Simple method of determining the axial length of the eye

Similar documents
MEASUREMENTS OF THE SAGITTAL AXIS OF THE HUMAN

Macrophotography of the anterior

OCULAR MEDIA* PHOTOGRAPHIC RECORDING OF OPACITIES OF THE. development by the control of diabetes, the supply of a deficient hormone

DEFECTS OF VISION THROUGH APHAKIC SPECTACLE LENSES*t

Non-linear projection of the retinal

OPTICAL SYSTEMS OBJECTIVES

QUANTITATIVE STUDY OF VISUAL AFTER-IMAGES*

THICKNESS OF THE HUMAN CORNEA*

clip Calculation of the power of an iris lens for distant vision ~~~~~~~~~~~~~~~~~~~~~~t P/L2PIL FLI specification: The Netherlands

An analysis of retinal receptor orientation

nearly to that of the sclerotic. Instead of the normal radius

E X P E R I M E N T 12

Image formation in fundus cameras

Kodak (ASA 400). image by computer. A given point (xi, yi) was. xi is the distance from the axis in the optical image,

GEOMETRICAL OPTICS Practical 1. Part I. BASIC ELEMENTS AND METHODS FOR CHARACTERIZATION OF OPTICAL SYSTEMS

11/10/2015. Haag Streit Topcon Zeiss Kowa Add On Systems- OIS/Escalon and Others. The Original Design. Photo Slit lamp Systems. Who Makes Them?

always positive for virtual image

What s Fundus photography s purpose? Why do we take them? Why do we do it? Why do we do it? Why do we do it? 11/3/2014. To document the retina

Lecture 2 Slit lamp Biomicroscope

PRINCIPLE PROCEDURE ACTIVITY. AIM To observe diffraction of light due to a thin slit.

Chapter 34. Images. Copyright 2014 John Wiley & Sons, Inc. All rights reserved.

This experiment is under development and thus we appreciate any and all comments as we design an interesting and achievable set of goals.

Aberrations of a lens

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

SMALL VOLUNTARY MOVEMENTS OF THE EYE*

Chapter 9 - Ray Optics and Optical Instruments. The image distance can be obtained using the mirror formula:

REFLECTION THROUGH LENS

Chapter 18 Optical Elements

Section A Conceptual and application type questions. 1 Which is more observable diffraction of light or sound? Justify. (1)

Training Eye Instructions

Basic Principles of the Surgical Microscope. by Charles L. Crain

COMMUNICATIONS THE ACCOMMODATION REFLEX AND ITS STIMULUS* powerful stimulus to this innervation is to be found in the disparity

Imaging Instruments (part I)

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Lens Principal and Nodal Points

Human Visual System. Prof. George Wolberg Dept. of Computer Science City College of New York

EXAMINATION OF THE CENTRAL VISUAL FIELD AT

2. The radius of curvature of a spherical mirror is 20 cm. What is its focal length?

Laboratory 7: Properties of Lenses and Mirrors

Lenses. A lens is any glass, plastic or transparent refractive medium with two opposite faces, and at least one of the faces must be curved.

Types of lenses. Shown below are various types of lenses, both converging and diverging.

EYE-REFRACTIVE ERRORS

Retinoscopy: Research Applications

Reading: Lenses and Mirrors; Applications Key concepts: Focal points and lengths; real images; virtual images; magnification; angular magnification.

The Human Eye and a Camera 12.1

Projector for interference figures and for direct measurement of 2V.

LIGHT REFLECTION AND REFRACTION

Yokohama City University lecture INTRODUCTION TO HUMAN VISION Presentation notes 7/10/14

Chapters 1 & 2. Definitions and applications Conceptual basis of photogrammetric processing

Chapter 36. Image Formation

Chapter 36. Image Formation

Macula centred, giving coverage of the temporal retinal. Disc centred. Giving coverage of the nasal retina.

Snell s Law, Lenses, and Optical Instruments

Practice Problems (Geometrical Optics)

4,162,827. United Stat to XR 49162,827. U.S. PATENT DOCUMENTS 1,293,086 2/1919 Graf /234. Jul. 31, Assignee:

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

L. R. & S. M. VISSANJI ACADEMY SECONDARY SECTION PHYSICS-GRADE: VIII OPTICAL INSTRUMENTS

EDULABZ INTERNATIONAL. Light ASSIGNMENT

Be aware that there is no universal notation for the various quantities.

Chapter 34 Geometric Optics

10.2 Images Formed by Lenses SUMMARY. Refraction in Lenses. Section 10.1 Questions

Lenses. Optional Reading Stargazer: the life and times of the TELESCOPE, Fred Watson (Da Capo 2004).

The Bellows Extension Exposure Factor: Including Useful Reference Charts for use in the Field

Understanding your Direct Ophthalmoscope

From the late 1940s, ocular size and shape have been described

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

EYE ANATOMY. Multimedia Health Education. Disclaimer

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Lenses. Images. Difference between Real and Virtual Images

LIGHT REFLECTION AND REFRACTION

Optics: Lenses & Mirrors

Downloaded from


Instrument for measuring the misalignments of ocular surfaces

Focus on an optical blind spot A closer look at lenses and the basics of CCTV optical performances,

binocular projection by electrophysiological methods. An account of some METHODS

Supplementary Notes to. IIT JEE Physics. Topic-wise Complete Solutions

MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question.

COURSE NAME: PHOTOGRAPHY AND AUDIO VISUAL PRODUCTION (VOCATIONAL) FOR UNDER GRADUATE (FIRST YEAR)

Physics 1520, Spring 2013 Quiz 2, Form: A

Physics 1230: Light and Color. Guest Lecture, Jack again. Lecture 23: More about cameras

Final Reg Optics Review SHORT ANSWER. Write the word or phrase that best completes each statement or answers the question.

Chapter Ray and Wave Optics

Fine Recording in Time Direction for Seismological Observation

Monochromator or graded spectrum filter?

Geometric optics & aberrations

Determining MTF with a Slant Edge Target ABSTRACT AND INTRODUCTION

PART 3: LENS FORM AND ANALYSIS PRACTICE TEST

Astigmatism. image. object

LIGHT-REFLECTION AND REFRACTION

Medical Photonics Lecture 1.2 Optical Engineering

INSTRUCTION MANUAL FOR THE MODEL C OPTICAL TESTER

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

ii) When light falls on objects, it reflects the light and when the reflected light reaches our eyes then we see the objects.

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

EXPERIMENT 4 INVESTIGATIONS WITH MIRRORS AND LENSES 4.2 AIM 4.1 INTRODUCTION

family of lens designs fitting guide ICD is Exclusively Manufactured In

Guide to SPEX Optical Spectrometer

Optical Zone Diameters for Photorefractive Corneal Surgery

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Transcription:

Brit. Y. Ophthal. (1976) 6o, 266 Simple method of determining the axial length of the eye E. S. PERKINS, B. HAMMOND, AND A. B. MILLIKEN From the Department of Experimental Ophthalmology, Institute of Ophthalmology, University of London The x-ray method of determining the axial length of the eye employed by Sorsby (Rushton, 1938; Sorsby and O'Connor, I945; Duke-Elder and Abrams, 197) has been superseded by ultrasonic techniques. Although the latter have attained considerable accuracy they can hardly be used for routine clinical purposes, particularly in children. The following method was developed to fulfil this need. If the globe can be considered as a sphere rotating about a fixed point in a cup of orbital fat the movement of a point on the cornea during rotation of the globe through a known angle will be directly related to the radius of rotation. In Fig. i the eye rotates through an angle a about C to fix an object first at A and then at B. If the distance between X and Y can be measured and the angle a is known the radius of the globe CX or CY can be calculated thus: CX = 2 X sine a/2 There are two important assumptions which require further examination. First, can the eye be considered to be spherical? This may be assumed to be almost correct for a normal eye. Although the radius of curvature of the cornea is less than the radius of curvature of the globe, the apex of the cornea is said to coincide with the circumference of the globe (Duke-Elder and Wybar, I97), so that measurement of the radius from a point near the centre of the cornea to the centre of the globe will be equal to the radius of the globe. Doubling this measurement will give the axial length. In the case of a highly myopic eye, in which the globe is not enlarged symmetrically but which is elongated in its antero-posterior axis, rotation will take place about the centre of curvature of the posterior segment, and the distance from this point to the apex of the cornea will be greater than the radius of the posterior segment. A measurement derived from movement of a point on the apex of the cornea Address for reprints: Professor E. S. Perkins, Department of Experimental Ophthalmology, Institute of Ophthalmology, Judd Street, London WCiH 9QS A FIG. I When eye rotates from fixation point A to fixation point B through known angle a movement of point on cornea from X to Y will be directly related to radius of rotation will not, therefore, give the radius of the posterior segment of such an eye, and doubling this measurement will give an overestimate of the total length. If, however, the method is used to estimate the progressive increase in length of an individual eye the increase in the distance from the apex of the cornea to the centre of rotation of the posterior segment will indicate the elongation of the eye. Although therefore such an estimation of the axial length may be inaccurate in a highly myopic eye the method will still give relevant information concerning the change in antero-posterior length in any individual eye. The second assumption is that the globe rotates about a fixed point. The centre of ocular rotation in the horizontal plane was carefully measured by Park and Park (1933), who found from measurements on 14 subjects that as the eye rotated from 39 nasally to 38 temporally the centre of rotation moved along a curve slightly nasal to the visual axis and extending from a point I4-732 mm to a point I2'95 mm behind the cornea. At 4 nasally

the distance from the cornea was 13-9i8 mm, and at 3 temporally I3.749 mm. The antero-posterior movement of the centre of rotation was almost syrmmetrical about its position when the eye was in the primary position. If the centre of rotation is calculated from a symmetrical position a mean value would be obtained which, although not from the exact geometric centre of rotation, would be comparable from one eye to another. There are therefore some theoretical objections to a calculation of the radius of the globe from observations of the movement of the apex of the cornea, but as the method is simple it seemed worth trying in the hope that measurements of clinical value could be obtained. It is impossible to visualize the apex of the cornea for purposes of measurement, and observation of a small feature such as a blood vessel at the limbus was found to be difficult. However, if the fixation points A and B in Fig. I are replaced by illuminated targets in the form of a slit a bright corneal reflex can be seen and photographed by means of a camera mounted between A and B. The reflection of the target lies on the visual axis behind the cornea and its position depends on the corneal curvature. It would be possible to measure the corneal curvature (and hence to determine the position of the image) by using a keratometer, but if the targets at A and B are photographed simultaneously the corneal curvature can be obtained from the separation of the two images (A and B in Fig. i) either by calculation or by means of a calibration curve obtained by photographing a series of polished steel balls of known radius. The latter method is more convenient, as an allowance can be made for the magnification of the photographic image and the actual distance between the two images on the film can be plotted against corneal curvature. Method The apparatus employed is shown diagrammatically in Fig. 2. The reflex camera, fixation targets, etc., were mounted on a slit-lamp base placed on an instrument table. The targets were arranged on an arc, the centre of curvature of which was the focal point of the camera lens, and separated by an angle of 4 or 6o. The lens was an 8o mm Leitz Photar mounted on an extension tube which contained a small fibre-optics light guide mounted 94 mm behind and facing the lens. This provided a fixation spot for the patient during keratometry. The subject was seated with his head on the head-rest and instructed to look at the lens of the camera. In addition to a constant illumination of the test targeta slit-from a festoon bulb, a small flash tube, was placed behind each target. The images of the targets could be accurately focused by moving the instrument with the joystick of the slit-lamp base, and a photograph Determining the axial length of the eye 267 Position of eye FIG. 2 Diagram of apparatus for photographing bright corneal reflexes from fixed flash targets of the comea was taken with both targets illuminated by the flash tubes. The subject was then instructed to look at a red dot in the centre of the left-hand target and another photograph taken with the flash from this target. The shutter of the camera was kept open and the subject viewed a green dot in the centre of the righthand target while this flash was fired. The resultant frame had a photograph of the eye in the two positions of gaze, and the image of each target appeared separated by a distance which could be measured and used to calculate the radius of movement of the reflex. Photographs of each eye were taken twice. It was found convenient to place a scale calibrated in fifths of a millimetre in front of the film plane, so that an image of the scale was also obtained on the film and the separation of the reflexes could be read direct from the negative. So that the background exposure of the film would be sufficient to show the scale, the shutter was used in the 'bulb' position and kept open for about 5 s. With FP4 film the scale could be seen clearly on each frame. A switch was provided so that in one position both flashes were fired simultaneously for measurement of the corneal radius and in the second position either flash could be fired by pressing one of two buttons. This was probably an unnecessary refinement, as even if both flashes were fired with the eye in the two positions of movement it was easy to see on the film which of the two flashes was aligned with the optic axis. CALCULATIONS Keratometry Knowing the magnification of the camera ( x I -875), it was possible to derive the separation of the two images in millimetres and from this measurement to calculate the radius of curvature, knowing the actual distance between the two light sources and their distance from the cornea.

268 British Journal of Ophthalmology From a series of tests on steel ball-bearings of known diameter it was found that no serious error was introduced by multiplying the separation in millimetres of the images on the film by a constant factor of i -62, and this was used for the clinical measurements. Radius of movement of globe From Fig. i it can be seen that the image of targets placed at A and B will lie on the optic axis behind the surface of the cornea. Its position on the optic axis will depend on the curvature of the cornea and the distance between the cornea and the target. If the target is at infinity the image will be at the focal pointthat is, halfway between the centre of curvature of the comea and the corneal surface. In this apparatus the target is not at infinity and, although the position of the image could be calculated, for clinical purposes the narrow slit can be considered as a point source and the calculations simplified by considering it to be at infinity. The separation of the two images on the film is corrected by the magnification factor ( x i -875) and the radius of their movement as the eye moves from one target to the other equals their linear separation in millimetres divided by the sine of the angle of movement (usually 4). To obtain the radius of the globe the distance of the image from the anterior surface of the cornea has to be added to the radius of movement of the images. Results To test the method steel balls of known radius from to 8-73 mm were mounted on a pivot in such a way that they could be rotated with varying centres of rotation through an angle of 6. The face of the balls thereby represented the corneas of eyes of different diameter. The radii of rotation were in the range expected in human eyes and varied from IIP35 mm to I5-33 mm, representing axial lengths of 22-7 mm to 3o66 mm. The results (Table I) showed that there was fairly good agreement between the so-called true radius of rotation and that calculated from the photographs. The 'true radius' consisted of an accurate measurement of the steel ball with a micrometer added to its distance from the centre of rotation of the pivot-normally 5, 6, or 7 mm, although this distance could not be measured so accurately as that of the diameter of the balls. The mean error between the 'true radius' and the measured radius was -o ii mm (SD o ii, SE -2I3). Clinical measurements Measurements were made on 8o eyes of patients aged io or over. As expected, the axial length of eyes with small refractive errors (+ 2o D to -Io D) showed no significant correlation with axial length. The mean for male eyes was 27-95 mm and for female eyes 26-33 mm. Table I Verification of photographic measurements using steel balls of known radii rotated through known angles Radius of ball 6-74 6'74 6'74 7,14 7.I4 7-52 7T52 752 8-35 8.33 8.33 8.73 8.73 8-73 9-9- 9- True radius of movement 11.35 I2.35 13-35 11.74 I2.74 13.74 II-99 I2'99 13.99 I2-I4 I2*52 I3-52 I4.52 I2-92 I3.92 I4.92 I3. I4. I5- I3.33 14.33 15.33 I3.73 14.73 I5-73 I4. I5- I6-oo Mean error -oix, SD oi i, SE -213 Measured radius II.49 I2-59 I3*I II.7I I2-84 I3.82 II-9I I2-83 I3.8 I2-I6 I3.7 I4-5 I2.4 I3.53 I4.47 I2-6 I3-66 14.49 I2-89 13.8 I4.8I 13.23 14.25 I5-32 13.59 14.62 I5-6 13.89 14.8 I5.79 Difference +ri4 +±I4 --25 --3 +OIO +o-o8 -o-o8 --2 --7 -o og.512 +-1 --5 --32 --26 --36 -O-II --2 -O-I9 -o-o8-131 --14I -'2 -'21I Fig. 3 shows the refraction of all eyes plotted against their axial length. There is an obvious correlation, and computer analysis gave a correlation coefficient for all eyes of -o-8592. The regression line for axial length on refraction was R= -2z578 A + 66-658, where R=refraction in dioptres and A = axial length in millimetres. The correlation for female eyes alone (Fig. 4) was -o767 and for male eyes (Fig. 5) -o-8925. If eyes with refractions between + 2zoo D and -i oo D were excluded the correlation coefficient was -o-8739. There was also a correlation between corneal radius and refraction (-o2i2 for all eyes) (Table II). Discussion The axial length of eyes with low refractive errors as measured by this method is about three milli-

Determining the axial length of the eye 269 +21 Table II Correlation coefficients I. +1- *. 4 * * eso o o%w,6 &so -1- i4 ooo Female Male All Coefficients between eyes eyes eyes Refraction and axial length -o767 -o8925 -o8592 Refraction and corneal radius -O-II35 -'2555 -'212-2- metres greater than that obtained by x-ray or O ultrasonic techniques. The latter techniques measure the distance between the anterior surface of -3, I the cornea and the retina, whereas the present 2 22 24 26 28 3 32 34 method includes the thickness of the choroid mm and sclera. According to Duke-Elder and Wybar FIG. 3 Measurements of axial length plotted (I97) the choroid is -2--3 mm thick and the against refractive error in 8o eyes sclera I-I 3 mm thick at the posterior pole, so our measurements would be expected to be about I5 mm too great. This still leaves I5 mm to be +2 accounted for. The calculation of axial length assumes that the apex of the cornea coincides with the circumference of the globe. If, however, +1- this assumption is incorrect and the cornea is a * segment of a sphere protruding from the globe the * r@. * axial length as calculated would be overestimated - O - * by the corneal protrusion. Assuming a corneal radius of 7.5 mm, a corneal diameter of I2 mm, *^ and a radius of curvature of the globe of I2 mm -1- it can be calculated that the distance from the centre of rotation of the globe to the apex of the cornea is I43 mm greater than the radius of curva- -2- ture of the sclera. Park and Park (I933) found the centre of rotation of the globe to be about I3'8 mm posterior to the -3 2 2 2 2 3 3 apex of the cornea, which is similar to the mean mm 22 24 26 28 3 32 value in male emmetropic eyes in our series. This adds support to the suggestion that the apex of the FIG. 4 Measurements of axial length plotted against cornea does not lie on the circumference of the refractive error in 37 female eyes globe but protrudes beyond it. The correlation between the axial length, as measured by the present method, and the refraction +1- o is similar to that obtained by Stenstrom (I948) % by ultrasonography, and suggests that even if we % -. : are not measuring the true axial length of the eye o the dimension measured is so closely related to the oo axial length that it is valid for clinical purposes. -1 * The slope of the regression line for axial length/ refraction is such that a change of refraction of -2-oIoo D is equivalent to a o39 mm change in axial length. -3 Some idea of the consistency of the readings 2 22 24 26 28 3 32 34 38 may be obtained by comparing the paired readings of corneal radius and axial length made on each eye. FIG. 5 Measurements of axial length plotted against The two measurements of corneal radius were refractive error in 43 male eyes identical in 52 of the 8o eyes, and differed by oo5

27 British Journal of Ophthalmology mm in 13 and oio mm in I2 eyes. As would be expected, the differences between the paired readings of axial length were greater; the measurements were identical in I3 eyes but differed by over i mm in eight eyes. Four of these eyes were highly myopic with poor fixation and two were highly hypermetropic, also with poor fixation. The mean difference between paired readings for 8o eyes was o43 mm. In spite of the theoretical objections to this photographic method the excellent correlation between the measurements and refraction suggests that the method is a useful alternative to ultrasonography. In addition it is quick to do, comfort- References able for the patient, and does not demand expensive apparatus. Summary By photographing the corneal reflex in two positions of gaze and measuring the radius of curvature of the cornea it is possible to calculate the radius of rotation of the eye. The measurements obtained in this way showed a high correlation with refraction in a series of 8o eyes. The axial length obtained by this method was about 3 mnm greater than that obtained by ultrasonographic or x-ray methods, and the reasons for the discrepancy are discussed. DUKE-ELDER, S., and WYBAR, K. C. (197) The anatomy of the visual system, in 'System of Ophthalmology', vol. 2, ed. Sir Stewart Duke-Elder. Kimpton, London, and ABRAMS, D. (I97) Ophthalmic optics and refraction, in 'System of Ophthalmology', vol. 5. ed Sir Stewart Duke-Elder. Kimpton, London PARK, R. S., and PARK, G. E. (1933) Amer. J7. Physiol., 14, 545 RUSHTON, R. H. (1938) Trans. ophthal. Soc. U.K., 58, 136 SORSBY, A., and O'CONNOR, A. D. (1945) Nature (Lond.), I56, 779 STENSTROM, S. (1948) Variations and correlations of the optical components of the eye, in 'Modern Trends in Ophthalmology', vol. 2, p. 87, ed A. Sorsby. Butterworth, London Br J Ophthalmol: first published as 1.1136/bjo.6.4.266 on 1 April 1976. Downloaded from http://bjo.bmj.com/ on 19 June 218 by guest. Protected by copyright.