HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

Similar documents
HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

HO4 Surface Mount Installation Instructions Overview

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

HP-2 Recessed Wall Wash Flush Diffuser Tech Zone 4" Starter/Independent Installation Instructions

HP-4 Wall Wash Recessed Flush Diffuser Visible Flange Starter/Independent Installation Instructions

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

EOS LED Surface Mounted Luminaire

LINESSE LINEAR LUMINAIRE 3 CEILING MOUNT CM2420

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Studio Face Xtreme 6020 Installation Instructions (Nickel , Black )

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

Installation Instruction

VINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Assembly Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SAVE THESE INSTALLATION INSTRUCTIONS

Mount to the Wall INSTALLATION MANUAL

Lightplane 3.5 Recessed

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

JK JEEP MIDWIDTH FRONT BUMPER

Parts list continues on Page 2 HOUSE PARTS PACKED IN HOUSE BOX PARTS IN SMALL PLASTIC BAG (HARDWARE) POST PARTS PACKED IN THIS BOX (LARGE PLASTIC BAG)

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART #

Adjustable Countertop Installation

BLUEMOTION UXP, CDP, SD

Installation Instructions

Yes 20 Charging Wall Cabinet for Tablets

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Oxford Stalls Installation Instructions

Installation Instructions

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

JK FRONT FENDER FLARE INSTALLATION INSTRUCTIONS

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

Baby Grande with Crank, Housing, and Side Rails Installation Instructions

Office Installation Guidelines

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

AXIOM Classic Trim Installation Instructions

General Installation Instructions

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

13MM FLAT WRENCH FOR LEVELING THE GLIDES OF STRUCTURE 6MM ALLEN KEY FOR ROOF CLIPS PHILLIPS HEAD BIT FOR SCREWS FOR DOOR FRAME

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY. 6 3/8" [161.9mm]

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

NX7 SERIES 5-1/2 HANDRAIL

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Hawko Zhaga Systems Installation Instructions

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Assembly Instructions for model: VMPR1

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Heavy Duty Ceiling Tilt Mount Installation Manual

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

INSTALLATION INSTRUCTIONS 3"/4 BENT END SIDEBARS FORD F-150 SUPERCREW PART # DZ /DZ

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

P a r k c o n s o l e s i n k a s s e m b l y i n s t r u c t i o n s

MESO X1 TBAR SEMI-RECESSED

Windload Post 9100/9600/9900 Installation Instructions

Gared Pro-S Portable Backstop

AXIOM Classic Trim. Assembly and Installation Instructions

Installation Instructions For TruLine 1.6A 24VDC

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

NOTE: Top section pole (Q) is packed INSIDE bottom section pole (S)

Dura-Lock Roof System

TITAN2-EDGE Public Access Computer Station Dual Track

Installation Manual Porter Road, Sarasota FL fax

EOS Direct/Indirect LED Pendant Luminaire

Dublin Stalls Installation Instructions

WG-4 Wall Guard Installation Instructions

COMPARE #01-12 OCTOBER 11, Original Vroom. Vroom Garage Ceiling Bracket #9547. Installation. (with L-Brackets) Ease of.

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

Laminate Cabinet Installation Instructions

HP-6. With Tailored Lighting. High Performance 6" Aperture LED COLLECTION. Direct Pendant Recessed Surface Mount Performance

Linear LED Recessed Luminaires

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

WINDLOAD POST WayneMark 8000, 8100 INSTALLATION INSTRUCTIONS

Sentinel Electronic Safe Installation Guide

Assembly Instructions

INSTALLATION INSTRUCTIONS

MPA-9000 Universal Ceiling Projector Mount Kit

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

MOTORIZED STANDARD SHADE WITH CABLES Installation Instructions

Transcription:

Overview Step 4 Mounting to Structure Page 6 Step 1 Mounting Locations & Rough-Ins Pages 2-3 Step 2 Identification & Preparation Page 4 Step 6 Securing Corner Joints Page 8 Step 3 Opening Luminaires Page 5 Helpful Video 0-10V Dimming NOTE Step 7 Mounting to Structure Pages 9-10 This installation requires proper support as each luminaire is being installed. DO NOT attempt to join luminaires together on the floor. Damage may result when lifted. Follow these instructions. Step 8 Securing Luminaire Joints Page 11 Step 5 Mounting to Structure Page 7 Step 9 Closing Luminaires Pages 12-13 Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 1 of 13

Step 1 - Mounting Locations & Rough-Ins Total Run Length Inside Corner Rough-In Lengths Y1 X1 X2 Z L1 Endcap Z ID: 1 Z ID: 2 L1 = Total Run Rough-In Length* X = Luminaire section length (Does not include endcaps) Y1 = Total run length of luminaire, depending on your build (Does not include endcaps) Y2 = Total run length of luminaire, depending on your build (Does not include endcaps) Z = Mounting hole location Refer to Record Drawings and building plans to determine exact mounting, suspension points, and power feed locations. ID: 3 X3 Y2 Spackle Flange Visible Flange HP-2 Y1-3-9/16" Y1-3-11/16" HP-4 Y1-3-7/16" Y1-3-9/16" HP-6 Y1-3-9/16" Y1-3-11/16" L2 = Total Run Rough-In Length* L2 Z = Mounting Hole Location (Does not include endcaps) HP-2 5" HP-4 6" Z Spackle Flange Visible Flange HP-2 Y2-3-9/16" Y2-3-11/16" HP-4 Y2-3-7/16" Y2-3-9/16" HP-6 Y2-3-9/16" Y2-3-11/16" W HP-6 6-1/2" * Tolerance +/- 1/16" Rough-In Widths Spackle Flange (SF) Use rough-in width dimension table below and Record Drawings to determine rough-in measurements. Build wall/ceiling with rough-in according to rough-in dimensions. CRITICAL: Drywall or weak paneling must be secured to blocking (studs) around rough-in opening in the wall/ceiling. Spackle Flange W = Rough-In Width* Visible Flange HP-2 3-1/8" 2-7/8" HP-4 4-7/8" 4-1/4" HP-6 6-1/8" 5-7/8" W Visible Flange (VF) W Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 2 of 13

Step 1 - Rough-Ins & Mounting Options Mounting Options Option 1 - Mount to Threaded Rod Option 2 - Mount to Structure 1/4" Threaded Rod Structure Support Support Blocking 3-1/2" min. Support Blocking 4-1/8" min. Drywall / Drywall / 1/4"-20 Washer & 1/4"-20 Nut 1/4" Lag Bolt Luminaire mounting holes sized for 1/4"-20 threaded rod. Refer to Record Drawings to determine mounting hole locations on luminaires and install threaded rods to structure. Distance from threaded rod to wall/ceiling surface must be a minimum of 3-1/2"¹. Mounting Option 1 Threaded Rod 1/4"-20 Washer 1/4"-20 Nut Mounting Option 2 1/4"-20 Lag Bolt ¹ /ceiling surface = drywall, wood, concrete or masonry, metal panels, tile, etc. ² Support blocking = Wooden beams/studs, sheet metal framing beams, steel beams, concrete beams, etc. Use hardware appropriate to the beam material. Refer to Record Drawings to determine mounting hole locations on luminaires and install support blocking² to structure. Distance from support block to wall/ceiling surface must be a minimum of 4-1/8"¹. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 3 of 13

A. Identify Luminaires B. Remove Diffuser Diffuser Protective Bag Job Name Factory Order Number Unique Luminaire ID Number ABC Corporation - A12345 HP-6 VF - X' STARTER HP-6 VF - 32' - H - 835 - F - 120V - SC - C1 ID: 1 Mud Guard (provided) Luminaire Type and/or Run Length Full Catalog Order ID Luminaire Section Type ID Labels Identify all luminaires by their ID label that can be found on the box, the diffuser and inside the luminaire. Remove all luminaires from their box. NOTE: Exact location of labels in these areas may vary. Arrange luminaires in order according to ID# at their install locations. Refer to Record Drawings that can be found in the hardware kit. Kitted Hardware Finelite has provided items listed here, with their Finelite part numbers. These items can be found in separate boxes shipped with the luminaire. Account for all parts and set aside until they are needed. All other hardware needed for this installation will be "by others". Yoke Bracket Part# 45042 #10-32 x 5/8" Screw Part# 94144 Securing Corner Joints p. 8, Step 6 Securing Luminaire Joints p. 11, Step 8 Carefully remove all diffusers, keeping them inside their protective bags. Set aside all diffusers to prevent from getting dirty or damaged. Ensure diffusers can be clearly identified back to its corresponding luminaire. CAUTION (Spackle Flange Only): Carefully remove "Mud Guards" and keep them as they will be reinstalled in Step 9, B. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 4 of 13

Step 3 - Opening Luminaire Release s Putty Knife Option Putty Knife Clip Flathead Screwdriver Option Clip Flathead Screwdriver Open all backplates for access to mounting points. Release the backplates from clips by sliding the blade of a putty knife behind backplate edges. To use a flathead screwdriver: From inside backplate, press end of screwdriver against the clip until the backplate is released. Clip Carefully rotate backplates out and let them hang from luminaire body. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 5 of 13

Step 4 - Mounting to Structure Mount to Structure Option 1 (Shown) - Mount to Threaded Rod 1/4"-20 Threaded Rod Support Blocking Support Blocking Drywall Drywall Option 2 - Mount to Structure Structure Support 1/4"-20 Lag Bolt Option 1 (Shown) - Mount to Threaded Rod Align threaded rods with mounting holes and slide luminaire into wall/ceiling. Install 1/4"-20 nut and 1/4"-20 washer onto 1/4"-20 threaded rod. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the nut loose, allowing the luminaire to angle out of ceiling at an angle. Mounting Option 1 Threaded Rod 1/4"-20 Washer 1/4"-20 Nut Mounting Option 2 1/4"-20 Lag Bolt Option 2 - Mount to Structure Slide luminaire into wall/ceiling and mount to structure support with hardware appropriate for the structure type. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the bolt/screw loose, allowing luminaire to hang out of ceiling at an angle. Support Blocking Drywall Support Blocking Drywall Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 6 of 13

Step 5 - Mounting to Structure Mount to Structure A A B Aligner Sleeves Option 1 (Shown) - Mount to Threaded Rod Align threaded rods with mounting holes and slide luminaire into wall/ceiling. Install 1/4"-20 nut and 1/4"-20 washer onto 1/4"-20 threaded rod. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the nut loose, allowing the luminaire to angle out of wall at an angle. B While properly supporting luminaire, maneuver luminaire near wall/ceiling opening. If necessary, loosen bolts on previous luminaire so that it can hang out of the opening at an angle. After installing a joiner, return to previous luminaire and tighten. Mounting Option 1 Threaded Rod 1/4"-20 Washer 1/4"-20 Nut Mounting Option 2 1/4"-20 Lag Bolt Align ender with aligner sleeves on joiner and slide together. Be careful not to damage any wiring. If necessary, lift both luminaires, then slide together. Option 2 - Mount to Structure Slide luminaire into wall/ceiling and mount to structure support with hardware appropriate for the structure type. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the bolt/screw loose, allowing luminaire to hang out of wall at an angle. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 7 of 13

Step 6 - Securing Corner Joints A. Secure Corner Joint with Yoke Brackets IN ALIGNMENT Mitered Corner Joint B. Make Electrical Connections Yoke Screws (provided) Yoke Brackets (provided) Aligner Sleeves CORRECTLY INSTALLED Mitered Corner Joint Plug-Together Wiring Before installing yoke brackets, ensure the joining corners of luminaires meet flush and square. CRITICAL: Ensure yoke brackets properly engage with aligner sleeves. Secure joint by threading (but not yet tightening) yoke screws through yoke brackets and into aligner sleeves. Yoke Bracket w/ Screw #10-32 x 5/8" (provided) Connect plug-together wiring. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 8 of 13

Step 7 - Mounting to Structure Make Electrical Connections Electrical Connection Options WIRING LEGEND Black Hot Line Voltage Wire-nut electrical connections. (Typical for all options.) White Neutral Line Voltage Green Ground Grey Dimming 0-10V DC Conduit Purple Dimming 0-10V DC Conduit Plate Jam Nut #8 Screws Jam Nut Conduit Plate Conduit Plate Jam Nut #8 Screw While properly supporting luminaire, maneuver luminaire near wall/ceiling opening. Make electrical connections at ENDCAP, at TOP or with a SPLICE BOX. Flex Conduit CONDUIT PLATE - ENDCAP Remove two screws holding conduit plate. Install conduit and jam nut onto conduit plate. Wire-nut electrical connections. See wiring legend above. Reinstall conduit plate and screws. Do not damage any wires. CONDUIT PLATE - TOP (HP-4 ONLY) Remove screw holding conduit plate. Install conduit and nut onto conduit plate. Wire-nut electrical connections. See wiring legend above. Reinstall conduit plate and screw. Do not damage any wires. SPLICE BOX (OPTIONAL) Lift tab to unsnap and remove splice box cover. Install conduit and nut onto splice box cover. Wire-nut electrical connections. See wiring legend above. Reinstall splice box cover. Do not damage any wires. CONTINUED Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 9 of 13

Step 7 - Mounting to Structure A. Mount to Structure B. Join Luminaires Aligner Sleeves Option 1 (Shown) - Mount to Threaded Rod Align threaded rods with mounting holes and slide luminaire into wall/ceiling. Install 1/4"-20 nut and 1/4"-20 washer onto 1/4"-20 threaded rod. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the nut loose, allowing the luminaire to angle out of ceiling at an angle. If there is no joiner/ender, then tighten nuts fully. Mounting Option 1 Threaded Rod 1/4"-20 Washer 1/4"-20 Nut Mounting Option 2 1/4"-20 Lag Bolt Option 2 - Mount to Structure Slide luminaire into wall/ceiling and mount to structure support with hardware appropriate for the structure type. CRITICAL: If installing a joiner/ender luminaire in the next step, leave the bolt/screw loose, allowing luminaire to hang out of ceiling at an angle. If there is no joiner/ender, then tighten nuts fully. Align starter aligner sleeves with joiner and slide together. Be careful not to damage any wiring. If necessary, lift both luminaires, then slide together. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 10 of 13

Step 8 - Securing Luminaire Joints A. Secure Joint with Yoke Brackets Cross Section IN ALIGNMENT CORRECTLY INSTALLED View Luminaire Joint Luminaire Joint B. Make Electrical Connections Aligner Sleeves Plug-Together Wiring Aligner Sleeves Yoke Brackets (provided) YOKE SCREW ALIGNMENT Bottom-Up View Luminaire Joint Aligner Sleeves 1 Screwdriver with 6" bit required. Yoke Screws (provided) Before installing yoke brackets, ensure the joining ends of luminaires meet flush and square. CRITICAL: Ensure yoke brackets properly engage with aligner sleeves. Secure all joints by using a screwdriver¹ to tighten yoke screws through yoke brackets and into the aligner sleeves until joint seam of luminaire is closed. Yoke Bracket w/ Screw #10-32 x 5/8" (provided) NO NOTE: Yoke screws should be installed directly across from each other, not diagonally, and in holes furthest from the joint line. One yoke screw per one yoke bracket. YES Connect plug-together wiring. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 11 of 13

Step 9 - Closing Luminaires A. Close All s B. Secure Flange To Structure Spackle Flange Only Every 6" to 12" Reinstall all backplates by snapping into clips. Screws/Fasteners 1 Screws or fasteners: drywall - drywall screws, wood - wood screws, etc. Mud Guard (provided) Secure spackle flanges to wall/ceiling using appropriate screws or fasteners 1 for hard surface, per local building codes. Install the "mud guards" cardboard inserts to help prevent spackle and paint from getting into the luminaire. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 12 of 13 CONTINUED

Step 9 - Closing Luminaires C. Apply Spackle Spackle Flange Only D. Final Step - Replace Diffusers ID: 1 Mud Guard (provided) ID: 1 ID: 2 ID: 2 ID: 3 ID: 3 Spackle Putty Knife Spackle and paint over flanges up to luminaire edge. CAUTION: Careful not to drop spackle into luminaire. Immediately wipe off excess spackle that may have gotten onto luminaire edges. Perform all spackling and painting to walls and ceiling prior to removing "mud guards." Remove all mud guards. Remove diffusers from protective plastic bag. CAUTION: Wear gloves to keep diffuser surface clean. CRITICAL: Be sure to install correct diffuser to its corresponding luminaire ID. Install diffusers into luminaire body, ensuring they snap into place. Turn power on to luminaire. Note: All power connections to be installed to local/national codes by a Certified Electrician. Finelite, Inc. 30500 Whipple Road Union City, CA 94587-1530 (510) 441-1100 Fax: (510) 441-1510 www.finelite.com 13 of 13