Table K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Similar documents
Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220

Technical Data Sheets

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

TOSHIBA International Corp

+ 24V 3.3K - 1.5M. figure 01

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Powerware 9155 UPS Seismic Kit Installation Instructions

90-NET. Series CHLORIDE POWER PROTECTION. THREE PHASE Uninterruptible Power System. Owner s Manual. P/N 10H52171UM01 Rev. 3

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

Installation. Symmetra MW II kw 480 V

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Datawave Magnetic Synthesizer

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

NetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Electrical Wiring: Commercial, Seventh Canadian Edition

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Power Processor - Series 700F 10KVA to 150KVA

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

TECHNICAL DATA SHEET B9600FXS kva

HPS Universal BUCK-BOOST TRANSFORMERS

POWER SERVICE DETAILS

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

SINGLE-PHASE VSV SWITCH

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

Short-Circuit Current Calculations

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

Installation requirements

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Impact Assessment Generator Form

CP /240-MC4 User Manual

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Electronic Circuit Protector ESX10-T

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

Embedded Generation Connection Application Form

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

5570M Series Intercom Installation and Operation Guide

Steps for Selecting the Proper Transformer

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Gutor PxW AC UPS Designed for North American Market

Variable Transformers Product Design & Engineering Data

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

MAJORSINE Power Inverter

Grounding and Bonding

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Article 250 Grounding & Bonding

Installing the IPS 4240 and the IPS 4255

American Electrical Institute

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

Installation Guide. Grid Tie Interface (GTI) SW Series SW4024, SW4048, SW5548

AXA 2400 COMPACT & 90 kva solid-state GPU

Short Circuit Current Calculations

3Ø Short-Circuit Calculations

Distribution/Substation Transformer

Wiring of the Main Distribution Panelboard

SINGLE-PHASE VSV SWITCH

200 Watt Passive Shunt Module

BUCK-BOOST TRANSFORMERS

InfraStruXure Manager v4.x Addendum: Building Management System Integration

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Warehouse Stock Transformers

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Embedded Generation Connection Application Form

BFS / BFSM SERIES Installation & Maintenance Manual

Atkinson Dynamics Intercom Model AD-28X-MV Installation and Service Instructions

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

M302RM OPERATING MANUAL

Electronic Circuit Breaker ESS1 for System SVS1

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

Howard Smart Transformer Specification Guide

DPC F - P3-24. Part Number Scheme. Dimensions

2. Determine the number of Modules/Microinverters required. (1134 modules is 2 less than 250 KW but works well with max comm.

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

Electromagnetic Harmonic Filters Technical Guide

GESS Industrial UPS System. Overview

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

Open Type Without Enclosure

Installing a Center Stage Switch in an Avaya MCC1 Media Gateway

Connection Impact Assessment Application

Anacon Power & Controls Relay Assembly Specialists An Anacon Electronic Sales, Inc. Company

Wisconsin Contractors Institute Continuing Education

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

Anacon Power & Controls

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

(267 kw THROUGH 735 kw)

Transcription:

Table K. Input/ Ratings & External Wiring Requirements for the 9390-/ Units Rating 50/0 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Rectifier (0.98 min. pf) plus Recharge Current A (3) Phases, Ground Number per Phase Bypass (3) Phases, Neutral-if required, Ground B Number per Phase Input from to UPS Positive, Negative Number per Pole to Critical Load (3) Phases, Neutral-if required, Ground Number per Phase Neutral Bonding Jumper Number (See Note 7) C D - kva kw VOLTS VOLTS 3 3 400 400 4 4 Amps 240 135 130 125 105 (2) Amps 222/210 122 11 111 9 Vdc Amps@ (2.0V/cell) (2) 384-4 203 432-4 203 432-4 203 432-4 203 432-4 203 Amps 222/210 122 11 111 9 NOTE Callout letters A, B, C, and D map to Drawing 1420103-5, sheets 1 of, 4 of, 5 of, and of. (2) of 23 D 07108 A-18 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

10. Terminals are UL and CSA rated at 90 C. Refer to Table L through Table N for power cable terminations, and Table O for conduit requirements. Drawing 1420103-9 shows the location of the power cable terminals inside the UPS cabinet. Table L. UPS Cabinet Power Cable Terminations for the 9390-/40, 9390-/50, 9390-/0, and 9390-/ (208V/220V Input and 208V/220V ) Terminal Function Terminal Function Tightening Size of Pressure Type Torque Termination Screw Nm (lb in) Rectifier E Phase A 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex and Bypass E7 Phase B 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex (Single Input) E8 Phase C 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex Rectifier E1 Phase A 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex (Dual Input) E2 Phase B 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex E3 Phase C 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex Input To Bypass E Phase A 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex (Dual Input) E7 Phase B 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex E8 Phase C 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex Single Feed To Dual Feed Rectifier Phase A N/A 12.5 (110) M8 Hex Bolt Remove Jumpers between Bypass Phase A N/A 22. (200) M10 Hex Bolt Rectifier Input Terminals and Bypass Input Rectifier Phase B N/A 12.5 (110) M8 Hex Bolt Terminals Bypass Phase B N/A 22. (200) M10 Hex Bolt Rectifier Phase C N/A 12.5 (110) M8 Hex Bolt Bypass Phase C N/A 22. (200) M10 Hex Bolt to E9 Phase A 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex Critical Load E10 Phase B 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex E11 Phase C 2 - #-250 kcmil 42.4 (375) 5/1 in. Hex Input from E4 Positive 1 - #-350 kcmil 31.1 (275) 5/1 in. Hex to UPS E5 Negative 1 - #-350 kcmil 31.1 (275) 5/1 in. Hex Input and Neutral E12 Neutral 8 - #2-00 kcmil 5.5 (500) 1/2 in. Hex Customer Ground Ground Ground 8 - #14-5. (50) Slotted NOTE Customer ground can be run in any conduit listed in Table O. 7 of 23 B 11010 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality A-19

Table N. UPS Cabinet Power Cable Terminations for the 9390-/40, 9390-/50, 9390-/0, and 9390-/ (3V/400V/V/4V Input and 3V/400V/V/4V ) Terminal Function Terminal Function Rectifier and Bypass (Single Input) Rectifier (Dual Input) Input To Bypass (Dual Input) Single Feed To Dual Feed Remove Jumpers between Rectifier Input Terminals and Bypass Input Terminals to Critical Load Input from to UPS Size of Pressure Termination Tightening Torque Nm (lb in) Type Screw E Phase A 1 - #14-13.5 (120) 3/1 in. Hex E7 Phase B 1 - #14-13.5 (120) 3/1 in. Hex E8 Phase C 1 - #14-13.5 (120) 3/1 in. Hex E1 Phase A 1 - #14-13.5 (120) 3/1 in. Hex E2 Phase B 1 - #14-13.5 (120) 3/1 in. Hex E3 Phase C 1 - #14-13.5 (120) 3/1 in. Hex E Phase A 1 - #14-13.5 (120) 3/1 in. Hex E7 Phase B 1 - #14-13.5 (120) 3/1 in. Hex E8 Phase C 1 - #14-13.5 (120) 3/1 in. Hex Phase A N/A 5. (50) 1/4 20 Hex Nut Phase B N/A 5. (50) 1/4 20 Hex Nut Phase C N/A 5. (50) 1/4 20 Hex Nut E9 Phase A 1 - #14-13.5 (120) 3/1 in. Hex E10 Phase B 1 - #14-13.5 (120) 3/1 in. Hex E11 Phase C 1 - #14-13.5 (120) 3/1 in. Hex E4 Positive 1 - #-350 kcmil 31.1 (275) 5/1 in. Hex E5 Negative 1 - #-350 kcmil 31.1 (275) 5/1 in. Hex Input and Neutral E12 Neutral 4 - #14-5. (50) Slotted Customer Ground Ground Ground 8 - #14-5. (50) Slotted NOTE Customer ground can be run in any conduit listed in Table O. 9 of 23 C 07108 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality A-21

Table O. Power Cable Conduit Requirements (continued) Number of Minimum Conduit Number of UPS Model Voltage Terminal Wires in Trade Size (inches) Conduits Conduit 4 2 1/2 1 9390-/0 9390-/0 9390-/ 9390-/ 3/ / 4 3/ / 4 3 1 1/2 1 4 2 1 5 2 1 5 2 1 3 1 1/2 1 4 2 1/2 2 5 2 1/2 2 5 2 1/2 2 3 2 1 4 2 1/2 1 3 2 1 12 of 23 B 11010 A-24 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

Table O. Power Cable Conduit Requirements (continued) Number of UPS Model Voltage Terminal Wires in Conduit 9390 /0 9390 / 3/ 400/ 3/ 400/ Minimum Conduit Trade Size (inches) Number of Conduits 4 2 1/2 1 3 2 1 4 2 1/2 1 3 2 1 14 of 23 C 07108 A-2 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

14. External overcurrent protection is not provided by this product, but is required by codes. Refer to Table F through Table K for wiring requirements. If an output lockable disconnect is required, it is to be supplied by the user. 15. Table P lists the maximum rating for input circuit breakers. When wiring a single feed input, the rating requirements for the input circuit breakers are superceded by the ratings listed in Table Q. Table P. Maximum Input Circuit Breaker Ratings Input Voltage Rating UPS Model % Rating 208V/220V 3V 400V V 4V 9390/9390IT-40/20 9390/9390IT-40/30 9390/9390IT-40/40 9390-/40 9390-/50 9390-/0 9390-/ % 90A 50A 50A 45A 45A 100% 70A 40A 40A 35A 35A % 125A 70A 70A 0A 0A 100% 100A 0A 0A 50A 45A % 175A 90A 90A A 70A 100% 150A A A 70A 0A % 225A 110A 110A 100A 100A 100% 175A 90A 90A 90A A % 250A 150A 125A 125A 125A 100% 200A 110A 110A 100A 90A % 350A 175A 175A 175A 150A 100% 300A 150A 150A 150A 125A C A U T I O N To reduce the risk of fire, connect only to a circuit provided with maximum input circuit breaker current ratings from Table P in accordance with the National Electrical Code, ANSI/NFPA 70. 1. Source protection for the input to bypass should be treated as if supplying an kva three phase transformer, to allow for inrush current if an I with a transformer is installed. Bypass input wiring and bypass input breaker rating should be treated as if supplying an kva load, regardless of the rating of the UPS. 17. The line to line unbalanced output capability of the UPS is limited only by the full load per phase current values for output to critical load shown in Table F through Table K. The recommended line to line load unbalance is 50% or less. 15 of 23 C 07108 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality A-27

18. Bypass and output overcurrent protection and bypass and output disconnect switches are to be provided by the user. Table Q lists the maximum rating for bypass and output circuit breakers satisfying the criteria for both. Table Q. Maximum Bypass and Circuit Breaker Ratings Voltage Rating UPS Model % Rating 208V/220V 3V 400V V 4V 9390/9390IT-40/20 9390/9390IT-40/30 9390/9390IT-40/40 9390-/40 9390-/50 9390-/0 9390-/ % 90A 50A 50A 45A 45A 100% 70A 40A 40A 35A 35A % 125A 70A 70A 0A 0A 100% 100A 0A 0A 50A 45A % 175A 90A 90A A 70A 100% 150A A A 70A 0A % 225A 110A 110A 100A 100A 100% 175A 90A 90A 90A A % 250A 150A 125A 125A 125A 100% 200A 110A 110A 100A 90A % 350A 175A 175A 175A 150A 100% 300A 150A 150A 150A 125A 19. There is no disconnect device within the standard UPS. 20. An external battery disconnect device is recommended, and may be required by NEC or local codes when batteries are remotely located. The battery disconnect device should be installed between the battery cabinet and the UPS. 21. The 9390IT UPS model with internal battery configuration has an internal battery breaker for disconnecting the internal battery supply. See Drawing 1420103-12 on A-7. C A U T I O N Every battery cabinet must have a UVR type circuit breaker with an auxiliary contact. Failure to use this type of circuit breaker may cause severe damage to the UPS and create a personnel hazard. Note that all battery cabinets provided by the UPS manufacturer have this circuit breaker as a standard feature. 22. External input overcurrent protection and disconnect switch for the remote battery location is to be provided by the user. Table R lists the maximum rating for continuous duty rated circuit breakers satisfying the criteria for both. 1 of 23 D 021509 A-28 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

Table R. Maximum Input Circuit Breaker Ratings UPS Model Input Voltage Rating 208V/220V 3V 400V V 4V 9390/9390IT-40/20 100A 100A 100A 100A 100A 9390/9390IT-40/30 125A 125A 125A 125A 125A 9390/9390IT-40/40 150A 150A 150A 150A 150A 9390-/40 9390-/50 200A 200A 200A 200A 200A 9390-/0 250A 250A 250A 250A 250A 9390-/ 300A 300A 300A 300A 300A 23. voltage is computed at 2 volts per cell as defined by Article 4 of the NEC. Rated battery current is computed at 2 volts per cell. 24. The battery wiring used between the battery and the UPS should not allow a voltage drop of more than 1% of nominal voltage at rated battery current. 25. If the conductors used for input from the battery cabinets to the UPS are those provided by the UPS manufacturer, and the UPS and battery cabinets are manufactured by the same supplier, then it is acceptable if they do not meet the noted minimum conductor sizes. 2. Parallel system UPM and system bypass input feeds must come from the same source. 27. Parallel UPM input wiring size requirements and output wiring size requirements from the UPMs to the tie cabinet or distribution panel are the same as listed in Table F through Table K. 28. All 20 kva and 30 kva parallel systems must be wired as for 40 kva. 29. If the load requires a neutral, a bypass source neutral must be provided. If the load does not require a neutral and there is no neutral conductor connected at the bypass input, a neutral to ground bonding jumper must be installed. Install neutral conductors from the UPMs to the common point of connection (tie cabinet), and then install a system neutral to ground bonding jumper. If the recommended installation method cannot be accomplished, each UPM should have a separate neutral to ground bonding jumper installed in accordance with Note 7. DO NOT install both a source neutral and a bonding jumper. See Table T through Table W for system neutral bonding jumper wire sizes. Bonding jumper must be copper wire. C A U T I O N HIGH IMPEDANCE GROUND SOURCES - If the source of supply is a high impedance ground (IT) type, the input neutral conductor must be connected from the source of supply. If there is no output neutral connected to the UPS, the neutral forming transformer kit (PN 103005400) may be used instead of pulling a neutral from the source. If the load requires a neutral then an input neutral conductor must be pulled into the UPS. In no circumstances shall a neutral to ground bonding jumper be installed in the UPS. 17 of 23 C 11010 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality A-29

C A U T I O N DELTA SOURCES (TN S) - The Eaton 9390 UPS system can be operated only from a delta supply source that is fully floating and if the neutral forming transformer kit (PN 103005400) is installed in the UPS. The UPS cannot be operated from a mid point or end point grounded delta supply source. With this type of supply source, there is no capability to provide an output neutral. In no circumstances shall a neutral to ground bonding jumper be installed in the UPS. C A U T I O N In order to change the 9390 batteries from lead acid to NiCad or from NiCad to lead acid, the internal firmware of the UPS must be changed by your Eaton Service representative. Failure to do so will cause battery pack damage and loss of battery backup capability. IThe 9390IT CANNOT use the NiCad batteries. 30. See Drawing 1420103-9 for UPM terminal locations and Table L, Table M, or Table N for termination requirements. 31. Setup of the CAN Bridge card for parallel operation must be performed by an authorized Eaton Customer Service Engineer. Contact service to schedule a date. 32. For parallel system circuit breaker ratings, see appropriate information in Table S. 33. For parallel system ratings, see the appropriate information in Table T through Table W. Table S. Recommended UPM (MOB), Main (MIS), and Bypass (MBP) Circuit Breaker Ratings Voltage UPM Configuration 208V/220V 3V/400V/V 4V Model MOB MIS MBP MOB MIS MBP MOB MIS MBP 9390/9390IT -40/20 9390/9390IT -40/30 9390/9390IT -40/40 9390-/40 9390-/50 9390-/0 9390-/ 1+1 150 150 150 90 90 90 70 70 70 2+0 and 2+1 150 300 300 90 200 200 70 150 150 3+0 and 3+1 150 450 450 90 300 300 70 200 200 4+0 150 00 00 90 400 400 70 250 250 1+1 200 200 200 110 110 110 2+0 and 2+1 200 350 350 110 225 225 175 175 3+0 and 3+1 200 00 00 110 350 350 250 250 4+0 200 700 700 110 450 450 350 350 1+1 225 225 225 125 125 125 100 100 100 2+0 and 2+1 225 500 500 125 250 250 100 200 200 3+0 and 3+1 225 700 700 125 400 400 100 300 300 4+0 225 1000 1000 125 500 500 100 400 400 1+1 300 300 300 150 150 150 125 125 125 2+0 and 2+1 300 00 00 150 300 300 125 250 250 3+0 and 3+1 300 1000 1000 150 450 450 125 400 400 4+0 300 1200 1200 150 00 00 125 500 500 18 of 23 C 07108 A-30 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

Table W. Input/ Ratings for 9390-/ Parallel System Configuration Units All 1+1 2+0 and 2+1 3+0 and 3+1 4+0 Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Input from UPM for each Module (3) Phases, Neutral, Ground D for each Module Number per Phase for each Module Input to Tie Cabinet Bypass (optional) (3) Phases, Neutral-if required, Ground to Critical Load (3) Phases, Neutral, Ground System Neutral Bonding Jumper Number (See Note 29) Input to Tie Cabinet Bypass (optional) (3) Phases, Neutral-if required, Ground to Critical Load (3) Phases, Neutral, Ground System Neutral Bonding Jumper Number (See Note 29) Input to Tie Cabinet Bypass (optional) (3) Phases, Neutral-if required, Ground to Critical Load (3) Phases, Neutral, Ground System Neutral Bonding Jumper Number (See Note 29) Input to Tie Cabinet Bypass (optional) (3) Phases, Neutral-if required, Ground to Critical Load (3) Phases, Neutral, Ground System Neutral Bonding Jumper Number (See Note 29) kva kw VOLTS VOLTS Rating 50/0 Hz 3 3 400 400 4 4 Amps 222/210 122 11 112 97 See Table H through Table K for wire size. F Amps 222/210 122 11 112 97 G Amps 222/210 122 11 112 97-2 F Amps 444/420 244 232 224 194 G Amps 444/420 244 232 224 194-2 2 2 4 F Amps /30 3 348 33 291 G Amps /30 3 348 33 291 - F Amps 888/840 488 44 448 388 G Amps 888/840 488 44 448 388 - NOTE Callout letters D, F, and G map to Drawing 1420103-5, sheets 4 of, 5 of, and of. (2) 22 of 23 D 07108 A-34 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality

34. Required parallel system wiring length should be in accordance with the following rule, as referenced to the diagram below, to ensure approximately equal current sharing when in Static Bypass mode: (Total length of 1A + 1B) (Total length of 2A + 2B) (Total length of 3A + 3B) (Total length of 4A + 4B) This rule has a tolerance of approximately 10% for the combined input and output wire lengths. If installing only two UPMs in a fully redundant system, this requirement is no longer required, as each UPM is capable of supporting the full bypass requirement. However, this would preclude future expansion. UPM 1 Bypass inputs to UPMs 1A 2A 3A UPM 2 4A UPM 3 s from UPMs 1B 2B UPM 4 3B 4B 23 of 23 B 11010 Eaton 9390 UPS (20 kva) and 9390IT (20-40 kva) Installation and Operation Manual 1420103 Rev 4 www.eaton.com/powerquality A-35