NI PXI-2520 Specifications 80-Channel SPST Relay Module

Similar documents
NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

NI PXI/PXIe-2529 Specifications

NI PXI/PXIe-2527 Specifications

NI PXI/PXIe-2540 Specifications

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI PXI-2555 Specifications

NI PXI-2557 Specifications

NI PXI-2530 Specifications

NI PXI/PXIe-2532 Specifications

SCXI MHz Quad 8x1 50 Ω Multiplexer

PXI Contents. PXI-2585 Specifications. Topology DEVICE SPECIFICATIONS. 10-Channel Multiplexer

NI SCXI Specifications

NI PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. 3 GHz Ω Multiplexer (SP16T)

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

PXI Contents. PXI-2584 Specifications DEVICE SPECIFICATIONS. 300 V CAT II, 600 V CAT I Multiplexers

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

NI PXI Contents. About These Specifications DEVICE SPECIFICATIONS GHz Dual Transfer Switch 50 Ω Relay Module

NI PXI-2532 Specifications

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 40 A Fault Insertion Unit

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 10 A Fault Insertion Unit

100-SPST (latching), 50-DPST. Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

Analog Characteristics

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

Related Information Refer to the NI Switches Help for detailed topology information.

NI PXIe-5630 Specifications

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

Related Information Refer to the NI Switches Help for detailed topology information.

NI PXI/PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. Quad 2 1 Terminated Multiplexer

PXIe Contents SPECIFICATIONS. RF Amplifier

1- or 2-Port, High-Speed, Flexible Data Rate PXI CAN Interface Module

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

PXIe Contents SPECIFICATIONS. RF Preselector Module

Analog Input. DEVICE SPECIFICATIONS NI PXIe-4300

DEVICE SPECIFICATIONS NI PXIe Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

1- or 2-Port, Software-Selectable PXI CAN Interface Module

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

NI PXIe-5601 Specifications

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. 50 MHz to 2.2 GHz Tunable RF Transceiver

PXI Contents SPECIFICATIONS. 6.6 GHz RF Analog Signal Generator

PXI Contents SPECIFICATIONS. 1.3 GHz RF Analog Signal Generator

High-Speed/Flexible Data-Rate CAN Characteristics 5 VDC

CDA Contents. Definitions SPECIFICATIONS. Clock Distribution Device

PXIe Contents SPECIFICATIONS. 3.3 GHz RF Analog Signal Generator

100 MHz Bandwidth, 12-Bit PXI Waveform Generator

USRP Contents. Definitions SPECIFICATIONS. 10 MHz to 6 GHz Tunable RF Transceiver

This document lists the specifications for the NI PXI The PXI-5900 is a differential amplifier.

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

PXIe Contents SPECIFICATIONS. 250 khz to 20 GHz RF Analog Signal Generator

4-Channel, ±6 V, 500 ma Precision PXI Source Measure Unit

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

4-Channel, ±24 V, 150 ma PXI Source Measure Unit

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

DEVICE SPECIFICATIONS NI PXIe-4302/ Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module

SPECIFICATIONS PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

4-Channel, ±24 V, 150 ma Precision PXI Source Measure Unit

NI Channel SPST Electromechanical Relay Module

Note Using the NI 5751/5751B in a manner not described in this document may impair the protection that the NI 5751/5751B provides.

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

DEVICE SPECIFICATIONS NI PXIe-4304/ Ch, 24-bit, ±42 V, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

NI Channel, Universal Digital Input Module

PXIe Contents SPECIFICATIONS. ±60 V, 3 A System PXI Source Measure Unit. These specifications apply to the PXIe-4138.

16-Bit, 120 MS/s, 12 Channel DC/16 Channel AC Receiver Adapter Module

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter

PXIe, 24-Channel, ±24 V, 50 ma Precision PXI Source Measure Unit

PXIe Contents SPECIFICATIONS. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. These specifications apply to the PXIe-4112.

SPECIFICATIONS PXIe Ch (8 ADC), 2 MS/s, bit, Flexible Resolution PXI Analog Input Module

PXIe Contents SPECIFICATIONS. ±200 V, 1 A System PXI Source Measure Unit. These specifications apply to the PXIe-4136.

OPERATING INSTRUCTIONS NI Port DeviceNet Module

DEVICE SPECIFICATIONS Phase Matrix PXI GHz PXI Vector Signal Analyzer

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

NI roborio. Contents. Processor SPECIFICATIONS. RIO Device for Robotics

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

DATASHEET NI Channel, 250 V Sinking Digital Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

USRP Contents. Definitions SPECIFICATIONS. USRP Software Defined Radio Stand-Alone Device

NI PXIe-5663 Specifications

PXIe Contents SPECIFICATIONS. ±60 V, 3 A Precision System PXI Source Measure Unit. These specifications apply to the PXIe-4139.

NI Channel, TTL Digital Input/Output Module

PXIe Contents SPECIFICATIONS. ±200 V, 1 A Precision System PXI Source Measure Unit. These specifications apply to the PXIe-4137.

Terminology. Output Characteristics. DEVICE SPECIFICATIONS NI PXIe-4463 DSA Analog Output. ni.com/manuals

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

SCC-CO20 Isolated Current Output Module

NI 6731/6733 Specifications

Specifications are typical and valid from -40 C to +85 C unless otherwise noted. Galvanic isolation between channels and to chassis

PXI Contents SPECIFICATIONS. 8-Channel, 12-Bit, 60 MHz PXI Oscilloscope

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

Analog Input SPECIFICATIONS NI 6320/6321/6323

80 MHz Bandwidth, 16-Bit PXI Waveform Generator. These specifications apply to the one-channel and two-channel PXIe-5433.

8-Channel, 12-Bit, 60 MHz PXI Express Oscilloscope

Transcription:

NI PXI-2520 Specifications 80-Channel SPST Relay Module This document lists specifications for the NI PXI-2520 general-purpose relay module. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Caution The protection provided by the NI PXI-2520 can be impaired if it is used in a manner not described in this document. Topology... 80-channel SPST, non-latching Refer to the NI Switches Help for detailed topology information. About These Specifications Specifications characterize the warranted performance of the instrument under the stated operating conditions. Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 C ambient temperature. Typical specifications are not warranted. All voltages are specified in DC, AC pk, or a combination unless otherwise specified. Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility document for important safety and electromagnetic compatibility information. To obtain a copy of this document online, visit ni.com/manuals, and search for the document title. Caution To ensure the specified EMC performance, operate this product only with shielded cables and accessories. Input Characteristics Maximum switching voltage Channel-to-channel... 150 V Channel-to-ground... 150 V, CAT I Caution This module is rated for Measurement Category I and intended to carry signal voltages no greater than 150 V. This module can withstand up to 800 V impulse voltage. Do not use this module for connection to signals or for measurements within

Categories II, III, or IV. Do not connect to MAINS supply circuits (for example, wall outlets) of 115 or 230 VAC. Refer to the Read Me First: Safety and Electromagnetic Compatibility document for more information on measurement categories. Caution When hazardous voltages (>42.4 V pk /60 VDC) are present on any relay terminal, safety low-voltage ( 42.4 V pk /60 VDC) cannot be connected to any other relay terminal. Caution The switching power is limited by the maximum switching current, the maximum voltage, and must not exceed 60 W, 62.5 VA. Maximum switching power (per channel)...60 W, 62.5 VA (DC to 60 Hz) Maximum current (switching or carry, per channel)...2 A Simultaneous channels at maximum current ( 43 C)...30 Minimum switching conditions...20 mv/1 ma Note Switching inductive loads (for example, motors and solenoids) can produce high voltage transients in excess of the module s rated voltage. Without additional protection, these transients can interfere with module operation and impact relay life. For more information about transient suppression, visit ni.com/info and enter the Info Code relayflyback. DC path resistance Initial...<0.5 Ω End-of-life... 1.0 Ω DC path resistance typically remains low for the life of the relay. At the end of relay life, the path resistance rises rapidly above 1 Ω. Load ratings apply to relays used within the specification before the end of relay life. Thermal EMF (typical at 23 C)...12 μv Bandwidth (-3 db, typical at 23 C) 50 Ω termination... 35 MHz Crosstalk (typical at 23 C, 50 Ω termination) Channel-to-channel 10 khz... -80 db 100 khz... -60 db Isolation (typical at 23 C, 50 Ω termination) Open channel 10 khz... 80 db 100 khz... 60 db 2 ni.com NI PXI-2520 Specifications

Module Load Derating at >43 C Load derating is dependent on the ambient temperature and the sum of the current squared of each channel simultaneously carrying a signal. The result must fall within the shaded region of Figure 1. The following examples represent this calculation. Example 1 30 channels carry 1.7 A while 10 channels carry 1.5 A (30 1.7 2 ) + (10 1.5 2 ) = 109.2 A 2 channels The module in Example 1 can be used at ambient temperatures between 0 C and 47 C. Example 2 25 channels carry 1.55 A while 5 channels carry 2.0 A (25 1.55 2 ) + (5 2.0 2 ) = 80.06 A 2 channels The module in Example 2 can be used at ambient temperatures between 0 C and 55 C. 120 Figure 1. Module Load Derating Power Load (Amp 2 * Channels) 100 80 60 40 20 0 0 10 20 30 Ambient Temperature ( C) 40 50 60 Dynamic Characteristics Relay operate time Typical... 1 ms Maximum... 3.4 ms Simultaneous drive limit... 40 relays NI PXI-2520 Specifications National Instruments 3

Note Certain applications may require additional time for proper settling. For information about including additional settling time, refer to the NI Switches Help. Expected relay life Mechanical...1 10 8 cycles Electrical (resistive) 30 V, 1 A...5 10 5 cycles 30 V, 2 A...1 10 5 cycles Note The relays used in the NI PXI-2520 are field replaceable. Refer to the NI Switches Help for information about replacing a failed relay. Trigger Characteristics Input trigger Sources...PXI trigger lines 0-7 Minimum pulse width...150 ns Note The NI PXI-2520 can recognize trigger pulse widths less than 150 ns if you disable digital filtering. For information about disabling digital filtering, refer to the NI Switches Help. Output trigger Destinations...PXI trigger lines 0-7 Pulse width...programmable (1 μs to 62 μs) Physical Characteristics Relay type...electromechanical, non-latching Relay contact material...palladium-ruthenium, gold covered I/O connector...160 DIN 41612, 160 positions, male PXI power requirement...6 W at 5 V, 2.5 W at 3.3 V Dimensions (L W H)...3U, one slot, PXI/cPCI module 21.6 2.0 13.0 cm (8.5 0.8 5.1 in.) Weight...174 g (6.1 oz) 4 ni.com NI PXI-2520 Specifications

Environment Operating temperature... 0 C to 55 C Storage temperature... -20 C to 70 C Relative humidity... 5% to 85% noncondensing Pollution Degree... 2 Maximum altitude... 2,000 m Indoor use only. Shock and Vibration Operational Shock... 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random Vibration Operating... 5 to 500 Hz, 0.3 g rms Nonoperating... 5 to 500 Hz, 2.4 g rms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Diagrams Figure 2 shows the NI PXI-2520 hardware diagram. Figure 2. NI PXI-2520 Hardware Diagram K0 CH0 COM0 K1 CH1 COM1 K79 CH79 COM79 NI PXI-2520 Specifications National Instruments 5

6 ni.com NI PXI-2520 Specifications Figure 3 shows the NI PXI-2520 connector pinout. Figure 3. NI PXI-2520 Connector Pinout CH0 COM0 B32 A32 C32 D32 E32 COM4 COM1 CH1 C31 D31 E31 CH4 COM3 CH3 C30 D30 E30 COM9 COM6 CH6 C29 D29 E29 CH9 COM8 CH8 C28 D28 E28 COM14 COM11 CH11 C27 D27 E27 CH14 COM13 CH13 C26 D26 E26 COM19 COM16 CH16 C25 D25 E25 CH19 COM18 CH18 C23 D23 E23 CH24 COM23 CH23 C22 D22 E22 COM29 COM26 CH26 C19 D19 E19 CH34 COM33 CH33 C18 D18 E18 COM39 COM36 CH36 C17 D17 E17 CH39 COM38 CH38 CH2 COM2 B31 A31 CH5 COM5 A30 B30 CH7 COM7 B29 A29 CH10 COM10 B28 A28 CH12 COM12 B27 A27 CH15 COM15 B26 A26 CH17 COM17 B25 A25 CH20 COM20 B24 A24 CH22 COM22 A23 B23 CH25 COM25 B22 A22 CH30 COM30 B20 A20 CH32 COM32 B19 A19 CH35 COM35 B18 A18 COM37 CH37 B17 A17 CH27 COM27 B21 A21 C24 D24 E24 COM24 COM21 CH21 C21 D21 E21 CH29 COM28 CH28 C20 D20 E20 COM34 COM31 CH31 C16 D16 E16 NC D UT33 D UT32 C15 D15 E15 CH44 COM43 CH43 C13 D13 E13 CH49 COM48 CH48 C11 D11 E11 CH54 COM53 CH53 C10 D10 E10 COM59 COM56 CH56 C9 D9 E9 CH59 COM58 CH58 C8 D8 E8 COM64 COM61 CH61 D7 E7 C7 CH64 COM63 CH63 E6 C6 D6 COM69 COM66 CH66 C5 D5 E5 CH69 COM68 CH68 C4 D4 E4 COM74 COM71 CH71 C3 D3 E3 CH74 COM73 CH73 C2 D2 E2 COM79 COM76 CH76 C1 D1 E1 CH79 COM78 CH78 CH40 COM40 B16 A16 CH42 COM42 B15 A15 CH45 COM45 B14 A14 CH47 COM47 B13 A13 CH50 COM50 B12 A12 CH52 COM52 B11 A11 CH55 COM55 B10 A10 CH57 COM57 B9 A9 CH60 COM60 B8 A8 CH62 COM62 B7 A7 CH65 COM65 B6 A6 CH67 COM67 B5 A5 CH70 COM70 B4 A4 CH72 COM72 B3 A3 CH75 COM75 B2 A2 CH77 COM77 B1 A1 C14 D14 E14 COM49 COM46 CH46 C12 D12 E12 COM54 COM51 CH51 D17 E17 C16 COM41 CH41 CH40 COM37 A17 COM41 CH41 COM44

Accessories Visit ni.com for more information about the following accessories. Table 1. NI Accessories for the NI PXI-2520 Accessory Part Number DIN160 to 50 Pin DSUB switch cable, 1 m 782417-03 DIN160 to DIN160 switch cable, 1 m 782417-02 DIN160 to bare wire switch cable, 1 m 782417-01 Relay replacement kit 782460-10 Compliance and Certifications Safety This product meets the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions AS/NZS CISPR 11: Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. NI PXI-2520 Specifications National Instruments 7

Note For EMC declarations and certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives as follows: 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification To obtain product certifications and the Declaration of Conformity (DoC) for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/ environment/weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/ environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the NI-SWITCH Readme. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. 2013 National Instruments. All rights reserved. 373795A-01 Jan13