Laboratory Accreditation Programmes

Similar documents
National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

National Voluntary Laboratory Accreditation Program

BIODEX MULTI- JOINT SYSTEM

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

National Voluntary Laboratory Accreditation Program

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

American National Standard for Methods of Measurement. Frequency allocations and radio treaty matters; general rules and regulations

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

ANSI-ASQ National Accreditation Board/ACLASS

HeRO duet

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 1, Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

EMC Test Report. Report Number: M030826

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Powered Traction Unit OPERATION MANUAL

Ackrediteringens omfattning/scope of accreditation

General Safety/EMC and Electrical Information for i-limb ultra and i-limb digits

National Voluntary Laboratory Accreditation Program

English

IEC Second Edition

Accr. 002-Test EN-ISO (2005)

EMC Requirement for LED Lighting and Accessories & EMC Facilities in SIRIM

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Technical Specifications Micromedical VisualEyes 505 by Interacoustics

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

TEST REPORT. Power Spout PLT V. tested to the specification

ANSI-ASQ National Accreditation Board/ACLASS

Biological Safety. Electromagnetic Compatibility (EMC) Observe the following precautions related to biological safety.

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

EMC Test report for LED Panel Light Models , , , , ,

Power Quality Issues from an EMC Point of View

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

R&TTE Testing For EU Market

~W~~~ Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC rd Drive S.E., Suite A Bothell, WA Steve Behm Phone:

EMC aspects associated to 5G networks

XMU+ Environmental, Safety and Specifications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. MiCOM LABS 575 Boulder Court Pleasanton, California USA Gordon Hurst Phone: (+1)

The equipment will provide up to 50W RF output power in the MHz band.

Announced on the 7 th day of May B.E (2010)

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

HEC-70LCN-350TDAF Rev B

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

TEST REPORT. Power Spout PLT V. tested to the specification. EN : Amendment 1: Electromagnetic compatibility (EMC)

INTRODUCTION TO CONDUCTED EMISSION

VN415/VO425 Specifications

Australian/New Zealand Standard

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Emerging Standards for EMC Emissions & Immunity

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

(c) Medisave UK. Notice. Edition 1. i-pad Operator s Manual

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC Sierra Pines Drive Mariposa, CA Steve Behm Phone:

HI-Physix Laboratory, L-83, Sector-1, DSIDC Industrial Area, Bawana, Delhi. Discipline Electronics Testing Issue Date

EUROPEAN pr ETS TELECOMMUNICATION November 1995 STANDARD

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

AS/NZS 4583:2016. Amplitude modulated equipment for use in the aeronautical radio service in the frequency range 118 MHz to 137 MHz AS/NZS 4583:2016

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

User Instruction Computer Assisted Local Analgesia. 337 Marion, Le Gardeur QC, Canada, J5Z 4W8

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CKC LABORATORIES, INC. 110 North Olinda Place Brea, CA Steve Behm Phone:

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

TEST REPORT... 1 CONTENT...

ANCOM s Laboratory for Electromagnetic Compatibility and Radio Equipment Testing

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Appendix A: Specifications

HEC-45LTN-45PFAS Rev A

LIST OF PUBLISHED STANDARDS

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Technical Specification

For the National Voluntary Laboratory Accreditation Program

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

Power Factor (2) 600 ma 90 ~ 305 Vac Vdc 34.2 W 86% 0.95 LUC-040S060RSP. Efficiency (2) Parameter Min. Typ. Max. Notes

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

D C 01/2019 3

Transcription:

Laboratory Address PO Box 68307, Newton, Auckland, 1145 47 Mackelvie Street, Grey Lynn, Auckland, 1021 Telephone 09 360-0862 Fax 09 360-0861 URL Authorised Representative Client No. 2218 Programme Accreditation Number 424 www.emctech.com.au Mr Andrew Cutler Initial Accreditation Date 24 June 1991 Electrical Testing Laboratory Conformance Standard NZS ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories Testing Services Summary 3.41 Radiocommunications Equipment 3.42 Electromagnetic Compatibility Testing Signatories Mr Murray Burr 3.42 Mr Andrew Cutler 3.41, 3.42 Issue 43 Date: 02/11/16 Page 1 of 8

3.41 Radiocommunications Equipment (a) (b) Receiving equipment Transmitting equipment The following tests on analogue AM and FM, VHF and UHF transmitters and receivers in accordance with In-house methods and the methods specified below. Measurements are made over the ranges given. i) Transmitter power ii) Frequency stability iii) Case radiation iv) Spurious emissions v) Effective radiated power vi) Frequency deviation vii) Adjacent channel power viii) Intermodulation attenuation ix) Co-channel rejection x) Adjacent channel selectivity xi) Intermodulation response xii) Blocking xiii) Modulation distortion xiv) Transmitter transient performance xv) Emission masks METHODS AS/NZS 4295: VHF/UHF Analogue Speech Equipment RSS 119 Land Mobile and Fixed Ratio Transmitters and Receivers 27.41 to 960 MHz (i, ii, iii, iv, xiii, xiv and xv above) FCC parts 2, 22 and 90 (i, ii, iii, iv, xiii, xiv and xv above) AS/NZS 4415 VHF Maritime Mobile Equipment AS/NZS 4365: UHF Citizen Band radio and Personal Radio Service VHF and UHF fixed services AS/NZS 4268, EN 300-220-1, EN 300 330: Low powered radio equipment AS/NZS 4281: Cordless telephones EN 300 086, EN 300 113, EN 300 328 Issue 43 Date: 02/11/16 Page 2 of 8

ETSI EN 302 291-1, ETSI EN 302 291-2: Close range inductive data communication equipment operating at 13.56 MHz MEASUREMENT RANGE 100 khz to 4000 MHz 1 nw to 1000 watts below 1 GHz 1 nw to 30 watts 1 GHz to 18 GHz Frequency reference 1 part in 10 9 Frequency modulation deviation 10 Hz in 10 khz Temperature 30 C to + 60 C 3.42 Electromagnetic Compatibility Testing Determination of radio interference and immunity characteristics of industrial, scientific and medical radio frequency equipment, sound and television receivers, household appliances and similar apparatus, fluorescent lamps and luminaires and information technology equipment. Tests performed are: In accordance with the following: (a) Radiated emissions Radiated Electric Field Emissions (incl. Low power tx & case radiation) 25 MHz to 18 GHz CISPR 11, AS/NZS CISPR 11 3, 10 and 30 metre measurement CISPR 12, AS/NZS CISPR 12 distances CISPR 13, AS/NZS CISPR 13 AC mains single and 3 phase CISPR 22, AS/NZS CISPR 22 supply up to 16 amps AS/NZS CISPR 14 CISPR 16-1 CISPR 16-2 EN 55011 EN 55022 EN/ IEC 61000-6-3 EN/ IEC 61000-6-4 EN 300 086 EN 300 220-1 Issue 43 Date: 02/11/16 Page 3 of 8

FCC - CFR, Part 15 Subparts A, B, and C FCC - CFR, Part 18 ANSI C63.4 FCC - CFR, Part 2 AS/NZS 4268 AS/NZS 4281 Radiated Magnetic Field Emissions (including Van Veen Loop measurements) 9 khz to 30 MHz CISPR 11 CISPR 15 AS/NZS CISPR 11 AS/NZS CISPR 15 EN 55011 EN 55015 EN 300 330 ETSI EN 302 291-1, ETSI EN 302 291-2 FCC - CFR, Part 15 Subparts A, B, and C ANSI C63.4 FCC - CFR, Part 18 Note: All radiated emission measurements are carried out at the laboratory s open area test site. (b) Radiated immunity Radiated Electromagnetic Immunity Testing 27 MHz to 2800 MHz IEC/EN 61000-4-3 1 V/m, 3 V/m, 10 V/m Radiated field area 0.5 m x 0.5 m IEC AS/NZS 60335.1 clause 19.11.4.2 maximum Issue 43 Date: 02/11/16 Page 4 of 8

, 4, 5 Power frequency magnetic immunity EN/IEC 61000-4-8 (c) Conducted emissions AC/DC power port conducted emissions Telecom port conducted emissions 9 khz to 30 MHz CISPR 11 Single phase up to 240 Vac CISPR 13 Three phase up to 415 Vac CISPR 14 and 32 amps CISPR 15 CISPR 22 CISPR 16-1 CISPR 16-2 AS/NZS CISPR 16-1 AS/NZS CISPR 14 AS/NZS CISPR 13 AS/NZS CISPR 11 AS/NZS CISPR 22 AS/NZS CISPR 15 FCC-CFR, Part 15, Subparts A, B, C FCC-CFR, Part 18 ANSI C63.4 FCC-CFR, Part 2 EN 55011 EN 55014 EN 55015 EN 55022 IEC 61000-6-3 IEC 61000-6-4 Issue 43 Date: 02/11/16 Page 5 of 8

Disturbance Power Measurements 30 MHz to 300 MHz CISPR 14-1 AS/NZS CISPR 14 EN 55014-1 CISPR 13 AS/NZS CISPR 13 Local Oscillator Voltage Measurements 30 MHz to 2150 MHz CISPR 13 AS/NZS CISPR 13 Video RF Output Measurements 20 MHz to 2150 MHz CISPR 13 AS/NZS CISPR 13 Discontinuous Noise Measurements 0.15 MHz to 30 MHz CISPR 14 EN 55014 IEC 61000-6-3 IEC 61000-6-4 AS/NZS CISPR 14 Harmonic current emissions EN/IEC 61000-3-2 DC to 40 th harmonic 240 Vac, up to 16 A per phase Voltage changes, fluctuations and flicker EN/ IEC 61000-3-3 240 Vac, up to 16 A per phase (d) Conducted immunity Electrostatic Discharge Up to 15 kv air discharge IEC 61000-4-2 EN 301 489 1/ EN 304 489-3 EN 301 489 1/ EN 304 489-4 IEC AS/NZS 60335.1 clause 19.11.4.1 Issue 43 Date: 02/11/16 Page 6 of 8

Up to 8kV contact discharge IEC 61000-4-2 IEC AS/NZS 60335.1 clause 19.11.4.1 EN 55014-2 Electrical Fast Transients AC mains up to 240 V single phase, IEC 61000-4-4 16 amps Power port and IO, single and control port available Voltage 200 V to 4000 V +ve & -ve tburst 0.1 ms to 20 ms fburst (0.1 to 2.5, 5, 100) khz> 2kV EN 55014-2 AS/ NZS 3200.1.2 IEC AS/NZS 60335.1 clause 19.11.4.3 Surges 0.5 kv to 2.0 kv (line to line) IEC 61000-4-5 0.5 kv to 4.0 kv (line to ground) EN 55014-2 IEC AS/NZS 60335.1 clause 19.11.4.4 Voltage dips and short interruptions Issue 43 Date: 02/11/16 Page 7 of 8

DC Current Max 24 A IEC 61000-4-11 AC Voltage Max 280 Vrms EN 55014-2 EN 60601-1-2/IEC 60601-1-2 IEC AS/NZS 60335.1 clause 19.11.4.6 Radio frequency injected currents 1 V, 3 V, 10 V IEC 61000-4-6 EN 55014-2 IEC AS/NZS 60335.1 clause 19.11.4.5 Harmonics and interharmonics IEC/EN 61000-4-13 IEC AS/NZS 60335.1 clause 19.11.4.7 Issue 43 Date: 02/11/16 Page 8 of 8