Z6... Data Sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en 1

Similar documents
Z6... Data sheet. Load cell. Special features. Dimensions (in mm; 1 mm = inches) B en HBM: public 1

Load cell. Special features. Data sheet

RSCC. Data Sheet. Load cells. Special features. Diagram of RSCC load cell. Design: 500 kg to 5 t. Design: 50 kg to 200 kg. B

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

Single point load cell

S9M. Force Transducer. Special features. Data sheet

PW6C. Single point load cells. Special features. Data sheet

Single point load cell

U9C. Data sheet. Force Transducer. Special features. B en

C9C. Force Transducer. Special features. Data sheet

U2B. Force Transducer. Special features. Data sheet

U2B. Data sheet. Force Transducer. Special features. B en

U15. Force transducer. Special features. Data sheet. Installed dimensions of connection variants

U10M. Force Transducer. Special features. Data sheet. Mounting dimensions of the connection variants in mm [inch]

C10. Data sheet. Force transducer. Special features. B de

Data sheet. P3 Top Class BlueLine. P3MBP BlueLine. Ultra-high pressure transducers to 15,000 bar. Special features

T22. Torque transducer. Special features. Data sheet

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Inductive Standard Displacement Transducers

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Data Sheet. Absolute pressure transducer Nominal (rated) pressure 10 bar to 3000 bar. Special features

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

Load Cells Shear beam load cells SIWAREX WL230 SB-S SA

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

TB2. Torque reference transducer. Special features. Data sheet

T40FH. Torque flange. Special features. Data sheet

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS2000S Hermetically sealed bending beam load cell

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Operating manual. Force transducer with strain gage measuring system C9B. A en. hvordan man bruger astrologi med tibetanske medicin

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

T40B. Torque Flange. Special features. Data sheet. Overall concept

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Type PB Load Cell. Approvals OIML approval to C3 (Y = 7 500; Y = for 375 kg capacity)

MX1615. Data sheet. Bridge/strain gauge amplifier

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

SUNSTAR 传感与控制

Force and weight measuring instruments

Terms and expressions for specifying torque transducers

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Installation Guide. English. FS62 Surface Mountable Strain Sensor

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

Multipoint measuring units UPM100 and Centipede100

Load application in load cells - Tips for users

Weighing Instruments

MX1601B. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Operating Manual Series Load Pins

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

MX1615B R. Data Sheet. Ultra-rugged Bridge Amplifier

Bestech Australia U14/44 Garden Blvd, Tel: Dinely VIC 3172 Fax:

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

Bestech Australia U14/44 Garden Blvd, Tel: Dingley VIC 3172 Fax:

Ultrasonic level measuring device, non-contact

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

WATERFLUX 3000 Quick Start

MX840B R. Data sheet. Ultra-rugged universal amplifier CAN. Special features. Block diagram. B en

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Process Protection Acoustic sensors for pump monitoring

WATERFLUX 3000 Quick Start

XXXX e. X d.. X X X a

OPTIFLUX 5000 Technical Datasheet

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Absolute encoders multiturn

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Pressure transmitter for general industrial applications Model A-10

XXXX e. X d.. X X X a

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Absolute Encoders - Singleturn

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

Signal Beacon - LED Series 6162

Magnetic absolute rotary encoder GEL 235 Singleturn, Multiturn up to 28 bits (SSI)

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

Online data sheet AFS60B-S4PA AFS/AFM60 SSI ABSOLUTE ENCODERS

Electronic Thermostat TE-1 Version according to EN

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Flush pressure transmitter For viscous and solids-containing media Model S-11

Online data sheet AFS60E-S1AA AFS/AFM60 SSI ABSOLUTE ENCODERS

Electrical Temperature Measurement

Resistance Thermometers Model Series TR7X0, Sheathed Design

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

Pressure transmitter for general industrial applications Model A-10

Rudder or propeller angular position transmitter KINAX WT720

Technical Data. General specifications. Rated operating distance s n 3 mm

Coil. Coil L 12 VDC 135 C 18 W 7.7 Ω M M 24 VDC 135 C 18 W 31 Ω M AMP Junior (AJ variant) Coil

Operating Instructions for Microwave Level Switch. Model: LNM

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Encoder WDG 58H.

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Absolute encoders multiturn

Transcription:

Z6... Load cell ata Sheet Special features - Welded on metal bellows - Nominal (rated) loads: 5 kg 1 t - Load cells and installation aids made of rust resistant materials - Verifiable up to 6000 parts, test report as per OIML R60 - Six wire circuit - Optimized for parallel connection by off center load compensation - Meets M requirements as per IN N 45501 - Options: x protection designs as per TX 95 imensions (in mm; 1 mm = 0.03937 inches) Z6; Nominal (rated) loads 5 kg...500 kg Z6; Nominal (rated) load 1 t 123 45 18 82 Mounting 10 Load application Mounting 70 40 210 133 0.1 22 0.1 Load application able, 6 wire, shielded, shield on enclosure Metal bellows able, 6 wire, shielded, shield on enclosure 34 13 Metal bellows 44 11.1 +0.1 9.9 31 27 15 38-0.1 20 60 40 25 58 21 23.4 42 20 5...200 kg 8.2 8.2 500 kg 10.5 11.1 able 5.4; 3 m long (standard version) 1010-3.0 en 1

Specifications Type Z6F1 Z6F3 Z6F3MI Z6F4 Z6F6 ccuracy class to OIML R 60 Number of scale intervals (n L ) 1 1000 Nominal (rated) load ( max ) kg 5; 10; 20; 50; 100; 200; 500 3 3000 10; 20; 50; 100; 200; 500 3/MI7.5 3000 50; 100; 200 4 4000 20; 50; 100; 200; 500 6 6000 50; 100; 200; % of n t 1 1 - - - Minimum scale division (v min ) % of max 0.0360 0.0090 0.0066 Return of minimum dead load signal ( R ) - - 0.5 max / 7500 - - Nominal (rated) sensitivity ( n ) mv/v 2 Sensitivity tolerance with load appl. in spec. direction % +(1;-0.1) 0.05 1) Temperature coefficient of sensitivity (T S ) 2) 0.0500 0.0080 0.0080 0.0070 0.0040 % of n /10 K Temperature coefficient of zero signal (TK 0 ) 0.0500 0.0125 0.0093 0.0093 0.0093 Relative reversibility error (d hy ) 2) 0.0500 0.0170 0.0066 0.0130 0.0080 Non linearity (d lin ) 2) 0.0500 0.0180 0.0180 0.0150 0.0110 Load creep (d R ) in 30 min. 0.0490 0.0166 0.0098 0.0125 0.0083 Input resistance (R L ) 350...480 Output resistance (R 0 ) 356 0.2 356 0.12 Reference voltage (U ref ) 5 V Nominal supply voltage range ( u ) 0.5...12 Insulation resistance (R is ) G 5 Nominal ambient temperature range ( T ) -10...+40 Operating temperature range ( tu ) o -30...+70 Storage temperature range ( tl ) -50...+85 Limit load ( L ) 150 % of max reaking load ( d ) 300 Nominal (rated) load kg 5 10 20 50 100 200 500 1000 Relative permissible oscillatory stress % of max 100 100 100 100 100 100 70 100 Nominal (rated) displacement (s nom ) approx. mm 0.24 0.3 0.29 0.27 0.31 0.39 0.6 0.55 Weight, (G) approx. kg 0.5 0.5 0.5 0.5 0.5 0.5 0.5 2.3 egree of protection (IP) as per N60529 IP 68 (tougher test conditions: 1 m water column; 100 h ) (I529) Material: Measuring body ellows able inlet gland able sheath Stainless steel 3) Stainless steel 3) Stainless steel / Viton PV 1) For load cell Z6F3/10kg: 0.1 %. 2) The values for linearity deviation, relative reversibility error and temperature effect on sensitivity are typical values. The sum of these values is within the cumulative error limits laid down by OIML R60. 3) s per N 10088-1 Options: x protection designs as per TX 95: II 2 G x ia II T4 or T6 (Zone 1) *) II 3 G x n II T6 (Zone 2) II 2 IP68 T80 (Zone 21) *) II 3 IP68 T80 (Zone 22 for non conductive dust) *) with type examination certificate able assignment (6 wire configuration) With this cable assignment, the output voltage at the measuring amplifier is positive when the transducer is loaded. M 2 (gray) (black) (white) (blue) (green) (red) (stranded wire) Sense lead (-) xcitation voltage (-) Measurement signal (+) xcitation voltage (+) Sense lead (+) Measurement signal (-) able shield connected to enclosure ground 1010-3.0 en

Installation aids, not included in scope of delivery (imensions (in mm; 1 mm = 0.03937 inches)) Note: ll installation aids are made of non rusting material. The rubber parts of the ZL are made of chloroprene rubber. Oscillating loading foot ZFP for nominal (rated) loads 5 kg...200 kg eight adjustable 69... 75 Steel 50 60 irection of load Rubber Z6/ZFP/200kg Knuckle eye ZGWR (maintenance free) for nominal (rated) loads 5 kg...1 t Screw and washer are included in the scope of delivery K SW J L M N F Z6/.../ZGWR G W Force feedback ZRR for nominal (rated) loads 5 kg... 200 kg F 1 G1 M 1 1 a Z6/200kg/ZRR 2 M 1 G 2 F2 b Nominal ZGWR F G J K L M SW W N (rated) load 5...200 kg Z6/200kg/ZGWR 16 8 7 24 36 48 9 12.5 16 5 M8 14 12 46 500 kg Z6/1t/ZGWR 20 10 7 28 43 57 10.5 15 19 6.5 M10 17 14 53 1 t Z6/1t/ZGWR 20 10 7 28 43 57 10.5 15 19 6.5 M10 17 14 55.5 Nominal ZRR 1 2 F 1 F 2 G 1 G 2 M 1 a b epth (rated) load 5...200 kg Z6/200kg/ZRR 16 30 30 65 85 46 77 M8 M8x30 80 1.1 123 15 Oscillating loading foot ZFP for nominal (rated) loads 5 kg...200 kg M8 Z6/.../ZKP 64...69 ø25 ø25 77...82 one, conical pan ZK for nominal (rated) loads 5 kg...1 t U Z6/.../ZK onical pan 90 one 60 16 SW19 SW13* * Tightening torque: 30 N m X ø80 Nominal (rated) load one, conical pan ZK U X 5...200 kg Z6/200kg/ZK 15 16 21 8.1-0.05 26 500 kg Z6/1t/ZK 18 24 32 11-0.05 34 1 t Z6/1t/ZK 18 24 32 11-0.05 36.5 1010-3.0 en 3 M

ase plate / Mounting set for nominal (rated) loads 5 kg (Z6/ZPU/200kg)... 500 kg (Z6/ZPU/500kg) Load application (Z6/...kg/ZPL; Z6/...kg/ZL ; Z6/...kg/ZK) View from below * 100 65 79 82 0.1 Gap 15 31 66 14 * Tightening torque M : 23 N m (200 kg) ; 45 N m (500 kg) Gap : In a load cell loaded with the nominal (rated) load, there should be a gap width 0.05 mm 155 200 22.5 Pendulum bearing ZPL for nominal (rated) loads 5 kg...1 t M T F U O Z6/200kg/ZPL Z6/500kg/ZPL Z17/2t/ZPL (for 500 kg, large and 1 t nominal (rated) load 2 dust protection rings included in ZPL scope of delivery Fastening screw included in ZPL scope of delivery Nominal (rated) load Pendulum bearing ZPL M O T F U F * R (% of the load) 5...200 kg Z6/200kg/ZPL 20-0.2 45 89 +0.6 0.8 M8 30 6.5 17 9 20 10 2.8 3.5 500 kg Z6/500kg/ZPL 20-0.2 45 89 +0.6 0.8 M8 30 6.5 17 9 20 10 2.8 3.5 1 t Z17/2t/ZPL 30-0.1 60 126.5 M10 46 8 22 14 30 10 2 7.5 * F R : Force feedback in N, with 1 mm lateral displacement ** s max : Maximum perm. lat. displacement with nominal (rated) loading s max ** (mm) M 4 1010-3.0 e n

Rubber metal bearing ZL for nominal (rated) loads 5 kg...200 kg For nominal (rated) loads 1 t L Z6/1t/ZL F F G Z6/200kg/ZL Screws offset by 35 K For nominal (rated) load 500 t M N L Z6/1t/ZL F P R orrect installation position of the rubber metal bearing Nominal (rated) load ZL F G K L M N P R F R * s max ** 5...200 kg Z6/200kg/ZL 75 M12 12 40 79 1.3 18.5 M8 SW17 19 - - - - - 163 3 500 kg Z6/1t/ZL 80 M10 10 39 +2.1 105 26 - SW27-20 120 100 9 60 400 4.5-2.2 1 t Z6/1t/ZL 80 M10 10 39 117 +2.1 2.2 * F R : Force feedback in N, with 1 mm lateral displacement ** s max : in mm, Maximum perm. lat. displacement with nominal (rated) loading 26 - SW27-20 120 100 9 60 400 4.5 1010-3.0 en 5 M

Modifications reserved. ll product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability and do not constitute any liability whatsoever. ottinger aldwin Messtechnik Gmb Im Tiefen See 45 64293 armstadt Germany Tel. +49 6151 803 0 Fax: +49 6151 803 9100 mail: info@hbm.com www.hbm.com 1010-3.0 en