GPON ONU SFF 2X10 GNUF-3412S-B2CDA

Similar documents
GNTP-4321S-C2CDA GPON SFP OLT Transceiver

GPON SFP OLT Transceiver GNTP-4321S-B2CDA

EPON OLT 1.25Gbps 1000Base-PX20 Tx1490/Rx1310nm DDMI SLEP-1143-P

Product Specification Sheet

GDETP-XX21S-2CD DWDM EPON OLT SFP Transceiver

SFP-7020-WB 1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

GP-8524-S5x(D) 1.25Gbps SFP Optical Transceiver, 550m Reach

GPB-5324L-L8CD 1.25Gbps SFP Bi-Directional Transceiver, 80km Reach 1550nm TX / 1310 nm RX

1.25Gbps SFP Bi-Directional Transceiver, 20km Reach 1310nm TX / 1550 nm RX CFORTH-SFP-35-20S

SFP BIDI 2.488Gbps 20KM 1550nm TX/1310nm RX

GLC LH SM. 1.25Gbps SFP Optical Transceiver, 20km Reach

GETX-5351S-X3CDA Asymmetricl 10G EPON OLT Transceiver

CWDM SFP 1.25G 40KM LC Duplex

GP-5524-L8x(D) 1.25Gbps SFP Optical Transceiver, 80km Reach

AOP-324-R20(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

HT201-24D083M Gbps 850nm SFP Optical Transceiver, 550m Reach

622Mbps SFP Optical Transceiver, 40km Reach FS-622M-A40

AC05-A13L6-02 (-DD) 155Mbps SFP Optical Transceiver, 2km Reach

3CP-485L1MN-SX 1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps SFP Optical Transceiver, 550m Reach

1.25Gbps CWDM SFP Optical Transceiver, 80km Reach SFP-7080-Cxx

XSB531-20xx Gbps SFP Bi-Directional Transceiver, 20 km Reach, 1550 nm TX/1310 nm RX. Features. Applications. Description

XSS311-20LY. 1.25Gbps SFP Optical Transceiver, 20km Reach. Features. Applications. Description

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

FSPC-xx12-40D. 1.25G SFP CWDM 1470nm~1610nm 40km Optical Transceiver

GP-3124-L2x(D) 1.25Gbps SFP Optical Transceiver, 20km Reach

1.25Gbps SFP Optical Transceiver, 550m Reach

1G SFP CWDM nm 80km Optical Transceivers

GPB-4324x-L4x(D) 1.25Gbps SFP Bi-Directional Transceiver, 40km Reach 1490nm TX / 1310 nm RX

622Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

GPB-5303x-L2x(D) 155Mbps SFP Bi-Directional Transceiver, 20km Reach 1550nm TX / 1310 nm RX

GP C(D) 155Mbps SFP Optical Transceiver, 2km Reach

2.67Gbps CWDM SFP Optical Transceiver, 40km Reach GPC-xx48-04X(D)

155Mbps SFP Optical Transceiver, 40km Reach GP L4x(D)

GPBC-xxxx24L-04CD 1.25Gbps SFP CWDM Bi-Di Single Fiber Transceiver, 40km Reach

EPON-OLT-20. OLT for IEEE 802.3ah-2004 PX Gbps Downstream and 1.25Gbps Upstream

Part Number Operating temperature DDMI. APGPU34AS3CXSC+ Commercial No. APGPU34AS3CDSC+ Commercial Yes. APGPU34AS3IXSC+ Industrial No

SFP M~2.67Gbps SFP Optical Transceiver, 300m Reach

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

MGS-MM MODULO GBIC SFP 500M 4.25GBPS LC MM 850NM VCSEL PIN TRANSCEIVERS

SFP-ZX-SM Gbps SFP Optical Transceiver, 80km Reach

SNS SFP-GDCWXD-XX* 1.25 Gbps 80 km CWDM SFP Transceiver

1.25Gbps CWDM SFP Optical Transceiver, 40km Reach EPC-xx24-04C(D)

Part Number Operating temperature DDMI. APGPL43ASLCDSC+ Commercial Yes. APGPL43ASLIDSC+ Industrail Yes

TS-GP2512-OLT-C+ GPON OLT Class C+ SFP Transceiver FEATURES

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

GLC-SX-MMD (1000BASE-SX SFP) Datasheet

GPON OLT SFP Class C+

SFP Optical Transceivers

1.25Gbps SFP Optical Transceiver, 20km Reach GP L2x(D)

10Gbps 1270/1330nm SFP+ BIDI TRx 40km

Features Gigabit Ethernet

APSB53123xxL20. Product Features. Applications. General. 1.25Gb/s BiDi SFP Transceiver

Part Number Operating temperature DDMI. APEPU34SYHCXSP2 Commercial No. APEPU34SYHCDSP2 Commercial Yes. APEPU34SYHIXSP2 Industrial No

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

XLT35-0D6C. 10GEPON OLT PR30 XFP Transceiver Rev. A0, May Features. Application. Standard

GLC-LH-SM-TX. Product Features. Applications. General. Cisco Compatible 1000BASE-LX/LH SFP TurboX

10Gbps 1330/1270nm SFP+ BIDI TRx 80km

LinkPower LPS SM BIDI 2612TC/2612TI & 2613RC/2613RI SC. RoHS Compliant 1.25G 1310/1550nm & 1550/1310nm 20km Transceivers

Part Number Operating temperature DDMI. APSCxx123CXL80 Commercial No. APSCxx123CDL80 Commercial Yes. APSCxx123IXL80 Industrial No

Features: Applications: Description:

1.25Gb/s SFP Transceiver P/N: MO-C-S31123CDL20. Product Features. Applications. General. Regulatory Compliance. Up to 1.

GBP-XXXX192-L2C 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

GE-PON OLT Transceiver 1.25Gbps Upstream/1.25Gbps Downstream

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

SFP-10G-LR-TX. Product Features. Applications. Product Selection. Cisco Compatible 10GBase-LR SFP TurboX

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

JD061A-C. 1.25Gbps SFP Transceiver

SFP CWDM 1G 120km LC datasheet A-GEAR World Wide Manufacturing Product Specification

Part Number Wavelength Operating Case temperature. APCSP23B33CDL10 Tx-1270 / Rx-1330 Commercial. APCSP32B33CDL10 Tx-1330 / Rx-1270 Commercial

Part Number Operating temperature DDMI. APS31123CXL2 Commercial No. APS31123CDL2 Commercial Yes. APS31123IXL2 Industrial No

Gigabit Ethernet LC Bi-directional SFP Transceiver (80km) RBT12SZX

SO-CSFP-100Base-BX20D-34-O2 -I

SFP-1020-WA/B 10Gbps SFP+ Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

Product Specification. SFP OLT 1G 20km SC. 1.25Gbps Upstream/1.25Gbps Downstream GE-PON OLT Transceiver. SFP OLT 1G 20km SC

10Gb/s CWDM SFP+ 20Km RT-P10LCM-C00-xx. Optical Transceiver

1.25G 1310/1490nm Compact SFP Transceiver

SFP-1000BASE-LX-LEG. 1.25Gbps SFP Transceiver

GLC-LH-SM-LEG-5PK. 1.25Gbps SFP Transceiver

XBR C. 8Gbs SFP+ Transceiver

LinkPower LPS LC MM 2630C/2630I. RoHS Compliant 1.25Gbps 850nm 550M Optical Transceiver

Gigabit Ethernet LC Bi-directional SFP Transceiver (40km) RBT12SEX

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

Product Features. Applications. Standards Compliance. 10G SFP+ LR Transceiver. General Description

SO-SFP-1000BASE-ZXD-I

10Gb/s CWDM SFP+ 80km Transceiver

FTS-GPON-OLT-C+ GPON OLT SFP transceiver, 1490/1310nm, single-mode, RSSI, 60km

Hot Pluggable, Duplex LC, 1310nm DFB-LD, Single Mode, DDM Distance: 10KM. monitor. mode fiber

Specifications. (Tc=-5 to 70 and Vcc= 3.14 to 3.46V) Nominal Wavelength λ nm Side Mode Suppression Ratio. Receiver

10Gb/s 10Km CDR SFP+ 1310nm Transceivers

1.25Gbps SFP Optical Transceiver, 80KM Reach

SFP-10G-SR-LEG. 10Gbs SFP+ Transceiver

4.25Gbps SFP Transceiver

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

SFP-10GCWZR-xx-TP 10Gb/s CWDM SFP+ 80km Transceiver

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

Product Specification SFP WDM 100M 20km SC Transceiver

DATASHEET 4.3. SFP+, 10GBase-LR, 1310nm, SM, DDM, 70km, RX sensitivity -22 dbm, Ind.temp.

RoHS compliant TX-1310/RX-1550 nm Single-mode Bi-directional SFP LC Simplex Connector DDM. Features

Transcription:

Features GPON ONU SFF 2X10 GNUF-3412S-B2CDA Single fiber Bi-Directional transceiver with SC Receptacle Connector 1310nm burst-mode 1.25Gbps transmitter with DFB LD laser 1490nm continuous-mode 2.5Gbps receiver with APD-TIA Burst mode: low active Complies with ITU-T G.984.2 Class B+ Digital diagnostic interface compliant with SFF-8472 Rev 9.5, Digital Diagnostic Monitoring (DDM) with external calibration 3.3V Single power supply Complies with RoHS directive (2002/95/EC) Operating case temperature:standard : 0 to +70 C Applications GPON ONU Class B+ Burst mode application. FTTx WDM Broadband Access Description The GNUF-3412S-B2CDA Bi-Directional Transceiver is the high performance module for single fiber communications by using 1310nm 1.25Gbps burst mode transmitter and 1490nm 2.5Gbps continuous receiver. It is Optical Network Unit (ONU) for ITU-T G.984.2 Class B+. The optical transceiver is compliant with Multi-Source Agreement (MSA) Small Form Factor (SFF) 2x10 footprint. The transmitter section uses a 1310nm DFB laser diode with automatic power control (APC) function and temperature compensation circuitry to ensure stable extinction ratio over all operating temperature range, and full IEC825 and CDRH class 1 eye safety. The receiver has a hermetically packaged PIN-TIA (trans-impedance amplifier) pre-amplifier and a limiting amplifier with CML compatible differential outputs. Address: 5F, Main Building SheKou Technology Building, Page 1 of 9

Absolute Maximum Ratings Table 1 - Absolute Maximum Ratings Parameter Symbol Min Max Unit Notes Storage Temperature Tst -40 +85 C - Operating Case Temperature Tc 0 70 C - Operating Humidity RH 5 90 % Non-condensing Input Voltage - GND Vcc V - Power Supply Voltage Vcc-Vee 0 3.6 V - Recommended Operating Conditions Table 2 - Recommended Operating Conditions Parameter Symbol Min Typical Max Unit Operating Case Temperature Standard Tc 0-70 C Power Supply Voltage Vcc 3.13 3.3 3.47 V Power Supply Current Icc - - 300 ma Optical and Electrical Characteristics Table 3 - Optical and Electrical Characteristics Parameter Symbol Min Typical Max Unit Notes Transmitter Tx Data Rate R T - 1.25 - Gb/S - Centre Wavelength λc 1276 1310 1356 nm - Spectral Width λ - - 2.8 nm - Total Jitter TJ - - 0.35 UI - Side Mode Suppression Ratio SMSR 30 Average Output Power Pout 0.5-5 dbm 1 Average Launch Power-OFF Transmitter Poff -45 dbm Extinction Ratio ER 10 - - db - Address: 5F, Main Building SheKou Technology Building, Page 2 of 9

Burst Enable Delay Ton - - 16 ns Fig.1 Burst Disable Delay Toff - - 16 ns Fig.1 Relative Intensity Noise Transmitter & dispersion penalty Optical Eye Diagram Optical Rise/Fall Time (20%~80%) RIN 15 _OM A -115 db/ Hz TDP 1.8 db Compliant with of ITU-T G.984.2 tr/tf 260 ps Data Input Swing Differential V IN 200 1600 mv 2 Input Differential Impedance Z IN 90 100 110 Ω Burst TX Fault Disable 2.0 Vcc V Enable 0 0.8 V Fault 2.0 Vcc V Normal 0 0.8 V Receiver Rx Data Rate R R - 2.5 - Gb/s 3 Centre Wavelength λc 1480 1500 nm Receiver Sensitivity(BOL) Sen -28 dbm 3 Receiver Overload Sat -8 dbm 3 Receiver Reflectance -12 db Signal Detect De-Assert SDD -44 dbm Signal Detect Assert SDA -28 dbm Signal Detect Hysteresis SDH 0.5 6 db Output Differential Impedance Z IN 90 100 110 Ω Data Output Swing Differential SD Output Voltage V out 400 1400 mv High 2.0 Vcc V Low 0 0.8 V Address: 5F, Main Building SheKou Technology Building, Page 3 of 9

Notes: 1. The optical power is launched into SMF. 2. PECL input, internally DC-coupled and terminated. 3. Measured with a PRBS 2 23-1 test pattern @2500Mbps, BER 1 10-12. Diagnostics Table 4 Diagnostics Specification Parameter Range Unit Accuracy Calibration Temperature 0 to +70 C ±3 C Internal Voltage 3.0 to 3.6 V ±3% Internal Bias Current 0 to 100 ma ±10% Internal TX Power 0.5 to 5 dbm ±3dB Internal RX Power -28 to -8 dbm ±3dB Internal Transmitter Burst Mode Timing Characteristics Definition of Burst Enable Delay (T on ) and Burst Disable Delay (T off ) OPTICAL OUTPUT 90% 10% BURST 50% 50% Ton Toff Fig.1 Address: 5F, Main Building SheKou Technology Building, Page 4 of 9

Digital Diagnostic Memory Map The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA). The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring. The digital diagnostic memory map specific data field defines as following. Address: 5F, Main Building SheKou Technology Building, Page 5 of 9

Pin Definitions Pin Diagram Pin Descriptions Pin Signal Name Description Notes 1 NC Not Connect 2 V EER Receiver ground 3 V EER Receiver ground 4 NC Not Connect 5 NC Not Connect 6 V EER Receiver ground 7 V CCR Receiver Power Supply 8 SD Signal Detect Output Note 1 9 RD- Inv. Received Data CML Output, internal AC Coupling Note 2 10 RD+ Received Data CML Output, internal AC Coupling Note 2 11 V CCT Transmitter Power Supply 12 V EET Transmitter Ground 13 BURST Transmitter Burst Control Note 3 14 TD+ Transmit Data LVPECL Input, Internal AC Coupling Note 4 15 TD- Inv. Transmit Data LVPECL Input, Internal AC Coupling Note 4 16 V EET Transmitter Ground 17 SCL Serial Clock Signal Note 5 18 SDA Serial Data Signal Note 5 19 TX_F TX Fault Alarm,LVTTL Output 20 TX_SD TX Signal Detected Address: 5F, Main Building SheKou Technology Building, Page 6 of 9

Notes: Plug Seq.: Pin engagement sequence during hot plugging. 1) Logic 0 indicates loss of signal; Logic 1 indicates normal operation. In the low state, the output will be pulled to less than 0.8V. 2) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES. 3) BURST is a TTL input. When it is low, LD is on; when it is high, LD is off. 4) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module 5) SCL,SDA should be pulled up with a 4.7k~10kΩ resistor on the host board. The pull-up voltage shall be VccT or VccR. SCL is the clock line of two wire serial interface for serial ID SDA is the data line of two wire serial interface for serial ID Address: 5F, Main Building SheKou Technology Building, Page 7 of 9

Recommend Application Circuit Address: 5F, Main Building SheKou Technology Building, Page 8 of 9

Mechanical Dimensions Ordering information Part Number GNUF-3412S-B2CDA Product Description Tx1310nm, Rx1490nm, 1.25Gbps/2.5Gbps, GPON ONU Class B+, Burst low, 0ºC ~ +70ºC with Digital Diagnostic Monitoring E-mail: sales@gigalight.com.cn Web : Address: 5F, Main Building SheKou Technology Building, Page 9 of 9