System/Imaging Imperfections

Similar documents
Background (~EE369B)

RAD 229: MRI Signals and Sequences

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

Pulse Sequence Design and Image Procedures

Half-Pulse Excitation Pulse Design and the Artifact Evaluation

Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

BOLD fmri: signal source, data acquisition, and interpretation

MRI Metal Artifact Reduction

Pulse Sequence Design Made Easier

Improving high-field MRI using parallel excitation

Advanced MSK MRI Protocols at 3.0T. Garry E. Gold, M.D. Associate Professor Department of Radiology Stanford University

2 Hardware for Magnetic Resonance Imaging

2015 Spin echoes and projection imaging

2014 M.S. Cohen all rights reserved

Pulse Sequences: Rapid Gradient Echo

High Field MRI: Technology, Applications, Safety, and Limitations

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

Hardware. MRI System. MRI system Multicoil Microstrip. Part1

H 2 O and fat imaging

In a typical biological sample the concentration of the solute is 1 mm or less. In many situations,

Image Quality/Artifacts Frequency (MHz)

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

Lab 8 6.S02 Spring 2013 MRI Projection Imaging

1 Introduction. 2 The basic principles of NMR

MR Basics: Module 6 Pulse Sequences

Magnetic Resonance Imaging Principles, Methods, and Techniques

Magnetic Resonance Imaging

Chapter 1. 1 The NMR Spectrometer. 1.1 Components of an NMR Spectrometer The Magnet

Challenges of Field Inhomogeneities and a Method for Compensation. Angela Lynn Styczynski Snyder. Michael Garwood, Ph.D., Adviser

Noninvasive Blood Flow Mapping with Arterial Spin Labeling (ASL) Paul Kyu Han and Sung-Hong Park

MARP. MR Accreditation Program Quality Control Beyond Just the Scans and Measurements July 2005

Encoding of inductively measured k-space trajectories in MR raw data

磁振影像學 MRI 磁振假影與磁振安全 磁振假影. 本週課程內容 Hardware-related Artifacts 盧家鋒助理教授 磁振假影 磁振安全

HETERONUCLEAR IMAGING. Topics to be Discussed:

ISSN X CODEN (USA): PCHHAX. The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain

MRI SYSTEM COMPONENTS Module One

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

RF Pulse Toolkit: Application Specific Design

A. SPECIFIC AIMS: phase graph (EPG) algorithms to cover a wide range of MRI

Weber State University Radiologic Technology 4603

Diffusion and Functional MRI of the Spinal Cord Methods and Clinical Applications

EE225E/BIOE265 Spring 2012 Principles of MRI. Assignment 7. Due March 16, 2012

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

COMMUNICATIONS Volume-Selective Multipulse Spin-Echo Spectroscopy

Acoustic noise reduction of MRI systems by means of magnetic shielding

RF PULSE DESIGN FOR PARALLEL TRANSMISSION IN ULTRA HIGH FIELD MAGNETIC RESONANCE IMAGING. Hai Zheng. B.S., Xi an JiaoTong University, 2005

Gradients. Effects of B0 gradients on transverse magnetisation Similar to figure 10 of Sattler review Progr. NMR 34 (1999), 93

MRI MRI REGISTRY REVIEW PHYSICAL PRINCIPLES OF IMAGE FORMATION ARTIFACTS SUPERCONDUCTIVE MAGNET ANAIBI MOLINA(R) (RT) (MR) (CT) T2 DEPHASING

The Pulsed Resistive Low-Field MR Scanner

Principles of MRI EE225E / BIO265. Lecture 21. Instructor: Miki Lustig UC Berkeley, EECS. M. Lustig, EECS UC Berkeley

MR Basics: Module 8 Image Quality

Saturated Double-Angle Method for Rapid B 1 Mapping

MRI Systems and Coil Technology

MRI: From Signal to Image

MAGNETIC RESONANCE IMAGING

Principios Básicos de RMN en sólidos destinado a usuarios. Gustavo Monti. Fa.M.A.F. Universidad Nacional de Córdoba Argentina

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 July 21.

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

RF Pulse Design. Multi-dimensional Excitation II. M229 Advanced Topics in MRI Kyung Sung, Ph.D Class Business

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

NMR Basics. Lecture 2

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.

NMR Hardware 06/06/2017. Outline. Instrumentation: Magnet. Increasing magnetic field increases Sensitivity, by power of 3/2 Dispersion, linearly

RF and Electronic Design Perspective on Ultra-High Field MRI systems

Magnetic Resonance Imaging and Radio Frequency. Part 1. Produced on behalf of Mid Sussex Amateur Radio Society by M5BTB

functional MRI: A primer

EE469B: Assignment 1 Solutions

Compensation in 3T Cardiac Imaging Using Short 2DRF Pulses

Chapter 2. The Physics of Magnetic Resonance Imaging

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

Resonant Antennas: Wires and Patches

Hadamard Slice Encoding for Reduced-FOV Diffusion- Weighted Imaging

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

RADIOWAVE PROPAGATION: PHYSICS AND APPLICATIONS. Levis, Johnson, Teixeira (ESL/OSU) Radiowave Propagation August 17, / 31

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

SPECIFICATIONS FOR AN MRBR 7.0 TESLA / 210MM ACTIVELY SHIELDED MAGNET SYSTEM

Application Guide & Release Notes

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

Gradient Coil Design and Acoustic Noise Control in Magnetic Resonance Imaging Systems

NMR FACILITY NEWSLETTER

Measurement and Analysis for Switchmode Power Design

Applications Guide. Spectral Editing with SVS. (Works-in-Progress) MAGNETOM TaTs and Verio Systems (3T)

BACKGROUND. ** 78% of all MRI scanners have Image Quality problems. *** *** 25% of all Multi-Channel RF coils have at least one bad channel.

Magnetic Resonance Imaging (MRI)

Inherent Insensitivity to RF Inhomogeneity in FLASH Imaging

SPECIFICATION FOR A 7.0 TESLA/400MM ROOM TEMPERATURE BORE MAGNET SYSTEM

Passive Tracking Exploiting Local Signal Conservation: The White Marker Phenomenon

CHAPTER 1 INTRODUCTION

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Reduced Field-of-View Excitation Using Second-Order Gradients and Spatial-Spectral Radiofrequency Pulses

The promise of high-field MRI. High Field MRI Technology, Applications, Safety, and Limitations. High-field Scanners

Downloaded from by on 02/07/18 from IP address Copyright ARRS. For personal use only; all rights reserved

Gradient hysteresis in MRI and NMR experiments

US 7,327,141 B2 Feb.5,2008

Transcription:

System/Imaging Imperfections B0 variations: Shim, Susceptibility B1 variations: Transmit, Receive Gradient Imperfections: Non-linearities Delays and Eddy currents Concomitant terms 1

B0 Variations - Off-Resonance Imperfections in the B0 field (~1ppm) Coil design Imperfections in coil placement, currents Susceptibility variations (~1-5ppm, normal body) Chemical shift (-3.5ppm for fat, most common) 2

Susceptibility Tendency to be magnetized H field is continuous Η = χβ B0 is convolution of χ with a dipole field 3

Susceptibility Air-tissue interfaces and complex shapes Field can be improved by shimming Measured B0 may still vary considerably (500Hz here) 4! Image Mask B0 Shimmed B0

Chemical Shift Refers to the frequency shift due to electron shielding Reduces the resonance frequency Most common: Fat-Water: -3.5ppm (220Hz at 1.5T / 440Hz at 3T) Actually multiple peaks in fat (more complicated) Many Others ~ Spectroscopy F W 6 4 2 0 (Frequency) ppm 5

Shimming Passive Shimming: Add small materials to correct field Active Shims: Coils with adjustable currents to correct field Linear: Small current usually added to imaging gradient High-Order: z 2 -(x 2 +y 2 )/2, 3zx, 3zy, 3(x 2 -y 2 ), 6xy 6

Minimizing Effects of B0 Variations Spin-echoes: Minimize T2 * dephasing High bandwidths / short readouts: Minimize imaging artifacts Post-processing corrections Fat suppression (eliminate species w/ Chem Shift) 7

B1 Transmit (B1 + ) Variations Coil Inhomogeneities (minimal with Birdcage) Dielectric effects (worse at high fields - shorter wavelengths, standing waves) RF amplifier non-linearity (small, harmonics) 3.0T 4.0T 7.0T 3T Images courtesy G. Glover, Stanford Univ 4T Images courtesy C. Charles, Duke Univ. 9/2000 7T Images courtesy T. Vaughan, M. Garwood, Univ. Minn. 6/2000 8

Minimizing Effects of B1 + Variations Better coil profiles B1 shimming: Adjust amplitude/phase of transmit currents Measure B1 and compensate signal, measurement Parallel transmit (multiple B1 + fields) B1-insensitive pulses (adiabatic, BIR4,...) 9

B1 - Receive Primarily coil sensitivity variations Somewhat fixable in reconstruction Measure sensitivities (SENSE) Surface-coil intensity correction Coil 1 Coil 2 Coil 3 Coil 4 Coil 5 Coil 6 Coil 7 Coil 8 All Coils 10

Gradient nonlinearity Ideally, linear mapping of position to Bz Must end somewhere(!) db/dt limited too Distortion of image Loss of resolution Aliasing 11

Gradient Non-linearity Correction Apply grad-warp warping to correct distortion Note image boundaries are curved 12 Marc Alley

Gradient Non-linearity and B0 Variation B(z) = B Gz (r)+ B 0 (r) Axial If B(r1) = B(r2), positions are indistinguishable Aliasing or Annefact (if RF coil sensitive in region) Applies to slice selection too: Can correct slice location Warps slice (harder to fix) Saggital 13 Marc Alley

Example: B0 and Gradient Nonlinearity Where does this point alias to? 14

RF / Gradient Delays Amplifier delays, circuit delays Can vary between scanners but also calibrated Cartesian imaging insensitive, but other methods much more affected Gradient delays can be axis-dependent RF transmit and receive delays can vary 15

Delay Questions How do these delays affect standard imaging: Slice select gradient delay (general)? Dephasing/signal loss (refocusing gradient not aligned) Readout gradient delay of 2 samples? 2 cycles of linear phase in readout direction Phase-encode gradient delay of 2 readout samples? Not noticeable (possibly affects 2 outer kx-space samples) 16

Eddy Currents Generated by gradient switching, subject independent Linear system models (dg/dt): B 0 (! r,t)= X h i (! r,t) G i (t) i=x,y,z Spatially-independent terms (global phase/rotation) Linear terms ~ gradient errors (self, cross axis) Higher-order terms - hardest to correct 17

Concomitant Gradients B c (x, y, z) = 1 2B 0 G 2 xz 2 + G 2 yz 2 + G 2 z x 2 + y 2 4 G x G z xz G y G z yz Maxwell terms - impossible to create Bz variation without some Bx and By variation Bigger problem at lower field strengths Some correction schemes (From Bernstein, MRM 39:300 (1998) 18

Summary: System Imperfections B0 variations: Shim, Susceptibility B1 variations: Transmit, Receive Gradient Imperfections: Non-linearities Delays and Eddy currents Concomitant terms 19