Single Flex and Double Flex Couplings (i)

Similar documents
Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

Disc Caliper Brake Model DBSE

Tension Control Clutch Model TCC-7

Caliper Brake WINDCAL 90

Dual and Quad Faced Brakes DFB and QFB Models 1150, 1650, 2200, and 2500 AIR CHAMP PRODUCTS. User Manual. (i)

Flange Mounted Enclosed Clutch-Brakes FMCBE Models 625, 875, and 1125 with Locking Key

FMCBE 625 and 875 Clutch-Brakes BISSC Certified With and Without Locking Key FORM NO. L F-0615 FORM NO. L F-0615

WEB CONTROL PRODUCTS. User Manual. Tension Control Clutch. Models TCC-7 FORM NO. L D-0914 FORM NO. L D-0914

AIR CHAMP PRODUCTS. FMBES-CC Models 625, 875, 1125, and 1375 FORM NO. L E-0714 FORM NO. L E-0714

Flange Mounted Enclosed Clutch with Spring Engaged Brake

Installation Manual Tilt Leg

MaxLite LED Self-Driven LiteBars

Models SSE-450, SSE-600, SSE-800, and SSE-1000

Clutch and Pilot Assembly Models DPC-13T and DPC-15T

MDO, MDB, MIDO, MIDB,

Installation Manual XRL Solar Rail System

Owner s Manual & Safety Instructions

Single Arm Pole Mount. Installation Manual Edition v1.01. For models: UNI-SA/14 UNI-SA/21.5 UNI-SA/26 UNI-SA01-MAN

Instruction Sheet D-CPU. Secure CPU Holder

00108/00110 INSTRUCTION MANUAL

Specifications. Important Safety Information

Your Performance Partner

Wenger Corporation 2010 Printed in China 02/10 Part #148H Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

Owner s Manual & Safety Instructions

Tablet Arm for Wenger Playright Chairs

INCLUDES BENCH MODELS:

Installation Manual. Tamarack Solar Products. Top of Pole Mount Edition v1.01. For models:

Check us out on-line! Installation Instructions

Mortising Attachment

Installation Manual Roof Zone Ladder Rack

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Models 2030 and 2040

Models 2130 and 2140

Models 2130 and 2140

Rojek Woodworking Machinery Interchangeable Shaper Spindle Installation and User s Guide

Instruction Sheet SNE SERIES. Cable Chase

Sunset Swings By Health in Motion, LLC

TED-Kit 2, Release Notes

Guitar Mobile Storage Rack

MaxLite Linear Strip ECO Series

Manual Carton Closing Staplers

CRD 410 MANUAL FITTING INSERTER

Instruction Sheet. VRS Series. Vertical Rackmount system for multiple cable/satellite receivers

Radio Remote Controls Manual K Series

Shrinker and stretcher

SERIES M MIXER MASTS

Models 2230 and 2240

Planishing hammer stand For use with SKU Planishing hammer

Guard Rail with In-Fill Panel

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

Peg Board Option for the GearBoss Shelving System

Tilting Flat Panel Wall Mount Installation Guide

Tilting, Swiveling & Rotating Flat Panel Wall Mount

14 Piece Slide Hammer and Puller Set

LC200WT Security Wall Mount with Tilt for up to 32" Flat Screens

SHRINKER/STRETCHER SET Create radius bends and contours in sheet metal

LC6X4WTM Security Wall Mount with Tilt for up to 60" Flat Screens with VESA 600mm x 400mm or less

INSTRUCTION SHEET STRUT DRIVER RETROFIT KIT PN: 22-79SDRF

VAN STORAGE SOLUTIONS FOR THE WAY YOU WORK

Fletcher F-3000 / F-3100 Accessory Laser Kit

MANUAL METAL SHRINKER/STRETCHER

Installation Manual. Tamarack Solar Products. Side of Pole Mount Edition v1.02. For models:

COMPETITOR CB-610 STANDARD BENCH

Magnum low voltage drawout circuit breaker IEC horizontal stab cassette shutter kit (double wide A cassettes)

Spa & Hot Tub Necessities. Cover Removal System Installation & Use Manual

Operating Instructions and Parts Manual SLT-1100 Jumbo Scissor Lift Table

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

Comfort 10S Wall Hardwire Installation and Operations Manual

9 QUICK RELEASE WOODWORKING VISE

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Dairy Cap Chuck. Service & Installation Instructions. An Altra Industrial Motion Company P-2021-WE

MODEL M1023 QUICK CHANGE COLLET ATTACHMENT INSTRUCTION MANUAL. Phone: On-Line Technical Support:

Type XTSR71 Sizes

( ) CanPRO. Recommended Handle Turns: Can Size Diameter Handle Turns #2 3" 3 Revolutions #5 5" 5 Revolutions #10 6" 6 Revolutions.

Owner s Manual LSP38 38 Lawn Sweeper

10 Ton Pull Back Ram

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

automatic embosser & die cutter USER MANUAL

INSTALLATION INSTRUCTIONS: DISC SANDER SHIELDS UPPER BELT SANDER SHIELDS LOWER BELT SANDER SHIELDS

Model 6360/6361. Ambulance Cot Fastener INSTALLATION/OPERATION INSTRUCTIONS. IMPORTANT Keep manual on file at all times.

FSCTD Dual Back to Back Flat Screen Ceiling Mount

Owner s Manual GS2010 Garden Seeder/Fertilizer. Caution: Carefully read all Rules and Instructions for Safe Operation.

Model Assembly & Operating Instructions

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

Gypsy Statement of Limited Warranty. Part 1 General Terms

THANK YOU FOR PURCHASING OUR STUDIO RTA CREATION STATION

Single-Sliding Header Mount INSTALLATION INSTRUCTIONS

All Purpose Hardware

COMPETITOR WM-203 COMBO BENCH

FP-4855 Flat Panel Television Stand ASSEMBLY INSTRUCTIONS

Aquatic Specialties Manufacturing. Cover Butler Installation & Use Manual

Assembly Instructions and Owner s Manual Flex TechBridge

GT Series Grooving Tool

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

INSTALLATION SUGGESTIONS LEVEL APPLICATION LIMITED WARRANTY

Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.

MARCY CLASSIC MCB-252 COMBO BENCH W/120 lbs Weight Set

ImPortant InformatIon. Parts IdentIfIcatIon. Assembly Instructions for Model Number 138T-BK

Transcription:

Single Flex and Double Flex Couplings (i) FORM NO. L00G00

In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject to change without notice. Technical data listed in this manual are based on the latest information available at the time of printing and are also subject to change without notice. Technical Support: 0037 () 900 www.nexengroup.com DANGER Read this manual carefully before installation and operation. Follow Nexen's instructions and integrate this unit into your system with care. This unit should be installed, operated and maintained by qualified personnel ONLY. Improper installation can damage your system or cause injury or death. Comply with all applicable codes. Nexen Group, Inc. 0 Oak Grove Parkway Vadnais Heights, Minnesota 7 ISO 900 Certified Copyright 999 Nexen Group, Inc. (ii)

Table of Contents INTRODUCTION INSTALLATION REPLACEMENT PARTS PARTS LIST WARRANTY 7 (iii)

INTRODUCTION Nexen's Single and Double Flex, universally designed couplings combine with Nexen's Open or Enclosed H and H Series Clutches and Torque Limiters. The Open H Series Tooth Clutches have four mounting holes; the Enclosed H and H Series and Torque Limiters have six mounting holes. Use the four standard cap screws when combining the Coupling with the H and H Series Tooth Clutch. Use the six stainless steel cap screws when combining the Coupling with the Enclosed Nickelplated H and H Series Tooth Clutch or Torque Limiters. INSTALLATION SINGLE FLEX COUPLING 3 Customer supplied taper lock bushing and key FIGURE Torque Limiter, H Series Clutch, or H Series Tooth Clutch TABLE SINGLE FLEX COUPLING ADAPTER ASSEMBLY MODEL Coupling Adapter Assembly Adaptor Assembly Misalignment Capacity Misalignment Capacity ANG. AXIAL PARA S.H.C.S. Clamping Torque (Item ) (Qty ) Open Units Only S.H.C.S. Clamping Torque (Item ) (Qty ) Enclosed Units Only Hex. Nut Clamping Torque (Item ) Clamping Torque H30, H30, TL0 90990. Deg.. 0. 0 In. Lbs. 0 In. Lbs. 0 In. Lbs. H3, H3, TL30 9000. Deg.. 070. 0 In. Lbs. 0 In. Lbs. In. Lbs. H0, H0 900. Deg.. 00. 03 In. Lbs. 0 In. Lbs. In. Lbs. H, H, TL0 900. Deg.. 090. 0 In. Lbs. In. Lbs. 33 In. Lbs. H0, H0, TL0 9030. Deg.. 0. 07 300 In. Lbs. 07 In. Lbs. 33 In. Lbs. H0, H0, TL0 900. Deg.. 0. 09 300 In. Lbs. 07 In. Lbs. 9 In. Lbs. H70, H70, TL70 900. Deg.. 3. 0 30 In. Lbs. 70 In. Lbs. 90 In. Lbs. H0, TL0 97 0. Deg... 0 30 In. Lbs. 70 In. Lbs. In. Lbs. If parallel, angular, and axial misalignment are all required, make sure the combined percentage of each does not exceed 00%. EXAMPLE: If 00% of the parallel misalignment is required, no angular or axial misalignment is allowed. If 0% of the parallel misalignment is required, only 0.7 degrees angular misalignment or 0% or the axial rating will be available. FORM NO. L00G00

. Insert the taper lock bushing into the Coupling Hub (Item ) (See Figure ).. Slide the Coupling Hub (Item ) with the customer supplied taper lock bushing and key onto one shaft, then install the set screws provided with the taper lock bushing (See Figure ). Make sure there are no burrs on the shafts or keys. Do not tighten the set screws provided with the taper lock bushing at this time. 3. Using the Socket Head Cap Screws (Item ), attach the Coupling Adapter (Item ) to the Clutch or Torque Limiter (See Figure ).. Tighten the Socket Head Cap Screws (Item ) to the recommended torque (See Table ).. Slide the Coupling Adapter with the Clutch or Torque Limiter onto the other shaft (See Figure ).. Tighten the taper lock bushing set screws to the recommended torque. 7. Adjust the hub separation to within the limits for parallel and angular misalignment (See Table ). For best results, Nexen recommends the use of a dial indicator when checking the limits for parallel and angular misalignment. To ensure accurate readings, always rotate the hub on which the dial indicator probe is mounted. CAUTION Coupling and shaft alignment should be checked periodically, due to equipment shifting, etc. Alignment should be rechecked after the first forty hours of operation.. Secure the Clutch or Torque Limiter with the Coupling Adapter to the shaft according to the instructions provided with the Clutch or Torque Limiter. 9. Insert the Disc Pack (Item 3) between the Coupling Adapter (Item ) and the Coupling Hub (Item ) (See Figure ). 0. Using Hex. Head Cap Screws (Item ) and Hex. Nuts (Item ), secure the Disc Pack (Item 3) to the Coupling Adapter (Item ) and the Coupling Hub (Item ). To prevent galling or seizing, check the Hex. Nuts (Item ) for lubricant. If lubricant is not found on Hex. Nut, apply Molycote or equivalent lubricant to the Hex. Head Cap Screws (Item ) to ensure proper clamping torque. Do not rotate Hex. Head Cap Screws (Item ) while applying clamping torque.. Alternately and evenly tighten the Hex. Nuts (Item ) to onehalf of the recommended torque (See Table ).. Alternately and evenly tighten the Hex. Nuts (Item ) to the recommended torque (See Table ). FORM NO. L00G00

DOUBLE FLEX COUPLING Customer supplied taper lock bushing and key 7 3 FIGURE 3 Torque Limiter, H Series Clutch, or H Series Tooth Clutch TABLE MODEL Coupling Adapter Assembly Adaptor Assembly DOUBLE FLEX COUPLING ADAPTER ASSEMBLY Misalignment Capacity Misalignment Capacity ANG. AXIAL PARA S.H.C.S. Clamping Torque (Item ) (Qty ) Open Units Only S.H.C.S. Clamping Torque (Item ) (Qty ) Enclosed Units Only Hex. Nut Clamping Torque (Item ) Clamping Torque H30, H30, TL0 9099 0.3 0.03 In. Lbs. 0 In. Lbs. 0 In. Lbs. H3, H3, TL30 900 0. 0.07 In. Lbs. 0 In. Lbs. In. Lbs. H0, H0 90 0. 0.0 In. Lbs. 0 In. Lbs. In. Lbs. H, H, TL0 90 0. 0.09 In. Lbs. In. Lbs. 33 In. Lbs. H0, H0, TL0 903 0. 0.0 300 In. Lbs. 07 In. Lbs. 33 In. Lbs. H0, H0, TL0 90 0. 0.7 300 In. Lbs. 07 In. Lbs. 9 In. Lbs. H70, H70, TL70 90 0.7 0.37 30 In. Lbs. 70 In. Lbs. 90 In. Lbs. H0, TL0 97 0.3 0.70 30 In. Lbs. 70 In. Lbs. In. Lbs. If parallel, angular, and axial misalignment are all required, make sure the combined percentage of each does not exceed 00%. EXAMPLE: If 00% of the parallel misalignment is required, no angular or axial misalignment is allowed. If 0% of the parallel misalignment is required, only. degrees angular misalignment or 0% or the axial rating will be available.. Insert the taper lock bushing into the Coupling Hub (Item ) (See Figure ).. Slide the Coupling Hub (Item ) with the customer supplied taper lock bushing and key onto one shaft, then install the set screws provided with the taper lock bushing (See Figure ). Make sure there are no burrs on the shafts or keys. Do not tighten the set screws provided with the taper lock bushing at this time. 3. Using the Socket Head Cap Screws (Item ), attach the Coupling Adapter (Item ) to the Clutch or Torque Limiter (See Figure ).. Tighten the Socket Head Cap Screws (Item ) to the recommended torque (See Table ).. Slide the Coupling Adapter with the Clutch or Torque Limiter onto the other shaft (See Figure ).. Tighten the taper lock bushing set screws to the recommended torque. 7. Adjust the hub separation to within the limits for parallel and angular misalignment (See Table ). For best results, Nexen recommends the use of a dial indicator when checking the limits for parallel and angular misalignment. To ensure accurate readings, always rotate the hub on which the dial indicator probe is mounted. CAUTION Coupling and shaft alignment should be checked periodically, due to equipment shifting, etc. Alignment should be rechecked after the first forty hours of operation.. Secure the Clutch or Torque Limiter with the Coupling Adapter to the shaft according to the instructions provided with the Clutch or Torque Limiter. FORM NO. L00G00 3

9. Using Hex. Head Cap Screws (Item ) and Hex. Nuts (Item ), secure the Disc Packs (Item 3) to the Flange (Item 7) (See Figure ). To prevent galling or seizing, check the Hex. Nuts (Item ) for lubricant. If lubricant is not found on Hex. Nut, apply Molycote or equivalent lubricant to the Hex. Head Cap Screws (Item ) to ensure proper clamping torque. Do not rotate Hex. Head Cap Screws (Item ) while applying clamping torque. 0. Alternately and evenly tighten the Hex. Nuts (Item ) to onehalf of the recommended torque (See Table ).. Alternately and evenly tighten the Hex. Nuts (Item ) to the recommended torque (See Table ). 3. Using Hex. Head Cap Screws (Item ) and Hex. Nuts (Item ), secure the Disc Pack and Flange Assembly to the Coupling Adapter (Item ) and Coupling Hub (Item ) (See Figure ). To prevent galling or seizing, check the Hex. Nuts (Item ) for lubricant. If lubricant is not found on Hex. Nut, apply Molycote or equivalent lubricant to the Hex. Head Cap Screws (Item ) to ensure proper clamping torque. Do not rotate Hex. Head Cap Screws (Item ) while applying clamping torque.. Alternately and evenly tighten the Hex. Nuts (Item ) to onehalf of the recommended torque (See Table ).. Alternately and evenly tighten the Hex. Nuts (Item ) to the recommended torque (See Table ).. Insert the Disc Pack and Flange Assembly between the Coupling Adapter (Item ) and the Coupling Hub (Item ) (See Figure ). REPLACEMENT PARTS The item or balloon number for all Nexen products is used for part identification on all product parts lists, product price lists, unit assembly drawings, bills of materials, and instruction manuals. When ordering replacement parts, specify model designation, item number, part description, and quantity. Purchase replacement parts through your local Nexen Distributor. FORM NO. L00G00

PARTS LIST SINGLE FLEX COUPLING 3 FIGURE 3 9 SINGLE FLEX COUPLING ITEM DESCRIPTION Coupling Adapter 90990 9000 900 QUANTITY 900 9030 900 900 970 Socket Head Cap Screw (Open Units) Socket Head Cap Screw (Stainless, Enclosed Units) 3 Disc Pack (Flexible) Coupling Hub Hex. Head Cap Screw Hex. Nut (Torque) 9 Hex Head Cap Screw FORM NO. L00G00

DOUBLE FLEX COUPLING 7 FIGURE 3 9 3 SINGLE FLEX COUPLING ITEM DESCRIPTION Coupling Adapter 9099 900 90 QUANTITY 90 903 90 90 97 Socket Head Cap Screw (Open Units) Socket Head Cap Screw (Stainless, Enclosed Units) 3 Disc Pack (Flexible) Coupling Hub Hex. Head Cap Screw Hex. Nut (Torque) 7 Flange Double Flex Hex Head Cap Screw 9 Hex Head Cap Screw FORM NO. L00G00

WARRANTY Warranties Nexen warrants that the Products will be free from any defects in material or workmanship for a period of months from the date of shipment. NEXEN MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. This warranty applies only if (a) the Product has been installed, used and maintained in accordance with any applicable Nexen installation or maintenance manual for the Product; (b) the alleged defect is not attributable to normal wear and tear; (c) the Product has not been altered, misused or used for purposes other than those for which it was intended; and (d) Buyer has given written notice of the alleged defect to Nexen, and delivered the allegedly defective Product to Nexen, within one year of the date of shipment. Exclusive Remedy The exclusive remedy of the Buyer for any breach of the warranties set out above will be, at the sole discretion of Nexen, a repair or replacement with new, serviceably used or reconditioned Product, or issuance of credit in the amount of the purchase price paid to Nexen by the Buyer for the Products. Limitation of Nexen s Liability TO THE EXTENT PERMITTED BY LAW NEXEN SHALL HAVE NO LIABILITY TO BUYER OR ANY OTHER PERSON FOR INCIDENTAL DAMAGES, SPECIAL DAMAGES, CONSEQUENTIAL DAMAGES OR OTHER DAMAGES OF ANY KIND OR NATURE WHATSOEVER, WHETHER ARISING OUT OF BREACH OF WARRANTY OR OTHER BREACH OF CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE, EVEN IF NEXEN SHALL HAVE BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH POTENTIAL LOSS OR DAMAGE. For all of the purposes hereof, the term consequential damages shall include lost profits, penalties, delay images, liquidated damages or other damages and liabilities which Buyer shall be obligated to pay or which Buyer may incur based upon, related to or arising out of its contracts with its customers or other third parties. In no event shall Nexen be liable for any amount of damages in excess of amounts paid by Buyer for Products or services as to which a breach of contract has been determined to exist. The parties expressly agree that the price for the Products and the services was determined in consideration of the limitation on damages set forth herein and such limitation has been specifically bargained for and constitutes an agreed allocation of risk which shall survive the determination of any court of competent jurisdiction that any remedy herein fails of its essential purpose. Limitation of Damages In no event shall Nexen be liable for any consequential, indirect, incidental, or special damages of any nature whatsoever, including without limitation, lost profits arising from the sale or use of the Products. Warranty Claim Procedures To make a claim under this warranty, the claimant must give written notice of the alleged defect to whom the Product was purchased from and deliver the Product to same within one year of the date on which the alleged defect first became apparent. Nexen Group, Inc. 0 Oak Grove Parkway Vadnais Heights, MN 7 00.3.7 Fax:..099 www.nexengroup.com ISO 900 Certified FORM NO. L00G00 7