AN4875 Application note

Similar documents
STEVAL-XPLM01CPL. Power line communication AC coupling circuit. Description. Features

AN4392 Application note

AN4949 Application note

AN5029 Application note

AN4378 Application note

AN5008 Application note

AN5009 Application note

76-81GHz MMIC transceiver (4 RX / 3 TX) for automotive radar applications. Table 1. Device summary. Order code Package Packing

ESDLIN03-1BWY. Automotive single-line Transil, transient voltage suppressor (TVS) for LIN bus. Application. Description. Features

AN4819 Application note

TS3022. Rail-to-rail 1.8 V high-speed dual comparator. Applications. Description. Features

ESDARF02-1BU2CK. Single-line bidirectional ESD protection for high speed interface. Features. Applications. Description

AN5258. Extending output performance of ST ultrasound pulsers. Application note. Introduction

Automotive dual-line Transil, transient voltage suppressor (TVS) for CAN bus

LM2904AH. Low-power, dual operational amplifier. Related products. Description. Features. See LM2904WH for enhanced ESD performances

CBTVS2A16-1F3. Circuit breaker with transient voltage suppressor. Description. Features. Complies with the following standards:

DN0039 Design note. 35 W wide input range flyback converter using HVLED001A quasi resonant Flyback controller and STF10LN80K5.

DSL04. Low capacitance TVS for high speed lines such as xdsl. Description. Features. Complies with the following standards

RT2904WH. RobuST low-power dual operational amplifier. Applications. Features. Description

ESDCAN03-2BWY. Automotive dual-line Transil, transient voltage suppressor (TVS) for CAN bus. Application. Description. Features

Description. consumption lower than 1 µa. The device also Input voltage from 2.4 to 5.5 V

Description. Table 1. Device summary. Order code Package Packing. TDA7851F Flexiwatt25 (vertical) Tube TDA7851FH-QIX Flexiwatt25 (horizontal) Tube

TSV611, TSV611A, TSV612, TSV612A

TSC1021. High-side current sense amplifier. Related products. Applications. Features. Description

Description. Table 1: Device summary Order code Package Packing STWLC33JR CSP (3.97x2.67 mm) 400 μm pitch 52 balls Tape and reel

Low-power, 2.5 MHz, RR IO, 36 V BiCMOS operational amplifier. Description

TS3011. Rail-to-rail high-speed comparator. Applications. Description. Features

STPS1045HR. Aerospace 2 x 10 A - 45 V Schottky rectifier. Description. Features

TSB611. Low-power, rail-to-rail output, 36 V operational amplifier. Applications

ESDCAN01-2BLY, ESDCAN24-2BLY

ESDALC6V1-5M6. 5-line low capacitance Transil arrays for ESD protection ESDALC6V1-5M6. Applications. Description. Features

LD3985. Ultra low drop and low noise BiCMOS voltage regulators. Features. Description

ECMF2-0730V12M12. Common mode filter with ESD protection for USB2.0 interface. Applications. Description. Features. Complies with following standards

ST1S A, 1.5 MHz adjustable, step-down switching regulator. Description. Features

TSM1013. Constant voltage and constant current controller for battery chargers and adapters. Description. Features. Applications

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

TS4061. Precision micropower shunt voltage reference. Description. Features. Applications

AN4781 Application note

AN4999 Application note

Features. Description. Table 1. Device summary. Quality level. Package I F (AV) V RRM T j (max) V F (max) Engineering model TO x

Low consumption voltage and current controller for battery chargers and adapters. Description. Table 1. Order codes. Package D (1) V ref (%) Marking

AN4995 Application note

UM1082 User manual. The STPM10 single-phase meter evaluation boards. Introduction

AN3218 Application note

Features. Description. Table 1. Device summary. Order code Marking Package Packaging. STF100N6F7 100N6F7 TO-220FP Tube

LD39130S. 300 ma very low quiescent current linear regulator IC with the automatic green mode. Applications. Description. Features

DSL05. Secondary protection for VDSL2 and G.FAST lines. Description. Features I/O1 -V LD +V LD I/O2

ESDARF01-1BF4. ESD protection for AM and FM antenna. Features. Applications. Description. Complies with the following standards

CPL-WBF-00D3. Wide band directional coupler with ISO port. Description. Features. Benefits. Applications

BALF-NRG-01D3. 50 Ω nominal input / conjugate match balun to BlueNRG transceiver, with integrated harmonic filter. Description. Features.

BAL-NRF02D3. 50 ohm nominal input / conjugate match balun to nrf51822-ceaa and nrf51422-ceaa. Features. Applications. Description.

Automotive Transil, transient voltage suppressor (TVS) for LIN bus. Description

AN3213 Application note

MLPF-WB55-01E GHz low pass filter matched to STM32WB55Cx/Rx. Datasheet. Features. Applications. Description

150 ma low quiescent current and low noise voltage regulator. Description

AN4327 Application note

N-channel 60 V, Ω typ., 20 A STripFET F7 Power MOSFET in a PowerFLAT 3.3x3.3 package. Features. Description. AM15810v1

ECMF02-2BF3. Dual line IPAD, common mode filter with ESD protection for high speed serial interface. Description. Features.

50 ohm nominal input / conjugate match balun to nrf CEAA/CDAB/CFAC and nrf51422-ceaa/cdab/cfac. Description

STBR3012. High voltage rectifier for bridge applications

RT2902. RobuST low-power quad operational amplifier. Applications. Description. Features

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

STEVAL-ISA192V1. 7 W dual output flyback converter with standby managed by capacitive touch using VIPer0P and STM32L. Description.

I-NUCLEO-SX1272D. SX1272 LoRa technology and high-performance FSK/OOK RF transceiver modem. Features

TSX339. Micropower quad CMOS voltage comparators. Related products. Applications. Description. Features

Description. Table 1. Device summary. Order codes Output voltage

Features. Description. Table 1: Device summary Order code Marking Package Packing STF140N6F7 140N6F7 TO-220FP Tube

ESD051-1BF4. 5 V low clamping single line bidirectional ESD protection. Datasheet. Features. Application. Description

STP4CMP. Low voltage 4-channel constant current LED driver with charge pump. Description. Features. Applications

LDP01-xxAY. Automotive TVS for load dump protection. Description. Features. Complies with the following standards:

LCP154DJF. Programmable transient voltage suppressor for SLIC protection. Description. Features. Benefits

AN4876 Application note

BAT30. Small signal Schottky diodes. Description. Features

SM6T250CAY. Automotive 600 W Transil. Description. Features. Complies with the following standards

TS3021H. Automotive rail-to-rail 1.8 V high-speed comparator. Related products. Applications. Description. Features SOT23-5

ESD051-1F4. Low clamping single line unidirectional ESD. Datasheet. Features. Application. Description

STPSC6H V power Schottky silicon carbide diode. Description. Features

N-channel 30 V, 2.5 mω typ., 120 A STripFET H6 Power MOSFET in a TO-220 package. Features. Description

Conducted emission pre compliance measurements

TEST REPORT... 1 CONTENT...

TSX3702. Micropower dual CMOS voltage comparators. Related products. Applications. Description. Features

ESDALCL6-4P6A. Multi-line low capacitance and low leakage current ESD protection. Features. Applications. Description

Description. Table 1. Device summary. Order codes. SOT23-5L Marking SOT323-5L Marking DFN8 (3x3 mm) Marking

STEVAL-SMACH15V1. 15 W 5 V output USB adapter evaluation board with STCH03 CC-mode primary sensing switching controller. Data brief.

STIEC45-xxAS, STIEC45-xxACS

STPS160H100TV. High voltage power Schottky rectifier. Description. Features

PM8841D. 1 A low-side gate driver. Description. Features. Applications

EVAL6235N. Demonstration board for L6235 DMOS driver for 3-phase brushless DC motor. Description. Features

ULQ2801, ULQ2802, ULQ2803, ULQ2804

AS11P2TLR. Low voltage 1 Ω single-pole double-throw analog switch with breakbefore-make. Description. Features

ALTAIR05T W wide range CV-CC optoless adapter evaluation board

LDL A high PSRR low-dropout linear voltage regulator. Applications. Description. Features

SMM4FxxA. 400 W Transil TM. Description. Features. Complies with the following standards

300 ma very low quiescent current linear regulator IC with automatic green mode

STPS3170. Power Schottky rectifier. Description. Features

STGB20NC60V, STGP20NC60V, STGW20NC60V

AN5129 Application note

LD ma very low quiescent current linear regulator IC. applications. Description. Features

50 Ω nominal input / conjugate match balun to nrf51422-qfaa, nrf24le1, nrf51822-qfaa/ab, with integrated harmonic filter

Transcription:

Application note STCOMET smart meter and power line communication system-on-chip G3-PLC characterization Riccardo Fiorelli and Patrick Guyard Introduction This document is aimed at describing the electrical characteristics and communication performance of a power line communication (PLC) node based on the EVLKSTCOMET10-1 hardware and G3-PLC firmware operating in the CENELEC A frequency band (9-95 khz). The EVLKSTCOMET10-1 is a development kit for the STCOMET platform, exploiting the performance capability of the full-featured STCOMET10 device. The STCOMET10 is a single device integrating a flexible power line communication (PLC) modem with a fully embedded analog front-end (AFE) and a line driver, a high performance 3-channel metrology function and a Cortex -M4 application core. Compliance test results are reported for electromagnetic compatibility (EMC) applicable standards, along with transmission and reception characterization measurements. Please check for the EVLKSTCOMET10-1 hardware documentation, evaluation software and firmware libraries at st.com/powerline. For specific software or firmware releases, you may need to contact directly the STMicroelectronics sales office. Figure 1: STCOMET development kit - EVLKSTCOMET10-1 June 2016 DocID029338 Rev 1 1/42 www.st.com

Contents Contents AN4875 1 Safety recommendations... 4 2 STCOMET smart meter and power line communication system-on-chip description... 5 3 Test equipment... 6 4 Power supply characteristics... 7 4.1 Three DC input supply requirements (J13)... 7 4.2 Single DC input supply requirements (J7)... 8 5 Power line characteristics... 9 5.1 Line coupling characteristics... 9 6 Transmitter characteristics... 10 6.1 Test setup... 10 6.2 Transmitter output voltage... 11 6.2.1 VCC = 15 V... 11 6.2.2 8 V VCC 18 V... 12 6.3 Line coupling insertion loss... 13 6.4 Output power... 14 6.5 TX digital gain... 15 7 Receiver characteristics... 16 7.1 Reception filter characteristics... 16 7.2 Receiver sensitivity test setup... 17 7.3 Input noise level... 17 7.4 Sensitivity level... 20 8 EN50065 compliance tests... 22 8.1 EN50065-1: General requirements, frequency bands and electromagnetic disturbances... 23 8.1.1 Test setup... 23 8.1.2 Determination of the bandwidth (EN50065-1 section 6.2.1)... 25 8.1.3 Determination of output level (EN50065-1 section 6.2.2)... 25 8.1.4 Maximum output levels - sub-band above 9 khz up to 95 khz (EN50065-1 section 6.3.1.2)... 26 8.1.5 Disturbance limits - application outside sub-bands (EN50065-1 section 7.1)... 28 8.1.6 Conducted disturbance - frequency range from 3 khz to 9 khz (EN50065-1 section 7.2.1)... 29 2/42 DocID029338 Rev 1

Contents 8.1.7 Conducted disturbance - frequency range from 9 khz to 150 khz (EN50065-1 section7.2.2)... 31 8.1.8 Conducted disturbance - frequency range from 150 khz to 30 MHz (EN50065-1 section 7.2.3)... 33 8.1.9 Radiated disturbance field strength (EN50065-1 section 7.3)... 35 8.2 EN50065-2-3: immunity requirements... 36 8.2.1 Electrical Fast Transients (EFT) and Surge Immunity... 36 8.3 EN50065-7: equipment impedance... 37 9 References... 39 10 Normative references... 40 11 Revision history... 41 DocID029338 Rev 1 3/42

Safety recommendations AN4875 1 Safety recommendations The STCOMET development kit must be used by expert technicians only. Due to the high voltage (85-265 V ac) present on the non-isolated parts, special care must be taken in order to avoid electric risks for people safety. There are no protections against high voltage accidental human contact. After a disconnection of the board from the mains all the live part must not be touched immediately because of the energized capacitors. It is mandatory to use a mains insulation transformer to perform any tests on the high voltage sections, using test instruments like, for instance, spectrum analyzers or oscilloscopes. Do not connect any probe to high voltage sections if the board is not isolated from the mains supply, in order to avoid damaging instruments and demonstration tools. When configured for metering evaluation, the STCOMET development kit is not isolated and ground will be tied to the line. Do NOT connect instrument probes that can bring the earth connection to the line, thus potentially damaging the STCOMET development kit and the instruments and creating electrical risk. STMicroelectronics assumes no responsibility for the consequences of any improper use of this development tool. 4/42 DocID029338 Rev 1

STCOMET smart meter and power line communication system-on-chip description 2 STCOMET smart meter and power line communication system-on-chip description The STCOMET is a device that integrates a narrow-band power line communication (NB- PLC) modem, a high-performance application core and metrology functions. The PLC modem architecture has been designed to target the EN50065, FCC, ARIB compliant PLC applications. Together with the application core, it enables the STCOMET platform to support the PRIME, IEC 61334-5-1, G3-PLC, IEEE 1901.2, METERS AND MORE, and other narrow-band PLC protocol specifications. The metrology sub-system is suitable for the EN 50470-1, EN 50470-3, IEC 62053-21, IEC 62053-22, and IEC 62053-23 compliant class1, class0.5 and class0.2 AC metering applications. For further details, please refer to point 1. in References. Figure 2: STCOMET block diagram DocID029338 Rev 1 5/42

Test equipment AN4875 3 Test equipment The measurements results reported in this document have been obtained using the following instruments: Equipment designation Table 1: Electrical instruments used for testing Equipment reference Purpose Spectrum analyzer Rohde & Schwarz FSU TX and RX signal power measurement Spectrum analyzer Agilent E4443A RX Input noise power measurement Differential active probe Probe control and power module Two-line V-network LISN (x2) Agilent 1141A Agilent 1142A Rohde & Schwarz ENV216 Differential, high impedance, low level signal measurements Agilent 1141A probe supply and control Connecting DUT (STCOMET development kit) to AC mains reference line impedance 50 Ω attenuator Trilithic 2010926004-R Transmitted signal attenuation EMC-EMI filter (x3) Schaffner FN2080-6-06 Mains noise filtering DC power analyzer Agilent N6705A Power supply and current consumption measurement 6/42 DocID029338 Rev 1

Power supply characteristics 4 Power supply characteristics 4.1 Three DC input supply requirements (J13) The connector J13 is the standard connector to be used for STCOMET main board supplying. This connector is designed to couple with the VIPer26H PSU board. The test setup for the measurements performed in this section is described in Figure 4. Parameter Table 2: Electrical characteristics power supply J13 Value Min. Typ. Max. Unit VCC power supply voltage 8 15 18 V - VCC power supply current absorption RX mode VCC power supply current absorption TX mode Notes - 2.1 - ma - - 40 - ma TX with no load - 119 - ma TX over EN50065 AMN - 665 - ma TX over 2 Ω AMN 5 V supply voltage 4.75 5 5.25 V TX over EN50065 AMN 5 V supply current absorption RX mode 5 V supply current absorption TX mode - 60 - ma - - 11 - ma - 3V3 supply voltage - 3.3 - V - 3V3 supply current absorption RX mode 3V3 supply current absorption TX mode 3V3_AUX supply current absorption - 110 - ma - 95 - ma 3V3_AUX current consumption is not included in the 3V3 current. 3V3_AUX current consumption is not included in the 3V3 current. - 30 - ma - The current to be supplied on the VCC is linked to the load connected to the J6 at the mains level. This relation is illustrated in Figure 3. DocID029338 Rev 1 7/42

Power supply characteristics 1000 Figure 3: VCC supply current vs. mains load AN4875 800 1.2 2 Ivcc (ma) 600 400 5 VCC = 15 V 200 51 10 LISN 0 0 200 400 600 800 1000 ILoad (ma rms) AM039910 4.2 Single DC input supply requirements (J7) The connector J7 allows supplying the STCOMET main board with a single power supply for safe usage of the kit. In this mode, the connection to mains is not required while performing electrical tests and software/firmware development. Note that the power consumption in this mode is not optimized. Table 3: Electrical characteristics power supply J7 Value Parameter Notes Min. Typ. Max. Unit 15 V recommended for best Power supply voltage 8-15 V PLC performance Power supply current absorption RX mode Power supply current absorption TX mode - 191 - ma - - 176 - ma TX with no load - 253 - ma TX over EN50065 AMN - 825 - ma TX over 2 Ω AMN 8/42 DocID029338 Rev 1

Power line characteristics 5 Power line characteristics 5.1 Line coupling characteristics Table 4: Line coupling parameters Symbol Parameter Value [typ.] Unit fc Center frequency 61.5 khz Vin Withstanding voltage for surge and burst tests > 4.0 kv DocID029338 Rev 1 9/42

Transmitter characteristics AN4875 6 Transmitter characteristics The voltages and currents in the transmission chain (line driver output, line coupling circuit and line load) vary depending on the load connected at the mains level (J6). This section is illustrating graphically the behavior of those parameters. 6.1 Test setup Transmitter characterization has been performed using the setup illustrated in Figure 4 below. Figure 4: Bench setup for transmission measurements Instruments references are described in Table 1. Low pass filters (Schaffner FN2080-6-06) attenuate noise from mains in the CENELEC-A band. The variable transformer allows changing the mains voltage amplitude. This kind of module generates usually less noise than any AC supply. It is recommended to configure the spectrum analyzer input coupling to DC, otherwise the power measurement for frequency below 50 khz may be wrong. A DC power analyzer is used to supply the STCOMET main board while measuring the current consumption. The STCOMET development kit mains output J6 is either connected to the LISN for the spectrum analysis or to a variable load for the power consumption measurement. 10/42 DocID029338 Rev 1

6.2 Transmitter output voltage Transmitter characteristics 6.2.1 VCC = 15 V The output voltage delivered at STCOMET line driver output (PA1_OUT - PA2_OUT) and at the development kit output (J6) is given in the following figures, according to the load applied at the J6 connector, and with VCC = 15 V (typical value). 132 Figure 5: Transmitter output voltage (dbuv) vs. load current 130 51 V load (dbµv) 128 126 124 LISN 10 5 2 STCOMET LOAD 122 1.2 120 0.1 1 10 100 1000 ILoad (ma rms) 4 Figure 6: Transmitter output voltage (V rms) vs. load current Vload (V) 3 2 51 LISN 10 5 2 STCOMET LOAD 1 0.1 1 10 100 1000 ILoad (marms) 1.2 AM039912 DocID029338 Rev 1 11/42

Transmitter characteristics 30 Figure 7: Transmitter output voltage (V p-p) vs. load current AN4875 LISN V load (V) 20 10 51 10 5 2 STCOMET 1.2 LOAD 0 0.1 1 10 100 1000 ILoad (ma rms) AM039913 6.2.2 8 V VCC 18 V Figure 8 below illustrates the maximum differential output voltage achievable by the STCOMET line driver versus the VCC level, when the STCOMET development kit is connected to a LISN. The goal is to keep enough margin for the power amplifier to have a linear output. Figure 8: STCOMET maximum output voltage vs. VCC supply 35 30 Output voltage (Vpp) 25 20 15 10 LISN 5 0 8 10 12 14 16 18 VCC(V) AM039916 12/42 DocID029338 Rev 1

6.3 Line coupling insertion loss Transmitter characteristics Figure 10 illustrates the difference between the voltage generated by the STCOMET line driver and the voltage applied on the load. Those insertion losses are due to the coupling circuit non-negligible impedance. Figure 9: Coupling circuit on STCOMET development kit C20 TRANSFORMER_1_S2 7 4 PRI L1 470NF 15uH 7447714150 D6 SM6T18CA SIOV1 B72214S0461K101 N_PLC TRANSFORMER_1_S1 D7 SM6T10CA D8 SM6T10CA 10 1 N T1 WE 750510682 OR TDK SRW13EP-X07S002 U L_PLC AM039919 Figure 10: Line coupling loss vs. mains load 16 15 14 12 Voltage loss (V ) 10 8 6 4 10 5 Voltage loss (db) Vpk-pk Vrms db 2 51 LISN 1. 10 0 0 0 100 200 300 400 500 600 700 800 900 1000 ILoad (ma rms ) AM039914 DocID029338 Rev 1 13/42

Transmitter characteristics 6.4 Output power AN4875 Figure 11 below illustrates the relationship between the current into the load connected at the J6 and: The power absorbed from the VCC supply (green trace, right Y-axis), The power delivered by the STCOMET line driver (yellow trace, left Y-axis), The power delivered to the load (pink trace, left Y-axis). Figure 11: TX power vs. load current 4 15 System power (W ) 3 2 1 13 11 9 7 5 3 1 VCC supply power (W ) STCOMET LOAD VCC 0 LISN -1 0 100 200 300 400 500 600 700 800 900 1000 ILoad (ma rms) AM039917 Figure 12 illustrates the efficiency of the STCOMET line driver (yellow trace) according to the load connected at the J6. The pink trace is representing the efficiency of the full TX chain, including the losses in the coupling circuit. 30 Figure 12: Power efficiency vs. load current 25 20 LISN 10 5 (%) 15 51 2 10 1. 2 STCOMET LOAD 5 0 0 100 200 300 400 500 600 700 800 900 1000 ILoad (ma rms) AM039915 14/42 DocID029338 Rev 1

6.5 TX digital gain Transmitter characteristics Figure 13 is illustrating the STCOMET line driver output voltage according to the TX digital gain setting. Please note that the X-axis is reporting decimal values, although the hexadecimal format is used in STCOMET settings. Figure 13: Line driver output voltage vs. TX digital gain 30 140 25 130 Output voltage (V) 20 15 10 120 110 100 Output voltage (dbµv) Vpk-pk Vrms dbµv 5 90 0 80 0 4 8 12 16 20 24 28 32 TX digital gain setting (decimal) AM039918 DocID029338 Rev 1 15/42

Receiver characteristics AN4875 7 Receiver characteristics 7.1 Reception filter characteristics Table 5: Reception filter parameters Symbol Parameter Value [typ.] Unit fc Center frequency 60 khz Q Quality factor 0.54 - BW3dB Band-pass 3-dB bandwidth 110 khz GRX Voltage gain at f = fc -0.45 db Figure 14: RX filter frequency response 16/42 DocID029338 Rev 1

7.2 Receiver sensitivity test setup Receiver characteristics Because of the very low amplitude of the signals measured in this section, the bench setup of Figure 15 has been used in order to perform reliable measurements. Figure 15: Bench setup for receiver sensitivity measurement Instrument references are described in Table 1. One STCOMET development kit is used as a transmitter for sensitivity vs. PER measurements. Its TX digital gain is set to minimum value in order to keep its output signal as low as possible and minimize the effect of the parasitic coupling path through the LISN and power supply connections. Measurements of sensitivity vs. modulation are done according to the following procedure: Set attenuation = 0 db Measure transmitted signal at receiver D.U.T. input (J6) = LIN(0dB0 Increase attenuation until PER = 5% = Att5% Calculate sensitivity = LIN(0dB) - Att5% 7.3 Input noise level Table 6 gives the noise power measured at STCOMET RX_IN inputs, using an Agilent E4443A spectrum analyzer with an integrated low noise amplifier and the 1141A high impedance differential probe. Parameter RX_IN input noise power Table 6: Input noise level Main board Condition standalone Main board PSU included Unit CEN-A 35-95 khz 12.4 31.6 dbµv ARIB STD-T84 35-400 khz 20.5 35.7 dbµv G3-FCC 150-490 khz 15.8 25.4 dbµv DocID029338 Rev 1 17/42

Receiver characteristics AN4875 Figures 16 and 17 come from the following calculation: Noise power (STCOMET) = noise power (measured) noise power (intrinsic probe) Example for CEN-A band: Intrinsic probe noise = 15.0 dbµv (probe shortcut) Measured noise = 16.9 dbµv Result noise = 10 x log (10 17dBμV/10-10 15dBμV/10 ) = 12.4 dbµv Figure 16: Intrinsic probe noise CEN-A band 18/42 DocID029338 Rev 1

Figure 17: Measured noise in CEN-A band Receiver characteristics Comments on reported figures: The noise power measured at STCOMET RX_IN inputs on the standalone main board configuration corresponds to the typical input referred noise of the STCOMET itself. We can deduce that the main board design has a limited impact on the kit sensitivity. The noise level measured is higher when the PSU board is used (as expected). However it is important to notice that, as shown by Figure 18 for the CEN-A band, this noise level is mainly linked to a few spurious tones affecting only specific G3-PLC subcarriers, thus giving a marginal impact on overall sensitivity (see following section). DocID029338 Rev 1 19/42

Receiver characteristics Figure 18: CEN-A input noise level PSU board active AN4875 7.4 Sensitivity level Table 7 reports the minimum input signal level that can be applied to the STCOMET development kit mains connector J6, while guaranteeing a maximum PER ( Packet Error Rate ) of 5%. Parameter Receiver sensitivity (J6 level) Table 7: STCOMET development kit sensitivity vs modulations Condition Main board standalone Main board PSU included Unit ROBO - coherent - PER < 5% 20 23 dbµv ROBO - differential - PER < 5% 20 24 dbµv BPSK - coherent - PER < 5% 23 27 dbµv BPSK - differential - PER < 5% 25 30 dbµv QPSK - coherent - PER < 5% 26 30 dbµv QPSK - differential - PER < 5% 28 32 dbµv 8PSK - coherent - PER < 5% 30 34 dbµv 8PSK - differential - PER < 5% 32 37 dbµv 20/42 DocID029338 Rev 1

Receiver characteristics It is noticeable that the PSU impact on the sensitivity is lower than its impact on the noise level measurement. For example, for ROBO coherent modulation: In Table 6: PSU board increases RX_IN noise level by 19.2 db In Table 7: PSU board decreases sensitivity by 3 db only This is due to G3-PLC OFDM intrinsic signal resilience to SNR variations in the band. Figure 19: PSU impact on input noise level - CEN-A band In Figure 19, we can observe that the noise floor of the trace with the PSU active (yellow) is comparable with the lab PSU (blue trace). This is coherent with the sensitivity difference reported in Table 7 and shows that the noise tones have a limited impact on sensitivity. DocID029338 Rev 1 21/42

EN50065 compliance tests AN4875 8 EN50065 compliance tests Table 8: List of standard tests required for EMC compliance to EN50065 subset related to G3-PLC implementation Basic Type Test Result Notes standard PLC transmission: conducted measurement Conducted disturbance measurements Radiated disturbance measurement Conducted immunity Radiated immunity Input impedance measurement EN 50065-1 EN 50065-1 EN 50065-1, EN 55022 EN 50065-1, EN 55022 EN 61000-4-6 EN 50065-2-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-3 EN50065-7 Bandwidth measurements Maximum output levels Conducted emissions (9 khz 30 MHz) Radiated emissions (30 MHz 1 GHz) RF conducted signals immunity test (150 khz 80 MHz, 10 V rms) Narrow-band signals immunity test (95 khz - 150 khz; 150 khz - 30 MHz) Fast Transients Immunity test (2 kv, 5 khz) Surge Immunity test (4 kv, common mode and differential mode) RF radiated signals immunity test (150 khz - 80 MHz, 10 V rms) PASS - PASS - PASS - PASS - PASS PASS PASS PASS PASS In case of non-metering applications, communicating outside the CENELEC A band, please refer to the immunity requirements listed in the EN50065-2-1 document, which may set lower limits for some tests. In case of non-metering applications, communicating outside the CENELEC A band, please refer to the immunity requirements listed in the EN50065-2-1 document, which may set lower limits for some tests. RX impedance PASS - TX impedance PASS - 22/42 DocID029338 Rev 1

EN50065 compliance tests 8.1 EN50065-1: General requirements, frequency bands and electromagnetic disturbances 8.1.1 Test setup The tests in this section have been performed using the following setup: Figure 20: Bench setup for EN50065-1 tests Instruments references are described in Table 1. DocID029338 Rev 1 23/42

EN50065 compliance tests AN4875 The STCOMET development kit is configured for transmitting 192 ms packets with a 50% average duty cycle as shown in Figure 21. Figure 21: Transmitted signal for EN50065-1 tests The STCOMET development kit settings are the following: VCC = 15 V TX digital gain = maximum 24/42 DocID029338 Rev 1

EN50065 compliance tests 8.1.2 Determination of the bandwidth (EN50065-1 section 6.2.1) Table 9: Determination of the bandwidth Spectrum analyzer setup Measurement results RBW = 100 Hz Detector = PEAK MAX. Signal bandwidth = 58.6 khz (91.87 khz 33.33 khz) Trace display = MAX. HOLD Figure 22: Determination of the bandwidth (EN50065-1 section 6.2.1) 8.1.3 Determination of output level (EN50065-1 section 6.2.2) According to the tests results in section 8.1.2, the signal bandwidth of the STCOMET development kit is equal to 58.6 khz with a center frequency of 62.6 khz. Therefore, the following conclusions are valid for the execution of the tests 6.3 Maximum Outputs Levels in EN50065-1: The kit operating band is 9 khz 95 khz The kit signal is considered as a wide band signal The spectrum analyzer RBW must be set to 100 khz (unless otherwise specified). DocID029338 Rev 1 25/42

EN50065 compliance tests 8.1.4 Maximum output levels - sub-band above 9 khz up to 95 khz (EN50065-1 section 6.3.1.2) AN4875 8.1.4.1 Basic test: RBW = 100 khz (EN50065-1 section 6.3.1.2-b1) As the transmitted signal is wide-band, the basic test shall have the following settings: Table 10: Basic test: RBW = 100 khz Spectrum analyzer setup Measurement results Limit Verdict RBW = 100 khz Detector = PEAK MAX. Trace display = MAX. HOLD Max. level = 132.4 dbµv 134 dbµv max. PASS Figure 23: Max. output level RBW = 100 khz - 9 khz to 95 khz (EN50065-1 section 6.3.1.2) As we can notice, the test result above is quite tight to the standard limit. This is linked to the measurement method: due to the signal bandwidth measured at 52.6 khz, the spectrum analyzer bandwidth must be set to 100 khz (no possible step between 50 khz and 100 khz). On another hand, the measurement center frequency is sweeping from 9 khz to 95 khz, which is very low compared to the resolution bandwidth. Consequently, a portion of the signal negative spectrum is integrated in the power measurement itself. A second method has been used to measure the maximum output level, namely the Channel power measurement. This method is using narrow resolution bandwidth (2 khz), allowing rejecting sufficiently the negative spectrum power for measurements performed from 9 khz to 95 khz. 26/42 DocID029338 Rev 1

EN50065 compliance tests The Channel power function allows integrating the power across specified frequency bandwidth (58.6 khz) so that the real output level is measured. The result is illustrated in Figure 24 and the output level measured is equal to 124.14 dbµv. The margin in respect to the standard is quite comfortable. This measurement method has been compared to a further method, using an oscilloscope, and is giving similar results. Figure 24: Max. output level RBW = 2 khz - 9 khz to 95 khz (EN50065-1 section 6.3.1.2) DocID029338 Rev 1 27/42

EN50065 compliance tests 8.1.4.2 Additional test: RBW = 200 Hz (EN50065-1 section 6.3.1.2-b2) AN4875 As the transmitted signal is wide-band, the additional measurement (RBW = 200 Hz) must be executed. Table 11: Additional test: RBW = 200 Hz Spectrum analyzer setup Measurement results Limit Verdict RBW = 200 Hz Detector = PEAK MAX. Trace display = MAX. HOLD Max. level = 113.4 dbµv 120 dbµv max. PASS Figure 25: Max. output level RBW = 200 Hz from 9 khz to 95 khz (EN50065-1 section 6.3.1.2) 8.1.5 Disturbance limits - application outside sub-bands (EN50065-1 section 7.1) The STCOMET development kit operates with G3-PLC FW in the CENELEC A band (9 khz to 95 khz). Therefore, the disturbance tests are performed in the following bands: 3 khz to 9 khz 95 khz to 150 khz 150 khz to 30 MHz 28/42 DocID029338 Rev 1

EN50065 compliance tests 8.1.6 Conducted disturbance - frequency range from 3 khz to 9 khz (EN50065-1 section 7.2.1) Table 12: Conducted disturbance - frequency range from 3 khz to 9 khz Spectrum analyzer setup Measurement results Limit Verdict RBW = 100 Hz, Detector = PEAK MAX., Trace display = MAX. HOLD Max. level = 57.9 dbµv 89 dbµv max. PASS Figure 26: LINE conducted disturbance from 3 khz to 9 khz (EN50065-1 section 7.2.1) DocID029338 Rev 1 29/42

EN50065 compliance tests AN4875 Figure 27: NEUTRAL conducted disturbance - 3 khz to 9 khz (EN50065-1 section 7.2.1) 30/42 DocID029338 Rev 1

EN50065 compliance tests 8.1.7 Conducted disturbance - frequency range from 9 khz to 150 khz (EN50065-1 section7.2.2) The band from 9 khz to 95 khz (A band) is skipped in this test since this is the G3-PLC operating band. Table 13: Conducted disturbance - frequency range from 9 khz to 150 khz Spectrum analyzer setup Start = 95 khz Stop = 150 khz RBW = 200 Hz Detector = QUASI- PEAK Trace display = CLEAR WRITE Measurement results Max. level: 48 dbµv/line; 48 dbµv/neutral Limit Decreasing linearly with the logarithm of frequency from (9 khz 89 dbµv) to (150 khz - 66 dbµv), 95 khz =>69.734 dbµv Verdict PASS Figure 28: LINE conducted disturbance from 95 khz to 150 khz (EN50065-1 section 7.2.2) DocID029338 Rev 1 31/42

EN50065 compliance tests Figure 29: NEUTRAL conducted disturbance - from 95 khz to 150 khz (EN50065-1 section 7.2.2) AN4875 32/42 DocID029338 Rev 1

EN50065 compliance tests 8.1.8 Conducted disturbance - frequency range from 150 khz to 30 MHz (EN50065-1 section 7.2.3) Two measurements are performed, with quasi-peak detector and average detector, and compared with the associated limits. Spectrum analyzer setup RBW = 9 khz Detector = QUASI-PEAK + AVERAGE Trace display = CLEAR WRITE Table 14: Conducted disturbance - frequency range from 150 khz to 30 MHz LISN setup 150 khz high pass filter enabled Measurement results Max. level: 48 dbµv/line; 48 dbµv/neutral Limit Quasi-peak detector: Decreasing linearly with the logarithm of frequency from (150 khz - 66 dbµv) to (500 khz 56 dbµv) 56 dbµv from 500 khz to 5 MHz 60 dbµv from 5 MHz to 30 MHz Average detector: = Quasi-peak limits minus 10 db Verdict PASS Figure 30: LINE conducted disturbance from 150 khz to 30 MHz (EN50065-1 section 7.2.3) DocID029338 Rev 1 33/42

EN50065 compliance tests Figure 31: NEUTRAL conducted disturbance from 150 khz to 30 MHz (EN50065-1 section 7.2.3) AN4875 34/42 DocID029338 Rev 1

EN50065 compliance tests 8.1.9 Radiated disturbance field strength (EN50065-1 section 7.3) Figure 32 illustrates the radiated disturbances generated by the STCOMET development kit. The tests have been performed by an external laboratory. Analyzer setup Detector = QUASI-PEAK Table 15: Radiated disturbance field strength Measurement Limit results Max. level: 38 dbμv/line; 38 dbμv/neutral 30 to 230 MHz: 40 dbμv/m 230 MHz to 1 GHz: 47 dbμv/m Since the measurement distance is reduced at 3 meters, the limits are increased by a factor of 10 db compared to EN50065-1limits. Verdict PASS Figure 32: Radiated disturbance (EN50065-1 section 7.3) DocID029338 Rev 1 35/42

EN50065 compliance tests 8.2 EN50065-2-3: immunity requirements AN4875 8.2.1 Electrical Fast Transients (EFT) and Surge Immunity Figure 33: EFT and Surge Immunity test setup During the EFT and Surge Immunity tests, a communication is established between the E.U.T (STCOMET development kit) and the stimulus generator (STCOMET kit main board supplied by an external 15 V DC source on J7). The stimulus acts as a PAN coordinator, and the E.U.T. acts as a PAN device. The coordinator is sending frames to the E.U.T. and expects to receive a frame answer in the reverse direction ( ping ). The coordinator is displaying on the LCD the total number of transmitted frames and the number of error frames. 36/42 DocID029338 Rev 1

8.3 EN50065-7: equipment impedance EN50065 compliance tests For a PLC node, particular attention must be paid to the impedance of the line coupling circuit. Specifically: In the receiving (idle) mode, the coupling impedance must be high enough to make the power line source impedance negligible and to minimize the mutual interference between different PLC nodes connected to the same network In the transmitting mode, the coupling impedance must be very low inside the signal bandwidth but high enough for out-of-band frequencies. According to such requirements, the EN50065-7 standard document fixes the following constraints for the PLC node operating in the A band: Tx mode: Free in the range from 3 to 95 khz 3 Ω from 95 to 148.5 khz Rx mode: 10 Ω from 3 to 9 khz 50 Ω between 9 and 95 khz only inside the signal bandwidth (free for frequencies outside the signal bandwidth) 5 Ω from 95 to 148.5 khz. Figure 34 and Figure 35 show the input impedance magnitude vs. frequency measured in the reception and transmission mode. The impedance magnitude values prove that the STCOMET reference design is compliant with the EN50065-7 requirements. At the same time, the line interface gives an efficient signal coupling both in the transmission and reception. Figure 34: Input impedance reception mode DocID029338 Rev 1 37/42

EN50065 compliance tests Figure 35: Input impedance - transmission mode AN4875 38/42 DocID029338 Rev 1

References 9 References 1. STCOMET datasheet 2. Getting started with the STCOMET platform development environment (UM1833) 3. STCOMET smart meter and power line communication system-on-chip development kit application note (AN4732) 4. STCOMET development kit schematics and PCB layout. DocID029338 Rev 1 39/42

Normative references AN4875 10 Normative references EN50065: Signaling on low voltage electrical installations in the frequency range 3 khz to 148.5 khz. Part 1: General requirements, frequency bands and electromagnetic disturbances Part 2-3: Immunity requirements Part 4-2: Low voltage decoupling filters - Safety requirements Part 7: Equipment impedance. 40/42 DocID029338 Rev 1

Revision history 11 Revision history Table 16: Document revision history Date Version Changes 09-Jun-2016 1 Initial release. DocID029338 Rev 1 41/42

IMPORTANT NOTICE PLEASE READ CAREFULLY STMicroelectronics NV and its subsidiaries ( ST ) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold pursuant to ST s terms and conditions of sale in place at the time of order acknowledgement. Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of Purchasers products. No license, express or implied, to any intellectual property right is granted by ST herein. Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product. ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners. Information in this document supersedes and replaces information previously supplied in any prior versions of this document. 2016 STMicroelectronics All rights reserved 42/42 DocID029338 Rev 1