Ultrasound physical principles in today s technology

Similar documents
Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

Ultrasound Imaging Ultr Michael Dadd 2007

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

ULTRASONIC IMAGING of COPPER MATERIAL USING HARMONIC COMPONENTS

Artifacts. Artifacts. Causes. Imaging assumptions. Common terms used to describe US images. Common terms used to describe US images

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life.

CHAPTER 1 INTRODUCTION

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

Ultrasound & Artifacts

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

12/26/2017. Alberto Ardon M.D.

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission:

Ultrasonic Linear Array Medical Imaging System

Photomultiplier Tube

Interaction of Sound and. logarithms. Logarithms continued. Decibels (db) Decibels (db) continued. Interaction of Sound and Media continued

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Medical Imaging (EL582/BE620/GA4426)

Session: 1E CONTRAST AGENTS II Chair: K. Ferrara University of California-Davis. 1E-1 10:30 a.m.

3. Ultrasound Imaging(2)

Resolution Enhancement and Frequency Compounding Techniques in Ultrasound.

ACOUSTIC MICRO IMAGING ANALYSIS METHODS FOR 3D PACKAGES

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

Design Your Performance

Where DSP meets Measurement Science: A Sound Example. By Andrew Hurrell PhD

Reconfigurable Arrays for Portable Ultrasound

Linear arrays used in ultrasonic evaluation

Doppler Ultrasound. Amanda Watson.

MULTI-FREQUENCY ULTRASOUND IMAGING: PHANTOM STUDY

Lecture 3: Wireless Physical Layer: Modulation Techniques. Mythili Vutukuru CS 653 Spring 2014 Jan 13, Monday

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.

Introduction to Ultrasound Physics

Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m.

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

Signal Characteristics

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2

MAKING TRANSIENT ANTENNA MEASUREMENTS

An acousto-electromagnetic sensor for locating land mines

APPLYING SYNTHETIC APERTURE, CODED EXCITATION, AND TISSUE HARMONIC IMAGING TECHNIQUES TO ALLOW ULTRASOUND IMAGING WITH A VIRTUAL SOURCE ROBYN T.

Sonic Distance Sensors

Optimization of Axial Resolution in Ultrasound Elastography

Proceedings of Meetings on Acoustics

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

H 2 O and fat imaging

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ]

Principles of Ultrasound Imaging Image Optimization

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer

MRI Metal Artifact Reduction

Fig. 1

Ultrasonic Imaging of Tight Crack Surfaces by Backscattered Transverse Wave with a Focused Transducer

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

4 Working With Scan Modes

Lecture #5: Using Nonlinearity: Harmonic and Contrast-enhanced Ultrasound. Lecturer: Paul Sheeran

π code 0 Changchun,130000,China Key Laboratory of National Defense.Changchun,130000,China Keywords:DPSK; CSRZ; atmospheric channel

Real Time Deconvolution of In-Vivo Ultrasound Images

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

Standard Guide for Evaluating Characteristics of Ultrasonic Search Units 1

Impulse Response as a Measurement of the Quality of Chirp Radar Pulses

Communication Engineering Prof. Surendra Prasad Department of Electrical Engineering Indian Institute of Technology, Delhi

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

EE 422G - Signals and Systems Laboratory

Sonar advancements for coastal and maritime surveys

Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI

Comprehensive Ultrasound Research Platform

Technician License Course Chapter 2. Lesson Plan Module 2 Radio Signals and Waves

Acousto-optic imaging of tissue. Steve Morgan

BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Operation and Sound Field of an Ultrasonic Biplane-Array

Compound quantitative ultrasonic tomography of long bones using wavelets analysis

Cancellation of Space-Based Interference in Radio Telescopes 1. Lou Nigra 2. Department of Astronomy University of Wisconsin Madison, Wisconsin

Laser Diode. Photonic Network By Dr. M H Zaidi

DC-6. Diagnostic Ultrasound System

Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology

IPC TECHNICAL PAPER SERIES NUMBER 310

Pulse Compression. Since each part of the pulse has unique frequency, the returns can be completely separated.

High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure

Implementation of Orthogonal Frequency Coded SAW Devices Using Apodized Reflectors

Fast, portable, user-friendly...the complete C-scan solution.

Piezoelectric Fiber Composite Ultrasonic Transducers for Guided Wave Structural Health Monitoring

A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING

Digital Reconstruction and Display of Compound Scan Ultrasound Images

Explain what is meant by a photon and state one of its main properties [2]

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

Transcription:

Education Ultrasound physical principles in today s technology Brian Starkoff M.App.Sc.(Med. Ultrasound), AMS Holland Park Brisbane Queensland Australia Correspondence to email starkoff@optusnet.com.au Abstract Introduction: New technology options are being provided on modern ultrasound machines such as tissue harmonic imaging, panoramic imaging, encoded pulses, mechanical and matrix 4D ultrasound and elastography. The increase in available features requires enhanced knowledge of the clinical benefits associated with each feature and of the additional diagnostic information in the images. However the question arises as to the necessity of understanding how these new technologies work. Also, ultrasound machines have become much more automated in recent years, with designers making it easier for users to produce excellent quality images with minimal technical input. Discussion: System presets provide adjustments to a variety of basic settings without the user requiring the knowledge of what each setting is doing. The developments in machine design and the increased level of automation pose an interesting question for sonologists and sonographers: Is there a need to know as much about the physical principles of ultrasound today as was required in the past? Conclusion: To answer this question, this article will look at just one recent advance in ultrasound Tissue Harmonic Imaging. The various mechanisms of this technology will be discussed with reference to the underlying principles of basic ultrasound physics. The conclusion provided is that a good grounding in the physics of ultrasound remains of vital importance in understanding new technologies and enabling informed decisions to be made on their use. Keywords: advances, harmonics, physics, technology. Introduction The field of diagnostic ultrasound has come a long way in its development since the Curie brothers discovered the wonderful characteristics of piezoelectric crystals in the late 1800s. The machines have developed from primitive water transmission techniques, through articulated arm contact scanners and the water bath UI Octoson. 1 Today, although ultrasound machines have become very complex with an array of fancy features, they have also become much more automated. There is no need to adjust a multitude of switches and knobs before commencing a scan. It is simply a matter of selecting the transducer of choice, pressing the X preset, the Y patient type, and the computer system selects a large number of settings that will be suitable for the scan. Also, many machines have single button optimisation controls which analyse the screen image and automatically make adjustments to a number of settings to enhance chosen aspects of the image such as colour flow, spectral trace or greyscale imaging. These optimisation controls reduce the need to make manual adjustments during a scan. So is it really necessary to know as much about the physics of ultrasound today as it was several years ago? An answer to this question lies in the analysis of just one technology that has been introduced relatively recently and is continuing in its development: tissue harmonic imaging (THI). Harmonics Modern ultrasound machines now commonly feature THI. Press a button and the image appears with a bit more contrast and it is often easier to detect subtle echogenicity changes. But what type of harmonics are being used, how does it work, what are the specific advantages of using harmonics and, more important, what are its limitations? An important point to remember is that an ultrasound pulse consists of a range of frequencies, not a single frequency. For example, a pulse from a 5 MHz transducer could be composed of a range of frequencies from 4 MHz to 6 MHz (Figure 1). This range of frequencies is called the bandwidth. Harmonics were initially used with contrast agents, however it was soon discovered that harmonic frequencies were generated during the passage of the ultrasound beam through tissue. When the compression wave of a pulse leaves the transducer, it is sinusoidal. Then, as it passes through tissue, it undergoes some distortion (Figure 2). In other words it changes 4 AJUM February 2014 17 (1)

Ultrasound physical principles in today s technology Figure 1: The frequency spread of an ultrasound pulse is called the bandwidth. A pulse transmitted at a centre frequency (f 0 ) would also contain frequencies from f 1 to f 2. Figure 2: The ultrasound pulse starts out with a sinusoidal waveform (2a). As the wave passes through tissue (2b), the wave speeds up very slightly during the compression phase (solid arrows) and during the rarefaction phase the wave slows slightly (open arrows). This causes a distortion of the wave and creates the harmonic frequencies. shape. This distortion occurs because as the wave compresses the tissue, the speed of sound in the compressed tissue increases a little and the wave travels slightly faster. In the rarefied (or low compression) area of the wave, the speed of sound is a little lower and the wave travels slightly slower. When the wave distorts in this way, other frequencies develop in the wave. These are the harmonic frequencies. Echoes that return from the patient are a mirror image of the pulse, so the echoes also have the distortion, and therefore the harmonic frequencies. Harmonics are frequencies at multiples above the fundamental frequency the frequency that was emitted from the transducer. (Note that the fundamental frequency is also known as the first harmonic 2,3 and these terms are used interchangeably). For example, if the pulse is transmitted at 3 MHz (the fundamental frequency), each returning echo will consist of a 3 MHz frequency (with its inherent bandwidth) as well as a 6 AJUM February 2014 17 (1) 5

Brian Starkoff Figure 3: Transmitted and reflected wave shapes (3a) and a graph showing the frequency spread in returning echoes from a 3 MHz pulse (3b). The 3 MHz fundamental frequency component and the 6 MHz second harmonic component each have an inherent bandwidth. Figure 4: Ultrasound beam at the fundamental frequency (open straight arrows) with its side lobes (curved arrows) and the generated second harmonic frequency profile (solid arrows) (4a). Multiple low intensity scattered beams occur throughout the tissue (4b). When THI is activated, the fundamental frequency is removed leaving only the harmonic frequency (4c). MHz frequency (the second harmonic). This second harmonic frequency will also have an inherent bandwidth of frequencies (Figure 3). The pulse also generates higher harmonic frequencies (e.g. 9 MHz and 12 MHz), however these high frequencies are attenuated significantly in the tissue and are not utilised. The fundamental and second harmonic frequencies are not separate they are combined as a complex (distorted) wave. When THI is turned on, the electronics of the machine removes the fundamental frequency component and leaves the second harmonic frequency which is then used to form the image. 6 AJUM February 2014 17 (1)

Ultrasound physical principles in today s technology Figure 5: An ultrasound beam is much thicker in the orthogonal plane than in the scan plane which results in a relatively large slice thickness (5a). When THI is activated, the beam becomes narrower in all planes which results in a thinner slice (5b). For useable levels of harmonics to be generated, two things need to happen: The pulse must travel some distance through the tissue to generate the distortion. The pulse must have relatively high intensity. Figure 4a shows a typical ultrasound beam with side lobes and a representation of the harmonic frequency profile. Note that the harmonics are generated in the high intensity central part of the beam. They are not generated to any degree in the weak intensity side lobes or in the lower intensity edges of the beam. The transducer also receives a moderate amount of backscatter caused by scattered echoes within the beam interacting with scatterers in adjacent tissue (Figure 4b). These backscattered echoes are very low intensity and do not generate any significant harmonics. When THI is activated, only the harmonic frequency component is detected, greatly improving the beam profile (Figure 4c). The side lobes (and their potential artifacts) disappear, the beam effectively becomes narrower which results in improved lateral resolution and the removal of much of the backscatter improves the signal to noise ratio (SNR) thus improving contrast resolution. Also, because the beam becomes narrower in the orthogonal plane as well as the scan plane, slice thickness is reduced which further improves contrast resolution (Figure 5). The fundamental frequency can be removed by several different methods: Bandwidth filtering Pulse inversion harmonics Coded harmonics Differential harmonics. Filtering In the early stages of harmonic development, the returning echoes went through a relatively simple frequency filter, which removed the fundamental frequency and its associated bandwidth frequencies. Modern ultrasound machines now generate very short pulses (which improves axial resolution), however a short pulse creates a very wide bandwidth. This causes significant overlap of the fundamental and harmonic frequencies (Figure 6). The simple filtering method cannot be used to remove the fundamental frequency because it would remove a large part of the second harmonic frequency component as well. This problem could be overcome by increasing the pulse length when THI is used (which reduces the bandwidth), however axial resolution would be degraded. Pulse inversion Pulse inversion harmonics is a clever way of avoiding the filtering problem. Two pulses are sent out for each beam path with the second pulse being 180 o phase inverted to the first pulse. The second phase inverted pulse is therefore completely opposite in phase to the first pulse. The echoes from each of the pulses are stored by the computer and then analysed. Because the echoes are mirror images of the pulses, the two sets of echoes are also phase inverted. The computer then adds the two sets of echoes. If harmonic distortion had not occurred, the two echoes would undergo destructive interference and cancel (Figure 7a). However, because the returning echoes are distorted, they will not add up to zero. The result of this addition will produce the harmonic frequency (Figure 7b). AJUM February 2014 17 (1) 7

Brian Starkoff Figure 6: The increased bandwidth from the very short pulses of modern ultrasound machines causes a large overlap of the fundamental and 2nd harmonic frequencies. Figure 7: If no harmonic distortion of the waves had occurred, the two phase inverted echoes would cancel each other out (7a). Because the waves are distorted, they are not exact mirror images of each other so that when they are added, a resultant frequency remains (7b). This is the harmonic frequency component of the wave. In simplistic terms, the two inverted fundamental frequencies have been added, cancelled each other out and removed from the final result. What remains is the result of the distortion the harmonic frequencies. The advantage of this technique is that the wide bandwidth of the short pulses is not a problem. However it has the disadvantage that two pulses are required for each echo set which reduces the frame rate resulting in degraded temporal resolution. Also, if there is any movement of a reflector between the pulses, the fundamental frequency is not completely removed. 4 Coded harmonics With coded harmonics, a unique code is applied to the pulses using either binary or FM Chirp encoding. Binary encoding involves the application of a sequence of wavelengths with a binary signature (Figure 8b) while with FM Chirp encoding, the frequency of the pulse emitted from the transducer is increased at a specific rate during the generation of the pulse itself (Figure 8c). It has been shown that FM Chirp encoding is the code type more suited to harmonic imaging. 5 8 AJUM February 2014 17 (1)

Ultrasound physical principles in today s technology H Figure 8: An uncoded pulse (8a). Examples of three different methods of applying a binary code to a pulse (8b). An FM Chirp encoded pulse and a graph of the unique rate of frequency increase for that pulse (8c). Figure 9: Transmission of two discrete frequencies in a single pulse (9a). Complex frequency profile of the returning echoes. The two lower frequency components are used for image production (9b). Pulse encoding enables the fundamental frequency to be isolated and then subtracted from the returning echo rather than filtered out which permits the use of short pulses with their inherent wide bandwidth. A combination of Chirp pulse encoding and pulse inversion will further improve the SNR and therefore enhance the harmonic image. 6 Differential harmonics Differential harmonics is another approach used to separate the fundamental frequency. Two specific frequencies are contained within each pulse. It can be shown mathematically that the returned echoes contain frequencies at the sum and difference of the transmitted frequencies as well as their harmonics 3 (Figure 9). The two lower frequency components of the echo are used in AJUM February 2014 17 (1) 9

Brian Starkoff the image production process. Using a technique similar to pulse inversion, the fundamental frequency is able to be subtracted from the returning echoes which avoids the problems with filtering. Discussion Within this article s description of harmonics, the following physics principles have been mentioned: basic wave physics, beam profile, beam intensity variation, lateral resolution, axial resolution, contrast resolution, temporal resolution, bandwidth and side lobes. Without knowledge of these principles, it is not possible to have a full understanding of how the various forms of harmonics work and therefore the advantages and limitations of the type that is installed on the machine that is being used. Which is the best type of harmonics to have on a machine? It is an interesting question and unfortunately there may not be an available choice. The decision on which machine to acquire is based on many factors including cost, range of features, ease of use, image quality, upgradeability and compatibility with other department equipment. A lower cost, more basic machine might only have simple harmonics with bandwidth filtering. A mid or top range machine would almost certainly come with more advanced harmonics. What is more important is that user needs to know what type of harmonics is on the machine, understand the basics of how it works and appreciate any limitations it might have. For example, if it is required to achieve high frame rates for an examination, then pulse inversion techniques will compromise the maximum achievable rate. Therefore it might be beneficial to switch off THI to optimise frame rate with certain examinations. However if the machine has multiple beamformers that enable several scan lines to be acquired simultaneously, then frame rates may well be more than adequate. If the machine has simple (bandwidth filtered) harmonics, it needs to be remembered that that there may be a trade-off with axial resolution when THI is activated. Conclusion One would think that the highly automated modern ultrasound machines would reduce the necessity for users to have in-depth knowledge of the principles of the machine s functions. However the increased automation has the potential of producing a degree of complacency in sonologists and sonographers resulting in a reduction of their knowledge required to make manual adjustments for increasing the diagnostic quality of the images, particularly with a challenging patient. This discussion has looked at only one of ultrasound s more recent developments and it is apparent that without a high level of understanding of basic ultrasound principles, users are limited in their ability to make informed decisions on the use of this feature. Also, there are many other features in use or being developed such as encoded pulses that enable blood flow to be visualised with grey scale imaging, extended field of view imaging, elastography, compound imaging, image fusion and microbubble therapy. To understand the advantages and limitations of these features, their principles need to be understood and this cannot be done without sound background knowledge. Is knowledge of ultrasound physical principles required as much today as was necessary in previous years? Yes more than ever. References 1 Carpenter D, Kossoff G, Garrett WJ, Daniel K, Boele P. The UI Octoson - A New Class of Ultrasonic Echoscope. Australas Radiol 1997; 21 (1): 85 89. 2 Gill R. The Physics and Technology of Diagnostic Ultrasound: A Practitioner s Guide. Sydney: High Frequency Publishing; 2012. 3 Chiou S-Y, Forsberg F, Fox TB, Needleman L. Comparing Differential Tissue Harmonic Imaging with Tissue Harmonic and Fundamental Gray Scale Imaging of the Liver. J Ultrasound Med 2007; 26: 1557 63. 4 Tanabe M, Yamamura T, Kan ON. In: Tanabe M, editor. Tissue Harmonic Imaging with Coded Excitation, Ultrasound Imaging. Vienna: InTech, 2011. 5 Arshadi R, Yu AC, Cobbold RS. Coded Excitation Methods for Ultrasound Harmonic Imaging. Can Acoust 2007; 35 (2): 35 46. 6 Park J, Huang Y, Chen R, Lee J, Cummins TM, Zhou Q, et al. Pulse inversion chirp coded tissue harmonic imaging (PI-CTHI) of Zebrafish heart using high frame rate ultrasound biomicroscopy. Ann Biomed Eng 2013; 41 (1): 41 52. 10 AJUM February 2014 17 (1)