Micro Motion Model 1500 Transmitter with the Filling and Dosing Application

Similar documents
Micro Motion Model 2400S Transmitters with MVD Technology

Series 1000 and 2000 Transmitters with MVD TM Technology

Micro Motion Series 1000 and 2000 Transmitters

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

Micro Motion Model RFT9739 Flow and Density Transmitter

Micro Motion LF-Series Low Flow Sensor and Transmitter

Micro Motion LF-Series Low Flow Flowmeter

Mass and Volume Flow Transmitter

Micro Motion Model RFT9739

Micro Motion Fork Viscosity Meters

Micro Motion Series 1000 and 2000 Transmitters

Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Mass Flow and Density Transmitter with FOUNDATION fieldbus

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Mass Flow and Density Transmitter

Micro Motion Filling Mass Transmitters with Modbus

Coriolis Massflowmeter

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Micro Motion Specific Gravity Meters (SGM)

Micro Motion Fork Density Meters

Coriolis Mass Flow Meter Model TM

Model RFT9709 Transmitter Instruction Manual

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

DeltaV SIS Logic Solver

Coriolis Massflowmeter

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

IFC 050 Technical Datasheet

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Micro Motion Gas Specific Gravity Meters

Magnetic Inductive Flowmeter

B850 Boiler House Energy Monitor

Micro Motion Compact Density Meters

IFC 050 Technical Datasheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Positioner with HART Communication Type 3780

B850 Boiler House Energy Monitor

OPTIFLUX 5000 Technical Datasheet

ATEX Installation Drawings and Instructions

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Kotron Model 82 CE RF Level Transmitter

Micro Motion Specific Gravity Meters (SGM)

Coriolis Massflowmeter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

MPU 200 Series B. Ultrasonic Gas Flowmeter. Specifications. Features. Principle of Operation

ED701 General Industry Pressure Transmitter

SISNet Distance Extenders

Sarasota CM200 Sarasota HME900 Density Converter Electronics

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

OPTITEMP TT 20 Technical Datasheet

TMU. Coriolis Mass Flow Meter. for liquids and gas

To be automatically connected to the nearest North American Technical Sales Office:

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Full Metal Variable Area Flowmeter and Counter Model BGF

Temperature Measurement

Kotron Sentinel Model 804 RF Level Transmitter

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

Kotron Sentinel Model 804 RF Level Transmitter

IFC 050 Technical Datasheet

PowerFlex 400 AC Drive Guide Specification

OPTIMASS 1000 Technical Datasheet

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology

SALES SERVICE +358 (0)

T5-600/T Electrical Tester

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

The Rosemount 848T Wireless Temperature Transmitter

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Micro Motion Model 1700 Transmitters with Analog Outputs 1700***A. Configuration and Use Manual Supplement. Configuration Operation Maintenance

OPTIFLUX 5000 Technical Datasheet

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

DeltaV SISnet Fiber Components

Rosemount 702 Discrete Input Transmitter

Analog Universal Module HART for Zone 2 Series 9468/33

Rosemount 148 Temperature Transmitter

SISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy

Temperature Measurement Transmitters for mounting in sensor head

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

Temperature Measurement Transmitters for mounting in sensor head

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Micro Motion Compact Density Meter (CDM)

PAD - Heavy Duty Differential Pressure Trasmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount 3101, 3102, and 3105

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Rosemount 333 HART Tri-Loop

MFC 400 Technical Datasheet

FH CMF Coriolis Mass Flow Meters

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

S200 I/O System Units

Head mounted Temperature Transmitter TF02/TF02-Ex

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

Liquid Level Switches

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Transcription:

Product Data Sheet PS-00571, Rev. C January 2008 Micro Motion Model 1500 Transmitter with the Filling and Dosing Application Micro Motion's Model 1500 transmitter with the filling and dosing application offers all the benefits of MVD technology, in a package specifically designed for filling, dosing, and bottling processes. 2400S Compact integral transmitter 1700 2700 Versatile fieldmount transmitter 1500 2500 Compact controlroom transmitter Integrated architecture optimized for filling performance Discrete valve control for best repeatability Real-time density and temperature measurement for quality control Automatic overshoot compensation for on-set-point fills every time Compatible with CIP, SIP, and EHEDG requirements Flexibility for simplified system design Compact size to maximize heads for rotary and linear filling systems Integral valve control for easy integration with control system Faster product turn-over due to cleanable sensor design Scalability to handle a wide range of container sizes and fillers with a single platform 3300 3350 3500 3700 Frequency-input discrete controller Integrated control and measurement platform

Micro Motion Model 1500 transmitter with the filling and dosing application Micro Motion's Model 1500 transmitter with the filling and dosing application combines the benefits of Micro Motion MVD technology, a software package specially designed for filling, dosing, and bottling processes, and compatibility with a wide range of sensors, including hygienic models for CIP, SIP, and EHEDG certification. Filling and dosing application. Micro Motion s new patented filling and dosing application is packed with features for precise control and delivery of small quantities of fluids over broad ranges of process conditions. Measure by mass or volume, with sensor accuracies up to 0,05%, independent of changes in temperature, density, or viscosity. Measure a wide range of both liquids and gases, including liquids with entrained air and suspended solids. We have experience with high-viscosity pastes, creams, emulsions, and slurries. Instantly validate product quality using the secondary density or temperature measurement, eliminating the need for expensive lab checks. Special update rate between transmitter and sensor enables near-instantaneous response Overshoot compensation (OC) automatically adjusts the valve closure signal to accommodate changing process conditions User-selectable OC algorithms: never overfill, never underfill, fixed, rolling average Select from a variety of standard measurement units, or define your own Set up one-stage or two-stage filling, using standard discrete (ON/OFF) valves, or configure the transmitter to control a threeposition analog valve Automatic or manual purge cycle Sensors suitable for both CIP and SIP cleaning, enabling rapid product changeover Contents Model 1500 platform.......................3 Application architecture and process...........4 Accuracy, reliability, and repeatability..........5 User interface............................6 Electrical connections......................7 Input/output signals........................7 Digital communications.....................8 Power supply.............................8 Environmental limits....................... 8 Environmental effects...................... 8 Hazardous area classifications............... 9 Physical specifications..................... 9 Transmitter dimensions.................... 10 Remote core processor dimensions.......... 11 Ordering information...................... 12 2 Model 1500 Transmitter with the Filling and Dosing Application

Model 1500 platform Micro Motion s popular Model 1500 transmitter provides the platform for the filling and dosing application. The Model 1500 delivers a big transmitter in a small package. Designed for DIN rail mounting, it measures a tiny 112 mm 99 mm 45 mm perfect for carousels or skids. Embedded MVD technology provides front-end digital processing, for dramatically reduced signal noise, faster response time, and expanded diagnostics. Meter verification. Meter verification is an application available in conjunction with Micro Motion ELITE meters utilizing the enhanced core processor. Initiated by a user command, the method measures mechanical characteristics of the meter to a very high accuracy. When a change in the structural stiffness of the sensor tubes is detected, the device indicates the meter may no longer meet factory specifications. The structural integrity test verifies complete meter performance from tube structure to electronics to signal processing for complete performance certainty. The Model 1500 connects to a wide range of Micro Motion sensors, using standard 4-wire cable for significantly reduced installation costs. And because the sensor is powered by the transmitter, there s no need to run separate power to the sensor. Three input/output channels can be configured for ma output, discrete output, discrete input, or threeposition analog valve control. A status LED on the transmitter face indicates transmitter health at a glance. Model 1500 Transmitter with the Filling and Dosing Application 3

Application architecture and process Simple one-stage fill process Process data from sensor The host downloads the target to the Model 1500, which opens the controlling valve. When the target is reached, the Model 1500 closes the controlling valve and reports the totals to the host system. Modbus connection to host Discrete output controlling valve Two-stage control One of several two-stage control schemes is illustrated here. The secondary valve opens to start the fill. The primary valve opens and closes at user-configured points during the fill. The secondary valve closes slightly before the target is reached, at a point determined by the Overshoot Compensation feature. Process data from sensor Discrete output controlling primary valve Discrete output controlling secondary valve Overshoot Compensation Open secondary FLOW Close secondary Compensation Open primary Close primary TARGET 4 Model 1500 Transmitter with the Filling and Dosing Application

Accuracy, reliability, and repeatability The Model 1500 transmitter with the filling and dosing application can be paired with any 4-wire or 9-wire Micro Motion sensor to provide highly accurate and repeatable mass flow, volume flow, density, and temperature measurements, all in real time. Underfilling a container puts the producer at risk with customers and regulatory agencies, yet overfilling can create significant cost issues, as well as possible problems with spills, safety, and cleanup. Reducing the variation in product fills can have a significant impact on a manufacturer s bottom line. Typical system accuracies provide standard deviation of fills below 0,2. A program that combines a Micro Motion measurement system with statistical quality control (SQC) analysis can allow you to lower the fill target squeeze and shift and reduce overfill while still meeting regulatory requirements. Nominal fill size New flowmeter setpoint Original flowmeter setpoint Model 1500 Transmitter with the Filling and Dosing Application 5

User interface ProLink II Micro Motion s ProLink II software provides a simple, powerful interface to the Model 1500 transmitter and the filling and dosing application. Designed for both configuration and operation, it runs on almost any Microsoft Windows platform, and can be connected to the transmitter on a temporary or permanent basis. User-written programs For users who want to integrate control and measurement into their own programs, complete documentation of the Modbus interface to the transmitter and the application is available from Micro Motion. 6 Model 1500 Transmitter with the Filling and Dosing Application

Specifications Electrical connections Input/output connections Power connection Service port connection Core processor connection Three pairs of wiring terminals for transmitter outputs One pair of terminals for digital communications (Modbus/RS-485) Screw terminals accept stranded or solid conductors, 0,20 to 3,5 mm 2 Two pairs of terminals for the power connection: Either pair accepts DC power The remaining pair is used for making a jumper connection to another transmitter Screw terminals accept stranded or solid conductors, 0,20 to 3,5 mm 2 One pair of terminals supports Modbus/RS-485 signal or service port mode. On device power-up, user has 10 seconds to connect in service port mode. After 10 seconds, the terminals default to Modbus/RS-485 mode. Two pairs of terminals for the 4-wire connection to the core processor: One pair is used for the RS-485 connection to the core processor One pair is used to supply power to the core processor Screw terminals accept stranded or solid conductors, 0,20 to 3,5 mm 2 Input/output signals One active 4 20 ma output One or two discrete outputs One discrete input One zero button Not intrinsically safe Isolated to ±50 VDC from all other outputs and earth ground Maximum load limit: 600 Ω Can report mass flow or volume flow, or can control a two-position discrete valve or threeposition analog valve Output is linear with process from 3,8 to 20,5 ma, per NAMUR NE43 (June 1994) Channels B and C can be configured as discrete outputs Can report fill in progress or fault, or can control discrete valve Maximum sink capability is 500 ma Configurable for internal or external power: Internally powered to 15 VDC ±3%, internal 2.2 kω pull-up, or Externally powered 3 30 VDC max., sinking up to 500 ma at 30 VDC maximum Channel C can be configured as a discrete input Configurable for internal or external power Can be used to begin fill, end fill, pause fill, resume fill, reset fill total, reset mass total, reset volume total, or reset all totals (includes fill total) Used to start the flowmeter zeroing procedure Model 1500 Transmitter with the Filling and Dosing Application 7

Specifications continued Digital communications Service port Modbus/RS-485 After device power up, terminals 33 and 34 are available in service port mode for 10 seconds: Modbus RTU protocol 38400 baud No parity One stop bit Address = 111 After 10 seconds, terminals 33 and 34 default to Modbus/RS-485: Modbus RTU or Modbus ASCII protocol (default: Modbus RTU) 1200 to 38400 baud rate (default: 9600) Stop bit configurable (default: one stop bit) Parity configurable (default: odd parity) Power supply Requires DC power Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements Power requirements Fuse 19,2 to 28,8 VDC, 6,3 watts maximum At startup, transmitter power source must provide a minimum of 1,0 amperes of short-term current per transmitter Length and conductor diameter of the power cable must be sized to provide 19,2 VDC minimum at the power terminals, at a load current of 330 ma IEC 1,6A slow blow fuse Environmental limits Ambient temperature limits Operating: 40 to +55 C Storage: 40 to +85 C If temperature is above 45 C and you are mounting multiple transmitters, they must be mounted at least 8,5 mm apart. Humidity limits 5 to 95% relative humidity, non-condensing at 60 C Vibration limits Meets IEC68.2.6, endurance sweep, 5 to 2000 Hz, 50 sweep cycles at 1,0 g Environmental effects EMI effects Meets EMC directive 89/336/EEC per EN 61326 Industrial Complies with NAMUR NE21 (May 1999) Ambient temperature effect On analog output ±0,005% of span per C 8 Model 1500 Transmitter with the Filling and Dosing Application

Specifications continued Hazardous area classifications CSA (1) C-US Transmitter Sensor and sensor wiring to transmitter Class I, Div. 2, Groups A, B, C, and D Class I, Div. 1, Groups C and D or Class II, Div. 1, Groups E, F, and G ATEX (2) CE 0575 ATEX II(2) G [EEx ib] IIB/IIC For ATEX compliance, ambient temperature is limited to 40 to +55 C (1) CSA is a Canadian approvals agency that provides approvals accepted both in Canada and in the U.S.A. (C-US). (2) ATEX is a European directive. Physical specifications Housing Polyamide PA 6.6 Weight Dimensions Status LED Zero button Mounting and cabling Maximum cable lengths between sensor and transmitter 0,24 kg See following figures for dimensions of the Model 1500 transmitter and the remote core processor. For sensor dimensions, refer to sensor specifications. Three-color LED status light on face of transmitter indicates flowmeter condition at a glance, using a solid green, yellow or red light. Zero in progress is indicated by a flashing yellow light. A zero button on the face of the transmitter can be used to start the transmitter zero process. DIN rail transmitters are mounted on a 35 mm rail which requires an independent ground. They may be used with any Micro Motion 4-wire or 9-wire sensor. For a 4-wire connection, use standard 4-wire twisted-pair shielded signal cable, up to 300 meters in length, between the sensor and the transmitter. For 9-wire sensors, the remote core processor must be mounted within 20 meters of the sensor, using 9-wire Micro Motion signal cable. The transmitter can then be mounted up to 300 meters from the remote core processor. Cable type Wire gauge Maximum length Micro Motion 9-wire Not applicable 20 meters (1) Micro Motion 4-wire Not applicable 300 meters User-supplied 4-wire (2) Power wires (VDC) 0,35 mm 2 90 meters 0,5 mm 2 150 meters 0,8 mm 2 300 meters Signal wires (RS-485) 0,35 mm 2 or larger 300 meters (1) This is the maximum distance between a remote core processor and the sensor. An additional run of 4-wire cable is needed between the remote core processor and the transmitter. (2) Micro Motion recommends using Micro Motion cable. Model 1500 Transmitter with the Filling and Dosing Application 9

Specifications continued Transmitter dimensions Dimensions in mm Side view Bottom view DIN rail 35 99 112 45 8,5 or greater Mounting multiple transmitters with temperatures above 45 C End bracket or end stop 8,5 mm minimum spacing 10 Model 1500 Transmitter with the Filling and Dosing Application

Specifications continued Remote core processor dimensions Dimensions in mm Ø111 144 2X 76 57 67 158 4X Ø10 71 To centerline of 2 pipe 146 Pole Mount 71 114 116 Wall Mount 64 1/2 14 NPT OR M20 X 1,5 61 43 These dimensions apply only to the core processor component when mounted remotely from the sensor. For dimensions of the core processor when mounted integrally with the sensor, see the sensor specifications. 3/4 14 NPT 84 Model 1500 Transmitter with the Filling and Dosing Application 11

Ordering information Model Product description 1500 Micro Motion Coriolis MVD 1500 single variable flow transmitter Code Mounting D 4-wire remote 35 mm DIN rail transmitter B 4-wire remote 35 mm DIN rail transmitter with 9-wire remote core processor (includes 3 m CFEPS cable) Code Power 3 19,2 to 28,8 VDC Code Conduit connections A None (for use with mounting option code D) B (1) E (1) F (1) G (1) Code C Code B Code M C A B P (2) 1/2-inch NPT remote core processor no gland M20 remote core processor no gland Remote core processor brass/nickel cable gland Remote core processor stainless steel cable gland Output options One ma, two DO; RS-485 Terminals Screw terminals Approvals Micro Motion standard (no approval) CSA (Canada only) CSA C-US (U.S.A. and Canada) ATEX safe area with intrinsically safe sensor outputs NEPSI safe area Continued on next page (1) Available with mounting code B only. (2) Available only with language code M (Chinese). 12 Model 1500 Transmitter with the Filling and Dosing Application

Ordering information continued Code Language A Danish installation manual and English configuration manual D Dutch installation manual and English configuration manual E English installation manual and English configuration manual F French installation manual and French configuration manual G German installation manual and German configuration manual H Finnish installation manual and English configuration manual I Italian installation manual and English configuration manual J Japanese installation manual and English configuration manual M Chinese installation manual and English configuration manual N Norwegian installation manual and English configuration manual O Polish installation manual and English configuration manual P Portuguese installation manual and English configuration manual S Spanish installation manual and Spanish configuration manual W Swedish installation manual and English configuration manual C Czech CE requirements, English installation manual, and English configuration manual B Hungarian CE requirements, English installation manual, and English configuration manual K Slovak CE requirements, English installation manual, and English configuration manual T Estonian CE requirements, English installation manual, and English configuration manual U Greek CE requirements, English installation manual, and English configuration manual L Latvian CE requirements, English installation manual, and English configuration manual V Lithuanian CE requirements, English installation manual, and English configuration manual Y Slovenian CE requirements, English installation manual, and English configuration manual Code Software options 1 B Filling and dosing application Code Software options 2 Z No software options 2 C (1) Code Z Meter verification, structural integrity method Factory options Standard product Typical model number: 1500 D 3 A C B M E B C Z (1) Available only with Micro Motion ELITE sensor with enhanced core processor (electronic interface codes 2 and 4). Model 1500 Transmitter with the Filling and Dosing Application 13

14 Model 1500 Transmitter with the Filling and Dosing Application

Model 1500 Transmitter with the Filling and Dosing Application 15

Micro Motion The undisputed leader in flow and density measurement World-leading Micro Motion measurement solutions from Emerson Process Management deliver what you need most: Technology leadership Micro Motion introduced the first reliable Coriolis meter in 1977. Since that time, our ongoing product development has enabled us to provide the highest performing measurement devices available. Product breadth From compact, drainable process control to high flow rate fiscal transfer look no further than Micro Motion for the widest range of measurement solutions. Unparalleled value Benefit from expert phone, field, and application service and support made possible by more than 500000 meters installed worldwide and 30 years of flow and density measurement experience. WWW.micromotion.com 2008 Micro Motion, Inc. All rights reserved. Micro Motion is committed to continuous product improvement. As a result, all specifications are subject to change without notice. ELITE and ProLink are registered trademarks, and MVD and MVD Direct Connect are trademarks of Micro Motion, Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Micro Motion and Emerson logos are trademarks and service marks of Emerson Electric Co. All other trademarks are property of their respective owners. Emerson Process Management Micro Motion Americas Worldwide Headquarters 7070 Winchester Circle Boulder, Colorado USA 80301 T: 800 522 6277 T: +1 (303) 527 5200 F: +1 (303) 530 8459 Mexico T: 52 55 5366 2622 Argentina T: 54 11 4837 7000 Brazil T: 55 15 3238 3677 Venezuela T: 58 26 1731 3394 Emerson Process Management Micro Motion Europe/Middle East Central & Eastern Europe T: +41 41 7686 111 Dubai T: 971-4 8835235 France T: 0800 917 901 Germany T: 0800 182 5347 Italy T: 8008 77334 The Netherlands T: (31) 318 495 555 U.K. T: 0870 240 1978 Russia/CIS T: +7 495 981 9811 Emerson Process Management Micro Motion Asia Pacific Australia T: (61) 3 9721 0200 China T: (86) 21 2892 9000 India T: (91) 22 5662 0566 Japan T: (81) 3 5769 6803 Korea T:(82)234384600 Singapore T: (65) 6 777 8211