POWER FACTOR CORRECTION AND ITS PITFALLS

Similar documents
UNDERSTANDING POWER QUALITY

POWER QUALITY MONITORING - PLANT INVESTIGATIONS

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

Power Quality and Reliablity Centre

Power Factor. Power Factor Correction.

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Harmonic control devices

Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

Effects of Harmonic Distortion I

MAINS SIGNAL PROPAGATION THROUGH DISTRIBUTION SYSTEMS. J. Stones*, S. Perera*, V. Gosbell* and N. Browne**

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

APPLICATION NOTE. Applying Type DD60 Capacitors in Harmonic Filter Applications. Total Power Factor PF = cosine ɸ

Question Paper Profile

22.0 Harmonics in Industrial Power Systems

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

Study of Inductive and Capacitive Reactance and RLC Resonance

2.0 AC CIRCUITS 2.1 AC VOLTAGE AND CURRENT CALCULATIONS. ECE 4501 Power Systems Laboratory Manual Rev OBJECTIVE

Power Quality Monitoring and Power Metering Tutorial

ZENER ELECTRIC PTY LTD

Improve Power Factor and Reduce the Harmonics Distortion of the System

CHAPTER 4 HARMONICS AND POWER FACTOR

Thyristorised Automatic Power Factor

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

Power Factor and Power Factor Correction

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Sizing Generators for Leading Power Factor

7/15/2002 PP.AFD.08 1 of 28

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

Low Pass Harmonic Filters

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

APPLICATIONS. AFQ Active Multi-Function Filter. AFQ solves thousands of problems in countless types of installations, in particular the following:

Influence of Switching Elements on Harmonics and Power Factor Improvement

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Study of Power Factor Correction in Single Phase AC-DC Converter

Do Capacitor Switching Transients Still Cause Problems?

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Outcomes of Harmonics & Its Reduction Techniques: A Comprehensive Review

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Voltage and Current Waveforms Enhancement using Harmonic Filters

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Series and Parallel Resonant Circuits

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI UNIT III TUNED AMPLIFIERS PART A (2 Marks)

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY:

Reducing Total Harmonic Distortion with Variable Frequency Drives

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Harmonic Levels and Television Events

A Power Quality Survey on a 22 kv Electrical Distribution System of a Technical Institution as per Standards

Power Quality Analysis in Power System with Non Linear Load

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

Active Harmonic Filter (AF3)

Generator Advanced Concepts

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

Design and Simulation of Passive Filter

Thermal Imaging, Power Quality and Harmonics

BAKISS HIYANA BT ABU BAKAR JKE,POLISAS

VETRI VINAYAHA COLLEGE OF ENGINEERING AND TECHNOLOGY

Downloaded from / 1

Alternating Current Study Guide. Preface. This module is DIFFICULT.

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

LINEATOR. Advanced Universal Harmonic Filter

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

Chapter 2 Shunt Active Power Filter

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Power Factor & Harmonics

ELEC207 LINEAR INTEGRATED CIRCUITS

UEENEEG048B Solve problems in complex multi-path power circuits SAMPLE. Version 4. Training and Education Support Industry Skills Unit Meadowbank

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

ANALYSIS OF VOLTAGE TRANSIENTS IN A MEDIUM VOLTAGE SYSTEM

Voltage-controlled active filter gives standby generator power quality

Preface...x Chapter 1 Electrical Fundamentals

McGill Power Sales & Engineering, INC.

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

How adjustable speed drives affect power distribution

INTRODUCTION PROPOSED SOLUTION STEPS TAKEN. MATLAB Simulation

UNIT 1 CIRCUIT ANALYSIS 1 What is a graph of a network? When all the elements in a network is replaced by lines with circles or dots at both ends.

Power Quality Notes 2-2 (AK)

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Application of Reactive Compensation equipment in industrial systems under aspects of harmonics and switching transients: A study of real case

Oversimplification of EMC filter selection

Reduction Of Harmonics By Using Active Harmonic Filter

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

POWER FACTOR CORRECTION USING BOOST CONVERTER

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS)

Transmission Line Models Part 1

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

University Tunku Abdul Rahman LABORATORY REPORT 1

Understanding Harmonics

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

HARMONICS CAUSES AND EFFECTS

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

APPLICATION NOTE - 018

POWERED electronic equipment with high-frequency inverters

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

LCR Parallel Circuits

Transcription:

Technical Note No. May 1999 POWER FACTOR CORRECTION AND ITS PITFALLS This Technical Note considers power factor correction as applied by large customers and the possible consequences when power factor correction capacitors are incorrectly applied where there are major harmonic producing loads such as adjustable speed drives. Integral Energy, your local Network Operator or the Integral Energy Power Quality Centre can give you advice if you have particular concerns with these issues. Summary Large customers tend to install power factor correction capacitors because of the associated cost savings. While this is advantageous to both the customer and the electricity supplier incorrect application of capacitors can lead to equipment damage. There are numerous customer loads, such as adjustable speed drives and computers, which draw distorted currents from the supply network adding distortion to the ideal sinusoidal voltage waveform. In particular, power factor correction capacitors should be applied in such situations with care as they can magnify distortion causing damage to capacitors themselves and other plant equipment. Even if there are no distorting loads in a customer premises, power factor correction capacitors can cause problems if incorrectly applied, as waveform distortion can be present due to other customers connected to the same network. Careful investigations into the supply network and the nature of the loads within customer s installation is required before connection of capacitor banks. Problems can be avoided by connecting suitable detuning inductors in series with the capacitors. Contents 1. Basics of power factor correction. Power factor of an installation having distorting loads 3. Harmonic distortion 4. Overloading of power factor correction capacitors in the presence of harmonic currents 5. Power factor correction capacitors and harmonic resonance 6. Detuning the power factor correction capacitors 7. Integral Energy Power Quality Centre

1. Basics of power factor correction Power system loads can be generally classified into non-distorting and distorting loads. The total current drawn by most non-distorting loads consists of a component of current (i ip ) which is in phase with the supply voltage (v) and a component (i op ) of current which is out of phase as illustrated in Figure 1. The in-phase component of the current carries power to the load whereas the out-of-phase component establishes the necessary magnetic fields within equipment such as induction motors that are commonly found in many industrial and commercial installations. v i ip i op Figure 1: Voltage, in-phase current and out-of-phase current components. Although the component current i op carries no power to the load it causes extra voltage drops and heat losses in the power supply network. It also means that the electricity supplier has to accommodate this extra component of current when the size of distribution lines and transformers is determined. The rating of equipment is given by the total current equal to i + i ip op As a measure of the component current i op the term power factor defined by the ratio of the in-phase component of current to the total current is generally used. The best possible value of power factor is unity, when i op is zero. Any procedure, which reduces i op increasing the value of power factor towards unity, is a form of power factor improvement and will help the electricity supplier. The electricity tariff that is often applicable to large customers is based on two components: (a) real power - product of voltage and in-phase current (b) apparent power product of voltage and total current (which is also called the demand). Therefore improvement of the power factor is advantageous to the customers.

One of the most common methods of power factor correction is the installation of shunt connected capacitors by the customer. The current through a capacitor (i c ) is in anti-phase with the current i op as shown in Figure and, if properly chosen, will lead to a reduction in the total current drawn by the customer. v i ip i op i c Figure : Capacitor current i c voltage and the component currents i ip and i op. Power factor of an installation having distorting loads As the demand changes during the day capacitor banks have to be switched in and out. Normally the power factor correction capacitors are selected so that power factor established after installing the capacitors is still lagging but close to unity. The above discussion has been based on the assumption that the customer load is non-distorting (load current is sinusoidal) but most industrial loads these days tend to draw currents having waveforms that are distorted. Such loads include adjustable speed motor drives that are powered by power electronic systems and electronic office equipment. The waveform of the AC supply side current of an adjustable speed ac induction motor drive is shown in Figure 3. time Figure 3: AC supply side current waveform of an adjustable speed induction motor drive. 3

This current waveform can be considered to consist of a large number of sinusoidal current waveforms of differing frequencies including the fundamental frequency which is 50Hz. The other frequencies present in the waveform are integer multiples of 50Hz and are called harmonics (See Technical Note 1). These harmonics take the frequencies 50Hz, 350Hz, 550Hz, 650Hz, 850Hz, etc. The ratio of these frequencies to the fundamental frequency is called a harmonic order (n), ie harmonics are of the order 5, 7, 11, 13, 17, etc. Normally, as the order increases the magnitude of the corresponding current decreases, Figure 4 illustrates the spectrum of these currents expressed in the form of a bar graph for the waveform of Figure 3. 10 100 80 60 40 0 0 1 3 5 7 9 11 13 15 17 19 1 3 5 7 9 31 Figure 4: Spectrum of harmonics of the AC side input current waveform of an adjustable speed induction motor drive. 3. Harmonic distortion For an installation which contains a load such as an adjustable speed induction motor drive it has to be noted that the total current includes the harmonic current components as well as the fundamental. For example consider a situation where the fundamental current is 50A, 5 th harmonic is 35A and the 7 th harmonic is 10A. Also assume that the above fundamental current has an in-phase component of 40A. The power factor in this situation is given by: 50 40 + 35 + 10 = 0.65 Harmonic currents drawn by a load can lead to further distortion of the voltage waveform at the customer entry point in addition to the already existing background voltage distortion on the supply network. In most situations, although the current distortion can be high as seen from the waveform of Figure 3, the voltage waveform may show only a little distortion. For example, the voltage waveform shown in Figure 5 is typical, having distortion in the form of a flat top. 4

Figure 5: Waveform of the voltage on a low voltage network of a commercial premises. The level of voltage distortion at the customer entry point depends on (a) the level of distortion of the current drawn from the power system (b) the impedance of the supply system at the customer. Normally the magnitude of the impedance seen by the harmonic currents will increase linearly as the order of the harmonic increases. For example, for a power supply network which has an impedance of 0.1 ohm at 50Hz, the impedance seen by the 5 th harmonic current is 0.1x5 (0.5) ohm If the 5 th harmonic current is 0A then the 5 th harmonic voltage is 0.1x5x0 (10) volts. 4. Overloading of power factor correction capacitors in the presence of harmonic currents As noted above without power factor correction capacitors the harmonic currents see a power system impedance which is linearly proportional to the order of the harmonic. Hence the harmonic currents will find it difficult to propagate through the power system as the harmonic order increases. However, this is not the case when there are power factor correction capacitors in the power system as the impedance of capacitors is inversely proportional to the harmonic order. Thus, the power factor correction capacitors which were meant to draw a component of current at 50Hz would now offer a reduced impedance to the harmonic currents. As a result, higher order harmonic currents will easily flow through the capacitors overloading them and causing damage to the capacitor banks if care is not taken. 5. Power factor correction capacitors and harmonic resonance A further aspect which needs careful consideration in the use of power factor correction capacitors in a situation where there are strong harmonic currents is the phenomena known as parallel resonance leading to an amplification of harmonic currents. In the presence of power factor correction capacitors the total impedance seen by the harmonic currents is the parallel combination of the normal power system impedance (which is linearly proportional to the harmonic order) and the impedance of capacitors (which is inversely proportional to the harmonic order) as shown in Figure. 6. 5

power system load Figure 6 Parallel combination of power system impedance with power factor correction capacitors These impedances have the opposite signs and so total impedance increases with the harmonic order quite rapidly to a high value and then falls off as the harmonic order further increases. This is illustrated in Figure 7 for a power supply network for different sizes of power factor correction capacitor banks. The Figure also shows the impedance of the same network with no capacitors connected. It is clear that if there is a load current harmonic which is close to the peaky sections of the curves a substantial voltage can be developed causing serious voltage distortion. Magnitude of impedance 00kVAr 500kVAr 100kVAr 50kVAr no capacitors Figure 7: Variation of the impedance with harmonic order for different capacitor banks The harmonic order at which the parallel resonance takes place can be worked out using the following expression: n 0 10 0 30 40 Harmonic order = SFL Sc where S FL = fault level at the customer entry point, kva S c = capacitor kvar which suggests that the parallel resonance frequency reduces as the capacitor kvar rating increases and vice versa as shown in Figure 7. 6

For example, at a customer entry point of an industrial installation where the fault level is.5mva with a 100kVAr capacitor bank parallel resonance will take place at 50Hz (ie n = 5). 6. Detuning the power factor correction capacitors It is important to avoid parallel resonance at a frequency which is close to a frequency of a harmonic current of the distorting load. The common practice is to detune the capacitor bank so that the lowest order load current harmonic sees a very small impedance. This is achieved by adding an inductor in series with the power factor correction capacitors leading to a situation commonly known as series resonance. At the frequency where series resonance takes place the impedance seen by the harmonic currents is small (see Figure 8) and hence the power factor correction capacitors together with the detuning inductor work as a harmonic filter reducing the voltage distortion. As seen in Figure 8, although parallel resonance still takes place, it happens at a frequency which does not correspond to the lowest frequency of the current harmonic (n=5 in this case) that is present in the load current and hence there will be no serious voltage distortion. Magnitude of impedance parallel resonance series resonance 0 5 10 15 0 5 30 35 40 Harmonic order Figure 8: Variation of the impedance with detuning inductor It has to be noted that the capacitor still provides the fundamental reactive power while working as a harmonic filter. This is quite favourable in a situation where both power factor correction and harmonic filtering is required. However, proper selection of capacitor and detuning inductor is essential for the success of the installation. Careful system studies covering all configurations of the network and the load must be undertaken before installing power factor correction capacitors even if there are no major harmonic current producing loads in a premises as capacitors can absorb network harmonics thus creating situations not expected in the first place. 7

7. Integral Energy Power Quality Centre In July 1996, Integral Energy set up Australia s first Power Quality Centre at the University of Wollongong. The Centre s objective is to work with Industry to improve the quality and reliability of the electricity supply to industrial, commercial and domestic users. The Centre specialises in research into the control of distortion of the supply voltage, training in power quality issues at all levels, and specialised consultancy services for solution of power quality problems. You are invited to contact the Centre if you would like further advice on quality of supply. ABOUT THE AUTHORS Vic Gosbell is the Technical Director of the Integral Energy Power Quality Centre and Associate Professor in the School of Electrical, Computer and Telecommunications Engineering at the University of Wollongong. Sarath Perera is a Senior Lecturer in the School of Electrical, Computer and Telecommunications Engineering at the University of Wollongong. Vic Smith is a Research Engineer for the Integral Energy Power Quality Centre. FURTHER INFORMATION CAN BE OBTAINED BY CONTACTING: Associate Professor V. J. Gosbell Technical Director Integral Energy Power Quality Centre School of Electrical, Computer and Telecommunications Engineering University of Wollongong NSW AUSTRALIA 5 Ph: (0) 41 3065 or (0) 41 340 Fax: (0) 41 336 Email: v.gosbell@elec.uow.edu.au 8