Optical Fiber Technology. Using 10 Gb/s remodulation DPSK signal in self-restored colorless WDM-PON system

Similar documents
Optical Fiber Technology

A WDM passive optical network enabling multicasting with color-free ONUs

A HIGH SPEED WDM PON FOR DOWNSTREAM DPSK ASK SIGNALS AND UPSTREAM OOK SIGNAL WITH BROADCAST CAPABILTY

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

Colorless Amplified WDM-PON Employing Broadband Light Source Seeded Optical Sources and Channel-by-Channel Dispersion Compensators for >100 km Reach

Utilizing Self-Seeding RSOA with Faraday Rotator Mirror for Colorless Access Network

PERFORMANCE ANALYSIS OF WDM PONS BASED ON FP-LD USING RZ-OOK AND NRZ-OOK

S-band gain-clamped grating-based erbiumdoped fiber amplifier by forward optical feedback technique

Wavelength Division Multiplexing Passive Optical Network (WDM-PON) technologies for future access networks

Optical fiber-fault surveillance for passive optical networks in S-band operation window

80 GBPS DOWNSTREAM TRANSMISSION USING DQPSK AND 40 GBPS UPSTREAM TRANSMISSION USING IRZ/OOK MODULATION IN BIDIRECTIONAL WDM-PON

Cost-effective wavelength-tunable fiber laser using self-seeding Fabry-Perot laser diode

Downstream Transmission in a WDM-PON System Using a Multiwavelength SOA-Based Fiber Ring Laser Source

Performance Analysis of Chromatic Dispersion Compensation of a Chirped Fiber Grating on a Differential Phase-shift-keyed Transmission

Mahendra Kumar1 Navneet Agrawal2

WDM-PON Delivering 5-Gbps Downstream/2.5-Gbps Upstream Data

Novel Design of Long Reach WDM-PON by using Directly Modulated RSOA

RADIO-OVER-FIBER TRANSPORT SYSTEMS BASED ON DFB LD WITH MAIN AND 1 SIDE MODES INJECTION-LOCKED TECHNIQUE

A bidirectional radio over fiber system with multiband-signal generation using one singledrive

DESIGN OF BIDIRECTIONAL PASSIVE OPTICAL NETWORK USING DIFFERENT MODULATIONS

PERFORMANCE EVALUATION OF GB/S BIDIRECTIONAL DWDM PASSIVE OPTICAL NETWORK BASED ON CYCLIC AWG

Spectrally Compact Optical Subcarrier Multiplexing with 42.6 Gbit/s AM-PSK Payload and 2.5Gbit/s NRZ Labels

Enhanced 10 Gb/s operations of directly modulated reflective semiconductor optical amplifiers without electronic equalization

20-Gb/s Transmission Over 25-km in Wavelength Division Multiplexing Passive Optical Network with Centralized Light Source

ANALYSIS OF BIDIRECTIONAL LONG REACH WDM PON

A broadband fiber ring laser technique with stable and tunable signal-frequency operation

1.25-Gb/s Millimeter-Wave Band Wired/Wireless Radio-over-Fiber System based on RSOA using an Injection-Locked FP-Laser

Design of Multiband RoF-PoN for Down Stream and Wavelength Reuse to Upstream

All-optical NRZ to RZ format and wavelength converter by dual-wavelength injection locking

Evolution from TDM-PONs to Next-Generation PONs

Design and Performance Evaluation of 20 GB/s Bidirectional DWDM Passive Optical Network Based on Array Waveguide Gratings

Temporal phase mask encrypted optical steganography carried by amplified spontaneous emission noise

SIMULATIVE INVESTIGATION OF SINGLE-TONE ROF SYSTEM USING VARIOUS DUOBINARY MODULATION FORMATS

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING. FINAL EXAMINATION, April 2017 DURATION: 2.5 hours

Power margin improvement for OFDMA-PON using hierarchical modulation

40Gb/s Optical Transmission System Testbed

22-Channel Capacity of 2.5Gbit/s DWDM-PON ONU Transmitter by Direct-Modularly Side-Mode Injection Locked FPLD

Dynamic gain-tilt compensation using electronic variable optical attenuators and a thin film filter spectral tilt monitor

THE WAVELENGTH-division multiplexed passive optical

Multi-format receiver for non-return-to-zero binary-phase-shift-keyed and non-return-to-zero amplitude-shit-keyed signals

Demonstration of bi-directional LED visible light communication using TDD traffic with mitigation of reflection interference

A continuously tunable and filterless optical millimeter-wave generation via frequency octupling

Microwave and Optical Technology Letters. Minhui Yan, Qing-Yang Xu 1, Chih-Hung Chen, Wei-Ping Huang, and Xiaobin Hong

A Long Haul Carrier Generated Ultra Dense Passive Optical Network Incorporating Low Cost VCSEL

Visible to infrared high-speed WDM transmission over PCF

Gigabit Transmission in 60-GHz-Band Using Optical Frequency Up-Conversion by Semiconductor Optical Amplifier and Photodiode Configuration

Full duplex 60-GHz RoF link employing tandem single sideband modulation scheme and high spectral efficiency modulation format

SCIENCE CHINA Technological Sciences. A flexible multi-16qam transmitter based on cascaded dual-parallel Mach-Zehnder modulator and phase modulator

Sensitivity evaluation of fiber optic OC-48 p-i-n transimpedance amplifier receivers using sweep-frequency modulation and intermixing diagnostics

π code 0 Changchun,130000,China Key Laboratory of National Defense.Changchun,130000,China Keywords:DPSK; CSRZ; atmospheric channel

A Full-duplex OSSB Modulated ROF System with Centralized Light Source by Optical Sideband Reuse

Optical monitoring technique based on scanning the gain profiles of erbium-doped fiber amplifiers for WDM networks

Vol. 6, No. 9 / September 2007 / JOURNAL OF OPTICAL NETWORKING 1105

Provision of IR-UWB wireless and baseband wired services over a WDM-PON

1.25 Gb/s Broadcast Signal Transmission in WDM-PON Based on Mutually Injected Fabry-Perot Laser Diodes

JOURNAL OF LIGHTWAVE TECHNOLOGY, VOL. 28, NO. 16, AUGUST 15, /$ IEEE

All-VCSEL based digital coherent detection link for multi Gbit/s WDM passive optical networks

Performance Comparison of Pre-, Post-, and Symmetrical Dispersion Compensation for 96 x 40 Gb/s DWDM System using DCF

Long-distance fiber grating sensor system using a fiber ring laser with EDWA and SOA

Radio over Fiber Technology for Investigation of Hybrid Passive Optical Networks

Enhanced Reflection Tolerance of Upstream Signal in a RSOA-based WDM PON by using Manchester Coding

SHF Communication Technologies AG

Recon gurable WDM add/drop multiplexer based on optical switches and bre Bragg gratings

MULTICHANNEL COST EFFECTIVE FULL DUPLEX RADIO OVER FIBER COMMUNICATION SYSTEM USING FIBER BRAGG GRATING FILTER

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

Comparative Analysis Of Different Dispersion Compensation Techniques On 40 Gbps Dwdm System

Mitigation of Mode Partition Noise in Quantum-dash Fabry-Perot Mode-locked Lasers using Manchester Encoding

Study of Orthogonal Modulation Schemes for Passive. Optical Access Networks.

International Journal of Emerging Technology and Advanced Engineering Website: (ISSN , Volume 2, Issue 6, June 2012)

ECEN689: Special Topics in Optical Interconnects Circuits and Systems Spring 2016

Simulative Analysis of 40 Gbps DWDM System Using Combination of Hybrid Modulators and Optical Filters for Suppression of Four-Wave Mixing

Wavelength Interleaving Based Dispersion Tolerant RoF System with Double Sideband Carrier Suppression

Performance Analysis of Dwdm System With Different Modulation Techique And Photodiode

All-Optical Signal Processing. Technologies for Network. Applications. Prof. Paul Prucnal. Department of Electrical Engineering PRINCETON UNIVERSITY

FWM Suppression in WDM Systems Using Advanced Modulation Formats

Novel OBI noise reduction technique by using similar-obi estimation in optical multiple access uplink

OFC SYSTEMS Performance & Simulations. BC Choudhary NITTTR, Sector 26, Chandigarh

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG

WAVELENGTH REUSE IN UWB-OVER-FIBER NETWORKS

Wavelength-Enhanced Passive Optical Networks with Extended Reach

Part III Optical Communications

A SURVEY ON CHALLENGES IN WDM-PON SYSTEMS

A DWDM/SCM Self-Healing Architecture for Broad-Band Subscriber Networks

SEMICONDUCTOR lasers and amplifiers are important

REDUCTION OF CROSSTALK IN WAVELENGTH DIVISION MULTIPLEXED FIBER OPTIC COMMUNICATION SYSTEMS

Risk Reduction in Operations, Maintenance and Application for Customer Access Network

Investigation of Performance Analysis of EDFA Amplifier. Using Different Pump Wavelengths and Powers

DIRECT MODULATION WITH SIDE-MODE INJECTION IN OPTICAL CATV TRANSPORT SYSTEMS

To generate a broadband light source by using mutually injection-locked Fabry-Perot laser diodes

Progress In Electromagnetics Research Letters, Vol. 8, , 2009

High bit-rate combined FSK/IM modulated optical signal generation by using GCSR tunable laser sources

Eye-Diagram-Based Evaluation of RZ and NRZ Modulation Methods in a 10-Gb/s Single-Channel and a 160-Gb/s WDM Optical Networks

Implementation and analysis of 2 Tbps MDRZ DWDM system at ultra narrow channel spacing

FULL COLORLESS GIGABIT WAVELENGTH-DIVISION MULTIPLEXED- PASSIVE OPTICAL NETWORK SUPPORTING SIMULTANEOUS TWO DIFFERENT DATA TRANSMISSION

Implementation of Dense Wavelength Division Multiplexing FBG

Design of Ultra High Capacity DWDM System with Different Modulation Formats

Research on Optical Access Network. Assoc. Prof. Dr. Duang-rudee Worasucheep Electrical Engineering Department Chulalongkorn University

Proposal of A Star-16QAM System Based on Intersymbol Interference (ISI) Suppression and Coherent Detection

SOA-BASED NOISE SUPPRESSION IN SPECTRUM-SLICED PONs: IMPACT OF BIT-RATE AND SOA GAIN RECOVERY TIME

Comparison of Polarization Shift Keying and Amplitude Shift Keying Modulation Techniques in FSO

Transcription:

Optical Fiber Technology 15 (2009) 274 278 Contents lists available at ScienceDirect Optical Fiber Technology www.elsevier.com/locate/yofte Using 10 Gb/s remodulation DPSK signal in self-restored colorless WDM-PON system Chien Hung Yeh a,, Chi Wai Chow b,sienchi c a Information and Communications Research Laboratories, Industrial Technology Research Institute, Rm. 300, Bldg. 14, 195, Sed. 4, Chung Hsing Rd., Chutung, Hsinchu 31040, Taiwan b Department of Photonics and Institute of Electro-Optical Engineering, National Chiao Tung University, Hsinchu 30010, Taiwan c Department of Electrical Engineering, Yuan Ze University, Chung-Li 32003, Taiwan article info abstract Article history: Received 25 June 2008 Revised 5 December 2008 Availableonline26January2009 Keywords: DPSK Colorless WDM-PON Self-protection In this investigation, we propose and experimentally demonstrate the remodulation technique using DPSK format in both downlink and uplink traffics with high extinction ratio (ER) in colorless WDM- PON; together with a simple self-restored architecture against fiber fault. Error free operation was achieved in a 20-km-reach 10-Gb/s WDM-PON without dispersion compensation. Comparison with other wavelength remodulation schemes for WDM-PONs is also performed, showing the proposed scheme can be a potential candidate for next generation wavelength reuse WDM-PONs. In addition, the performance of self-protection has also been discussed and analyzed. Crown Copyright 2008 Published by Elsevier Inc. All rights reserved. 1. Introduction Wavelength-division-multiplexed passive optical network (WDM-PON) is a potentially cost-effective technology to increase individual bandwidth capacity through the use of wavelength domain [1,2]. One of the great challenges in the WDM-PON is that the wavelength of the optical uplink signal generated from the optical networking unit (ONU) must be precisely aligned to the WDM grid wavelength of the wavelength multiplexers and demultiplexers. A cost-effective solution would use the same and colorless ONU for the PON. Furthermore, remodulation of downlink wavelength to generate uplink wavelength can further reduce the cost. Several remodulation schemes have been proposed for the WDM-PONs, such as using on off keying (OOK), differential phase shift keying (DPSK), and inverse return-to-zero (IRZ) [3 7]. However, they are limited by various combinations of high chirp, limited speed, and reduced extinction ratio (ER). Using DPSK downlink and OOK uplink generated by a reflective semiconductor optical amplifier (RSOA) [8]; and using asymmetric OOK downlink and uplink have been proposed [9], but the data rate of uplinks are limited by the RSOA. Besides, a bi-directional WDM- PON has been demonstrated using RSOA-biased ONU working as a modulator and a photodetector time-divisionally [10], however the scheme reduces the bandwidth in both downlink and uplink signals. In addition, a reliable and survivable PON architecture with self-protection and self-restoration functions is highly desirable and necessary. Several reports have been presented to offer the * Corresponding author. E-mail address: depew@itri.org.tw (C.H. Yeh). protection capability in the PON access networks [11 13]. As the per channel data rate in WDM-PONs are envisioned to 10 Gb/s or more in the future, the network reliability and survivability of such high-speed networks need to be addressed. In this paper, we propose and demonstrate a simple selfrestoration scheme for a 10 Gb/s bi-directional WDM-PON. The self-protection scheme using dual distribution fibers has been suggested in ITU-T G.983.1 for conventional time division multiplexed (TDM)-biased G-PON, however this scheme requires a backup optical line terminal (OLT) and a backup ONU for each ONU. Here, we extends the studies to the 10 Gb/s bi-directional WDM-PON, enabling wavelength reuse and supporting DPSK format [14] [one of the promising advanced modulation formats for future network to mitigate fiber nonlinearities and to improve receiver (Rx) sensitivity] in both downlink and uplink. Detail self-restored mechanism using an optical switch (OS) instead of using a backup ONU and OLT is presented. Fast switching time of 10 ms is achieved in the self-restored WDM-PON. Comparison of Rx sensitivities and power budgets of the proposed scheme with other wavelength remodulation schemes is also performed by means of numerical simulations. 2. Experiments and results Fig. 1 shows the proposed architecture of the self-restored bidirectional WDM-PON using centralized light sources for N ONUs. At the OLT, the continuous wave (CW) optical signal at 1550 nm wavelength produced by a distributed feedback laser diode (DFB- LD) was encoded to form the 10 Gb/s DPSK downlink signal via a LiNbO 3 phase modulation (PM). The PM was electrically driven by a differentially precoded 10 Gb/s, pseudorandom binary sequence 1068-5200/$ see front matter Crown Copyright 2008 Published by Elsevier Inc. All rights reserved. doi:10.1016/j.yofte.2008.12.002

C.H. Yeh et al. / Optical Fiber Technology 15 (2009) 274 278 275 Fig. 1. The proposed self-protected WDM-PON architecture without any fiber fault using remodulation DPSK both in downlink and uplink signals. Fig. 2. Proposed self-protected WDM-PON architecture when a fault occurs on the distribution fiber (working fiber) between RN and ONU 1. (PRBS) 2 15 1 nonreturn-to-zero (NRZ) data (D, where prime down represents differentially precoded). The downlink signal was then transmitted through a 10-km feeder single-mode fiber (SMF) and 10-km distribution fiber. The optical fiber cannot be fully dispersion compensated in practice hence no dispersion compensation was used in the setup. Inside the OLT, the optical circulator (OC) connected to a 1 2 optical coupler (CP), and the two output ports of CP were used to connect the working and protection fiber paths in the remote node (RN), as shown in Fig. 1. The RN consisted of two arrayed waveguide grating (AWG) to serve as the working and protection paths. 10% of optical power from the downlink DPSK signal was received by an optically pre-amplified Rx with 10-Gb/s PIN at the ONU. The residual power was launched into a PM to produce the uplink signal. In order to recode the phase information onto the downlink signal, D down D up is applied to the PM, where is the exclusive-or (XOR) logic operation. Since D down D down = 0, and 0 D up = D up, the phase information was successfully recode and only D up remained in the phase, creating the uplink signal. The timing alignment between the downlink and the applied electrical signals to the PM is crucial, and this can be controlled by using electrical buffers. We measured the timing misalignment tolerance, and the 1-dB power penalty window at bit-error rate (BER) of 10 9 was about 20 ps. Here, we would like to present the self-restored mechanism of the scheme. Inside each ONU, there was a 1 2 OS to select the working or protection mode. When there is no fiber fault in the PON, the OS inside each ONU was located to the working path, as illustrated in Fig. 1. It is worth to note that there are two places where fiber fault may occur: on the feeder fiber or the distribution fiber, as shown in Figs. 2 and 3 respectively. When a fault occurs on the distribution fiber as shown in Fig. 2, the ONU 1 cannot receive data from the OLT. Thus, the OS (consisted of an optical power monitor which keeps monitoring the downlink signal in the ONU) in the ONU 1 will immediately switch to protection mode connecting the protection fiber. Based on the same mechanism, when a fault occurs on working feeder fiber, as shown in Fig. 3, all the ONUs in the PON cannot communicate with the OLT. Then, the entire OSs in the ONUs will switch to link the protection fiber. In the experiment, the 1 2 OS was used as a protection switch, and the switching characteristic is shown in Fig. 4. The switch-

276 C.H. Yeh et al. / Optical Fiber Technology 15 (2009) 274 278 Fig. 3. Proposed self-protected WDM-PON architecture when a fault occurs on the feeder fiber (working fiber) between OLT and RN. Fig. 4. Protection switching time measurement for the self-protected system. Fig. 5. BER measurements of the 10 Gb/s DPSK-based downlink and remodulation uplink signals without and with protection through 20-km SMF in the proposed protection PON network. ing and restoration time is measured within 10 ms, showing that the proposed self-protection architecture can protect and restore the WDM-PON effectively when the fiber fault occurs. Fig. 5 shows the 10 Gb/s BER measurements of the proposed scheme with and without protection. Power penalty was measured of about 1.3 db at BER of 10 9 for the demodulated DPSK downlink signal at the ONU after the 20 km SMF in the working and protection paths. Power penalty of 4.5 db was measured for the remodulated uplink DPSK signal at the OLT. The power penalty was due to the accumulated dispersion of the 40-km SMF and the remodulation process. The results show that low ER downlink signal is not required for the uplink remodulation, when compared with other remodulation scheme [6]. Comparison with previously proposed remodulation schemes was made to show the advantages of the proposed remodulation scheme. Numerical analysis using VPI Transmission Maker V7.5 was performed to evaluate the back-to-back Rx sensitivity penalty of different remodulation schemes when compared with the NRZ modulation (Table 1). 10 Gb/s PRBS 2 7 1 was used for all the schemes in both uplink and downlink signals. The signal power in each case was 0 dbm. The NRZ signal was generated by using a Mach Zehnder modulator (MZM) with electrical bandwidth = 10 GHz. The NRZ signal was detected by an optical pre-amplified Rx (noise figure = 5 db) with optical filter bandwidth = 50 GHz and photodiode electrical bandwidth = 7.5 GHz. We compared the DPSK [with and without balance detection (BD)] with the previously proposed remodulation schemes, including downlink IRZ and uplink OOK [5]; downlink low ER-OOK and uplink DPSK [6]. First, we studied the remodulation of the DPSK scheme. The DPSK was generated by a PM with electrical bandwidth of 10 GHz. It was detected by using the same Rx as in the case of NRZ signal. No power penalty was observed, and in principle, Rx sensitivity improvement of 3 db can be observed when BD was used. For the IRZ downlink and OOK uplink remodulation scheme, an electrical IRZ data was applied to the intensity modulator to produce the optical IRZ signal. The duty cycle of the IRZ used was 50%, as in Ref. [5]. Power penalty of 6.8 db was observed in the IRZ signal at BER of 10 9. The power penalty was due to the relative high residual CW background between adjusted IRZ pulses. It was worth to mention that there is a tradeoff between the duty cycle of the IRZ and the remodulated uplink OOK data [15]; and the duty cycle of the IRZ can affect the Rx sensitivity. The simulation results of the normalized Rx sensitivities of the IRZ against the IRZ duty cycle are shown in Fig. 6. We observed a negative power penalty of 0.5 db in the uplink OOK because it was return-to-zero (RZ)-liked. For the low-er OOK downlink and DPSK uplink scheme, a low-er OOK downlink signal was required to provide enough residual optical power for the uplink remodulation. The reduced ER = 4.9 db was generated by adjusting the dc-bias of the MZM. Hence, a high power

C.H. Yeh et al. / Optical Fiber Technology 15 (2009) 274 278 277 Table 1 Comparison of different remodulation schemes at back-to-back Rx penalty with NRZ signal. DPSK (down)/ DPSK (down)/ IRZ (down)/ Low ER-OOK (down)/ Low ER-OOK (down)/ DPSK (up) DPSK (up) BD OOK (up) DPSK (up) DPSK (up) BD Power penalty (down) 0 db 3 db +6.8 db +7.2 db +7.2 db Power penalty (up) 0 db 3 db 0.5 db Error floor at BER 10 8 +10 db Acknowledgments This work was supported in part by the National Science Council of ROC (Taiwan) under Contracts NSC-96-2221-E-155-038- MY2-1, NSC-96-2221-E-155-039-MY3-1, NSC 96-2218-E-009-025- MY2, NSC 97-2221-E-009-038-MY3. References Fig. 6. Simulation of the normalized Rx sensitivities of the IRZ against the IRZ duty cycle. penalty of 7.2 db was observed. BER < 10 9 DPSK uplink detection was not possible unless BD (power penalty of 10 db) was used. The power penalty was due to the conversion of the low-er OOK downlink signal to amplitude fluctuation in the uplink DPSK signal. By considering the insertion losses of the AWG, OC, OS, PM and the intensity modulator (IM) (used in IRZ/DPSK scheme) are 4 db, 1 db, 1 db, 4 db and 4 db respectively, fiber loss is 0.2 db/km, and the Rx sensitivities of the DPSK, IRZ, remodulated OOK from the IRZ, low-er OOK, and amplitude-fluctuated DPSK from the low-er OOK are 37 dbm (BD is used), 27.2 dbm, 34.5 dbm, 26.8 dbm and 24 dbm (BD is used) [14] respectively, we can calculate the power budgets of the network using different remodulation schemes. We also assume BD was used for the DPSK detection. In order to avoid fiber nonlinear effects, launch power of 8 dbm was used in each case. For the proposed DPSK/DPSK scheme, error free BER can be detected both in downlink and uplink, and 4 db power margin can be observed at the remodulated uplink DPSK signal at the head-end Rx. Optical amplifier can be included in the transmission fiber to improve the power margin. For the IRZ/OOK scheme, error free BER can also be achieved in both downlink and uplink, and 1.5 db power margin was observed. For the low-er OOK/DPSK scheme, error free BER can be observed in the downlink detected at the ONU, however, there is not enough power budget (lacking of 9 db) for the uplink DPSK signal. [1]G.Talli,C.W.Chow,E.K.MacHale,P.D.Townsend,LongreachhybridDWDM- TDM PON with high split ratio employing centralized light source, J. Opt. Network. 6 (2007) 765 776. [2] H.D. Kim, S.G. Kang, C.H. Lee, A low-cost WDM source with an ASE injected Fabry Perot semiconductor laser, IEEE Photon. Technol. Lett. 12 (2000) 1067 1069. [3] L.Y. Chan, C.K. Chan, D.T.K. Tong, F. Tong, L.K. Chen, Upstream traffic transmitter using injection-locked Fabry Perot laser diode as modulator for WDM access networks, Electron. Lett. 38 (2002) 43 45. [4] W. Hung, C.K. Chan, L.K. Chen, F. Tong, An optical network unit for WDM access networks with downstream DPSK and upstream remodulated OOK data using injection-locked FP laser, IEEE Photon. Technol. Lett. 15 (2003) 1476 1478. [5] G.W. Lu, N. Deng, C.K. Chan, L.K. Chen, Use of downstream IRZ signal for upstream data re-modulation in a WDM passive network, in: Proc. OFC, 2005, Paper OFI8. [6] J. Zhao, L.K. Chen, C.K. Chan, A novel re-modulation scheme to achieve colorless high-speed WDM-PON with enhanced tolerance to chromatic dispersion and re-modulation misalignment, in: Proc. OFC, 2007, Paper OWD2. [7] Y. Tian, Y. Su, L. Yi, L. Leng, X. Tian, H. He, X. Xu, Optical VPN in PON based on DPSK erasing/rewriting and DPSK/IM formatting using a single Mach Zehnder modulator, in: Proc. ECOC, 2006, Paper Tu4.5.6. [8] N. Calabretta, M. Presi, R. Proietti, G. Contestabile, E. Ciaramella, A bidirectional WDM/TDM-PON using DPSK downstream signals and a narrowband AWG, IEEE Photon. Technol. Lett. 19 (2007) 1227 1229. [9] A.T.C. Luk, O. Boyraz, Performance analysis of a FTTH link utilizing asymmetric data transmission, Opt. Commun. 280 (2007) 431 434. [10] J. Prat, C. Arellano, V. Polo, C. Bock, Optical network unit based on a bidirectional reflective semiconductor optical amplifier for fiber-to-the-home networks, IEEE Photon. Technol. Lett. 17 (2005) 250 252. [11] T.J. Chan, C.K. Chan, L.K. Chen, F. Tong, A self-protected architecture for wavelength division multiplexed passive optical networks, IEEE Photon. Technol. Lett. 15 (2003) 1660 1662. [12] Z. Wang, B. Zhang, C. Lin, C.K. Chan, A broadcast and select WDM-PON and its protection,in:ecoc,2005,paperwe4.p.024. [13] X. Sun, C.K. Chan, L.K. Chen, A survivable WDM-PON architecture with centralized alternate-path protection switching for traffic restoration, IEEE Photon. Technol. Lett. 18 (2006) 631 633. [14] C.W. Chow, Wavelength remodulation using DPSK down-and-upstream with high extinction ratio for 10-Gb/s DWDM-passive optical networks, IEEE Photon. Technol. Lett. 20 (2008) 12 14. [15] N. Deng, C.K. Chan, L.K. Chen, A centralized-light-source WDM access network utilizing inverse-rz downstream signal with upstream data remodulation, Opt. Fiber Technol. 13 (2007) 18 21. 3. Conclusion We proposed and investigated a new self-restored WDM-PON to avoid the fiber fault in both feeder and distribution fibers. Besides, in this experiment, we also used the remodulation method in both uplink and downlink at 10 Gb/s, with high ER signals in both directions. A 20 km-reach PON without dispersion compensation was demonstrated and error free transmission was achieved during the remodulation process and in working and protection paths. As a result, the proposed scheme can be a potential candidate for next generation wavelength reuse WDM-PON. Chien Hung Yeh received the B.S. and M.S. degrees from the Physics Department, Fu Jen Catholic University, Taiwan, in 1998 and 2000, respectively. He received his Ph.D. degree from the Institute of Electro- Optical Engineering, National Chiao Tung University, Taiwan, in 2004. He is working in the Information and Communications Laboratories, Industrial Technology Research Institute, Taiwan. His research interests are optical fiber communications, fiber lasers, fiber amplifiers, WDM transmissions, and fiber access network technologies.

278 C.H. Yeh et al. / Optical Fiber Technology 15 (2009) 274 278 Chi Wai Chow received the B.Eng. (First-Class Hons) and Ph.D. degrees both from the Department of Electronic Engineering, the Chinese University of Hong Kong, in 2001 and 2004, respectively. After graduation, he was appointed as a Postdoctoral Fellow at the CUHK, working on hybrid integration of photonic components and silicon waveguides. Between 2005 and 2007, he was a Postdoctoral Research Scientist, working mainly on two European Union Projects: PIEMAN (Photonic Integrated Extended Metro and Access Network) and TRIUMPH (Transparent Ring Interconnection Using Multi-wavelength Photonic switches) in the Tyndall National Institute and Department of Physics, University College Cork in Ireland. In 2007, he joined the Department of Photonics, National Chiao Tung University in Taiwan, as an Assistant Professor. Sien Chi received his Ph.D. in electrophysics from the Polytechnic Institute of Brooklyn, New York, in 1971, and joined the faculty of National Chiao Tung University, where he is currently a professor of electro-optical engineering. From 1993 to 1996 he received the Distinguished Research Award sponsored by the National Science Council, Taiwan. Since 1996 he has been the chair professor of the Foundation for Advancement of Outstanding Scholarship. His research interests are optical fiber communications, optical solitons, and optical fiber amplifiers. He is a fellow of the Optical Society of America and the Photonics Society of Chinese-Americans.