Level Measurement. Applications. Special features. Description

Similar documents
Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design

Field indicator for current loops with HART communication Models DIH50, DIH52

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital indicator for panel mounting With multi-function input Model DI25

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Submersible pressure sensor For superior applications Model LF-1

Analogue Temperature Transmitter

Field indicator for current loops with HART communication Models DIH50, DIH52

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Isolating Repeater Input Series 9163

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. Power Rail

HART field temperature transmitter Models TIF50, TIF52, TIF62

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Isolators A3/1.

Weighing Instruments

Inductive sensor slot-type SI2-K08-AP7

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

CONTA-ELECTRONICS. Converter Units

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Binary Output without Power Supply Series 9176

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Isolators A3/1. Vibration Transducer Supply Unit Series

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Resistance thermometer Model TR30, compact design

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

P5201 Universal Programmable Transmitters with Galvanic Isolation

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Remote I/O. 74 Remote I/O. Remote I/O System

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

SALES SERVICE +358 (0)

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

In-Line Resistance Thermometers Model TR25

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Trip amplifier, 1 channel

Certificate of Compliance

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Binary Output Series 9175

Design and applications

Resistance Thermometers Model Series TR7X0, Sheathed Design

Electronic temperature switch with display Model TSD-30

Temperature Input Module for Zone 1 Series 9482/32

Resistance thermometer Model TR31, miniature design

itemp PA TMT184 Technical information

Operating Instructions

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Electrical Alarm Contacts

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Indicator for panel mounting Model

Electrical Alarm Contacts

Assembly. Front view. Parametrization interface. Power Bus

Control Units, Head-mounted transmitter Set Point Relays Typ GW24, Contact Protection Relays

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

5 years! Modular Housings. VariTrans P Warranty

R88000 T (including ATEX)

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

RMA42. Technical Information

Analog Universal Module HART for Zone 2 Series 9468/33

Temperature transmitter itemp PCP DIN rail TMT 121

OEM pressure transmitter For mobile working machines Model MH-3

Assembly. Front view. Switch Power Rail

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

PEM353. Universal measuring device

MINI MCR-SL-UI-I-LP-NC

Transcription:

Level Measurement Transmitters, Head-mounted Transmitters Set Point Relays, Contact Protection Relays For the conversion of sensor signals to current signals and protection of contacts against overload ELM KSR KUEBLER AG Datasheet ELM Applications Conversion of sensor signals into voltage or current signals Protection of contacts against overload Special features Explosion protection optional Description Transmitters convert a resistance input into a proportional analogue respectively digital output., output and power supply are isolated from each other. Transmitters are especially for use with KSR level sensors. The set point relays monitor trip limits in measurements using current/voltage signals. These signals can be generated by transmitters. Set point relays can be configured using DIP switches and potentiometers. Contact protection relays are used to switch higher currents. A binary switch connected to the control circuit on the input triggers the relay with a higher contact rating. This increases service life considerably. The output relay is voltage-free. s are safely separated from outputs and supply voltage. Contact protection relays are Temperaturee stabilised and guarantee reliable switching operation. KSR Datasheet ELM 03/2017 Page 1

Overviews Transmitter, Rail-mounted T15.R Page 5 T15.R-AI Page 5 KFD2-PT2-1 Page 6 Cabinet DIN rail DC 8 V... 35 V DC 30 V DC 20 V... 35 V 1 kohm 50 kohm KFD2-PT2-Ex1-. Page 6 1 kohm... 250 kohm 4 ma... 20mA 0 ma... 20 ma, 0 V 10 V, 2 V 10 V Temperature -40 C +85 C -20 C +60 C Ex approval Ex ia IIC Ex ia IIC 17.5 mm x 99 mm x 113.6 mm 20 mm x 92.5 mm x 115 mm additional features T32.3S.000 Page 7 T32.3S.01S Page 7 DDN45E Page 8 Tracker 22.-.- Page 9 Cabinet DIN rail Panel DC 10.5 V 42 V DC 10.5 V... 30 V DC 24 V AC 24 / 115 / 230 V 10 kohm 100 kohm 1 kohm 100 kohm AC/DC 10 V... 32 V AC 90 V... 265 V 400 Ohm 100 kohm 4 ma... 20mA 0 ma... 20 ma, 4 ma... 20 ma 0 V 10 V, 2 V 10 V Temperature -40 C +85 C -0 C +50 C 10 C +50 C Ex approval Ex ia IIC 17.5 mm x 99 mm x 113.6 mm 45 mm x 75 mm x 100 mm additional features HART Communication LED display 2 Switch points 96 mm x 48 mm x 173 mm LED display 2 Switch points (optional) KSR Datasheet ELM 03/2017 Page 2

Overviews Transmitter, Head-mounted T15.H Page 10 T15.H-AI Page 10 T32.1S.000 Page 11 Head-mounted T32.1S.01S Page 11 DC 8 V... 35 V DC 30 V DC 10.5 V 42 V DC 10.5 V... 30 V 1 kohm 50 kohm 10 kohm 100 kohm 4 ma... 20mA 4 ma... 20mA Temperature -40 C +85 C -40 C +85 C Ex approval Ex ia IIC Ex ia IIC OD 44 mm H 22.5 mm OD 49.5 mm H 28.5 mm additional features HART Communication T53.10.01S Page 12 DC 8 V... 32 V AC 8 V... 28 V 1 kohm 100 kohm TS Page 13 TE Page 13 Head-mounted DC 11 V 30 V 1 kohm 100 kohm TLH Page 14 TLEH Page 14 DC 11 V 30 V 1 kohm 100 kohm 4 ma... 20mA 4 ma... 20mA 4 ma... 20mA Temperature -40 C +85 C -20 C +65 C -20 C +130 C -20 C +65 C -20 C +130 C Ex approval Ex ia IIC Ex ia IIC OD 44 mm H 25 mm OD 44 mm H 20 mm OD 60 mm H 28 mm additional features PROFIBUS FOUNDATION Fieldbus LCD display KSR Datasheet ELM 03/2017 Page 3

Overviews Set point relay, Power supply unit, Rail-mounted Set point relay KFD2-GS-1.2W Page 15 Cabinet DIN rail Power supply unit PSLC Page 16 DC 20 V 30 V AC 230 / 115 V 45 Hz... 66 Hz 0 ma... 20 ma, 4 ma 50 Ohm 0 V 10 V, 2 V 10 V 100 kohm 0 ma... 20 ma, 4 ma 400 Ohm 0 V 10 V, 2 V 10 V 500 Ohm 115 V max. 330 ma 230 V max. 165 ma 24 VDC 1.5 A Temperature 0 C +50 C -30 C +80 C Ex approval 20 mm x 124 mm x 150 mm 55 mm x 75 mm x 110 mm additional features Overviews Contact protection relay, Rail-mounted KFA6-ER-1.6 Page 17 KFD2-ER-1.6 Page 17 Cabinet DIN rail KFA6-SR2-Ex2.W Page 18 AC 207 V... 253 V, 45 Hz... 65 Hz AC 207 V... 253 V, 45... 65 Hz Max. AC 10 V (approx. 1 Hz) Max 5 ma 253 V AC / 2 A 40 V DC / 2 A DC 8 V 8 ma Temperature -20 C +60 C -20 C +60 C Ex approval Ex ia IIC KFD2-SR2-Ex2.W Page 18 DC 20 V 30 V 20 mm x 107 mm x 115 mm 20 mm x 119 mm x 115 mm additional features KSR Datasheet ELM 03/2017 Page 4

Transmitter T15.R, Rail-mounted Analogue Technical details T15.R T15.R-AI Supply voltage Power consumption DC 8 V... 35 V resistance 1 kohm 50 kohm Max values acc. to Declaration of conformity Approval number Group, category, ignition protection type Max. Voltage U 0 Max. Current I 0 Max. Power P 0 s 4 ma... 20 ma Galvanic Isolation Mains/ - Mains Operating temperature Connection terminal DC 30 V ia 800 mw ic 750 mw BVS 15 ATEX E 139 X II 1G Ex ia IIC II 1D Ex ia IIIC DC 30 V 6.1 ma 46 W -40 C +85 C -40 C +85 C (T4) -40 C +70 C (T5) -40 C +55 C (T6) IP 20 Terminal case in plastic W x H x D 17.5 mm x 99 mm x 113.6 mm Suitable for all rails to IEC 60715 Screw terminal 0.14... 2.5 mm² approx. 200g KSR Datasheet ELM 03/2017 Page 5

Transmitter KFD2-PT2-, Rail-mounted Analogue Technical details KFD2-PT2-1 KFD2-PT2-Ex1-. Max values acc. to Declaration of conformity Galvanic Isolation Supply voltage Power consumption resistance Measuring voltage Approval number Group, category, ignition protection type Max. Voltage U 0 Max. Current I 0 Max. Power P 0 s Max. Load (Current) resistance (Voltage) Mains/ - Mains Operating temperature Connection terminal DC 20 V... 35 V approx. 0.6 W with voltage output approx. 1.3 W with current output 1 kohm... 250 kohm Approx. 4,7V measured at 0 ma... 20 ma, 0 V 10 V, 2 V 10 V 1000 Ohm 30 Ohm -20 C +60 C IP 20 35 mm DIN rail to EN 60715:2001 W x H x D 20 mm x 92.5 mm x 115 mm Screw terminal, max. 2.5 mm² approx. 120g BAS 00 ATEX 7171 II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I 10,4 V DC 31,4 ma 82 W KSR Datasheet ELM 03/2017 Page 6

Transmitter T32.3S, Rail-mounted HART Protocol Technical details T32.3S.000 T32.3S.01S Supply voltage DC 10.5 V... 42 V DC 10.5 V... 30 V resistance 10 kohm 100 kohm Max values acc. to Declaration of conformity Approval number Group, category, ignition protection type Max. Voltage U 0 Max. Current I 0 Max. Power P 0 BVS 08 ATEX E 019 X II 1G Ex ia IIC II 1D Ex iad 20 6.5 V DC 9.3 ma 15,2 mw s 4 ma... 20 ma Galvanic Isolation Mains/ - Mains Operating temperature Connection terminal -40 C +85 C -40 C +85 C (T4) -40 C +75 C (T5) -40 C +60 C (T6) IP 20 Terminal case in plastic W x H x D 17.5 mm x 99 mm x 113.6 mm Suitable for all rails to IEC 60715 Screw terminal 0.14... 2.5 mm² approx. 200g KSR Datasheet ELM 03/2017 Page 7

Transmitter DDN45E, Rail-mounted LED display, 2 Switch points Technical details Supply voltage Power consumption DDN45E Optional AC 24 V / DC 24 V AC 115 / 230 V approx. 4 VA resistance 1 kohm 100 kohm Display Attention! Current max. Load Voltage resistance Operating temperature Storage temperature 0 ma... 20 ma, 4 ma... 20 ma 400 Ohm 0 V 10 V, 2 V 10 V 500 Ohm 4 digit Display 7- Segment LED 0 C +50 C -30 C +70 C Casing IP 40 Terminals IP 20 Casing ABS, Fire protection classe UL94 HB / 1.6 W x H x D 45 mm x 75 mm x 100 mm 35 mm DIN rail or mounting with 2 screws approx. 320g Use shielded circuit only (EMC) KSR Datasheet ELM 03/2017 Page 8

Transmitter Tracker 22.-.-R, Panel mounting LED display, 2 Switch points programmable (optional) Technical details Relai output Display Programming Isolation Attention! Supply voltage Power consumption Voltage Current Resistance Current Voltage Resolution Max. Load Hysteresis Contact rating Operating temperature Connection terminal Tracker 221-.-R Tracker 223-.-R See type code approx. 10 VA 400 Ohm 100 kohm ± 100 mv, ± 10 V ± 20 ma 0 Ohm 400 Ohm 0 ma... 20 ma, 4 ma... 20mA 0 V 10 V, 2 V 10 V 0.05 %, 5 mv or 0.01 ma 900 Ohm Tracker 222-.-R free programmable programmable AC 1 A / 250 V 4 digit 5 digit 4 digit 7- Segment LED 7- Segment LED 7- Segment LED Display and output programmable with up to 24 values tested to 500 V 10 C +50 C IP 20 Casing for panel mounting W x H x D 96 mm x 48 mm x 173 mm Field casing IP 65 available Self-opening terminals with max. 2.5 mm² approx. 400g Use shielded circuit only (EMC) Tracker 224-.-R 5 digit 7- Segment LED code Tracker -.- R 1 = Supply voltage AC 90 V... 265 V 2 = Supply voltage AC/DC 10 V... 32 V 221 = Display only 222 = Display and output relays 223 = Display and current output 224 = Display, current output und output relays Tracker = Base e KSR Datasheet ELM 03/2017 Page 9

Transmitter T15.H, Head-mounted Analogue Technical details T15.H T15.H-AI Supply voltage Power consumption DC 8 V... 35 V resistance 1 kohm 50 kohm Max values acc. to Declaration of conformity Approval number Group, category, ignition protection class Max. Voltage U 0 Max. Current I 0 Max. Power P 0 s 4 ma... 20 ma Galvanic Isolation Mains/ - Mains DC 30 V ia 800 mw ic 750 mw BVS 15 ATEX E 139 X II 1G Ex ia IIC II 1D Ex ia IIIC DC 30 V 6.1 ma 46 W Operating temperature -40 C +85 C) -40 C +85 C (T4) -40 C +70 C (T5) -40 C +55 C (T6) Connection terminal Terminal case in plastic OD 44 mm H 22.5 mm Screw terminal 0.14... 2.5 mm² approx. 200g KSR Datasheet ELM 03/2017 Page 10

Transmitter T32.1S, Head-mounted HART Protocol Technical details T32.1S.000 T32.1S.01S Supply voltage DC 10.5 V... 42 V DC 10.5 V... 30 V resistance 10 kohm 100 kohm Max values acc. to Declaration of conformity Approval number Group, category, ignition protection type Max. Voltage U 0 Max. Current I 0 Max. Power P 0 BVS 08 ATEX E 019 X II 1G Ex ia IIC II 1D Ex iad 20 6.5 V DC 9.3 ma 15,2 mw s 4 ma... 20 ma Galvanic Isolation Mains/ - Mains Operating temperature -40 C +85 C -40 C +85 C (T4) -40 C +75 C (T5) -40 C +60 C (T6) Connection terminal Terminal case in PBT, glass-fibre reinforced OD 49.5 mm H 28.5 mm Screw terminal 0.14... 2.5 mm² approx. 70g KSR Datasheet ELM 03/2017 Page 11

Transmitter T53.10, Head-mounted Profibus, Foundation Fieldbus Technical details T53.10.0IS Supply voltage DC 8 V... 32 V AC 8 V... 28 V resistance 1 kohm 100 kohm Max values acc. to Declaration of conformity Approval number Group, category, ignition protection type Max. Voltage U 0 Max. Current I 0 Max. Power P 0 KEMA 06 ATEX 0148 See WIKA Datasheet TE 53.01 s FOUNDATION Fieldbus PROFIBUS Galvanic Isolation Mains/ - Mains Operating temperature See WIKA Datasheet TE 53.01 Connection terminal Terminal case in PBT, glass-fibre reinforced OD 44 mm H 25 mm Screw terminal 0.14 1.5 mm² approx. 50g KSR Datasheet ELM 03/2017 Page 12

Transmitter TS / TE, Head-mounted Analogue Technical details TS TE Supply voltage DC 11 V 30 V resistance 1 kohm 100 kohm Approval Current Max. Load Zero point setting Measuring range setting Accuracy 4 ma 20 ma 1000 Ohm U B DC 30 V 700 Ohm U B DC 24 V 50 Ohm U B 12 V DC ± 5 % 75 % 100 % 0.15 % Ex ia IIC U i < 30 V I i < 101 ma P i < 758 mw Or U i < 28,4 V I i < 116 ma P i < 824 mw LCIE 05 ATEX 6006 X II 1G Ex ia IIC T6 T4 Attention! Ambient temperature -20 C +60 C max. 80 C (T6) max. 95 C (T5) max. 130 C (T4) IP 20 Potted OD 44 mm H 20 mm Head-mounted approx. 40 g Use shielded circuit only (EMC) KSR Datasheet ELM 03/2017 Page 13

Transmitter TLH / TLEH, Head-mounted Analogue Technical details TLH TLEH Supply voltage DC 11 V 30 V resistance 1 kohm 100 kohm Approval Current Max. Load Zero point setting Measuring range setting Accuracy 4 ma 20 ma 1000 Ohm U B DC 30 V 700 Ohm U B DC 24 V 50 Ohm U B 12 V DC ± 5 % 75 % 100 % 015 % Ex ia IIC U i < 30 V I i < 101 ma P i < 758 mw Or U i < 28,4 V I i < 116 ma P i < 824 mw LCIE 05 ATEX 6006 X II 1G Ex ia IIC T6 T4 Ambient temperature -20 C +60 C -20 C +60 C (T6 T4) Attention! IP 20 Potted OD 60 mm H 28 mm Head-mounted approx. 70 g Use shielded circuit only (EMC) KSR Datasheet ELM 03/2017 Page 14

Set point relay KFD2-GS-1.2W, Rail-mounted Analogue Technical details Supply voltage Power consumption Current input resistance Voltage input resistance KFD2-GS-1.2W DC 20 V... 30 V approx. 2,25 W 0 ma... 20 ma, 4 ma... 20 ma 50 Ohm 0 V 10 V, 2 V 10 V 100 kohm Contact rating 0 ma... 20 ma, 4 ma... 20 ma 400 Ohm 0 V 10 V, 2 V 10 V 500 Ohm Display Attention! Operating temperature Storage temperature 4 digit Display 7- Segment LED 0 C +50 C -30 C +70 C Casing IP 40 Terminals IP 20 Casing ABS, Fire protection class UL94 HB / 1.6 W x H x D 20 mm x 124 mm x 150 mm 35 mm DIN rail or mounting with 2 screws approx. 320g Use shielded circuit only (EMC) KSR Datasheet ELM 03/2017 Page 15

Power supply unit PSLC 242, Rail-mounted Technical details PSLC 242 Protection Supply voltage Frequency current Voltage Current Fuse input protection Overload protection MTBF Operating temperature Storage temperature AC 230 / 115 V 45 Hz... 66 Hz 115 V max. 330 ma 230 V max. 165 ma DC 24 V 1.5 A 115 V AC 500 ma / 230 V AC 250 ma Short circuit protected Integrated > 400.000 h -30 C +80-30 C +105 C Casing IP 60 Terminals IP 20 W x H x D 55 mm x 75 mm x 110 mm DIN rail DIN 46277 or wall mounting approx. 840g KSR Datasheet ELM 03/2017 Page 16

Contact Protection Relay KF..-ER-1.6, Rail-mounted Analogue Technical details KFA6-ER-1.6 KFD2-ER-1.6 Supply voltage AC 207 V... 253 V, 45 Hz... 65 Hz DC 20 30 V Galvanic Isolation Power consumption Max. Voltage Max. Current Contact rating AC Contact rating DC Reaction time Mains - Mains - Operating temperature Connection terminal 0,8 W 10 V AC (approx. 1 Hz) 5 ma 253 V AC / 2 A / cosɸ > 7 40 V DC / 2 A approx. 1 s Safe Galvanic Isolation to DIN 106 Rated insulation voltage 253 V eff -20 C +60 C IP 20 35 mm DIN rail to EN 60715:2001 W x H x D 20 mm x 107 mm x 115 mm Screw terminal, max. 2.5 mm² approx. 110g KSR Datasheet ELM 03/2017 Page 17

Contact protection relay KF..-SR2-Ex2.W, Rail-mounted Analogue Technical details KFA6-SR2-Ex2.W KFD2-SR2-Ex2.W Supply voltage Power consumption Safety related maximum voltage AC 207 V... 253 V, 45... 65 Hz 1.3 W 253 V AC DC 20 V 30 V 1.3 W 125 V DC, 253 V AC Open circuit voltage Short circuit current Switch point Switching hysteresis Wire-break monitor approx. 8 V DC approx. 8 ma 1,2 ma... 2.1 ma approx. 0,2 ma Break I 0.1 ma, short circuit I > 6mA Max values acc. to Declaration of conformity and approval certificate Approval number Group, category, ignition protection type Max. Voltage UO Max. Current IO Max. Power PO PTR 00 ATEX 2081 II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I 10.6 V 19.1 ma 51 mw PTR 00 ATEX 2080 II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I 10.5 V 13 ma 34 mw Contact rating AC Contact rating DC Mechanical lifetime 253 V / 2 A / cosɸ > 0,7 40 V / 2 A/ resistive load 10 7 cycles Operating temperature -20 C +60 C IP 20 Connection terminal 35 mm DIN rail to EN 60715:2001 W x H x D 20 mm x 119 mm x 115 mm Screw terminal, max. 2.5 mm² approx. 150g KSR Datasheet ELM 03/2017 Page 18

2016 WIKA Alexander Wiegand SE & Co. KG All rights reserved. / Alle Rechte vorbehalten. WIKA and KSR are registered trademarks in various countries. WIKA and KSR sind geschützte Marken in verschiedenen Ländern. Prior to starting any work, read the operating instructions! Keep for later use! Vor Beginn aller Arbeiten Betriebsanleitung lesen! Zum späteren Gebrauch aufbewahren! Manufacturer contact hergestellt von Sales contact Vertrieb durch KSR Kuebler Niveau-Messtechnik AG Heinrich-Kuebler-Platz 1 69439 Zwingenberg am Neckar Germany Tel. +49 6263/87-0 Fax +49 6263/87-99 info@ksr-kuebler.com www.ksr-kuebler.com WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de KSR Datasheet ELM 03/2017 Page 19