Data Compression and Analysis Methods for High- Throughput Radiation Detector Systems

Similar documents
INDEX. Firmware for DPP (Digital Pulse Processing) DPP-PSD Digital Pulse Processing for Pulse Shape Discrimination

Electronic Instrumentation for Radiation Detection Systems

Traditional analog QDC chain and Digital Pulse Processing [1]

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

Digital trigger system for the RED-100 detector based on the unit in VME standard

Contents. Why waveform? Waveform digitizer : Domino Ring Sampler CEX Beam test autumn 04. Summary

Beam Condition Monitors and a Luminometer Based on Diamond Sensors

Data Acquisition System for the Angra Project

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

A NOVEL FPGA-BASED DIGITAL APPROACH TO NEUTRON/ -RAY PULSE ACQUISITION AND DISCRIMINATION IN SCINTILLATORS

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

CAEN Tools for Discovery

Development of a 20 GS/s Sampling Chip in 130nm CMOS Technology

A Fast Waveform-Digitizing ASICbased DAQ for a Position & Time Sensing Large-Area Photo-Detector System

ToF-AMS DAQ. Joel Kimmel Univ. of Colorado at Boulder & Aerodyne Research, Inc AMS Users Meeting 2007

INL and the Consortium for Verification Technology

PROGRESS in TOF PET timing resolution continues to

Performance of High Pixel Density Multi-anode Microchannel Plate Photomultiplier tubes

Electronic Readout System for Belle II Imaging Time of Propagation Detector

A tracking detector to study O(1 GeV) ν μ CC interactions

Diamond sensors as beam conditions monitors in CMS and LHC

Backgrounds in DMTPC. Thomas Caldwell. Massachusetts Institute of Technology DMTPC Collaboration

Development of a 256-channel Time-of-flight Electronics System For Neutron Beam Profiling

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

Digitization of PMT signals with FADCs: comparison of simulation and measurement

Development of a Multi-Channel Integrated Circuit for Use in Nuclear Physics Experiments Where Particle Identification is Important

Arrays of digital Silicon Photomultipliers Intrinsic performance and Application to Scintillator Readout

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Overview 256 channel Silicon Photomultiplier large area using matrix readout system The SensL Matrix detector () is the largest area, highest channel

LaBr 3 :Ce, the latest crystal for nuclear medicine

Development of LYSO detector modules for a charge-particle EDM polarimeter

The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

arxiv: v2 [astro-ph.im] 2 Jul 2012

Transmission-Line Readout with Good Time and Space Resolution for Large-Area MCP-PMTs

COMPENDIUM OF FRONT-END ELECTRONICS

Digital coincidence acquisition applied to portable β liquid scintillation counting device

Design and Test of a 65nm CMOS Front-End with Zero Dead Time for Next Generation Pixel Detectors

Nyquist filter FIFO. Amplifier. Impedance matching. 40 MHz sampling ADC. DACs for gain and offset FPGA. clock distribution (not yet implemented)

The software and hardware for the ground testing of ALFA- ELECTRON space spectrometer

Analogue to Digital Conversion

INL and the Consortium for Verification Technology

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Performance of 8-stage Multianode Photomultipliers

Virtual Laboratory of Nuclear Fission Virtual practicum in the framework of the project Virtual Laboratory of Nuclear Fission

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

Keyser, Ronald M., Twomey, Timothy R., and Bingham, Russell D. ORTEC, 801 South Illinois Avenue, Oak Ridge, TN 37831s

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

Transmission-Line Readout with Good Time and Space Resolution for Large-Area MCP-PMTs

CATIROC a multichannel front-end ASIC to read out the SPMT system of the JUNO experiment

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Highlights of Poster Session I: SiPMs

A 4-Channel Fast Waveform Sampling ASIC in 130 nm CMOS

DAQ & Electronics for the CW Beam at Jefferson Lab

Production of HPDs for the LHCb RICH Detectors

PARISROC, a Photomultiplier Array Integrated Read Out Chip

TOP R&D status. Noriaki Sato (Nagoya Univ.) Super B-Factory Workshop in Hawaii. Status MCP-PMT R&D Summary

Trigger and Data Acquisition (DAQ)

Multi-channel front-end board for SiPM readout

Development and Application of 500MSPS Digitizer for High Resolution Ultrasonic Measurements

The domino sampling chip: a 1.2 GHz waveform sampling CMOS chip

A Readout ASIC for CZT Detectors

PoS(TWEPP-17)025. ASICs and Readout System for a multi Mpixel single photon UV imaging detector capable of space applications

Mass Spectrometry and the Modern Digitizer

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

P ILC A. Calcaterra (Resp.), L. Daniello (Tecn.), R. de Sangro, G. Finocchiaro, P. Patteri, M. Piccolo, M. Rama

CLARO A fast Front-End ASIC for Photomultipliers

RP220 Trigger update & issues after the new baseline

Highly Segmented Detector Arrays for. Studying Resonant Decay of Unstable Nuclei. Outline

A 4 Channel Waveform Sampling ASIC in 130 nm CMOS

Development of a sampling ASIC for fast detector signals

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Status of SVT front-end electronics M. Citterio on behalf of INFN and University of Milan

Study of the ALICE Time of Flight Readout System - AFRO

Activities in Electronics Lab Associates are: Mrs. Arti Gupta, K.S.Golda, S.Muralithar & Dr.R.K.Bhowmik

Positron Emission Tomography

MuLan Experiment Progress Report

Recent developments for the Garching Compton Camera Prototype

Progress towards a 256 channel multianode microchannel plate photomultiplier system with picosecond timing

MASE: Multiplexed Analog Shaped Electronics

Analogue to Digital Conversion

Analog Peak Detector and Derandomizer

Design of the Front-End Readout Electronics for ATLAS Tile Calorimeter at the slhc

The High-Voltage Monolithic Active Pixel Sensor for the Mu3e Experiment

FPGA BASED DATA AQUISITION SYSTEMS FOR PHYSICS EXPERIMENTS

DarkSide-50. Alessandro Razeto LNGS 26/3/14

PMT Calibration in the XENON 1T Demonstrator. Abstract

Software Module MDPP-16-QDC V0003

arxiv: v1 [physics.ins-det] 5 Sep 2011

The Architecture of the BTeV Pixel Readout Chip

In the name of God, the most merciful Electromagnetic Radiation Measurement

Implementation of High Precision Time to Digital Converters in FPGA Devices

Effects of Dark Counts on Digital Silicon Photomultipliers Performance

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

A CMOS INTEGRATED CIRCUIT FOR PULSE-SHAPE DISCRIMINATION*

A high energy gamma camera using a multiple hole collimator

Simulation of Algorithms for Pulse Timing in FPGAs

Multi-Channel Time Digitizing Systems

KLauS4: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

Transcription:

1 Data Compression and Analysis Methods for High- Throughput Radiation Detector Systems John Mattingly Associate Professor, Nuclear Engineering North Carolina State University

2 Introduction The capabilities of analog-to-digital (A/D) conversion instruments are rapidly advancing High resolution (10-bit [1:1024] to 14-bit [1:16,384]) High sampling rates (100 MS/s to 5 GS/s) High channel density (8 channels to 64 channels) Low dead time (nearly zero to 10s of µsec) Low cost ($100 to $10,000) Our ability to acquire radiation detector signals is rapidly surpassing our ability to analyze them in realtime

3 High-output vs. high-throughput There are many multi-modal radiation detector systems currently under development: Gamma and neutron time-of-arrival, energy, and multiplicity systems Fast neutron imagers Spectroscopic gamma imagers Some of these systems can output 100s of gigabytes of digitally sampled radiation detector signals from a single measurement We need to develop methods to compress and analyze the signals they acquire in near real-time

4 Digital data acquisition Waveform digitizers sample the detector s analog output at regular intervals to create a digital record of the signal amplitude vs. time In some applications, only a few specific parameters need to be extracted from each pulse Time-of-arrival Energy deposited Particle type However, in other applications, the entire digitized pulse is needed In still other applications, only specific patterns of pulses are needed

5 Waveform digitization CAEN VX1730: Flash ADC VME module Moderate sampling rate (500 MS/s) High resolution (14 bits) Channel density: 16 channels/module High per-unit cost (~$20,000) PSI DRS-4: Switched capacitor array Moderate resolution (11-12 bits) High sampling rate (700 MS/s to 5 GS/s) Channel density: 8 channels/chip Low per-unit cost (< $100 per chip in large quantities) Requires several additional components for digitization (clock, ADC, FPGA); PSI offers an evaluation board Large dead-time for readout CAEN VX1730 PSI DRS-4

6 Data analysis and compression A single waveform record is typically on the order of 1 to 2 kilobytes Detector systems that employ a large number of channels can rapidly acquire gigabytes to terabytes of data Analysis to extract arrival time, energy, and particle type can reduce the record to a few bytes In applications where the digitized pulse is required, there are methods to compress the record Retain only the portion of the record above the baseline Decimate the trace into a smaller number of samples representing the integral over specific portions of the pulse In some applications, only specific patterns of pulses need to be recorded In all 3 cases, there are tradeoffs between throughput and fidelity of the measurement and what constitutes fidelity is highly application-specific

7 Strategy for research We plan to conduct research in data analysis and compression in 3 related areas Mine existing data acquired by high output detector systems to extract useful signatures of SNM corresponding to specific pulse patterns Apply optimization to pulse compression to study tradeoffs between throughput and fidelity Develop data acquisition logic to reduce the data velocity at the frontend of different detector systems We ve identified 3 detector systems that can serve as test-beds for the research LLNL liquid scintillator array ORNL/SNL fast neutron coded aperture camera SNL fast neutron single volume scatter camera

8 LLNL liquid scintillator array Original configuration Latest configuration 72 10 cm dia. x 10 cm thick EJ-301 scintillator cells Courtesy L. Nakae (LLNL)

9 Fission chain-reaction dynamics Fission Fission Background Courtesy L. Nakae (LLNL)

10 Fission chain-reaction dynamics Courtesy L. Nakae (LLNL) 1 ton of lead Background Spallation neutrons 1 ton of lead + HEU metal (multiplication 2.5 to 3) Induced fission

11 ORNL/SNL fast neutron coded-aperture imager CH 2 aperture Organic scintillators Plutonium plates at INL Early prototype M. Blackston (ORNL), et al., INMM 2012 P. Marleau (SNL), et al., INMM 2011

12 Filtering fast neutron images for fission chain-reactions Neutron time since preceding gamma vs. energy Fission chain-reaction neutrons appear in this region Image of Cf-252 source All events Late-arriving events J. Linkous (NCSU)

13 SNL multi-volume scatter camera Original 11-cell version P. Marleau (SNL), et al., IEEE NSS 2007 SNL patent US 7741613 B1 The current version uses 32 organic scintillators

14 SNL single-volume scatter camera (SVSC) Multi-volume camera Single-volume camera not to scale nominally 20 20 20 cm 3 volume

15 Scintillation position reconstruction Photonis pixelated MCP photomultiplier Scintillation event at origin (simulation) 5 cm 5 cm 64 (8 8) 6 mm 6mm pixels K. Weinfurther (NCSU)

16 Double-scintillation event reconstruction using direct likelihood maximization Courtesy E. Woods (SNL)

17 Optically-segmented SVSC Event reconstruction that uses the entire data cube containing the response of ~2048 pixels recorded at ~1024 intervals of 200 ps is not practical (that s 4 megabytes acquired in 200 ns for one event) SVSC s current long-term strategy for analysis is to implement data acquisition logic that retains only useful samples (i.e., only retain samples where photons were detected) NCSU and SNL are investigating a second alternative design that optically segments the scintillator to reduce the number of channels

18 Data acquisition logic Using an optically segmented design, it may be possible to reduce the number of channels that need to be digitized to 20 20 channels = (brightest cell + 4 nearest neighbors) (2 scintillation centers) (2 photodetectors) However, it will require a network of switches to route the correct channels to the digitizers It will also require an array of lowcost discriminators to trigger the switches and delay components to time the digitization correctly Courtesy J. Steele (SNL)

19 Summary There are numerous alternative approaches to data analysis and compression for high data velocity detector systems We plan to research 3 main areas: Identify specific pulse patterns that are signatures of SNM by mining existing data Study tradeoffs between throughput and fidelity by applying optimization to pulse compression Reduce the data velocity at the front-end of different detector systems using data acquisition logic There are 3 existing detector systems that are good candidates for study: LLNL liquid scintillator array ORNL/SNL fast neutron coded aperture camera SNL fast neutron single volume scatter camera

20 SUPPLEMENTAL SLIDES

Onboard data compression Struck Innovative Systeme (SIS) : Moderate sampling rates Moderate to high resolution Moderate channel density Some SIS digitizers provide onboard compression of digitized signal into userdefined gate integrals http://www.struck.de/sis3316.html 21

22 Particle type discrimination using gate integrals Compressing the digitized waveform into a small number of gate integrals substantially increases throughput in high event rate applications However, it can also degrade particle type discrimination Gamma misclassification (i.e., as a neutron) can occur when multiple pulses occur in the same record