TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR /5-15

Similar documents
TECHNICAL DESCRIPTION Issue 1.00 FOR 4-QUADRANT SERVO AMPLIFIER AS 3HE - EUROCARD FOR. DC-MOTORS UP TO 3,4 kw TYPE. MTRS 170-xx

SCA-SS (70V, 10A)

TECHNICAL INFORMATION Issue 1.01 FOR TRANSISTOR-FOUR-QUADRANT- SERVO-AMPLIFIER TYPE MTR 2800 MTR 5000

Servo Amplifier PMA 90 / 180

Manual SCA-SS V /02 page 1

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Logosol AC/DC Servo Amplifier LS-57P

INSTALLATION MANUAL NE2110, NE2120 D.C. SERVO CONTROLLERS

DynaDrive INFORMATION MANUAL SDFP(S)

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

SCS Automation and Control Ltd

Logosol AC/DC Servo Amplifier LS-58P Doc # / Rev D, 07/17/2008

DA4303. User Manual DA Q Linear Servo 03 A

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

maxon motor maxon motor control 1-Q-EC Amplifier DECS 50/5 Order number

Operator Manual. 2-Phase Stepping Motor Drive ECMD 285, 2810, 2135, 21310

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

About this Manual: Chapter 1 provides a summary of the Servo System and all gains used for the Servo System loops.

BLOCK DIAGRAM OF THE UC3625

SCA-SS User Manual SCA-SS Q PWM Servo 10 A

ESR. The Dynamic Solution. Applications. Products, Consultation, and Service. ESR Pollmeier GmbH

HPVFP High Performance Full Function Vector Frequency Inverter

SCA-SS User Manual SCA-SS Q PWM Servo 06 A

MODEL 503 DC BRUSHLESS SERVO AMPLIFIER

Protected against over temperature and over current MOSFet-technology, efficiency 95% Continuous current up to 09 / 18 A (model dependent)

UNIVERSITY OF JORDAN Mechatronics Engineering Department Measurements & Control Lab Experiment no.1 DC Servo Motor

Phase Control Circuit Tacho Applications. Automatic retriggering. Phase control unit = f (V 12 ) Soft start 11(11) 12(12) 8(8) 7(7)

Protected against over temperature and over current Continuous current up to 3 A

AN003. Basic Terms Used for DC Power Supplies. Elaborated by: Marco Geri (R&D Manager - NEXTYS SA.)

PWM SERVO CONTROLLERS SERIES MRM

COOPERATIVE PATENT CLASSIFICATION

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

Data Sheet. Stepper Motor Drive Boards. Features

DLVP A OPERATOR S MANUAL

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

Application Note. I C s f o r M o t o r C o n t r o l. Evaluation board for the TDA5143/TDA5144. Report No: EIE/AN R. Galema

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

SRVODRV REV7 INSTALLATION NOTES

PERMA Series Revision 2 Amplifiers

HIGH PERFORMANCE BRUSHLESS DC MOTOR DRIVER (800) 546-APEX (800) TOP DRIVE 1 1/2 BRIDGE 11 BOTTOM DRIVE 1

Special Internal Circuits

Laboratory Tutorial#1

Analog Servo Drive 25A20DD

EC 45 flat with integrated electronics Document ID: en Operating Manual

Power Pulse Modulator A High Performance Versatile Square Pulse Generator

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

Introduction to MS150

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

No Gain Tuning. Hunting. Closed Loop System

L E C T U R E R, E L E C T R I C A L A N D M I C R O E L E C T R O N I C E N G I N E E R I N G

DUAL STEPPER MOTOR DRIVER

DSAE - AAA - B - C - DD - E AAA

Upgrading from Stepper to Servo

Analog Servo Drive 20A20

VERSATILE AUDIO AGC CIRCUIT Dave Kenward G8AJN

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

Specify Gain and Phase Margins on All Your Loops

BMC 6C & 7D HARDWARE INSTALLATION MANUAL. MCG Inc. BMC 6C & 7D Hardware Installation Manual ZN2UDB6799-4

Operating Instructions

Conventional Paper-II-2011 Part-1A

Linear Power Amplifier Module

( DIGITAL SERVO AMPLIFIER FOR BRUSHLESS MOTOR ) INSTRUCTION AND USER MANUAL

INSTRUCTION MANUAL SERIES

LSI/CSI LS7560N LS7561N BRUSHLESS DC MOTOR CONTROLLER

SPECIFICATION, CONTROLS AND ACCESSORIES

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2844 PID CONTROLLER WITH FEED FORWARD COMPENSATION

EA4709 / EA4718. User Manual EA4709 / EA Q PWM Servo 09 / 18 A

BC145 SIGNAL ISOLATOR BOARD

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

TA7259P, TA7259F/FG TA7259P/F/FG 3-PHASE BRUSHLESS DC MOTOR DRIVER IC FEATURES TOSHIBA BIPOLAR LINEAR INTEGRATED CIRCUIT SILICON MONOLITHIC

XES-M50 Operating Instructions

BLOCK DIAGRAM OF THE UC3625

7I54 MANUAL Six channel 40V 3A Servo motor drive

Datasheet of the Easy Servo Drive ES-D VDC, 8.0A Peak, Closed-loop, No Tuning

High Efficiency Power Amplifier Module

Industrial motor controller for brushed DC motors 24 VDC

Troubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.

Where: (J LM ) is the load inertia referred to the motor shaft. 8.0 CONSIDERATIONS FOR THE CONTROL OF DC MICROMOTORS. 8.

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

6.9 Jump frequency - Avoiding frequency resonance

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

Installation Tech Note Dallas, Texas

Type Ordering Code Package TDA Q67000-A5066 P-DIP-8-1

DeviceCraft Revision #1 11/29/2010

profile Using intelligent servo drives to filter mechanical resonance and improve machine accuracy in printing and converting machinery

10 AMP, 75V, 3 PHASE MOSFET BRUSHLESS MOTOR CONTROLLER

POWER SUPPLIES SPS1000 SERIES CIRCUIT DESCRIPTION AND OPERATING MANUAL

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

DC SERVO MOTOR CONTROL SYSTEM

OPERATION & SERVICE MANUAL

Note 1: A 3A version to the LT1005 is also available. See LT1035 LT V, 35mA AUXILIARY REGULATOR

Type of loads Active load torque: - Passive load torque :-

HBS Series Hybrid Servos

Power Supply Unit (550W)

Analog Servo Drive 30A8

Transcription:

TECHNICAL INFORMATION edition 1.02 FOR TRANSISTOR-FOUR-QUADRANT SERVO-AMPLIFIER SERIES MTR 24...60/5-15 MATTKE AG Leinenweberstraße 12 D-79108 Freiburg Germany Telefon: +49 (0)761-15 23 4-0 Telefax: +49 (0)761-15 23 4-56 E-Mail: info@mattke.de http://www.mattke.de

MTR 24...60/5-15 2 21.02.2006 Dear customer, We always try to guarantee for an optimum of security measures and to inform ourselves about the latest developments in technical research. However, it is necessary that we pass on the following further information to you as the user of our components: The appliances are supply parts meant for processing by industry, trade or other factories specialised in electronics. Safety precaution!! Attention - do not touch! The appliances have unprotected live parts. The voltage may be highly dangerous. We also have to inform you that, for your own security, only an expert should work on the appliances. In order to comply with the safety precautions, open connections must be protected against contact with cases, coverings or anything similar. Even after the appliance had been disconnected, there may still be a dangerous voltage (discharges of the capacitors). Due to an error in handling or unfavourable conditions, the electrolytic capacitors may explode. If you have to work on the open appliance, do protect your body (hands!) and your face! Make sure that there is enough ventilation because of the fire risk in case of overheating.

MTR 24...60/5-15 3 21.02.2006 CONTENTS page 1. Important instructions... 4 2. General information... 4 3. Technical data... 5 4. Control principle... 5 5. Inputs... 6 5.1 Speed set value inputs... 6 5.2 Current limitation input... 6 5.3 Disable input... 6 5.4 Tacho input... 6 5.5 Integral disable... 6 5.6 Limit switch positive stop... 6 5.7 Limit switch negative stop... 7 6. Supply... 7 6.1 Auxiliary voltage inputs... 7 6.2 Supply of the intermediary circuit... 7 6.3 Battery supply... 7 7. Outputs... 8 7.1 I 2 t output... 8 7.2 Output "ready for operation"... 8 7.3 Actual current value output... 8 7.4 Motor output... 8 8. Adjustment possibilities... 9 9. Connections... 10 10. Wiring... 10 11. Starting... 11 11.1 Presetting... 11 11.2 Setting of pulsed current and continous current limit... 11 11.3 Speed adjustment... 11 11.4 Offset adjustment... 12 11.5 Ballast circuit... 12 11.6 Dimensions... 12 11.7 Wiring diagram... 13 11.8 Wiring diagram... 13 11.9 Plan of components... 14 12. Optimization of the control behaviour... 15 12.1 Amplification of the alternating voltage... 15 12.2 Amplification of the direct voltage... 15 12.3 Integrated part of the speed controller... 15 13. Service diagnosis... 16 14. Wiring diagram as positioning amplifier MTNR 24...60/5-15... 17

MTR 24...60/5-15 4 21.02.2006 1. IMPORTANT INSTRUCTIONS - the amplifier should only be connected and started by experienced technicians - the amplifier should only be installed or removed with the supply voltage switched off - after switching off the amplifier, parts of the board can still be alive for about 3 minutes - make sure that the intermediary circuit voltage measured at the plug-in unit between pin 30ace and 24ace cannot exceed 75V even when the motor is not running - please be careful when calculating the transformer secondary voltage and allow for voltage differences between no load and full load as well as mains fluctuations 2. GENERAL INFORMATION The transistor servo amplifier MTR 24...60/5-15 is a pulse width modulated unit which can easily be mounted into a 19" / 3U rack. Its main application is driving servo motors in the 4-quadrant mode (4 quadrant means that the amplifier can drive and brake the motor in either direction). At the amplifier's output both polarities are available without switching over. During acceleration the 3 fold current can be output for a maximum of 3 seconds, whereby the motor can reach the 3 fold of its continuous torque rating as pulse torque. For operation you only need the power supply, the motor and perhaps an external ballast circuit and a standard set value. Advantages: - on account of a special principle of modulation almost no phase noises from the amplifier or the motor - high efficiency through optimal drive of the final stage - a very small minimum load inductance and the low internal resistance of the amplifier result in a high dynamics - I 2 t current limitation - protection for over voltage, over current and over temperature - open collector output for brake relay at malfunction - three modes of operation (tacho/ixr/current control) can be chosen by means of a jumper - for all the possibilities of adjustment there are multiple trimming potentiometers The amplifier is designed for a constant current of 5 A and a peak current of 15 A. In order to run motors of different power and different rated voltage it is possible to vary the intermediary circuit voltage in a wide range by changing the power supply.

MTR 24...60/5-15 5 21.02.2006 3. TECHNICAL DATA Rated voltage 24...60 V Rated current 5 A Pulsed current 15 A Secondary transformer voltage 18...54 V AC / 5 A 15-0-15 V / 0.3 A Voltage range of the set value inputs 0 to ± 10 V Input impedance of set value inputs 44 ks 5 10 nf Control range of input attenuators 17-100 % Maximum tacho voltage ± 20 V Control range of tacho attenuators 17-100 % Maximum input drift ± 15 :V / C Bandwidth of cascade current controller 1 khz Clock frequency to earth 9 khz Minimum load inductance 0.8 mh Frequency of current ripple 18 khz Form factor of output current with minimum load inductance (0.8 mh) 1.01 Efficiency 95 % Capacity of I 2 t OC-output 50 V / 50 ma Contact "ready" disturbance = open Auxiliary voltage for external additional circuits ± 12 V / 20 ma Max. operating temperature -20... 50 C Storage temperature -30... 70 C Fitting position vertical Cooling convection 4. CONTROL PRINCIPLE In a traditional DC motor there are two static magnetic fields which react together. The commutation of the armature winding is carried out by means of brushes and commutator segments. The principle of speed control with cascade current control is applied here. The overriding speed control circuit consists of speed controller and the motor-(tacho)-combination. The speed set value is preset externally by the user, e.g. by means of potentiometers or NC control system. The actual speed value is determined directly at the motor shaft, e.g. by means of a tacho generator, and is compared with the speed set value at the first accumulation point. The determined difference is the input value of the speed controller. From this control difference, the requested circuit set value which is passed on to the subordinate control circuit is calculated. The current control circuit consists of the current controller, the pulse-width modulator and the final stage of the amplifier. The actual current value is measured in the motor circuit and returned to the accumulation point. Set value and actual value are compared and the difference is supplied to the amplifier which adjusts it to zero.

MTR 24...60/5-15 6 21.02.2006 5. INPUTS 5.1 Speed set value inputs The speed set value can be supplied alternatively or combined by addition via the set value inputs 1 and/or 2. Both set value inputs are a differential inputs. The differential input has several advantages compared with the earth referenced input: common mode interference is suppressed and earth loops, which result in offset voltages, are interrupted. A disadvantage of the differential input is that the set value has to be supplied by two phases. Preferably set value voltages up to ± 10 V should be supplied. The input impedance of the set value inputs is 44 kohm à 10 nf. The inputs may be attenuated by means of P101 and P102 in the range of 17... 100 %. Inputs that are not needed have to be connected to earth in order to exclude disturbances that could be caused by pick-ups. 5.2 Current limitation input The current limitation input is usually needed for machines, e.g. in order to avoid the case of malfunctioning parts being moved by the drive with full torque and possibly damaging the machine, or e.g. in order to limit the winding tension at winding drives. Via this input the maximum available torque is always reduced! The range of the input voltage is 0... +10 V, where +10 V corresponds to a motor current of 15 A. The input impedance is > 22 kohm à 10 nf. 5.3 Disable input The disable input is active high, i.e. for an open input or positive input voltage > +10 V the motor is disabled. For an input voltage of 0 to +1 V the motor is enabled. Do not supply this input with a negative voltage or a positive voltage of over +20 V!! The input resistance is 10 kohm. The final stage is switched off and released immediately when this input is active. 5.4 Tacho input The tacho input is a differential input and is designed for a tacho of 5 V / 1000 rpm, this produces a range of tacho input voltage of -20... +20 V. For other configurations, we offer modified amplifiers. 5.5 Integral disable For positioning, the integral conduct of the controller is not required in all phases of a positioning process. Especially when reaching the set position, overshooting is possible. Therefore the integral part of the speed controller can be switched off by disconnecting this input from ground. This control input can also be used if in case of a set-value of 0 V the maximum holding torque is not desired. In case of the integral part being switched off, the holding torque is only weak which prevents the motor from drifting off with a large torque (remaining deviation). 5.6 Limit switch "positive stop" This pin must be connected to ground if the motor must run in positive direction. If this connection is interrupted, e.g. by a limit switch (opener), positive set-values are suppressed and the motor is braked with the adjusted pulse current. "Negative" speed is still possible.

MTR 24...60/5-15 7 21.02.2006 5.7 Limit switch "negative stop" This input has the same function as the positive stop input, but only for negative set-values. If a "positive/negative stop"-input is active, the integral part of the controller is also switched off. 6. SUPPLY 6.1 Auxiliary voltage inputs The auxiliary voltages are needed in order to supply the complete control electronics with the necessary voltage. In case of separate supply sources for auxiliary and intermediary circuit voltage, the auxiliary voltages must be switched on first and switched off last. An alternating voltage of 15-0-15 V AC / 0.3 A is needed. Higher values are not recommended as the dissipated energy increases unnecessarily which brings about an unnecessary increase of the heating of the amplifier. With battery supply it is also possible to connect a DC-DC-converter; make sure that the remaining ripple is < 0.1 V. 6.2 Supply of the intermediary circuit The supply of the intermediary circuit is done by means of a transformer, the secondary voltage of which should not exceed 54 V AC, as otherwise the ballast circuit is activated and could switch off the amplifier! The secondary voltage must not exceed 60 V DC even at a short-time excess-voltage, as otherwise the electrolytic capacitors could explode. The secondary current of 5 A AC is sufficient if the maximum nominal current is not needed permanently. However, in case of higher demands we recommend a secondary current of 7 A. Should an adjustment of the motor voltage be necessary, a lower transformer voltage is requested. The reference value is: Utransfo = (Umot + 10) * 0.72 where Utransfo is the transformer secondary voltage, and Umot is the motor's nominal voltage. The minimum voltage should not be lower than 15 V AC. 6.3 Battery supply In the case of battery supply, use the DC-inputs provided for this; make sure that the polarity is correct! The DC voltage may vary from 15 V...65 V. In the case of battery supply and correct connection the generated brake energy is fed back to the battery.

MTR 24...60/5-15 8 21.02.2006 7. OUTPUTS 7.1 I 2 t output The I 2 t output is an open collector output which, after a current of over 5 A has been output for approximately 3 seconds, switches with a low impedance to earth. Parallel to this the yellow LED (I 2 t) is illuminated. The output can be loaded with a maximum of 50 ma and can have a maximum voltage of +50 V to earth. 7.2 Output "ready" The output "ready" is an open collector output which is switched to ground during operation. In this case, the green LED is illuminated, in case of malfunction it shows red and the contact is open. The contact can be loaded with a maximum of 50 ma or 50 V. 7.3 Actual current value output At this output the actual current value can be measured with a voltmeter with an input resistance of > 10 K ohms. The voltage that can be measured is proportional to the current flowing at that moment. The relationship is 3.375 V (pulse current) per 15 A, i.e. for an output current of 1 amp, the voltmeter reading will be 225 mv. 7.4 Motor output At the motor outputs only motors of an inductance of > 0.8 mh should be connected directly. When motors of a lower inductance are used, a choke of => 0.4 mh has to be connected in each positive and negative motor line. The amplifier is short-circuit proof and short to earth proof if such a fault occurs behind chokes of at least 0.4 mh! Short circuits and shorts to earth directly at the amplifier's outputs can lead to the breakdown of the appliance; we cannot guarantee for any of these cases.

MTR 24...60/5-15 9 21.02.2006 8. ADJUSTMENT POSSIBILITIES Potentiometer P1: attenuation for set value input 1 control range 17...100% Potentiometer P2: attenuation for set value input 2 control range 17...100% Potentiometer P3: attenuation for tacho feedback control range 17...100% Potentiometer P4: offset adjustment of speed controller (motor standstill at set value = 0 V) Potentiometer P5: amplification of the alternating voltage of the speed controller Potentiometer P6: continuous current limitation Potentiometer P7: emf feedback (corresponds to P3 in the case of tacho control) Potentiometer P8: IxR compensation (for the compensation of the internal motor resistance) LED 1 (green): LED 1 (red): LED 2 (yellow): illuminated if amplifier is ready (also in the case of disable) illuminated in case of disturbance (over voltage, over current, over temperature). If this LED is illuminated, the amplifier must be switched off and on again. illuminated if the amplifier is in I 2 t-limitation JP1: JP2: bridge between 1 and 2 for current controller bridge between 3 and 4 for tacho control bridge between 1 and 2 for emf-control CN2 test points: 1 for e.m.f. 2 for motor current 3 for tacho voltage 4 for input 1 5 for input 2 6 earth

MTR 24...60/5-15 10 21.02.2006 9. CONNECTIONS 48 POL-DIN-41612 structural shape E-Male 2a current limitation output 2c ready for work (open collector output) 2e I 2 t information 4a GND 4c 15 V AC / 0.3 A 4e 15 V AC / 0.3 A 6a current limitation input 6c + 12 V max. 20 ma 6e - 12 V max. 20 ma 8a tacho + 8c tacho - 8e set value input 1 non inverting 10a set value input 2 non inverting 10c set value input 1 inverting 10e set value input 2 inverting 12 a negativ stop 12c integral part off 12e disable 14a positive stop 18ace motor - 20ace motor + 24ace intermediary circuit supply DC + UB 26ace intermediary circuit supply AC 28ace GND 30ace intermediary circuit supply DC 0 V 32ace intermediary circuit supply AC 10. WIRING AND EARTHING All control cables must be screened. The screen of the control cable must be connected to the control unit - and not to the amplifier! If the screen is earthed at both ends the advantages of the set value differential input are lost and, additionally, interference may arise. The motor cable should be a 2 core cable. To reduce interference the cable should be screened. Connect the screen to the amplifier's earth. The cores of any chokes should also be connected to the earth of the amplifier in order to avoid malfunction.

MTR 24...60/5-15 11 21.02.2006 11. INITIAL OPERATION 11.1 Preparation The amplifier is preadjusted by us. In case of an eventual maladjustement, we recommend adjusting the amplifier as follows: - set input attenuators P1 and P2 to the mid position - set tacho pot P3 to the mid position - set amplifiying pot P5 to the left position - set offset pot P4 to the mid position - for e.m.f. regulation set P7/8 to the mid position If possible, the initial operation should be performed with the motor connected and the load detached! If a tacho is used, special attention has to be taken to the correct polarity at the amplifier's input! In the case of a wrong connection, the motor can work at full torque and the speed set value will not have any influence on the speed. The disable input is opened. When starting, preset the set value to 0 V. After switching of the disable input the motor should develop a holding torque and may drift a little. If small set values are input, the motor should follow. If the amplifier is used as current controller, the motor must not show any noticeable torque at set value = 0 V. At low set values, the motor also runs in one direction with high speed; however, the torque that the motor can develop depends on the set value. If any disturbances occur during the initial operation, please read chapter 13. 11.2 Adjustment of pulsed current and continous current limit The appliance delivers a pulsed current of 15 A. In order to limit this current, the current limitation input can be supplied with a voltage < 10 V. 10 V at this input corresponds to 15 A. O V at this input corresponds to 0 A. The continous current limit is adjusted via the pot P6. We recommend limiting the continous current limit so that it corresponds to the nominal current of the driven motor, in order to protect the motor in the case of a mechanically blocked shaft or excess load. 11.3 Speed adjustment In order to adjust the maximum speed, a set value of maximum 10 V is supplied to a set value input. The desired final speed is adjusted via tacho potentiometer P3 or via P7 in case of emf-control. If this adjustment doesn't result in a stable control behaviour, we recommend turning the tacho pot P3 (or e.m.f. pot P7) further to the right (higher speed) and then adjust the final speed with the input attenuator P1 or P2. With e.m.f. control a speed deviation between the operation without load and with load can be minimized via P8.

MTR 24...60/5-15 12 21.02.2006 11.4 Offset adjustment Now, after all the previous adjustments have been effected, the offset adjustments can be made. For this purpose, a set value of 0 is supplied again and any drifting of the motor shaft is eliminated by adjusting P4. 11.5 Ballast circuit (not included in the amplifier) The motor's braking energy is absorbed by the electrolytic capacitor. If the energy is too great, due to frequent braking or high inertia loads, an overvoltage will occur and in these circumstances the ballast circuit is required. 11.6 Dimensions MTR 24...60/5-15

MTR 24...60/5-15 13 21.02.2006 11.7 Wiring diagram MTR 24...60/5-15 11.8 Wiring diagram MTR 24...60/5-15

MTR 24...60/5-15 14 21.02.2006 11.9 Plan of components MTR 24...60/5-15

MTR 24...60/5-15 15 21.02.2006 12. OPTIMIZATION OF THE CONTROL BEHAVIOUR 12.1 Alternating voltage gain In most of the cases the optimization is limited to the adjustment of the alternating voltage gain at pot P5. The alternating voltage gain determines the torque and therefore the speed with which the amplifier readjusts (dynamic stiffness). For this purpose, couple the motor to the load and supply a set value of 0 V. This can be done by bridging the set value input. Turn pot P5 to the right until oscillation starts and then turn in immediately to the left in order fo find the point at which oscillation stops. 12.2 Direct voltage gain Especially in case of an overriding position control circuit an exactly defined static stiffness is required. This corresponds to the torque with which a position is held. In order to change the stiffness use resistor R21. With increasing resistance the stiffness decreases. The static stiffness mustn't be confused with the dynamic stiffness which is adjustable at P5. 12.3 Integral part of the speed controller The capacitor C6 is responsable for the integral part of the speed controller. The demands on the dynamics of amplifiers working as speed controllers differ considerably from the demands on amplifiers working with overriding position control circuits. In the first case, stiffness has to be produced by the speed controller which therefore must have an integral gain as high as possible (C6 must be large). In most applications a short-time overshooting is allowed. In operation with an overriding position control circuit, the position control circuit produces the stiffness. It is of great importance that the amplifier has a band width as large as possible whereas the integral gain can be considerably lower than in the first case (C6 has to be decreased). The overshooting of the amplifier without position control gets a little smaller, however, the braking time till motor standstill is a little longer.

MTR 24...60/5-15 16 21.02.2006 13. TROUBLE SHOOTING Faults: No reaction, green LED is not illuminated Green LED is illuminated, no other reaction There is a reaction, but no torque at the motor shaft Noise interference in motor current Motor runs uncontrolled at high speed. Possible causes: Check the DC power voltages. If one of the voltages are missing, check the wiring. No contact at limit switch (enable/disable) input. Break in motor circuit. Check motor output with a voltmeter. Check the fuse on the final stage PCB. Is the current set value = 0? Is P6 on the left position? Common-mode interference at the differential input is to high. Install a separate earth cable from terminal 28ace to the central 0 V-point of the control unit. Absence of tacho voltage or incorrect tacho connection polarity. Jumper JP1 on I-control. Maximum motor speed is too low Set value is too low, tacho voltage is too high, operation voltage is too low, load too high. Input potentiometer P3 on right position; check operation voltage and compare with motor e.m.f. at the desired speed; increase pulse or maximum continuous current for a short time in order to prove the overload: the speed should increase. Too much drift Over current alarm (with internal disable) at high speeds Audible howl at constant frequency and motor shaft instability Imprecise regulation with a large overshoot even with low gain Rumbling, rhythmic running noise with early activation of I 2 t limit Unfavourable input circuitry; inputs are reduced; interference voltage at the input cables. Potentiometer of input on maximum. Screen the input cables. Check connections with regard to earth currents. Commutation limit of motor exceeded; choose smaller operation voltage and/or reduce peak current. Torsional resonance due to weak attachment of tachogenerator. Improve the tacho/motor coupling or use a tacho with a lower moment of inertia. Inductive phase angling rotation due to a large motor inductivity and small mechanical time constant. Use a motor with a smaller inductivity; increase the working voltage. Tacho voltage ripple too large, use a better tacho or reduce the amplifier's gain (P3). Continuous available power too low, current limit activates too early Load too large, possibly friction losses or constraints in the machine. Check the actual motor current. Avoid unnecessary high accelerations and decelerations.

MTR 24...60/5-15 17 21.02.2006 Motor gets hot, even without load Temperature rise due to hysteresis losses. Reduce operating voltage or attach reactors (chokes)in series with the motor. Electrical interference too high Wiring not correct. Mount reactors (chokes) directly adjacent to the amplifier and ground the cores to terminal 28 ace. If controlling the amplifier from an external control system ground the control input cable screens AT THE CONTROLLER and not at the amplifier. Insert 330 ohm resistors in the control lines from the external controller. 14. WIRING DIAGRAM AS POSITIONING AMPLIFIER MTNR 24...60/5-15