DIGITAL ILLUMINANCE METER MODEL 1308 INSTRUCTION MANUL

Similar documents
Manual DATALOGGING LIGHT METER - PCE-174

DIGITAL LIGHT METER TES-1337 INSTRUCTION MANUAL CONTENTS

Model ST Instruction Manual. Light Meter. reedinstruments www.

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

INSTRUCTION MANUAL PCE-222

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

EasyView Light Meter with Memory

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

User Guide. EasyView Digital Light Meter. Model EA31

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

DIGITAL MULTIMETER OPERATOR S MANUAL

LIGHT INTENSITY METER

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

Model Digital Light Meter

LUX/FC LED Light Meter TM-201L / TM-209 User s manual

LUX/FC LED Light Meter TM-201L / TM-209/TM-209N /TM-209M

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

Dawson DSM150. Digital Light Meter User s Manual

3423 LUX HiTESTER INSTRUCTION MANUAL

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Advanced Test Equipment Rentals ATEC (2832)

Heavy Duty Meter Model

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Cat# Multi-functional LED Light Meter

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Colour Meter PCE-TCR 200 Instruction Manual

Product Specification

Contents. Ⅰ. General. Ⅱ. Open-package Inspection. Ⅲ. Safety Note. Warning:

MW3105 DIGITAL CLAMP MULTIMETER

QUANTUM PHOTO-METER LX OPERATING INSTRUCTIONS. ... Three decimal points only displayed Overrange reading. Adjust Range. ( X 1000will light up)

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

400Amp True RMS AC/DC Clamp Meter Model EX613

312, 316, 318. Clamp Meter. Users Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Model S471-LED Optometer

MAVOLUX 5032C/B Digital Luxmeter

Digital Multi Meter OPERATING INSTRUCTION. Table of Contents

Nuclear Associates Precision Photometer

600A Clamp Meters w/tightsight Display

DVM1190 DIGITAL MULTIMETER

EM5. Multifunctional Environmental Meter. Sealed Unit Parts Co., Inc. User Manual

Pen-type DIGITAL MULTITESTER

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

ET-3888 True RMS Clamp Meter. User Manual

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

OPERATOR S INSTRUCTION MANUAL

BENNING. CM7 Electrical Tester. Service Information

DIGITAL OXYGEN METER. Model : DO-5510

DM-45 Digital Multimeter

MODEL: D03128 CLAMP METER

DIGITAL MULTIMETER AUTORANGING

AC Clamp Meter + Phase Rotation Tester

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

770E DIGITAL MULTIMETER OPERATOR S MANUAL

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Illuminance Meter. series

BENCH METER Model>9803. Wavecom Instruments

INSTRUCTION MANUAL DIGITAL MULTIMETER

LCT COUNTING SCALE INSTRUCTION MANUAL

400Amp True RMS AC Clamp Meter + NCV

NEW PRODUC T BULLE TIN RADIO PARTS GROUP

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

DM-46 Instruction Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Sound Level Meter C.A 832

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

OPERATOR S INSTRUCTION MANUAL

MS6612T Multi-functional Light Meter USER MANUAL

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

DIGITAL MULTIMETER OPERATION MANUAL

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

4-in-1 Humidity, Temperature Airflow and Light Meter

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

SAFETY PRECAUTIONS: Before use, read the following safety precautions

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

200Amp AC Clamp Meter + NCV Model MA250

1. GENERAL INSTRUCTIONS Precaution safety measures Preliminary During use Symbols Instructions 4

Transcription:

DIGITAL ILLUMINANCE METER MODEL 1308 INSTRUCTION MANUL

Ⅰ INSTRUCTION The digital illuminance meter is a precision instrument used to measure illuminance (lux, footcandle) in the field. It is meet CIE photopic spectral response. It is fully cosine corrected for the angular incidence of light. The illuminance meter is compact, tough and easy to handle owing to its constrution. The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral response filter. Ⅱ FEATURES Light-measuring levels ranging form 0.01lux~0.1klux/0.01fc~0.01kfc,repeatedly. High accuracy and rapid response. Data-hold function for holding measuring values. Unit and sign display for easy reading. Automatic zeroing. Meter corrected for spectral relative efficiency. Correction factor need not be manually calculated for 2

non-standard light sources. Short rise and fall times. Peak-hold function for tracing the peak signal of light pulse with least duration 10µs and keep it. Capable of selecting measuring mode in lux or fc scale alternatively. Auto power off 30 minutes. Maximum and minimum measurements. Relative reading & Reset function. Easy to read large backlit display Ⅲ SPECIFICATIONS Display :3-3/4 digit LCD with high speed 42 segment bargraph. Measuring Range:40.00 lux,400.0 lux,4000 lux,40.00 Klux and 300.0 Klux /40.00 fc,400.0 fc,4000 fc,30.00 Kfc. NOTE: 1fc=10.76lux,1Klux=1000lux,1Kfc=1000fc Overrange Display: LCD will show OL symbol. Spectral Response: CIE Photopic. (CIE human eye response curve). Spectral Accuracy: CIE Vλ function f1 6% 3

Cosine Response: f2 2% Accuracy: ±5% rdg±0.5% f.s. Repeatability: ±3% Sampling Rate: 13.3 times/sec of analog bar-graph indication;1.3times/sec of digital display. Photo Detector: One silicon photo diode and spectral response filter. Operating temperature & Humidity : 0 to 40 (32 to 104 ) & 0% to 80% RH. Storage Temperature & Humidity : -10 to 50 (14 to 140 ) & 0% to 70% RH. Power Source: 1 piece 9V battery. Photo detector Lead Length: 150cm (approx.); Photo detector Dimensions: 115L 60W 20H(mm); Meter Dimensions: 170L 80W 40H; Weight: 390g. Accessories: Carry case, instruction manual, battery. 4

Ⅳ NAME OF PARTS AND POSITIONS 1 2 3 4 5 6 7 8 9 10 11 12 1. LCD Display: 3-3/4 digit displays with a maximum reading of 3999,and the indicating signs of measured values, unit function symbols and decimal points etc are display. 2. Range Selector key: It indicates 40.00 lux, 400.0 lux,4000 lux,40.00 Klux and 300.0 Klux /40.00 fc,400.0 fc,4000 fc,30.00 Kfc total 5 ranges for lux and 4 ranges 5

for fc. 3. Power Control key: The power switch key turns the illuminance meter ON or OFF. 4. MAX/MIN key: Maximum and minimum reading recorder control key. 5. RESET key: Push function reset control key. 6. BACK-LIGHT key: Back light control key. 7. REL key: Relative reading control key. 8. Data-Hold key: Data Hold control key. 9. Peak Hold key: Peak Hold recorder control key. 10. Lux key: Pressing the lux key selects taking measurement of illuminance in lux scale 11. FC key: Pressing the fc key selects taking measurement of illuminance in footcandle scale; and,1footcandle=10.76lux. 12. Photo detector. Ⅴ OPERATING INSTRUCTIONS 1. Power-up: Press the power key to turn the meter ON or OFF. 2. Selecting the lux or fc scale: Set the range selection switch to desired lux or fc range. 6

3. Remove the photo detector cap and face it light source in a horizontal position. 4. read the illuminance nominal from the LCD display. 5. Overrange: If the instrument only displays OL, the input signal is too strong, and a higher range should be selected. 6. Data-Hold mode: Press the hold key to select Data-Hold mode. When HOLD mode is selected, the illuminance meter stops all further measurements. Press the HOLD key again to exit Data-Hold mode. Then it resumes normal operation. 7. Peak-Hold recorder mode: Press and hold down PEAK key until display shown the CAL letter, then press PEAK key cycle through Pmax and Pmin recorder mode, and expose the photo detector to light pulse measuring field. Press and hold down PEAK key 2 seconds to exit PEAK recorder mode, then the meter will resume normal operation. 8. Maximum and Minimum recorder mode: Press MAX/MIN key to cycle through Maximum(MAX) reading, Minimum(MIN) reading and current reading(max/min blink) recorder mode. Press MAX/MIN key two seconds 7

to exit this mode. 9. Relative reading mode: Press REL key to enter Relative mode. The display shown zero value and the current reading will be stored as a zero-in value. Press again to exit this mode. 10. Reset mode: Every time when this key is pressed the pushed function(hold,max/min,rel,peak except BACK-LIGHT),auto-power-off function and counter will be reset. 11. Back-light function: Press the Backlight key to turn on. Press again to turn off. 12. When the measurement is completed, replace the photo detector cap and turn the meter off. Ⅵ BATTERY CHECK-UP & REPLACEMENT 1. As the battery power is not sufficient, LCD will display low battery, and replacement of one new battery is required. 2. After turning off the meter, disconnect the battery cover with a screwier. 3. Disconnect the battery from the instrument and replace it with a standard 9V battery and go for the cover. 8

Ⅶ SPECTRAL SENSITIVITY CHARACTERISTIC To the detector, the applied photo diode with filters makes the spectral sensitivity characteristic almost meet C.I.E.(INTERNATIONAL COMMISSION ON ILLUMINATION) Photopic curve V (λ) as the following chart described. Ⅷ MAINTENANCE 1. The white plastic disc on the top of the detector should be cleaned with a damp cloth when necessary. 2. Do not store the instrument where temperature or humidity is excessively high. 3. The reference level, as marker on the face plate, is the tip of the photo detector globe. 4. The calibration interval for the photo detector will vary according to operational conditions, but generally the 9

sensitivity decreases in direct proportion to the product of luminous intensity by the operational time. In order to maintain the basic accuracy of the instrument, periodic calibration is recommended. Ⅸ RECOMMENDED ILLUMINATION 1fc=10.76Lux LOCATIONS Lux fc OFFICE Conference,Recepti 200~750 18~70 on room Clerical work 700~1,500 65~140 Typing drafting 1,000~2,000 93~186 FACTORY Visual work at 300~750 28~70 production line Inspection work 750~1,500 70~140 Electronic parts 1,500~3,000 140~279 assembly line Packing work, 150~300 14~28 Entrance passage HOTEL Public room, 100~200 9~18 Cloakroom Reception 200~500 18~47 10

STORE HOSPITAL SCHOOL Cashier 750~1,000 70~93 Indoors Stairs 150~200 14~18 Corridor Show window, 750~1,500 70~140 Packing table Forefront of show 1,500~3,000 140~279 window Sickroom, 100~200 9~18 Warehouse Medical Examination 300~750 28~70 Room Operating room, 750~1,500 70~140 emergency treatment Auditorium,Indoor 100~300 9~28 Gymnasium Class room 200~750 18~70 Laboratory, Library, 500~1,500 47~140 Drafting, room 11