Hand-Held Configurator Required The is fast and simple to confi gure. Thermocouple type, range, upscale/downscale drive, and the choice of linearization or no linearization can be quickly selected in the fi eld using tactile push buttons and quick-change solderless jumpers. If linearization is chosen, Moore Industries linearization method assures high accuracy over wide spans as well as smaller spans. No Calibrator Needed The features Moore Industries revolutionary Quick Ranging calibration method. Using the push buttons (instead of potentiometers which can drift) and the integral indicator, precise zero and span adjustments can be made in seconds without a calibrator. The zero or span is displayed on the indicator while the push buttons are used to scroll up or down to the desired value. For field-mounting, the can be ordered in a rugged explosion-proof enclosure. The DIN-style housing is perfect for high-density control room applications. Features Fast and simple to calibrate. Quick Ranging calibration eliminates the need for hand-held terminals, calibrators, and tools. Integral digital indicator. Input in C, F or mv, as well as span and zero adjustments, can be viewed on the display. During start-up, and even if the output goes over range or under range, the display shows current process temperature. Accepts all common T/C types and ranges. Input type and temperature range (-190 C to +1820 C) can be quickly fi eld-selected. There is no minimum span. Intelligent self-diagnostics. Sensor failure, and errors in calibration, memory and unit function are sensed and indicated on the display. Certifications Complete isolation. Prevents false signals due to ground loops. Automatic reference junction compensation. Long-term accuracy is provided by digital reference junction compensation. 2016 Moore Industries-International, Inc. 140-710-01P Page 1

Specifications Performance Output Accuracy: ±0.05% of span (maximum input-tooutput error is the sum of the input, output and Reference Junction Compensation accuracy values. See Table 1 and Figure 1 for details.) Ripple: Less than 10mVp-p maximum (up to frequencies of 120Hz) measured across a 250 ohm load resistor Burnout Protection: Upscale drive is the standard factory confi guration; downscale drive can be confi gured via a solderless jumper Operating Limits: No damage up to ±42V on input and ±60V on output Output Protection: Transient protection and reverse polarity protection Output Current Limiting: 125% of span, typical; 130% of span, maximum Load Capability: (Vp - 12V) Ohms = 0.024 Performance (continued) Ambient Temperature Common Mode Rejection: At least 120dB at 50Hz/60Hz Isolation: 500Vrms galvanic isolation between input and output terminals RFI/EMI Protection: When tested according to SAMA Standard PMC 33.1, protection rates: DIN and HP/FL Housings: 10V/m A B C < 0.1% of maximum span 2LG and 2LS (HP housing in explosion-proof enclosure): 30V/m - ABC 0.025% of maximum span < Operation: -40 C to +82 C (-40 F to +180 F) Momentary, recoverable dimming of display may occur at low temperatures Effect (except reference junction compensation): ±0.01% of maximum span/ C Reference Junction Compensation Effect: ±0.75 C/50 C change in ambient temperature Adjustments Indicators Weight Zero and Span: Adjusted via tactile push buttons on front of unit Range: Span changes within an input range (see Range Codes in Table 1) are made with push buttons; changing Range Code selection is done by changing the positions of solderless jumpers Type: 4-digit LCD indicates input value in C, F or millivolts (jumper-selectable); also indicates zero and full scale values, problem codes, and high or low table limit warnings Display Accuracy: ±0.1% of maximum span for range code, ±1 count DIN Housing: 141 grams (5 ounces) HP Housing: 184 grams (6.5 ounces) Certifications -HP CSA Group (Canadian Standards Associations): Intrinsically-Safe Class I, Division 1, Groups A, B, C, D, T4 FM Global Group (FM Approvals): Non-Incendive Class I, Division 2, Groups A, B, C, D CE Conformant EMC Directive 2014/30/EU: EN61326 -DIN FM Global Group (FM Approvals): Non-Incendive Class I, Division 2, Groups A, B, C, D CE Conformant EMC Directive 2014/30/EU: EN61326 -HP in BH or SB2 Housing CSA Group (Canadian Standards Association): Explosion-Proof Class I, Division 1, Groups A*, B, C & D Class II, III, Groups E, F & G Type 4X, IP66 Ambient Temp. Range: -20 C to +85 C; T4 *For U.S. Group A applications, seal all conduits within 18 *For U.S. Group A applications, seal all conduits within 18 *Factory Mutual Approvals (FM Global Group): Explosion-Proof & Dust-Ignition Proof Class I, Division 1, Groups A*, B, C & D Class II & III, Division 1, Groups E, F & G Environmental Protection: Type 4X & IP66 T6 @ 60 C Maximum Operating Ambient *For Group A applications, seal all conduits within 18 Test Safe ANZEx (Australia) Flameproof Ex d IIC T6 (Tamb 60 C) ANZEx 07.3027 ISSeP ATEX Flameproof II 2 G Ex d IIC T6 Gb II 2 D Ex tb IIIC Db T85 C IP66 Page 2 Specifi cations and information subject to change without notice. Printed in U.S.A.

Ordering Information Unit Input Output Power Options Housing See Range Codes (e.g., J1, K2, N1) in Table 1 4-20MA into 600 ohms with 24Vdc power supply 12-30DC (required for -ISC option) 12-42DC -DD Downscale Drive output goes downscale within two seconds after an open input or an instrument fault is detected (Upscale or Downscale Drive is jumper-selectable) -DDX** Direct Downscale Drive output goes downscale on open input. Output will not exceed process value on open input or reconnection of an open input -NL Confi gured to provide output linear with input, rather than linear with temperature (jumper-selectable) -SP1 Low temperature range for J- and T-type thermocouples (replaces N1 and N2 Range Codes) -SP2 Required for B1 Range Code (replaces S1 Range Code) -CE EMC conformant -ISC Intrinsically-Safe, CSA (12-30Vdc power required) BH2NG (*) or ( ) Aluminum Explosion-Proof enclosure with two ½-inch NPT entry ports and a BH2TG (*) or ( ) Aluminum Explosion-Proof enclosure with two ¾-inch NPT entry ports and a BH2MG (*) or ( ) Aluminum Explosion-Proof enclosure with two M20 x 1.5 NPT entry ports and a BH3NG (*) or ( ) Aluminum Explosion-Proof enclosure with three ½-inch NPT entry ports and a BH3TG (*) or ( ) Aluminum Explosion-Proof enclosure with two ¾-inch NPT side-entry ports, one ½-inch NPT bottom-entry port and a BH3MG (*) or ( ) Aluminum Explosion-Proof enclosure with two M20 x 1.5 metric side-entry ports, one ½-inch NPT bottom-entry port, and a D2LC 2-Hub, low base, clear cover, NEMA 4X (IP 66) enclosure D2LS 2-Hub, low base, solid black cover, NEMA 4X (IP 66) enclosure HP Hockey-puck housing (only) includes spring clips for mounting in the above enclosures FL Hockey-puck housing with fl anges for surface or relay track mounting * Either A or E suffi x (comes supplied with 2 pipe mount hardware) A suffi x indicates ANZEx/TestSafe (Ex d) Flameproof approvals (i.e. BH2MGA) E suffi x indicates ATEX (Ex d and td) Flameproof approvals (i.e. BH2MGE) P suffi x indicates enclosure comes equipped with base plate and U-bolts for mounting on a 2-inch pipe (i.e. BH2NGP) See BH and D-BOX Datasheets for additional information. See Range Codes (e.g., J1, K2, N1) in Table 1 4-20MA into 600 ohms with 24Vdc power supply 12-42DC -DD Downscale Drive output goes downscale within two seconds after an open input or an instrument fault is detected (Upscale or Downscale Drive is jumper-selectable) -DDX** Direct Downscale Drive output goes downscale on open input. Output will not exceed process value on open input or reconnection of an open input -NL Confi gured to provide output linear with input, rather than linear with temperature (jumper-selectable) -SP1 Low temperature range for J- and T-type thermocouples (replaces N1 and N2 Range Codes) -SP2 Required for B1 Range Code (replaces S1 Range Code) *Consult factory for availability. **The DDX option prohibits the from being confi gured for an upscale failsafe. DIN DIN housing mounts on G or Top Hat Rail When ordering, specify: Unit / Input code, temperature or millivolt range and scale ( C, F or mv) / Output / Power / Options [Housing] Model number examples: / K1-0-100C / 4-20MA / 12-42DC [DIN] / MV1-0-75MV / 4-20MA / 12-42DC [BH2NG] Page 3

Table 1. Range Codes for Thermocouple and Millivolt Input Ranges Input Range Range Limits Accuracy Type Code Lower 1 Upper 2 Reference (= to 4mA) (= to 20mA) Input Output 3 Junction Compensation Thermocouple Input Ranges J1-50 C (-58 F) 450 C (842 F) ±0.08 C (±0.14 F) ±0.05% of span ±0.25 C (±0.45 F) J J2-50 C (-58 F) 760 C (1400 F) ±0.25 C (±0.45 F) ±0.05% of span ±0.25 C (±0.45 F) J3* -130 C (-202 F) 130 C (266 F) ±0.6 C (±0.10 F) ±0.05% of span ±0.25 C (±0.45 F) K K1-50 C (-58 F) 450 C (842 F) ±0.10 C (±0.18 F) ±0.05% of span ±0.25 C (±0.45 F) K2-50 C (-58 F) 1370 C (2498 F) ±0.30 C (±0.54 F) ±0.05% of span ±0.25 C (±0.45 F) E1-10 C (14 F) 350 C (662 F) ±0.10 C (±0.18 F) ±0.05% of span ±0.25 C (±0.45 F) E E2-100 C (-148 F) 1000 C (1832 F) ±0.25 C (±0.45 F) ±0.05% of span ±0.25 C (±0.45 F) E3-100 C (-148 F) 50 C (122 F) ±0.06 C (±0.10 F) ±0.05% of span ±0.25 C (±0.45 F) T1-50 C (-58 F) 400 C (752 F) ±0.10 C (±0.18 F) ±0.05% of span ±0.25 C (±0.45 F) T T2-100 C (-148 F) 100 C (212 F) ±0.08 C (±0.14 F) ±0.05% of span ±0.25 C (±0.45 F) T3* -190 C (-310 F) 50 C (122 F) ±0.12 C (±0.21 F) ±0.05% of span ±0.25 C (±0.45 F) R R1-18 C (0 F) 1760 C (3200 F) ±0.60 C (±1.08 F) ±0.05% of span ±0.25 C (±0.45 F) S S1-18 C (0 F) 1760 C (3200 F) ±0.50 C (±0.90 F) ±0.05% of span ±0.25 C (±0.45 F) N N1-50 C (-58 F) 1300 C (2372 F) ±0.40 C (±0.72 F) ±0.05% of span ±0.25 C (±0.45 F) N2-50 C (-58 F) 700 C (1292 F) ±0.15 C (±0.27 F) ±0.05% of span ±0.25 C (±0.45 F) B B1** 200 C (392 F) 1820 C (3308 F) ±0.80 C (±1.44 F) 4 ±0.05% of span ±0.25 C (±0.45 F) Millivolt Input Ranges MV1-10mV 75mV 10 microvolts ±0.05% of span N/A mv MV2-6mV 24mV 3.4 microvolts ±0.05% of span N/A MV3-10mV 7mV 2 microvolts ±0.05% of span N/A No Code PRG Specify when input type and range are undetermined or when unit will be stocked as a universal spare (PRG default is J1-0-100 C). *SP1 option required for J3 and T3 Range Codes (replaces N1 and N2 Range Codes). ** SP2 option required for B1 Range Code (replaces S1 Range Code). NOTES 1. The output will limit at values which are 5% of maximum span lower than this value and will then display LO. 2. The output will not exceed values which are 10% of maximum span greater than this value. When exceeded, the display reads HI. 3. Output accuracy is in relation to the unit s calibrated span (±0.05% of actual span that will be used for the application). 4. Valid for 400 C and above. Page 4

Figure 1. Determining Maximum Error (see Table 1 for Input, Output and Reference Junction Compensation Accuracies) Input Accuracy Reference Junction + Output Accuracy + = Compensation Accuracy Maximum Error Example: ±0.08 C (J1 Range Code) ±0.05 C + + (±0.05% of 0-100 C Span) ±0.25 C = ±0.38 C Figure 2. Outline Dimensions for DIN-Style Housing 35mm (1.37 in) 138mm (5.44 in) 133mm (5.27 in) 129mm (5.07 in) +IN IN +PS PS 42mm (1.65 in) 80mm (3.15 in) C L SAVE ZERO CANCEL SPAN (1.5 in) 38mm Figure 3. Outline Dimensions for FL and HP Housings 76mm (3.00 in) 38mm (1.50 in) FL HOUSING 61mm (2.43 in) HP HOUSING 57mm (2.26 in) +PS -PS +IN - IN SAVE ZERO SPAN CANCEL FL HOUSING 73mm (2.86 in) HP HOUSING 62mm (2.43 in) FL HOUSING 83mm (3.25 in) FRONT VIEW SIDE VIEW Page 5

SAVE Figure 4. Dimensions of the in a BH Housing SIDE VIEW 102mm (4.00 in) GND 119mm (4.70 in) 57mm (2.25 in) 22mm (0.88 in) 1/2 NPT 76mm (3.00 in) TOP VIEW 10mm (0.38 in) 64mm (2.53 in) 102mm (4.00 in) 84mm (3.31 in) 68mm (2.69 in) ZERO SPAN CANCEL +PS -PS +IN - IN 68mm (2.66 in) 53mm (2.09 in) 124mm (4.90 in) 25mm (1.00 in) 66mm (2.60 in) United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62491499 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Page 6