Load cell 50... 500 kg High capacity single point load cell made of aluminum. EEC approvals in 3000 d according to OIML R60 and up to 5000 d NTEP. Designed to fit with single point platforms of maximum dimensions 800 mm x 800 mm. Off-center load compensated ~ Level of protection IP65 ATEX EC/94/9/CE certified version for potentially explosive atmospheres (option). Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection brown yellow white green grey pink Bestech Australia U14/44 Garden Blvd, Tel: 03 9549 5100 Sales@bestech.com.au Dinely VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Dimensions Specifications Type Variation C3 10e Nominal load ( E ) kg 50; 75; 100; 150; 200; 250; 300; 500 Accuracy class OIML R60 C3 Max. load for approved weighing ( Em a x ) kg 65; 90; 130; 185; 250; 310; 375; 625 Max. number of load cel intervals (nm a x ) d. OIML 3000 Min. verification interval (vm i n ) kg E / 10000 Combined error % E ± 0,017 Creep division factor ( Z = Em a x / 2 x DR ) 5000 Zero balance % E ± 10 Creep error (30 min) % E ± 0,025 Temp. coef. of zero % E / C ± 0,0014 Temp. coef. of sensitivity % E / C ± 0,0014 Nominal range of excitation voltage V 1...15 Nominal sensitivity mv/v 2 ± 10% Input resistance : 410 ± 20 Output resistance : 350 ± 5 Service load % Em a x 150 Limit load % Em a x 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 800 x 800 Tighten torque Nm 40 Level of protection EN60529 IP 65 Insulation resistance G : / 50 V > 1 Material Aluminium - Aluminum Length of wire m 3 Net weight Optionen - Options ATEX 94/9/CE kg 2,1 II 2 G/D, Ex ia IIC T6, Ex iad A21, T80 C Ta<+60 C (zone 1/21) I I 2 D, Ex td A21, IP6X T80 C, Ta<+60 C (zone 21) II 3 G, Ex na IIC T6, Ex nl IIC T6, Ta<+60 C (zone 2) Bestech Australia U14/44 Garden Blvd, Tel: 03 9549 5100 Sales@bestech.com.au Dinely VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Load cell 2,5 kg Single point load cell made of alloy aluminum. EEC approvals in 2000 d according to OIML R60. Designed to fit with single point platforms of max. dimensions 200 mm x 200 mm. Level of protection IP65 ATEX EC/94/9/CE certified version for potentially explosive atmospheres (option). Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection brown yellow white green grey pink Bestech Australia U14/44 Garden Blvd Tel: 03 9540 5100 Sales@bestech.com.au Dingley VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Dimensions Specifications Type Variation C2 3e Nominal load ( E ) kg 2,5 Accuracy class OIML R60 C2 Max. number of load cel intervals d. OIML 2000 (nmax) Min. verification interval (vm i n ) g 1 Max. load for approved weighing (Emax) kg 3,125 Combined error % E ± 0,025 Creep division factor ( Z = Emax / 2 x DR ) 2000 Zero balance % E ± 10 Creep error (30 min) % E ± 0,025 Temp. coef. of zero % E/ C ± 0,007 Temp. coef. of sensitivity % E/ C ± 0,0014 Nominal range of excitation voltage V 1...15 Nominal sensitivity mv/v 2 ± 10% Input resistance : 410 ± 15 Output resistance : 350 ± 5 Service load % Emax 150 Limit load % Emax 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 200 x 200 Tighten torque Nm 6 Level of protection EN60529 IP 65 Insulation resistance G: / 50 V > 2 Material Aluminium - Aluminum Length of wire m 3 Net weight Options ATEX 94/9/CE kg 0,2 II 2 G/D, Ex ia IIC T6, Ex iad A21, T80 C Ta<+60 C (zone 1/21) II 2 D, Ex td A21, IP6X T80 C, Ta<+60 C (zone 21) II 3 G, Ex na IIC T6, Ex nl IIC T6, Ta<+60 C (zone 2) Bestech Australia U14/44 Garden Blvd Tel: 03 9540 5100 Sales@bestech.com.au Dingley VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Load cell 5... 100 kg Single point load cell made of alloy aluminum. Approved up to 3000d OIML R60 and up to 5000d NTEP. Designed to fit with single point platforms of maximum dimensions 400 mm x 400 mm. Ideal for single point scales or batching / dosing machines. Level of protection IP65 ATEX EC/94/9/EC certified version for potentially explosive atmospheres (option). Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection brown yellow white green grey pink
Dimensions Specifications Type Variation C3 5e C3 10e Nominal load ( E ) kg 5 10; 15; 20; 30; 50; 75; 100 Accuracy class OIML R60 C3 Max. number of load cel intervals d. OIML 3000 (nm a x ) Min. verification interval (vm i n ) g 1 1; 1; 2; 2; 5; 5; 10 Max. load for approved weighing (Em a x ) kg 6,25 10; 15; 20; 30; 50; 75; 100 Combined error % E ± 0,017 Creep division factor ( Z = Em a x / 2 x DR ) 3000 Zero balance % E ± 10 Creep error (30 min) % E ± 0,024 Temp. coef. of zero % E/ C ± 0,0028 ± 0,0014 Temp. coef. of sensitivity % E/ C ± 0,0014 Nominal range of excitation voltage V 1...15 Nominal sensitivity mv/v 2 ± 10% Input resistance : 410 ± 15 Output resistance : 350 ± 5 Service load % Em a x 150 Limit load % Em a x 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 400 x 400 Tighten torque Nm 15 Level of protection EN60529 IP 65 Insulation resistance G: / 50 V > 1 Material Aluminium - Aluminum Length of wire m 3 Net weight Options ATEX 94/9/CE kg 0,2 II 2 G/D, Ex ia IIC T6, Ex iad A21, T80 C Ta<+60 C (zone 1/21) II 2 D, Ex td A21, IP6X T80 C, Ta<+60 C (zone 21) II 3 G, Ex na IIC T6, Ex nl IIC T6, Ta<+60 C (zone 2)
Load cell High capacity single point load cell made of aluminum. Approved up to 3000d OIML R60 and up to 5000d NTEP. Designed to fit with single point platforms of maximum dimensions 700mm x 700mm (offcenter load compensated). Extreme flat designed, height: only 47mm. Level of protection IP65. 75... 635 kg Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection brown yellow white green grey pink
Dimensions Specifications Type Variation C3 10e Nominal load ( E) kg 75; 100; 150; 200; 300; 500; 635 Accuracy class OIML R60 C3 Max. number of load cel intervals d. OIML 3000 (nmax) Min. verification interval (vm i n ) kg Emax /10000 Max. load for approved weighing (Emax) kg 75; 100; 150; 200; 300; 500; 635 Combined error % E ± 0,017 Creep division factor ( Z = Emax / 2 x DR ) 3000 Zero balance % E ± 10 Creep error (30 min) % E ± 0,025 Temp. coef. of zero % E/ C ± 0,0014 Temp. coef. of sensitivity % E/ C ± 0,0014 Nominal range of excitation V 1...15 voltage Nominal sensitivity mv/v 2 ± 10% Input resistance : 410 ± 20 Output resistance : 350 ± 5 Service load % Emax 150 Limit load % Emax 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 700x700 Tighten torque Nm 40 Level of protection EN60529 IP 65 Insulation resistance G : / 50 V > 1 Material Aluminium - Aluminum Length of wire m 3 Net weight Options kg 1,55 - ATEX 94/9/CE II 2 G/D, Ex ia IIC T6, Ex iad A21, T80 C Ta<+60 C (zone 1/21) II 2 D, Ex td A21, IP6X T80 C, Ta<+60 C (zone 21) II 3 G, Ex na IIC T6, Ex nl IIC T6, Ta<+60 C (zone 2)
Load cell High capacity single point load cell made of aluminum. Approved up to 3000d OIML R60. Designed to fit with single point platforms of maximum dimensions 1000 mm x 1000 mm (for a use in scale with max. capacity of 1000 kg offcenter load compensated). Extreme flat designed, height: only 68 mm. Level of protection IP65. AP1500 1500 kg Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection brown yellow white green grey pink
Dimensions Specifications Type Variation C3 5e Nominal load (E) kg 1500 Accuracy class OIML R60 C3 Max. number of load cel intervals d. OIML 3000 AP1500 (nmax) Min. verification interval (vm i n ) kg Emax /5000 Max. load for approved weighing (Emax) kg 1500 Combined error % E ± 0,017 Creep division factor ( Z = Emax / 2 x DR ) 3000 Zero balance % E ± 10 Creep error (30 min) % E ± 0,025 Temp. coef. of zero % E/ C ± 0,0028 Temp. coef. of sensitivity % E/ C ± 0,0014 Nominal range of excitation V 1...15 voltage Nominal sensitivity mv/v 2 ± 10% Input resistance : 410 ± 20 Output resistance : 350 ± 5 Service load % Emax 150 Limit load % Emax 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 1000x1000* Tighten torque Nm 250 Level of protection EN60529 IP 65 Insulation resistance G : / 50 V > 1 Material Aluminium - Aluminum Length of wire m 3 Net weight Options ATEX 94/9/CE kg 3,8 II 2 G/D, Ex ia IIC T6, Ex iad A21, T80 C Ta<+60 C (zone 1/21) II 2 D, Ex td A21, IP6X T80 C, Ta<+60 C (zone 21) II 3 G, Ex na IIC T6, Ex nl IIC T6, Ta<+60 C (zone 2) *Bis max. 1000 kg - For a use in scale with max. capacity of 1000 kg
Load cell Single point load cell made of alloy aluminum. Measurement resolution up to 30000 divisions. To be used on single point scales with maximum platform dimensions up to 150 mm x 150 mm (0.2 kg model limited to 120 mm x 120 mm ), off-center load compensated. Ideally suited for jewelry, low cost laboratory or counting scales in very small capacities. 0,2... 1,2 kg Supply (+) Signal (+) Signal (-) Supply (-) Connection black yellow white green
Dimensions Specifications Type Nominal load (E) kg 0,2; 0,6; 1,2 Combined error %E ± 0,02 Zero balance %E ± 20 Creep error (2 min.) %E ± 0,02 Temp. coef. of zero %E/ C ± 0,004 Temp. coef. of sensitivity %E/ C ± 0,0014 Nominal range of excitation V 1... 12 voltage Nominal sensitivity mv/v 1 ± 15% Input resistance : 410 ± 20 Output resistance : 350 ± 5 Service load %E 150 Limit load %E 200 Service temp. range C -20... +60 Nominal temp. range C +5... +35 Tighten torque Nm 4 Level of protection EN60529 IP 63 Insulation resistance G : / 50 V 1 Material Aluminium - Aluminum Length of wire m 0,25 Net weight g 50 AR
Load cell Single point load cell made of aluminum Designed to fit with single point platforms of maximum dimensions 600 mm x 600 mm. Ideally suited for platform scales in harsh environments. Designed for weighing of frontally mounted hoppers, tanks... 150 kg Supply (+) Signal (+) Signal (-) Supply (-) Sense (+) Sense (-) Connection red green white blue pink grey
Dimensions PM Specifications Type Nominal load ( E ) kg 150 Combined error % E ± 0,033 Zero balance % E ± 5 Creep error (30 min) % E ± 0,03 Temp. coef. of zero % E/ C ± 0,0060 Temp. coef. of sensitivity % E/ C ± 0,0016 Nominal range of excitation voltage V 1...15 Nominal sensitivity mv/v 1,2 ± 10% Input resistance : 410 ± 20 Output resistance : 350 ± 5 Service load % E 150 Limit load % E 200 Service temp. range C -20... +60 Nominal temp. range C -10... +40 Max. platform dimension mm 600 x 600 Tighten torque Nm 40 Level of protection EN60529 IP 67 Insulation resistance G: / 50 V > 5 Material Aluminium - Aluminum Length of wire m 3 Net weight kg 1,25
Features High Measuring Accuracy Suitable for Medium Load Measurement Compact and Rugged Model Anodized Aluminium Alloy Material Silicon Rubber Sealing Description MLA21 series with Aluminium alloy material is a rugged and accurate load cell suitable for tension-compression load measurement. This single point load cell offers great flexibility and reliability for a wide range of applications with highly competitive pricing. MLA21 is available in standard ranges from 2.5kg to 50kg with an output of mv/v. While the standard Precision is 0.02% FS, you can optionally get OIML C3. The robust construction of MLA21 with its high performance makes it ideal for demanding long term applications. Applications Electronic scales Bin and hopper weighing systems Mechanical scale conversion Hanging Scales OEM scale construction Level and inventory measurement Technical Specifications Capacity: 2.5, 3, 5, 6, 8, 10, 15, 20, 30, 35, 40, and 50kg or other ranges Output: 2.0 ± 0.2mV/V Precision: 0.02% FS (combined LRH error), OIML C3 Creep: ±0.02% FS / 30min Overload rating: 150% FS Excitation: 5 to 15 VDC Zero unbalance: ±1% FS Protection Level: IP65, with cable connection Compensated temp. range: -10 to 40 C Operating temp. range: -20 to +65 C Temp. coefficient of zero: 0.02% FS /10 C Temp. coefficient of span: 0.02% FS /10 C Input resistance: 400±10Ω/ 1065±15Ω Output resistance: 350±5Ω/ 1000±15Ω Insulation resistance: 5000MΩ @ 50VDC Electrical connection: 4-cored shield cable, φ=3.8mm and length=300mm or others Dimensions Wiring Note: All specifications are subject to change without prior notice Ver. 4.5-12/06 Bestech Australia Distributor of Measure X
How to order: model-capacity-output-accuracy-input resistance-cable specifications-other requests(if any) example:161 H-50kg-3mV/V-0.05%fso-410Ω-cable(Φ3.8mm, 4-core shielded PVC cable, 250m Bestech Australia U14/44 Garden Blvd, Tel: 03 9540 5100 Sales@bestech.com.au Dingley VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Bestech Australia U14/44 Garden Blvd, Tel: 03 9540 5100 Sales@bestech.com.au Dingley VIC 3172 Fax: 03 9551 5541 www.bestech.com.au
Bestech Australia U14/44 Garden Blvd, Tel: 03 9540 5100 Sales@bestech.com.au Dingley VIC 3172 Fax: 03 9551 5541 www.bestech.com.au