Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Similar documents
Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

No. COA/BHL/2018/293 Dated: REQUEST FOR QUOTATIONS

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

(TECHNICAL SPECIFICATIONS & GTP FORMATS) 11KV METERING UNITS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

TRANSFORMER TECHNOLOGY GPT

Electrical Design Process

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Maharashtra State Electricity Distribution Company Limited

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Maharashtra State Electricity Distribution Co. Ltd.

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

General Electricity Company of Libya

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

HOW TO SAFE GUARD THE TRANSFORMER..???

Electrical Description

TECHNICAL SPECIFICATION FOR SELF PROTECTED SINGLE PHASE DISTRIBUTION TRANSFORMERS ( SPECIFICATION NO: DIST/01-N/2004 )

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Introduction. Centrado leading-edge transformer. Introduction

TECHNICAL SPECIFICATION OF 630 KVA, 11/ KV DRY TYPE OUTDOOR TRANSFORMERS.

Transformer Factory Testing

ISSN: [IDSTM-18] Impact Factor: 5.164

APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS

Subject: Computer Aided Electrical drawing (CAED) Subject Code: 10EE65

PROBLEMS on Transformers

86 chapter 2 Transformers

TECHNICAL SPECIFICATION OF 11 KV AND 22 KV THREE PHASE FOUR WIRE, THREE

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

SECTION VI TECHNICAL SCHEDULES

Design Comparison for Rectangular and Round Winding Distribution Transformer (1000kVA)

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Basic Principles and Operation of Transformer

Commissioning Manual Distribution Transformers - Three-phase Oil Filled

TECHNICAL SPECIFICATION OF 11 KV THREE PHASE FOUR WIRE, THREE CTs COMBINED METERING CTPT SET OF ACCURACY CLASS 0.5s

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

EARTHING TRANSFORMER

Reactor and inductor are names used interchangeably for this circuit device.

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

DISTRIBUTION TRANSFORMER 11 / kv

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Transformer Protection

DISTRIBUTION TRANSFORMER kv

148 Electric Machines

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Effects of Harmonic Distortion I

VI 3 - i TABLE OF CONTENTS

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION THE ELECTRICITY (PEDE) SPECIFICATIONS FOR

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Liquid-Filled Transformers

Hours / 100 Marks Seat No.

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

FERRORESONANT PROGRAM MANUAL V12.0

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

nical catalogue Tech

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

SECTION TRANSFORMERS

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

Regional Technical Seminar SHORT CIRCUIT FORCES

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

(

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

Practical Tricks with Transformers. Larry Weinstein K0NA

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Keywords: Overvoltage Suppression, Shunt Reactor, Loss Reduction, Regulate Voltage Level, Reactive Power Balance.

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

OIL-IMMERSED ARC-SUPPRESSION COILS

Ritz Instrument Transformers GmbH. Welcome

Mechanical Design. Brian Brinson Mechanical Design Manager.

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

Technical Specifications

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Transcription:

Group F : No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS Table : A No. Description 1. Make & Manufacturer 2. Place of Manufacturer 3. Voltage Ratio 4. Rating in KVA 5. Full load current HV : LV : 6. Core Material used and grade a) Flux density b) Over fluxing without saturation (Curve to be furnished by the manufacturer in support of his claim) 7. Maximum temperature rise of a) Windings by resistance method b) Oil by Thermometer 8. Magnetizing (No load) Current at a) Normal Voltage b) Maximum Voltage 9. Losses (should be in line with the Type Test report to be submitted along with the technical bid) in watts at 75 0 C a) No Load loss at rated voltage & frequency b) Full load loss at rated current and principal tap 10. Resistance of Windings at 20 Deg. C (With 5% tolerance) a) HV Winding (Ohms) b) LV Winding (ohms) 11. Total losses in watts at 75 0 C 12. Current density used for a) HV Winding b) LV Winding 13. Clearances (in mm) a) Core & LV b) LV & HV c) HV Phase to Phase d) End insulation clearance to Earth To be filled by the Bidder

e) Any Point of winding to tank f) Between HV Coils 14. % Impedance at 75 C 15. Radiation : a) Heat dissipation by tank walls exclusive top & bottom b) Heat dissipation by cooling tube c) Dia & thickness of cooling tube d) Whether calculation sheet for selecting cooling area to ensure that the transformer is capable of giving continuous rated output without exceeding temperature rise is enclosed. 16. Inter layer insulation provided in design for 1) Top & bottom layer 2) In between all layer 3) Details of end insulation 4) Whether wedges are provided at 50% turns of the HV coil 5) No of wedges provided 17. Insulation materials provided a) For Conductors (1) HV (2) LV b) For Core 18. Whether the offer conforms to the limits of impedance mentioned in the specification 19. Whether the offer conforms to the limits of temperature rise mentioned in the specification. 20. Whether the losses of the transformer offered are offered are within the limits specified 21. Whether the transformer offered is already type tested for the rating and test reports enclosed. 22. Whether the HV Bushings and LV Bushings offered are already type tested and test reports (Manufacture s test reports if it is a bought out item) enclosed.

TABLE - B No. Description 1. Voltage Ratio 2 Rating in KVA 3. Full load current 4.. Efficiency at 75 Deg. C. a) Unity P.F. & b) 0.8 P.F. 1) 125% load 2) 100% load 3) 75% load 4) 50% load 5) 25% load b) Max. efficiency 5. Regulation at a) Unity P.F. b) 0.8 P.F. at Deg. C 6. Flash Test HV 28KV / 50 Hz for 1 minute LV 3 KV / 50 Hz for 1 minute 7. Over potential Test Double Voltage & Double frequency for 1 minute 8. Impulse Test 9. Weight Content of a) Core lamination (min.) b) Windings (min.) c) Tank & Fittings d) Oil e) Oil Qty. (min.) To be filled by the Bidder

f) Total Weight 10. Oil Data 1. Qty. for first filling (min.) 2. Grade of oil used 3. Maker s name 4. BDV at the time of filling 11. Transformer : 1) Overall length x breadth x height 2) Tank length x breadth x height 3) Thickness of plates for a) Side Plate (min) b) Top & Bottom Plate (min.) 12. Size of the wire used 1) HV a) SWG / min b) Dia c) Area (Sq. mm) 2) LV a) Strip Size b) No. of Conductors in parallel c) Total area of cross section (sq.mm) 13. Is the name plate gives all particulars are required in Tender 14. Particulars of Bushings HV / LV 1) Maker s Name 2) Type IS 3347/IS-1180 3) Rating as per I.S. 4) Dry Flash over voltage KV at 50 C/s. 5) Wet Flash over voltage KV at 50 C/S 15. Details of tapping provided on HV side Not Applicable

TABLE - C No Description Unit 1 Core Grade 2 Core diameter mm 3 Gross Core area cm 4 Net Core area cm 5 Flux density Tesla 6 Wt. Core kg. 7 Loss per Kg. Of core at the specified Flux Density watts 8 Core window height mm 9 Centre to center distance of the core mm 10 No. of LV Turns mm 11 No. of HV Turns mm 12 Size of LV Conductor bare / covered mm 13 Size of HV Conductor bare / covered mm 14 No. of Parallels 15 Current density of LV winding amps/sq.mm 16 Current density of HV winding amps/sq.mm 17 Wt. of the LV winding for Transformers kg. 18 Wt. of the HV winding for1transformers kg. 19 No. of LV coils / phase 20 No. of HV coils / phase 21 Height of LV winding mm Height of HV Winding mm 22 ID / OD of LV winding mm 23 ID / OD of LV winding mm 24 Size of the duct in LV winding mm 25 Size of the duct in HV winding mm 26 Size of the duct between HV & LV mm 27 HV winding of LV clearance mm 28 LV winding to tank clearance mm 29 Calculated impedance mm 30 Calculated impedance % 31 HV to earth creepage distance mm 32 LV to earth creepage distance mm 33 LV to earth creepage distance mm 34 Winding Material 35 HV 36 LV To be filled by the Bidder

TABLE D SOURCE OF MATERIALS / PLACES OF MANUFACTURE, TESTING AND INSPECTION No. Item 1. Laminations 2. Aluminum / Copper 3. Core plates 4. Steel Castings / Sections 5. Tank 6. Insulating Cylinders 7. Bushing HV / LV 8. Oil 9. Insulated winding wire Source of Material Place of Manufacture Place of testing and inspection 10. a) Tap Changer. b) Pressure relief vent.

FORMAT FOR COST DATA ITEM DESCRIPTION (TO BE SUBMITTED ALONG WITH THE PRICE BID) UNIT Sr. No. PARTICULARS UNIT RATES (RS.) QTY. 1. CORE (M4 or better) KG 2. ALLUMINIUM / COPPER WITH KG DPC 3 INSULATION PAPER Meter 4. OIL LTRS 5. TANK Kg 6. CHANNELS KG 7 INSULATORS / BUHIUNGS NO AMT (Rs) 8 Radiators No 9 OTHERS LUMP SUM WASTAGE @% TOTAL TABLE E