Reyrolle Protection Devices. 7PG18 - TR-A High speed tripping Relay. Energy Management.

Similar documents
7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

6RZ. > <8ms and <30ms performance versions > Single and dual element versions > Draw out case > Flush panel or rack mount > Made in Australia

Reyrolle Protection Devices. 7PG11-18 Alpha Electromechanical Relays. Siemens. Answers for energy.

ASHIDA Numerical OC/EF Protection Relay

Type VAEM 22 Negative Potential Biasing Relay

7PG21 Solkor Rf Feeder Protection Energy Management

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

7PG23 5B3 Restricted Earth Fault Answers for energy

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Harmonic restraint earth fault or single-phase overcurrent protection

Reyrolle Protection Devices. 7SG14 Duobias M Transformer Protection. Answers for energy

Data Sheet. RISH Master Record %THD

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Instantaneous Overcurrent Relay

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Type CAEM 21 Battery Earth Fault Relay

05/09/2012

Overcurrent Protection / 7SJ45

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Mors Smitt Industrial Technology. High performance plug-in relays

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

27/04/2015

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

RE17LLBM asymmetrical flashing relay s V AC - solid state output

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Digital Multifunction Instrument - Rish Master 3440

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Time over/underfrequency relay with protection assemblies

1 T max. T min. = ± 100 (%) time. time T = T 1 + T 2 T 3 T 1. T: Final time-up time T 1 : Time elapsed T 2 : New setting T 3 : Previous setting

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Multimeter 500CVD21 RTU500 series

4 Series Screened. 3.5kV, 3.5A

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

XUA1 - AC Voltage and phase balance relay

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

MINIATURE SIGNAL RELAYS

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Type VDG 13 Undervoltage Relay

SPECIFICATION, CONTROLS AND ACCESSORIES

48 Series - Relay interface modules A. Features

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Transformer differential protection

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

RE11RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

ASHIDA Numerical 3OC + 1EF Protection Relay

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

SWT 3000 Teleprotection technical data siemens.com

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C

Chip Varistor LVS B DESCRIPTION APPLICATIONS FEATURES ORDERING INFORMATION. Capacitance 030 = 3pF 300 = 30pF 301 = 300pF

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

AUXILIARY RELAYS FOR TRIPPING APPLICATIONS

Relay Types. Reed V23100-V4 Relay. Typical applications. Features. DIP version (flat) DIP version (high) SIL version.

Technical Information General Purpose Relays

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

AC/DC to Logic Interface Optocouplers Technical Data

Suitable for lighting and motor load, 1 Form A 50A latching relays

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

HIGH SENSIBILITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

08/07/2015

38 Series - Relay interface modules A. Features /

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

PRODUCT TEST MANUAL 2SY110K28 SYNCHRONISM CHECK RELAY

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

02/11/2015

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Transcription:

Reyrolle Protection Devices 7PG18 - A High speed tripping Relay Energy Management.

7PG18 A High speed tripping relay Features High speed, positive action Can be supplied in modular and drawout type case Robust design for a long, reliable, service life Description Type A relays are a range of volt age operated multicontact attracted armature relays designed to both IEC 255-5 and to BS142. A wide range of models is available to meet the requirements of the electric supply industry. A2 High burden to ESI 48-4 EB2 & NGTS 3.6.15, ESI 2. Table 1 shows the standard relays available. High burden, A2 series High burden relays with immunity to capacitance discharge currents. They are also suitable for certain applications where they are remote from the initiation signal. A high burden also permits reliable operation of current operated series repeat relays. TR relays can be provided with a time delayed economy feature, either instantaneous or time delayed, see Table1. Technical Information A2 series relays Operating time 10ms at rated voltage Rated voltage Vn 24V, 30V, 48V, 125V, 240Vd.c Note. 24V and 240V ratings are not part of ESI 48-4 Operating range 50% to 120% of rated voltage Nominal burdens Rated Voltage V.d.c TR2-30 43 48 52 125 <150 Reset coil 50 Relays with economy circuits reduce to approximately 14W Type Spec Burden A212 A214 A221 A223 A231 A233 A241 20 Self Economy 2s delay 20 Hand Instantaneous 20 Hand 40/60ms delay 20 Electricataneous Instan- 20 Electrical 40/60ms delay 20 Hand Instantaneous and Electrical A243 Table 1 Ratings Contact Reset No. of contacts Operating coil cut-off 20 Self Economy 20 Hand and Electrical 40/60ms delay Ca se siz e Make and carry continuously: 1250VAa.c. or 1250Wd.c. within limits of 660V and 5A Make and carry for 3 seconds: 7500VAa.c. or 7500Wd.c. within limits of 660V and 30A Break; 1250VAa.c. or 100W (resistive) d.c. or 50W (inductive) d.c. within limits of 250V and 5A Maximum rate of operation, 600 per hour Indication A2 relays have a hand reset mechanical flag indicator Operating coils of self-reset and economy cut-off relays are rated at 120% of rated voltage. All other operate and reset coils are short time rated well in excess of the operating time of their cut-off contacts. Self-reset relays will reset at not less than 5% rated voltage. Siemens Protection Devices Limited 2

Environmental Temperature IEC68-2-1/2 and BS2011 (1977) Operating -10 C to +55 C Storage -25 C to +70 C Humidity IEC 68-2-3 56 days at 95% RH and 40 C Vibration IEC 255-21-1 Class l. Shock and bump IEC 255-21-2 and BS142, 1.5.2 (1989). Relays meet the requirements with respect to shock and bump testing for Class 1 severity. Operational/mechanical life Relays will withstand in excess of 10,000 operations, within the maximum contact loading specified, at a rate of 600 operations per hour. Insulation Relays will withstand: 5kV 1.2/50µs waveform as IEC 255-4 2kV rms 50Hz for 1minute (2.5kV for 1s) between all terminals and earth 1kV rms 50Hz for 1 minute across normally open contacts to IEC 255-5 and BS142 Siemens Protection Devices Limited 3

Ordering Information 7PG18 Product description Variants Order No. Tripping relay 7 P G 1 8 2 1-2 8 0-1 c 0 EPSILON A212, A214 (20 CONTACT) Alpha range 5 A Tripping 8 A Tripping 6 A2-- : high burden, EB2 2 Contact operation 7 Self reset contacts 1 Operating coil cut-off 8 Economy 2 Economy and 2 second delay on reset 4 Contact arrangement - NO 9 0 NO A W 1 NO B V 2 NO C U 3 NO D T 4 NO E S 5 NO F R 6 NO G Q 7 NO H P 8 NO J N 9 NO K M 10 NO L L 11 NO M K 12 NO N J 13 NO P H 14 NO Q G 15 NO R F 16 NO S E 17 NO T D 18 NO U C 19 NO V B 20 NO W A Contact arrangement NC 10 0 NC A 1 NC B 2 NC C 3 NC D 4 NC E 5 NC F 6 NC G 7 NC H 8 NC J 9 NC K 10 NC L 11 NC M 12 NC N 13 NC P 14 NC Q 15 NC R (Continued on following page) Siemens Protection Devices Limited 4

Product description Variants Order No. Tripping relay 8 0-1 C 0 EPSILON 16 NC S A212, A214 (20 CONTACT) 17 NC T 18 NC U 19 NC V 20 NC W Number of contacts 11 Twenty 8 Contact type 12 NO (Standard) / NC (Standard) 0 Type of flag 13 Hand reset flag 1 Housing size 14 Case size E4 (4U high) C Voltage Rating 15 24V dc B 30V dc C 50V dc D 125V dc F 240V dc H Back emf suppression diode 16 Not Fitted 0 Siemens Protection Devices Limited 5

Ordering Information 7PG18 Product description Variants Order No. Tripping relay 7 P G 1 8 2 2-1 8 0-1 C 0 EPSILON A221 (20 CONTACT) Alpha range 5 A Tripping 8 A Tripping 6 A2-- : high burden, EB2 2 Contact operation 7 Hand reset contacts 2 Operating coil cut-off 8 Instantaneous 1 Contact arrangement - NO 9 0 NO A W 1 NO B V 2 NO C U 3 NO D T 4 NO E S 5 NO F R 6 NO G Q 7 NO H P 8 NO J N 9 NO K M 10 NO L L 11 NO M K 12 NO N J 13 NO P H 14 NO Q G 15 NO R F 16 NO S E 17 NO T D 18 NO U C 19 NO V B 20 NO W A Contact arrangement NC 10 0 NC A 1 NC B 2 NC C 3 NC D 4 NC E 5 NC F 6 NC G 7 NC H 8 NC J 9 NC K 10 NC L 11 NC M 12 NC N 13 NC P 14 NC Q 15 NC R (Continued on following page) Siemens Protection Devices Limited 6

Product description Variants Order No. Tripping relay 8 0-1 C 0 EPSILON A221 (20 CONTACT) 16 NC S 17 NC T 18 NC U 19 NC V 20 NC W Number of contacts 11 Twenty 8 Contact type 12 NO (Standard) / NC (Standard) 0 Type of flag 13 Hand reset flag 1 Housing size 14 Case size E4 (4U high) C Voltage Rating 15 24V dc B 30V dc C 50V dc D 125V dc F 240V dc H Back emf suppression diode 16 Not Fitted 0 Siemens Protection Devices Limited 7

Ordering Information 7PG18 Product description Variants Order No. Tripping relay 7 P G 1 8 2 3-1 8 0-1 C 0 EPSILON A231 (20 CONTACT) Alpha range 5 A Tripping 8 A Tripping 6 A2-- : high burden, EB2 2 Contact operation 7 Electrical reset contacts 3 Operating coil cut-off 8 Instantaneous 1 Contact arrangement - NO 9 0 NO A W 1 NO B V 2 NO C U 3 NO D T 4 NO E S 5 NO F R 6 NO G Q 7 NO H P 8 NO J N 9 NO K M 10 NO L L 11 NO M K 12 NO N J 13 NO P H 14 NO Q G 15 NO R F 16 NO S E 17 NO T D 18 NO U C 19 NO V B 20 NO W A Contact arrangement NC 10 0 NC A 1 NC B 2 NC C 3 NC D 4 NC E 5 NC F 6 NC G 7 NC H 8 NC J 9 NC K 10 NC L 11 NC M 12 NC N 13 NC P 14 NC Q 15 NC R (Continued on following page) Siemens Protection Devices Limited 8

Product description Variants Order No. Tripping relay 8 0-1 C 0 EPSILON A231 (20 CONTACT) 16 NC S 17 NC T 18 NC U 19 NC V 20 NC W Number of contacts 11 Twenty 8 Contact type 12 NO (Standard) / NC (Standard) 0 Type of flag 13 Hand reset flag 1 Housing size 14 Case size E4 (4U high) C Voltage Rating 15 24V dc B 30V dc C 50V dc D 125V dc F 240V dc H Back emf suppression diode 16 Not Fitted 0 Siemens Protection Devices Limited 9

Ordering Information 7PG18 Product description Variants Order No. Tripping relay 7 P G 1 8 2 4-1 8 0-1 C 0 EPSILON A241 (20 CONTACT) Alpha range 5 A Tripping 8 A Tripping 6 A2-- : high burden, EB2 2 Contact operation 7 Hand and electrical reset contacts 4 Operating coil cut-off 8 Instantaneous 1 Contact arrangement - NO 9 0 NO A W 1 NO B V 2 NO C U 3 NO D T 4 NO E S 5 NO F R 6 NO G Q 7 NO H P 8 NO J N 9 NO K M 10 NO L L 11 NO M K 12 NO N J 13 NO P H 14 NO Q G 15 NO R F 16 NO S E 17 NO T D 18 NO U C 19 NO V B 20 NO W A Contact arrangement NC 10 0 NC A 1 NC B 2 NC C 3 NC D 4 NC E 5 NC F 6 NC G 7 NC H 8 NC J 9 NC K 10 NC L 11 NC M 12 NC N 13 NC P 14 NC Q 15 NC R (Continued on following page) Siemens Protection Devices Limited 10

Product description Variants Order No. Tripping relay 8 0-1 C 0 EPSILON A241 (20 CONTACT) 16 NC S 17 NC T 18 NC U 19 NC V 20 NC W Number of contacts 11 Twenty 8 Contact type 12 NO (Standard) / NC (Standard) 0 Type of flag 13 Hand reset flag 1 Housing size 14 Case size E4 (4U high) C Voltage Rating 15 24V dc B 30V dc C 50V dc D 125V dc F 240V dc H Back emf suppression diode 16 Not Fitted 0 Siemens Protection Devices Limited 11

Siemens Protection Devices Limited P.O. Box 8 North Farm Road Hebburn Tyne & Wear NE31 1TZ United Kingdom Phone: +44 (0)191 401 7901 Fax: +44 (0)191 401 5575 E-mail: marketing.spdl.gb@siemens.com EMDG-C10081-00-76GB December 2012 For enquires please contact our Customer Support Centre Phone: +49 180/524 8437 (24hrs) Fax: +49 180/524 24 71 E-mail: support.energy@siemens.com www.siemens.com/protection Subject to change without notice,. Printed in the UK. www. siemens.com/reyrolle Siemens Protection Devices Limited 12