Similar documents

Dual Reversing Module

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Rotary Measurement Technology Incremental Encoders

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Hopper and Drive Components

Hopper and Drive Components

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Self-Powered Counters H7ET

XXXX e. X d.. X X X a

APEM COMPONENTS LIMITED

The World of Motion Control

Absolute encoders - SSI

Rotary Measurement Technology Absolute Encoders, Multiturn

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Rotary Position Technology Incremental Encoders

Emotron FDU 2.0 Variable Speed Drive

Signet 9900 Transmitter

Signet 9900 Transmitter

QL50 Luminescence Sensor


Optical encoder MEC22 HR

FRONT BUMPER KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6

INSTRUCTION, BMRA COUPLING BOLT FIELD KIT

A02H Encoder for Vector Motor Application

Count/Time Totalizers

SPEC Pak. Sealed Power For Environmental Connections. Anderson Power Products. Marine Wind Power Lighting Transportation Pumps Ground Support

XXXX e. X d.. X X X a

Multifunctional counter tico 772/773/774

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Universal Radius Mounting Option. Fixed Radius Mounting Option

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

DMS-20LCD Series. 3½ Digit, LCD Display Low-Cost, Subminiature Digital Panel Voltmeters. Features

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

SBS Connectors - up to 110 amps

High Intensity LED Light Bar - Trunnion U-Bracket - 24, 10-Watt LEDs - 20,640 Lumen VDC

Technical data. General specifications. Measurement range min max. 360

Rotary Measuring Technology

JR12 Jam Nut Mount Optical Encoder

PORTA~TRACE. GAGNE, INC. 41 Commercial Dr. Johnson City, New York Phone: Fax: ASSEMBLY INSTRUCTIONS

parameter conditions/description min typ max units accuracy 0.2 degrees

WLS28-2 LED Strip Light - PWM Dimmable

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

Technical Data Sheet. x1000. kwh R Y B

F l a t S c r e e n A R M S I n s t a l l a t i o n

Signet 9900 Transmitter

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

*MANDATORY SERVICE BULLETIN*

Absolute Encoders - Singleturn

Cylindrical Photoelectric Sensor

MX150L tm INDUSTRIAL SEALED CONNECTOR SYSTEM

Incremental encoders Blind or through hollow shaft ø12 mm pulses per revolution

Direct Digital Control of package units, VAV boxes, and other terminal unit applications. The TCX 840

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Section A Gear Box September A

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

MAGNETIC 2000 SERIES BEARINGLESS ENCODERS FOR LARGE SHAFTS

PRELIMINARY. current/ phase

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

RoHS. High shaft load capacity. Shock / vibration resistant

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

S662 Preset Batch/Dual Counter

Encoder - Absolut 2RMHF-SSI

SBE 320 / SBX 350 Connectors - up to 350 Amps

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

Incremental Encoder Model: FOI58

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required:

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Complete units: Mushroom heads ø 22mm

Complete units: Push-buttons ø 22mm

Easy to replace. A pigtailed type sensor with connector (CY- -J), which is easy to replace, is also available. Environment resistant

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

High Intensity Colored LED Light Emitter - 12, 3-Watt LEDs VDC - IP Lumens

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

[ 21.3 ] 0.84 A [ 13.0 ] 0.51

Absolute Encoders Multiturn

Rotary actuators for ball valves

Smart Power Relay E I...

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Express Delivery. Axial. Connection

Signet Flow Transmitter

User Manual and Specifications for LC-40w Projector. LTBLtech. Loss Prevention for the 21 st Century

Data Sheet MEM 16. Incremental Encoder Magnetic

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

Electrical Specifications

SHAFTED ROTARY POSITION SENSORS

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

Transcription:

SOLID STATE HOUR METERS & COUNTERS 7 0 0 S E R I E S A p p l i c a t i o n s A wide variety of industrial and commercial applications, including scheduled maintenance, warranty and leasing for medical equipment, transport and industrial vehicles and other industrial equipment. D e s c r i p t i o n The Curtis 700 Series are highly reliable solid state hour meters and counters that offer an unprecedented combination of patented technology, performance, reliability and value. MODEL 700: 2-Wire Hour Meter, displays only when powered. Available in AC/DC. MODEL 70: 3-Wire Hour Meter, has a provision or continuous display. Available in AC/DC and DC-only. MODEL 703: Pulse Counter. Available in AC/DC and DC-only. F e a t u r e s All-8 s LCD function test: each digit displays an eight for one second after power-up. Attractive 6-digit LCD 5mm or 7mm high digits (7mm with optional backlighting) are much easier to read than electromechanical meters, which have only 3mm high digits. Silent operation no moving parts. Eliminates annoying gear and motor noise. Exceptional reliability due to nonvolatile memory (EEPROM) which retains data for 25+ years. Wide voltage ranges, for example, one unit can be powered from 75 to 270 VAC anywhere between 48 and 440 Hz ideal for distribution and worldwide markets without having to stock multiple model types. Electrical reset (optional). Available in ten case styles all fit in standard hour meter/counter cutouts. Multiple mountings available Metal U-bracket, U clamp/stud (D, Q, R and S cases), flange mount with hardware (F, T, G, J cases), or mounting clip (G, L, Y, Z, cases). Backlit units allow external illumination control, i.e., on/ off or dimmer (2VDC only). Flashing hourglass icon indicates when the hour meter is accumulating time. Memory will arm only when power has been applied for five seconds (with no loss of time or counts). Low power consumption. UL and CE recognized. CURTIS INSTRUMENTS, INC. 200 KISCO AVENUE MT. KISCO, NY 0549 USA TEL (94) 666-297 FAX (94) 666-288 CURTIS INSTRUMENTS, (UK) LTD. 5 Upper Priory Street Northampton NNPT, England TEL 44 (0) 604-629755 FAX 44 (0) 604-629876 CURTIS INSTRUMENTS INDIA PRIVATE LTD. 99, Ghole road Pune 4004, INDIA TEL 9 (0) 20-553288 FAX 9 (0) 20-553992 www.curtisinstruments.com

S p e c i f i c a t i o n s Case Bezel Lens Case IP Rating Termination UL 5 /CE Suggested Style Shape Material Material Front/Rear panel Cutout mm D Rectangular Acrylic ABS 65/50 3/6 Spade Yes 45.0 x 22.2 F/T Hexagonal Acrylic ABS 65/65 Spade 7 Yes 36.8 x 24. G Hexagonal Acrylic ABS 65/65 Packard (2 pin) 2 Yes 36.8 x 24. J Hexagonal Acrylic ABS 65/65 Packard (4 pin) 3 Yes 36.8 x 24. L Rectangular Polycarbonate Polycarbonate 65/40 Molex 4 Yes 36.8 x 24. Q Round Glass Polycarbonate 65/50 6 /4 Spade Yes ø52 (ø2-/6) R Round Glass Polycarbonate 65/50 6 3/6 Spade Yes ø52 (ø2-/6) (5mm display) R Round Glass Polycarbonate 65/50 /4 Spade Yes ø52 (ø2-/6) (7mm display) S Square Glass ABS 52/50 /4 Spade Yes 45.0 x 45.0 Y Rectangular Acrylic ABS 65/65 Packard (4 pin) 3 Yes 36.8 x 24. Z Rectangular Acrylic ABS 65/65 /4 Spade Yes 36.8 x 24. Display Range & Resolution 6 digit LCD, 5 or 7mm high, 6 o clock viewing angle Hour meters: 99,999.9 hours Counters: 999,999 counts Accuracy Hour meters: 0.% Counters: ± count Humidity 95%, non-condensing at 38 C Operating Temperature Storage Temperature Mechanical Shock Mechanical Vibration Operating Frequency (AC powered units) Memory Current Consumption (Power Terminals) -40 C to +85 C -50 C to +85 C SAE J 378, 55g SAE J 378, 20g 48 to 440 Hz Main power must be applied for 5 seconds to arm memory (with no loss of time/counts). EEPROM, data retained for 25+ years without power. 0.5mA max. @ 5VDC (052D models) 0.8mA max. @ 2VDC (248D models).0ma max. @ 20VAC 2.0mA max. @ 230VAC Input Signal (DC-only) Counters (703 only): 500 Hz. max., 50% duty cycle (ms low, min., between consecutive highs) Input Signal (AC/DC) Hour meters (70 only): Power must be applied for 0.5s, min., to accumulate time. Counters (703 only): Hz. max., 50% duty cycle (500ms low, min., between consecutive highs) Reset 5ms min. at operating voltage. Main power must be applied for a minimum of 250ms prior to reset signal. NOTES:. Mating connector must be installed. 2. Equivalent to Delphi-Packard connector P/N 262000 2-pin. 3. Equivalent to Delphi-Packard connector P/N 5336035 4-pin. 4. Equivalent to Molex connector P/N 43045-042. 5. UL files AU84 and E4575. 6. R(5mm) and Q housings also available in a 65/65 version (see model encodement). 7. F= /4, T= 3/6

M o d e l E N C O D I N g 700 MODEL R Case Style R Resetability 00 Additional Feature O Logo* 052D062A Operating Voltage 700 = (2-wire hour meter, AC/DC only) 70 = (3-wire hour meter, AC/DC or DC-only 703 = (3-wire counter, AC/DC or DC-only) D F/T G J L 2 Q R S Y Z R = Electrically resettable N = Nonresettable 00 = 5mm, non-backlit display (Standard) 09 = Epoxy filled unit (moisture resistant, Q, R (5mm), cases only) 60 = 7mm, backlit display (R or S case only) 70 = 7mm, non-backlit display (R or S case only) O = Curtis Logo N = No Logo 052D = 5-2VDC nom., 4.75-5VDC abs. 248D = 2-48VDC nom., 9-60VDC abs. 4850D = 48-50VDC nom., 36-85VDC abs. 052D062A = 5-2VDC nom., 4.75-5VDC abs. 6-2VAC nom., 5-5VAC abs. 248D2060A = 2-48VDC nom., 9-60VDC abs. 20-60VAC nom., 5-75VAC abs. 4850D00230A = 48-50VDC nom., 36-85VDC abs. 00-230VAC nom., 75-270VAC abs.. Only model offered: 700GN00N248D2060A 2. Only models offered: 700LN00N248D2060A, 700LN00N4850D00230A and 70LN00N248D * Custom logos are available Backlight available on 7mm R or S cases only. W I R I n g G U I D E Case Style pin Pin 2 Pin 3 pin 4 Pin 5 pin 6 D, F, T, J,Q, R (5mm), Y & Z V+ V- I R N/A N/A G V+ V- N/A N/A N/A N/A L V+ V- I N/A N/A N/A R (7mm), S V+ V- R I L N/A V+ Operating voltage V- Common (ground) I Enable (Optional, use operating voltage to power this pin to record elapsed time (70) or increment count (703).) R Reset (Optional, supply with operating voltage when unit is to be reset to 0.) L Lighting control (Optional, 9-5VDC absolute only, regardless of operating voltage.) NC No connection Case Style D 32.0 22. 0 24.3 4 3 44.9 4.3 4.20 48.3

Case Style F/T 28.8 53.2 MAX. 8.0 3.2.5 44.5 35.5 3.2 MAX. 4 3 22.7 Ø3.8(2X) Case Style G 53.3 36.6 3.60 2.0 32.6 4.9 2 23.7 23.0 3.4 44.8 Ø 3.8 (2X) 35.8 Case Style J 53.2 MAX. 36.5 8.0 3.2.5 44.5 35.5 3.2 MAX. 3 4 22.7 Ø 3.8 (2X)

Case Style L 3 2 4 24.0 27.5 36.6 4.0 2.80 40.6 2.0 Case Style Y 36.5 8.0 4.7 40.6 3 4 27.5 Case Style Z 28.8 8.0 4.7 40.6 27.5 4 3

Case Style Q QUARTZ 4 3 48.3 0 58.4 8.90 28.6 3.2 Case Style R (5mm) QUARTZ 5.7 0 4 3 58.4 8.90 28.6 3.2 Case Style R (7mm) 9.0 QUARTZ 5 6 5.5 Ø 3 4 45.0 28.0 58.4

Case Style S 44.5 SQUARE 5 6 48.0 3 4 28.0 4.0 48.0 44.0 7 0 0 S e r i e s H A R D W A R E Case Style F, T g, J D, Q, R, S y Z Shipping Style Carton Bulk Carton Bulk Carton Bulk Carton Bulk Carton Bulk Steel Slot Screws 2 2 2 2 Steel Hex Nuts 2 2 2 Plastic Thumb Nuts 2 2 2 Lock Washers 2 2 2 2 2 2 Faston Terminals 4 4 4 Plastic Bracket Metal U Bracket Note: L case does not require hardware. A c c e s s o r i e s Curtis P/N Description 7607303 Plastic mounting bracket for F, T, G, J, Y & Z models 2237003 External Dash Mounting Bracket for 52mm round gauges 32000 Meter Guard ( box of 0 meter guards) R & Q models 35580 3-Hole Mounting Kit, for Ø2.53 mounting holes 355905 3-Hole Mounting Kit, for Ø2.44 mounting holes 5336002 Gasket for F, T, G and J cases 5336003 Gasket for R (5mm) case 5336005 Gasket for Q and R (7mm) cases W A R R A N T Y : Two-year replacement warranty. is a registered trademark of Curtis Instruments, Inc. Specifications subject to change without notice 2004 Curtis Instruments, Inc. 500 REV K 5/07