USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Similar documents
USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

User Guide. EasyView Digital Light Meter. Model EA31

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

400Amp True RMS AC Clamp Meter + NCV

User s Guide. Model MA A AC Mini Clamp-on Meter

Laser Distance Finder Extech DT500

Non-contact Forehead IR Thermometer

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

User s Guide. Digital AC/DC Clamp Meter Model 38394

USER GUIDE. IR Thermal Scanner. Model IRT500

Laser Distance Finder Extech DT500

User Guide. Digital AC/DC Clamp Meter Model 38394

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User s Guide. 400A AC/DC Clamp Meter. Model MA220

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Carbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations

200Amp AC Clamp Meter + NCV Model MA250

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

R/C SMD Tweezers Multimeter Model RC200

USER MANUAL. Multi Field EMF Meter. Model EMF Washington Street Melrose, MA Phone Toll Free

400Amp True RMS AC/DC Clamp Meter Model EX613

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User Manual 4 wire Earth Resistance Tester Model GRT300

User Guide. AC/DC Mini Clamp Meter. Model

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

Micro-Ohmmeter Model UM200

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

EasyView Light Meter with Memory

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

RF/High Frequency Meter HF-A3G

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Microwave Meter. Instruction Manual

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Autoranging Multimeter Extech EX503

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

User s Manual. Ground Resistance Clamp On Tester MODEL

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Pen Multimeter. Model

Digital Multimeter, Pen Type

Non-contact Forehead IR Thermometer

Magnetic Field Meter EM-191

True RMS AC / DC Power Clamp Meter Model

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Compact MultiMeters + Voltage Detector

Pen-type DIGITAL MULTITESTER

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Electrical Multimeter

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

ProfiScale MULTI Multimeter

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User's Manual. Clamp-on Power Datalogger. Model

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

CONTENTS MS2033A. 1.Introduction Safety Information...01

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

Passive Component LCR Meter

P20 Zoom Flash Zoom Flash P20 P20 Zoomblitz Flash con zoom P20 Flash externo P20 Flash Zoom P20

ET-3888 True RMS Clamp Meter. User Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

RF EMF Strength Meter

DM-45 Digital Multimeter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

Mini Clamp Meter Model:

USER'S MANUAL DMR-6700

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Triple Axis RF/High Frequency Meter HF-B3G. User s Manual HB4HFB3G0000

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Printing Humidity/Temperature Meter

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

IDM 98-III & IDM 99-III Digital Multimeters

User s Guide. Combination Photo-Tachometer Stroboscope Model

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Passive Component LCR Meter

Pro Triple Axis RF/High Frequency Meter HF-B8G. User s Manual HB4HFB8G0000

Transcription:

USER MANUAL UV AB Light Meter Model UV0 Additional User Manual Translations available at www.extech.com

Introduction Thank you for selecting the Extech Model UV0 UV AB Light Meter. This device measures UV AB ultraviolet light in the wavelength range of 290~390nm. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version and translations of this User Manual, Product Updates, and Customer Support. Features Professional, high quality UV meter Measures ultra violet irradiation Wavelength range 290 nm to 390 nm Two measurement ranges for greater accuracy (0~3999 µw/cm 2 / 0~39.99 mw/cm 2 ) Auto power off after 1 minutes Lightweight, ergonomic design General Safety Please read the entire User Manual before operating this device. Use the meter only as specified and do not attempt to service or open the meter housing. Do not allow children to handle the meter or the protective cover. Please dispose of batteries and meter responsibly and in accordance with all applicable laws and regulations. To prevent damage to this precision device, do not attempt measurements outside of the ranges specified in this manual Do not use this meter in direct sunlight or any place where it is excessively hot and/or humid Do not submerse the meter in liquid UV Safety Information Use extreme caution when using this meter to test an ultraviolet light source. Exposure to UV radiation can be hazardous depending on the exposure time, intensity of radiation, wavelength and an individual s sensitivity to ultraviolet. Meter Description 1. Light Sensor (protective cover not shown) 2. LCD 3. Backlight button 4. Zero button. Power ON OFF button 6. Unit of measure toggle button 7. Display Data Hold button Note: Battery compartment and tripod mount are located on the back of the meter 1 2 3 4 6 7 2

LCD Description 1. Measurement Reading 2. Data Hold 3. Zero mode 4. Low battery indicator. Unit of measure (µw/cm 2 or mw/cm 2 ) 1 2 3 4 HOLD ZERO uw/cm mw/cm Button Descriptions Press to turn the meter ON or OFF Press to freeze/unfreeze the readings on the display Short press to toggle between µw/cm 2 and mw/cm 2 Operation Meter Power Short press to power ON the backlight. The backlight switches OFF automatically after 10 seconds. With the protective cover over the sensor, press to zero the display. Press again to exit. Short press the power button to switch the meter ON/OFF. If the LCD does not switch on, check the batteries located in the rear battery compartment. The meter powers off automatically after 1 minutes of inactivity. Zero the Sensor With the sensor s protective cover attached, short press the button to zero the display before taking measurements. The ZERO display alert will appear while the meter is zeroing. Press the button again to exit the mode; the ZERO display alert will switch off. Taking Measurements Remove the sensor cover and aim the light sensor at the UV light source. View the measurement on the meter s display. Selecting Range and Unit of Measure Short press the button to toggle the range (mw/cm 2 and µw/cm 2 ); the lower display area will show the selected range. 3

Data Hold Short press the button to freeze or unfreeze a reading on the display. Backlight The LCD is equipped with backlighting for easier viewing, especially in dimly lit areas. Short press the backlight button to turn on the backlight. The backlight will automatically turn off after 10 seconds. Measurement Considerations Keep the light sensor clean and free of scratches. Dust lightly with dry lint free cloth. Avoid reflections or shadows on the sensor while taking measurements. For best accuracy, repeat the measurement several times to ensure that the light source has remained stable. Maintenance Battery Replacement 1. Power OFF the meter. 2. Press and hold the locking button above the battery compartment (back of the meter) and slide the battery compartment door off in a downward motion. 3. Replace the two AAA 1.V batteries observing correct polarity. Re assemble the meter before use. Battery Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the batteries and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end oflife devices to a designated collection point for the disposal of electrical and electronic equipment. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. Use a dry lint free dust cloth to clear debris and dust from the sensor. Avoid any materials that could potentially scratch the sensor surface. 4

Specifications Display Sampling rate Measurements UV sensor spectrum Peak Sensitivity Wavelength Input Overload Display Tripod mount Power Battery life Automatic power off Operating Temperature/Humidity Operating Altitude Storage Temperature/Humidity Dimensions/Weight Safety Electrical Specifications (23± C) Ultraviolet (UV AB) Backlit 3 3/4 digit (4000 count) LCD Size: 3 x 30mm (1.4 x 1.2 ) Approx. 3 seconds Ultraviolet Light (UV AB) 290 to 390 nm 36 nm OL On rear panel 2 x 1.V AAA batteries Approx. 0 hours After approx. 1 minutes of inactivity to 40 o C (41 to 104 o F) / 80% RH max 2000 meters (7000ft) maximum 10 to 60 o C (14 to 140 o F) / 70% RH max 133 x 48 x 23mm (.2 x 1.9 x 0.9 ) /90g (3.2oz) For indoor use only. EMC: EN61326 (1997), A1 (1998), A2 (2001); Pollution degree 2 Unit Range Resolution Accuracy mw/cm 2 0 to 39.99 0.01 ± 4% full scale µw/cm 2 0 to 3999 1 ± 4% full scale Customer Support Support Lines: U.S. (877) 239-8324 International: +1 (603) 324-7800 Tech Support: Option 3; Repair/Returns: Option 4 Tech Support E-mail: support@extech.com; Service E-mail: repair@extech.com Copyright 2017 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com