CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Similar documents
MX1615. Data sheet. Bridge/strain gauge amplifier

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

C10. Data sheet. Force transducer. Special features. B de

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

Inductive Standard Displacement Transducers

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

U2B. Data sheet. Force Transducer. Special features. B en

Multipoint measuring units UPM100 and Centipede100

U9C. Data sheet. Force Transducer. Special features. B en

MX1615B. Data sheet. Bridge/strain gauge amplifier

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

Operating manual. 600 Hz Measuring Amplifier ME30. A en

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

U2B. Force Transducer. Special features. Data sheet

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

MGCplus. Measuring amplifier system. Special features. Data sheet

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

T22. Torque transducer. Special features. Data sheet

C9C. Force Transducer. Special features. Data sheet

Single point load cell

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

T12. Digital Torque Transducer. Data Sheet. Special features. Block diagram signal flow. B en

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

Load cell. Special features. Data sheet

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

MX410B. Highly dynamic universal amplifier. Data sheet. Special features. Block diagram

USB-2404-UI Specifications

Operating manual. Digital Transducer-Electronics AED 9301A. Part 1, Profibus basic device

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

Single point load cell

7600 Isolated Digitizer and Receiver

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

User Manual AED9501A. Digital Transducer Electronics Basic device CANOpen/DeviceNet. I en

SMSTRB. Data Sheet. Strain SMART Module. Special Features. Block Diagram. B en

T12. Data sheet. Digital Torque Transducer. Special features. Signal flow block diagram. B en

MX440B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

MX840B. Data Sheet. Universal amplifier CAN. Special features. Block diagram. B en

T40FH. Torque flange. Special features. Data sheet

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B

T40B. Torque Flange. Special features. Data sheet. Overall concept

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Calibration and Testing

S9M. Force Transducer. Special features. Data sheet

Load Cell Accessories and Services

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

User Manual CTP4/8/16

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Specifications. Measuring Amplifier System. MGCplus. B en

Coupling / decoupling network (CDN) for screened or coaxial cables

Model 140 Inline Amplifier

Specifications. Measuring Amplifier System. MGCplus. B en

Analog Signal Conditioning Accessories

Magnetic absolute multi-turn hollow shaft encoder BMMH MAGRES SSI

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

CSG110 Strain Gauge Universal Amplifier

B850 Boiler House Energy Monitor

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer. SL Series. Key-Features:

EPAD2/CPAD2/CPAD3 Modules. Modules with CAN or RS-485 Interface

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

EBRG. Data Sheet. edaq Bridge Layer. Special Features. Block Diagram. B en

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

PHOENIX CONTACT

MX460B. Data sheet. Pulse and Frequency Measurement Module. Special features. Block diagram. B en

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

SUNSTAR 传感与控制

Schlöder GmbH - EMC Test and Measurement Systems Model #

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Signal Conditioning Amplifier

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

P5201 Universal Programmable Transmitters with Galvanic Isolation

Load pin Heavy Duty with thin film technology from 10 kn Models F5308, F53C8, F53S1

EY-EM 527: Remote I/O module, ecolink527

Telemetrie-Messtechnik Schnorrenberg

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Wind Transmitter First Class Advanced Classified according to IEC ( )

Magnetic absolute single-turn encoder BMSH MAGRES parallel

ULTRASTAB I U Precision

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Weighing Instruments

ELDIO. Data Sheet. edaqlite Digital Input/Output Layer. Special Features. Block Diagram. B en

Transcription:

CANHEAD Data Sheet Special features 10channel amplifier modules for installation close to measuring points Measured data transmission to communication master via field bus Base modules for individual SGs, SG full and half bridges, DC voltage sources Suitable for unlimited cascading Uniform amplifier module for all base module types Connection of amplifier module/base module by simply plugging in Distributed measurement acquisition ML74B communication module/ AP74 connection board MGCplus CANHEAD amplifier modules for individual SGs or transducers 10 measuring channels per module; with CB1014/15 one additional channel for temperature compensation Base module Base module Base module Ethernet, USB, RS232 Amplifier module CAN BUS and power supply Amplifier module up to 12 CANHEADS per bus line Amplifier module max. 250 m B11837.3 en

Specifications Amplifier module Type CA1030 Accuracy class 0.1 Carrier frequency 600 Number of measurement channels Bridge excitation voltage 1) 10 (plus 1 compensation channel) 0.5; 1.0; 2.5 (global changeover for all channels) Measuring ranges mv/v 20; 10; 4 (acc. to bridge excitation voltage) Measurement resolution bits up to 23 Sampling rates 2) 1/s 1; 2; 5; 10; 20; 25; 30; 50; 60; 100; 150; 300 Filter type: Bessel Nom. value (Hz) 3 db (Hz) 1 db (Hz) Delaytime (ms) Internal Sampling rate 4) (Hz) 25 23.2 13.1 13.3 300 10 10.43 5.94 33.3 300 5 5.08 2.90 76.7 150 2.5 2.523 1.439 163.3 75 1.25 1.259 0.718 336.6 37.5 0.6 0.6297 0.359 683.3 18.75 0.15 0.1623 0.0910 1712 300 0.08 0.0811 0.0455 3411 300 0.04 0.0406 0.0227 6814 150 Additional phase delay Number 1 2 3 4 5 6 712 resulting from CANbus data transmission, depending on the number of CANHEADs assigned on the ML74B. ms 6.67 13.33 20.0 26.7 33.3 40.0 80.0 Noise Filter 3) Noise, typ. (peakpeak) of the measuring range Hz % 25 0.015 10 0.009 5 0.006 Power supply (electrically isolated in the amplifier) V 10...36 Insulation resistance (supply to SG connection, CAN bus or housing) V 50 Power consumption Module (without SGs) Module with max. SG count W W typ. 1 typ. 1.8 CAN bus interface Baud rate kbaud 250 Bus length, max. (see table on next page, top) m 250 Number of base modules on the bus, max. Synchronization 12 (=120 channels) 2.5 0.004 1.25 0.003 all the bus nodes are synchronized phaselocked with defined CAN messages Insulation resistance 50 Mechanical system and environment Connection to base module all connections via a 64pin VG strip (DIN 61412) Dimensions (w x l x h), approx. mm 118 x 71 x 23 Weight, approx. g 120 Temperature range Operation Storage 30... + 70 30... + 70 Perm. rel. humidity, noncondensing % 10...90 Degree of protection Maximum configuration per ML74B per MGC system (max. two ML74B) not relevant, as plugin module max. 12 CANHEADs (120 SG measuring points) max. 24 CANHEADs (240 measuring points), any desired number of cascadeable MGCplus 1) When using half bridge (full bridge) with CB1010 and an excitation voltage of 2.5 V, the transducer impedance must be 120 ohms (230 ohms) at least. 2) The data transmission rate of the CANbus is limited to a total of 3,000 values/s. Therefore, if several CANHEADs are connected to the same bus line, the sampling rate of each individual module may be additionally limited (e.g. 5 CANHEADs correspond to 50 channels on one bus line; max. sampling rate: 60 Hz). 3) When used with CB1010 in a halfbridge configuration, the noise is independent of the current filter setting; the filter frequency specification 25 Hz applies. 4) In the CA1030, the sampling rate on the input side is 1200 Hz. Implementation of digital filters requires a reduction of the sampling rate (through repeated averaging and subsampling). This reduced sampling rate is called internal sampling rate. HBM 2 B11837.3 en

Specifications Maximum bus length in m (without drop lines, Thin Media Cable, 0.38 mm 2, ambient temperature < 45 for quarter bridges with... for half bridges with... for full bridges with... for DC voltage measurement 120 Ω 120 Ω 240 Ω 700 Ω 700 Ω 700 Ω 1400 Ω Power consumption per CANHEAD 1) about 1.70 W 1.35 W 1.15 W 1.00 W No. of CANHEADs 2) 12 90 m 125 m 140 m 165 m 11 100 m 140 m 155 m 180 m 10 110 m 155 m 170 m 200 m 9 120 m 170 m 190 m 220 m 8 135 m 190 m 215 m 250 m 7 155 m 220 m 250 m 250 m 6 180 m 250 m 250 m 250 m 5 220 m 250 m 250 m 250 m 4 250 m 250 m 250 m 250 m 1) 2.5 V bridge excitation voltage (most unfavorable case) 2) Bus length computed for the case of all CANHEAD modules concentrated near the end of the bus line (most unfavorable case) Base modules for individual SGs in quarterbridge connection Type CB1014 CB1015 CB1016 Transducer Available versions Each base module is provided with an internal completion resistor. Its resistance value depends on the respective version. 3-wire circuitry 120 Ω 700 Ω 1000 Ω Single SG Max. connection lengths for 3-wire and 4-wire circuitry as per EN IEC 6100045 m 30 Related amplifier module CA1030 4-wire circuitry Number of measurement channels 10 (plus 1 compensation channel) 10 Selectable compensation methods for all channels simultaneously, individually disconnectable or connectable no compensation with compensation with PT100 and polynomial correction 120 Ω Temperature range for PT100 compens. 100... +200 100... +200 Shunt resistor external internal A shunt resistor with certification that can be plugged into a plinth can be cut in to all the measuring points one after the other. Standard misalignment 1 mv/v Miscellaneous Mechanical system and environment CAN BUS connection (male and female connectors) Amplifier installation All the relevant channel and measuring point information is saved in nonvolatile memory. 5pin M12 fixed connector for CAN bus and excitation (as per the DEVICENET specification) 64pin VG socket connector strip Measuring point connection CAGE CLAMP springloaded terminals for line crosssections 0.08... 0.5 mm 2 (AWG 28...20). Plus solder pads for soldering Displays 2 status LEDs Enclosures Aluminum Dimensions (w x l x h), approx. mm 182 x 131 x 40 Weight, approx. g 540 (without CA1030) Protection system IP30 Temperature range Operation Storage 30... +70 30... +70 Perm. rel. humidity, noncondensing % 10... 90 EMC compliance applies with CA1030 amplifier module plugged in RJ45 shielded sockets *) per EN 61326 (if shielded cables and, if required, shielded plugs are used) *) For EMC reasons, we advise agaiunst using RJ11 plugs, that are electromechanically compatible, instead of shielded RJ45 plugs. B11837.3 en 3 HBM

Specifications Base module for SG half and full bridges, measurement of DC sources Type CB1010 Accuracy class % With straingage half and full bridges: 0.1 With measurement of DC voltage sources: 0.2 Transducer Types Excitation Voltage input Measuring range Perm. commonmode voltage (channelchannel; channel housing) Input resistance, symmetrical V DC V MΩ Full and half bridges in regulated 6wire circuitry, DC sources Setting of excitation voltage for full and half bridges via the measuring amplifier 10 45 2 Connection lengths, max. 1) m 30 Mixed operation TID/TEDS All channels individually configurable for full bridge, half bridge or 10 VDC For full and half bridge in zero wire technology With voltage signals, connection to separate cable cores is required Related amplifier module CA1030 2) Number of measurement channels 10 Power consumption W < 0.1 (without transducer and without measuring amplifier) Miscellaneous Mechanical properties and environment CAN BUS connection (male and female connectors) Amplifier installation Measuring point connection Displays Enclosures All the relevant channel and measuring point information is saved in a nonvolatile memory 5pin M12 fixed connector for CANBUS and supply (as per the DEVICENET specifications) Electrical isolation between CANBUS and supply 64pin VG socket connector strip RJ45 shielded sockets 2 status LEDs Aluminum Dimensions (w x l x h), approx. mm 182 x 131 x 40 Weight, approx. g 540 (without CA1030) Protection system IP 20 Temperature range Operation Storage 30... + 70 30... +70 Perm. rel. humidity, noncondensing % 10... 90 EMC compliance, applies for all base modules with plugged in CA1030 amplifier module per EN 61326 (if shielded cables and shielded plugs are used) 1) as per EN IEC 6100045 2) required hardware revision: 1.20 or higher Documentation for the CANHEAD system with ML74B and AP74 is included on the MGC system CD. HBM 4 B11837.3 en

Pin assignment CB1014/1015 CB1014 assignment (threewire circuit) CB1015 assignment (fourwire circuit) B11837.3 en 5 HBM

Pin assignment CB1016 CB1016 assignment (four-wire circuit) Pin assignment CB1010 Full bridge and DC connector assignment 1) 1) In a halfbridge configuration the same assignment applies as in a fullbridge configuration, though wire 4 is omitted, meaning pin 6 is disabled. HBM 6 B11837.3 en

Table of types and scope of supply Amplifier module: CA1030 Base module Completion resistor Quarter bridge / 3-wire Quarter bridge 4-wire Quarter bridge 4-wire Half and full bridges, DC voltage sources (W) Terminal connector RJ45 connector CB1010 120 CB1014120 CB1015120 CB1016120 350 CB1014350 CB1015350 CB1016350 700 CB1014700 CB1015700 1000 CB10141000 CB10151000 Scope of supply Base or amplifier module Mounting instructions With CB1014 and CB1015: 11 cable bushings each Ø5.2 mm and 7.5 mm Accessories, to be ordered separately: Order number: CANBUS: T-piece 1-CANHEAD-M12-T M12 male and female connector 1-CANHEAD-M12 M12 CAN termination resistor 1-CANHEAD-TERM 2 m connection cable 1-KAB267-2 (Devicenet cable, with integral connectors for setting up a CAN line) Cable by the meter 4-3301.0180 ML74B 1-ML74B (see documentation for MGCplus) AP74 1-AP74 (see documentation for MGCplus) CANHEADdirect 1-CANHEAD-DIRECT Mounting set 1-CANHEAD-MOUNT consisting of 1 pc. adapter frame with strain relief for the measurement cable and 2 pc. adapter lugs to be mounted on side Measuring point connection for CB1010: Connection cable with loose ends and 8pin RJ45 connector, 3 m long Adapter cable (RJ45/DSUB 15pin) 1-KAB156-3 1-KAB417 IP65 housing B11837.3 en on request 7 HBM

Modifications reserved. All product descriptions are for general information only. They do not represent any form of guarantee under the law and constitute no form of liability. B11837.3 en HOTTINGER BALDWIN MESSTECHNIK GmbH Postfach 10 01 51, 64201 Darmstadt, Germany Im Tiefen See 45, 64293 Darmstadt, Germany Tel.: 061 51/ 8 03-0; Fax: 061 51/ 8039100 Email: support@hbm.com www.hbm.com