Valve amplifier for proportional valves with electrical position feedback

Similar documents
Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional pressure valves

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Valve amplifier for proportional pressure valves

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Analogue amplifier modules for 4/3 and 4/2 proportional directional valves 4WRE

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Electric amplifier for flow control with proportional

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Electric amplifier for proportional cartridge throttle valves

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

p/q closed-loop control amplifier

RT-5005/5006/5007/5008

4/3 proportional directional valve direct operated, with integrated electronics

RA / /6. Replaces: Table of contents RA /06.98

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Analog amplifier RA. RE Edition: Replaces:

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Service case with test unit for servo and proportional valves with integral electronics (OBE)

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

External control electronics for the SYDFE1 control of A10VSO axial piston pumps Analogue amplifier, configurable

External control electronics for the SYDEF1 adjustment of the A10VSO axial piston pump

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Continental Hydraulics Installation Manual CEM-PA-A

ELECTRONIC REGULATOR FOR OPEN LOOP

DENISON HYDRAULICS Proportional Pressure Control Valves

External control electronics for the SYDFE1 control of the A10VSO axial piston variable displacement pump

4/3-way fast response valve Type 4WRGE

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Directional control valve, direct operated, with integrated digital axis controller (IAC-Multi-Ethernet) Type 4WRPDH. Features.

Smart Power Relay E I...

Proportional directional valves

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Operating Instruction

Proportional amplifier type EV22K5

Operating Instructions

Continental Hydraulics Installation Manual CEM-RA-A

Technical Documentation

Sensor technologies Proximity sensors Series ST9. Brochure

Drive electronics pq11

Coils & Electronic Controls

Pulse Scaler for DIN Rail Attachment

Analog position controller

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

Proportional Directional Control Valves Size 6

Electro-Hydraulic 4-Way Directional Servo Valve Model 4 WS 2 E.10 and 4 WSE 2 E. 10 (Series 4X) PSI (315 bar) K K

Digital axis control HNC100

DEIF A/S. Insulation monitor. Type SIM-Q

Drive Electronics pq11

Proportional amplifier type EV1M3

Accessories Power Amplifiers

Type CP-S, CP-C & CP-A Switch mode

Electronic Circuit Breaker with reset input ESS20-1..

J IPC IGBT power converter

Digital amplifier for proportional valves PEM XD

High Power Piezo Driver

Electronic plugs for valves MSE

Speed sensor DSA series 12

Proportional Directional Control Valves Nominal sizes 16 and 25

Digital axis control. Table of contents. RE 30139/08.12 Replaces: Type VT-HNC100. Component series 3X 1/20

Directional valves Coils Series CO1. Brochure

Proportional amplifier type EV1M3

Mobile dual solenoid driver

Digital electronic TEB/LEB drivers integral-to-valve format, for proportional valves with one or two spool position transducers

Directional control valve, direct operated, with integrated digital axis controller (IAC Multi Ethernet) Type 4WRPDH. Features.

Electronic amplifier type EV1D

PHOENIX CONTACT - 09/2009

Disc Gap Control DGC-2. Technical Manual

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

MDSD (Series 2X) Mobile Dual Solenoid Driver

Electronic Circuit Breaker ESS1 for System SVS1

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

RT100 Multi-axis Joystick Controller. RunnTech

Amplifier / controller electronics

SCA-SS (70V, 10A)

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

EFC 3600 Frequency converter for higher energy efficiency and improved process control

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

MINI MCR-SL-UI-f(-SP)

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

PRELIMINARY AVB250A060 PRELIMINARY. Servo Drive. Peak Current (10 seconds)

Transcription:

Valve amplifier for proportional valves with electrical position feedback Type VT-MRPA1-... RE 30221 Edition: 2015-02 Replaces: 2013-08 Component series 1X Analog, modular design Intended for controlling direct operated proportional pressure relief valves with electrical position feedback (type DBETR-1X) or proportional flow control valves with electrical position feedback (type 2FRE...) H7076 Features Command value input +10 V (differential input) Ramp generator with separately adjustable ramp time "up/down" Zero point potentiometer Amplitude attenuator Enable input Reverse polarity protection for voltage supply Power supply unit with DC/DC converter without raised zero point Cable break detection in the position transducer branch LED indicators: Ready for operation (green) Enable (yellow) Measuring sockets for: Command value "w" Actual value "x" Ramp times "t <", "t >" Contents Features 1 Ordering codes 2 Functional description 3 Block diagram/pin assignment 4 Technical data 5 Terminal assignment 6 Dimensions 6 Project planning/maintenance instructions/ additional information 7 Setting recommendation 7

2/8 VT-MRPA1-... Valve amplifier Ordering codes 01 02 03 04 05 06 VT-MRPA1 100 1X / V0 / 0 / * 01 Analog amplifier in modular design VT-MRMA1 02 For controlling the valve DBETR-1X 100 For controlling the valve 2FRE6-2X 150 For controlling the valves 2FRE10-4X and 2FRE16-4X 151 03 Component series 10 to 19 (10 to 19: Unchanged technical data and pin assignment) 1X 04 Version: Standard V0 05 Standard option 0 06 Further details in the plain text *

Valve amplifier VT-MRPA1-... 3/8 Functional description General The amplifier modules are snapped onto top hat rails according to EN 60715. The electrical connection is established via screw terminals. The modules are operated at 24 V direct voltage. Power supply unit [1] The amplifier modules have a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. The making current limiter prevents high making current peaks. Command value presetting The internal command value signal is calculated from the total [3] of the external command value signal available at the differential input [2] and the zero point offset (zero point potentiometer "Zw"). A positive command value results in a current increase in the solenoid and thus a pressure increase in the valve. Enable function [11] The enable function enables the power output stages and forwards the internal command value signal to the ramp generator. The enable signal is displayed by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value presetting) by the set ramp time. Thus, a controlled valve does not open abruptly. Ramp generator [4] The ramp generator limits the rise of the control output. The amplitude attenuator does not extend or shorten the ramp time. Notice for setting and measuring the ramp time: Amplitude attenuator [5] By means of the amplitude attenuator "Gw", the maximum value can be adjusted to the hydraulic requirements in a range between 0 and 100%. Amplitude limiter [6] The internal command value is limited to 0% and 110%. Oscillator [9] The oscillator creates the control signal for the inductive position transducer. Demodulator [10] The demodulator supplies the actual value signal of the valve spool position from the position transducer signal: +100% +10 V at the measuring socket "x". Controller for the valve spool position [7] The position controller is intended to minimize the valve hysteresis and is optimized in a valve-specific manner. Power output stage [8] The power output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to approx. 1.85 A. The output stage output is shortcircuit-proof. The output stage is de-energized in case of an internal fault signal or if the enable signal is missing. Fault recognition [14] The position transducer cable is monitored for cable break and over-current at the output stage. [ ] = References to the block diagram on page 4 Value at measuring socket "t <" or "t >" U t in V 5 3 2 Current ramp time (±20%) t in ms 20 33 50 U t in V 1 0.5 0.3 0.2 0.1 0.05 0.03 0.02 t in ms 100 200 333 500 1000 2000 3333 5000 The following applies: t = Example: 100 V ms U t measured U t = 5 V 100 V ms results in t = 5 V = 20 ms RE 30221, edition: 2015-02, Bosch Rexroth AG

4/8 VT-MRPA1-... Valve amplifier Block diagram/pin assignment Differential input (Ucommand) Command value: 0...+10 V Reference potential + IN IN 5 u 4 Enable 3 + U B Operating voltage 0 V 1 2 Zw Zero point command value Zx Zero point actual value t < Ramp time "up" t > Ramp time "down" Gw Amplitude attenuator Gx Sensitivity actual value w Command value x Actual value Ready for operation Enable 2 u L0 DC 3 S Zw 11 1 t < t < 6 4 G max w U B 5 8 M0 u i 7 Solenoid 8 t > t > Gw 12 & PID 10 7 9 = 11 14 x 2 U B 10 1 13 M0 6 DC + 15 V + 10 V M0 10 V 15 V Gx Zx Notice: When exchanging VT 11025, VT 11033 or VT 11034, please observe the different terminal assignment of the position transducer connector. Terminal "6" and "12" are swapped. = 12 1 Power supply unit 2 Differential amplifier 3 Command value summing device 4 Ramp generator 5 Amplitude attenuator 6 Amplitude limiter 7 Controller for valve spool position 8 Power output stage 9 Oscillator 10 Demodulator 11 Enable function 12 Proportional valve 13 Inductive position transducer 14 Fault recognition

Valve amplifier VT-MRPA1-... 5/8 Technical data (for applications outside these parameters, please consult us!) Operating voltage U B 24 VDC + 40% 20% Operating range: Upper limit value u B (t) max 35 V Lower limit value u B (t) min 18 V Power consumption P S < 24 VA Current consumption I < 2 A Fuse Thermal overload protection (with restart if the value falls below the temperature threshold) Inputs: Analog Command value (differential input "±IN") U e 0 to +10 V; R e > 50 kω Digital Enable ON U 8.5 V to U B ; R e > 100 kω OFF U 0 to 6.5 V; R e > 100 kω Setting ranges: Zero point command value (potentiometer "Zw") ±10% Zero point actual value (potentiometer "Zx") ±10% Ramp times (potentiometer "t <" and "t >") t 20 ms to 5 s Amplitude attenuator (potentiometer "Gw") 0% to 110% (applies to the zero point setting = 0%) Outputs: Power output stages I 0 to 1.85 A; short-circuit-proof; clocked approx. 5 khz Oscillator U SS 2 V; 10 ma per output f 5.6 khz ± 10% Measuring sockets Ramp time "t <" U 20 mv to 5 V Ramp time "t >" U 20 mv to 5 V Actual value "x" U 0 to +10 V Command value "w" U 0 to +10 V Type of connection 12 screw terminals Type of mounting Top hat rail TH 35-7.5 according to EN 60715 Protection class IP 20 according to EN 60529 Dimensions (W x H x D) 40 x 79 x 85.5 mm Admissible operating temperature range ϑ 0 to +50 C Storage temperature range ϑ 25 C to +70 C Weight m 0.14 kg Notice: For information on the environment simulation testing for the areas EMC (electro-magnetic compatibility), climate and mechanical load, see data sheet 30221-U. RE 30221, edition: 2015-02, Bosch Rexroth AG

6/8 VT-MRPA1-... Valve amplifier Terminal assignment Operating voltage +U B 1 7 0 V 2 8 Solenoid Connection cable (recommendation): 2-wire cable, single shielded, cross-section 1.5 mm 2 Enable U F 3 9 Free IN 4 10 Differential input Position transducer return feed +IN 5 11 2 1 6 12 Position transducer control 3-wire cable, single shielded, cross-section 1.5 mm 2 max. Dimensions (dimensions in mm) Top hat rail TH 35-7.5 according to EN 60715 LED indicators: Ready for operation (green) 79 85,5 7 1 8 9 10 11 12 REXROTH VT-MRPA1-100 2 3 Gw Zw Gx Zx t < t > t < t > x w ^ ^ 40 4 5 6 Enable (yellow) Potentiometer: Gw Amplitude attenuator for positive command values Gx Sensitivity adjustment of positional transducer (pre-set) Zw Zero point command value Zx Zero point actual value t < Ramp time for increasing command values t > Ramp time for decreasing command values Measuring sockets: t < Ramp time "up" t > Ramp time "down" x Actual value w Command value Measurement zero

Valve amplifier VT-MRPA1-... 7/8 Project planning/maintenance instructions/additional information The amplifier module may only be wired when de-energized. Do not lay lines close to power cables. Do not use free-wheeling diodes in the solenoid conductors. The distance to aerial lines, radios, and radar systems has to be 1 m at least. Always shield command value and position transducer lines; connect shielding to protective earthing (PE) on the module side. In some cases (e.g. if PE is subject to strong interference) it can be necessary to connect the shield of the position transducer line directly to the LO of the amplifier module; other side open (risk of ground loops). Recommendation: Also shield solenoid conductors! For solenoid lines up to a length of 50 m, use cable type LiYCY 1.5 mm 2. For longer lines, please consult us. Do not connect terminal " " of the position transducer connector to "PE". For switching command values, relays with gold-plated contacts have to be used (low voltages, low currents). Only carry out measurements at the module using instruments with R i > 100 kω With a strongly fluctuating operating voltage, it may in the individual case be necessary to use an external smoothing capacitor with a capacity of at least 2200 µf. Recommendation: Capacitor module VT 11110 (see data sheet 30750); sufficient for up to 3 amplifier modules Notice: When exchanging VT 11025, VT 11033 or VT 11034, please observe the different terminal assignment of the position transducer connector. Terminals "6" and "12" are swapped. Setting recommendation The system-specific circuitry must have been completed. Signal Command value zero point Actual value zero point Ramp times Maximum value (amplitude attenuator "Gw") Setting MRPA1 Apply enable signal Preset the external command value to zero Set the internal command value to zero using the "Zw" zero point potentiometer and carry out a check at measuring socket "w" Enable signal "OFF" or pull solenoid plug (valve moves to mechanical end position) For all settings, observe polarity of measuring device measuring sockets Set ramp time according to formula or table (see functional description "Ramp generator") and check it at the "t >" and "t <" measuring sockets Notice: Before comparing the maximum value, the zero point must have been set correctly. Preset command value = 100% Set maximum control output using the "Gw" potentiometer and carry out a check at measuring socket "w" RE 30221, edition: 2015-02, Bosch Rexroth AG

8/8 VT-MRPA1-... Valve amplifier Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.