GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Similar documents
MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

TRANSFORMER COM PANY. Dry Type Substation Transformers

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Liquid-Filled Transformers

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

Description. Features and Benefits

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

Dry-Type Transformers

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

T S 15KVA 1PH 240/480 Transformer

SECTION TRANSFORMERS

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

Federal Pacific Engineered and Specialty Transformer Catalog

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

Steps for Selecting the Proper Transformer

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

HPS Universal BUCK-BOOST TRANSFORMERS

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

(

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Energy Efficient Distribution Transformers

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

K Factor Power Transformers

Transformer Factory Testing

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

ULTRA-K Series 600K - he

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.1. Product Description

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

TMC Transformers TMC

7. INSPECTION AND TEST PROCEDURES

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

Section 2 Outdoor Voltage Transformers

CAST RESIN DRY TRANSFORMER

Basic Principles and Operation of Transformer

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

Electrical Design Process

Warehouse Stock Transformers

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

DTS ISOLATION TRANSFORMER SPECIFICATIONS

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Power-Sure 700. Technical Data TD158001EN. Contents

(2) New Standard IEEE P (3) Core : (4) Windings :

TRANSFORMER TECHNOLOGY GPT

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

Power Processor - Series 700F 10KVA to 150KVA

VI 3 - i TABLE OF CONTENTS

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Your Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Transformer Questions & Answers

Electrical Description

Jefferson Electric Inc Product Catalog JE901

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

Dry-type Transformer. High Reliability Maintenance-free Environmentally Friendly

Transformer Questions & Answers

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Convincing technology creates compact performance

Power Transformers Basics

Custom Power Supplies, Transformers, Chokes & Reactors

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

Basics of electrical transformer

Drive Isolation Transformers

What is a Transformer?

Transcription:

GE Ventilated Dry-Type Transformers Secondary Substation Transformers - 5 and 15kV Class

GE ventilated dry-type transformers are designed for indoor or outdoor applications in schools, hospitals, industrial plants, commercial buildings and any place requiring safe and dependable power. Ventilated dry-type transformers offer an economical solution and are extremely reliable when properly installed and maintained. General Construction Coils are vacuum-pressure-impregnated (VPI) with solventless polyester resin, ensuring complete impregnation of the windings and insulation. The finished VPI coils are incredibly strong, readily dissipate heat and are protected against moisture, dirt and most industrial contaminants. Ventilated dry-type winding designs vary depending on the voltage, basic impulse level (BIL) and current of the individual winding and/or application of the transformer. For all units, the insulation system will be 220 C regardless of the average winding rise. Vent Dry Transformer; standard arrangement, (HV left) with forced air cooling Safe, Convenient and Environmentally Sound Installations of ventilated dry-type transformers do not require a liquid confinement area, automatic fire extinguishing system or fire vault. Dry-type transformers use no insulating liquids, virtually eliminating the risk of local environment contamination and simplifying routine maintenance by eliminating the need to check, replace or clean liquid. Dry-type units are relatively lightweight and can be conveniently installed on upper floors, balconies, roof trusses or roofs. Insurance companies generally offer lower premiums for installations of dry-types than for liquid-filled transformers. Core and Coil internal assembly

Coils Generally, low voltage (LV) windings less than 2,400 volts are either multi-conductor barrel or sheet conductor types. Multi-conductor windings may be more economical and preferred in smaller kva low voltage applications in which the current and axial short circuit forces are relatively small. High voltage (HV) windings 2,400 volts or greater may be single-section barrel, multi-section barrel or disk types. Ventilated dry-type coils may be either round or rectangular through about 2,000 kva. Transformers larger than 2,000 kva generally are designed with round windings unless there are special considerations, such as limiting dimensions. Enclosure The standard indoor enclosure is NEMA 1, Category C construction. Enclosures are suitable for lifting, jacking, rolling or skidding with provisions for lifting from the transformer base. High voltage and low voltage ANSI ground pads are provided. The enclosure paint finish is neat, clean and highly resistant to corrosion. Metal surfaces are thoroughly cleaned of scale, oil, grease, rust and other foreign matter before painting. Unless specified otherwise, paint color shall be ANSI 61 (light gray). NEMA 3R outdoor enclosures are available for applications that prohibit indoor installation. Cores The transformer cores are constructed of non-aging, high grade, grain oriented silicon steel laminations with high magnetic permeability. Magnetic flux densities are kept well below the saturation point. Core laminations are free of burrs and stacked without gaps. Mitered and step-lap construction cores may be provided when specified. The core clamping brackets are designed to provide even distribution of clamping forces to the core yokes and legs. The core is electrically isolated except for the factory-installed core ground strap, which provides a single path from the core to ground. Outdoor NEMA 3R enclosure

Forced Air Cooling All units rated 750 kva and higher have provisions for adding fans, including capacity in all currentcarrying parts for the fan-cooled rating and capability to add a thermometer relay to control fans. When specified, the transformer shall be provided with fans to give a forced air-cooled rating of 33% above the self-cooled rating. Control wiring (wire markers included), a thermal sensor and a fan controller will be supplied. Vent-Dry Sound Levels: (db) Equivalent Self- Fan- Two Winding Cooled Cooled Base kva db db 500 60 N/A 750 64 67 1000 64 68 1500 65 69 2000 66 71 2500 68 71 3000 68 73 Product Coordination When specified, transformers can be close-coupled to a multitude of GE equipment, including but not limited to Power Break, AKD-8 Switchgear, POWER/VAC Switchgear, Limitamp Motor Control, SCP Switchboards, Spectra Series Switchboards, AV Switchboards, Motor Control Centers, Spectra Series Busway, and Medium Voltage Load Interrupter Switchgear (MVS). Typical Close-Coupled Reverse Arrangement (HV on Right) Load-Center Unit Substation with Ventilated Dry-Type Transformer Three-Phase Temperature Monitor Audio Sound Levels The transformer shall be designed to meet or exceed ANSI and NEMA sound levels for dry-type transformers. As an option, transformers designed at -3dB below ANSI and NEMA standard sound levels are available. x LV Outgoing Section x Transformer Section x HV Incoming Section x

Ventilated Dry-Type Case Outline Shown with High Voltage and Low Voltage Air Terminal Compartments HV ATC LV ATC H D W Approximate Enclosure Dimensions and Weights Based upon 15kV class, 150 C rise. Al windings kva Height Width* Depth Weight Inches Inches Inches lbs 225 90 56 50 2,350 300 90 56 50 2,650 500 90 64 50 3,950 750 90 72 50 4,650 1000 90 72 50 5,800 1500 90 90 50 8,100 2000 90 90 50 9,500 2500 100 100 60 10,650 3000 100 100 60 12,350 *Add 18 to width for each ATC. NOTES: 1. Coordination to GE Equipment may require Transition/Throats. Width may increase up to 42. 2. Depth dimension may increase approximately 4 to 8 each for outdoor NEMA 3R enclosures. 3. Dimensions may vary with special requirements. 4. Dimensions and weights are subject to change without notice and should not be used for construction purposes.

Dry-Type Standard Features Vacuum Pressure Impregnated (VPI) windings 80, 115, 150 C average winding rise ratings 60 Hz operation 220 C insulation system Aluminum or copper windings ANSI ground pads Core ground strap Indoor ventilated enclosure - NEMA 1 Paint ANSI 61 finish Provisions for future fans (750 kva & up) Provisions for lifting Removable front and rear panels Vibration isolating pads (2) 2 1 / 2 % full capacity taps above and below nominal Dry-Type Accessories or Options Electrostatic Shield Enclosure hinged panels Enclosure knockdown Fans for 133% FA kva rating Future fan wiring and control Ground bus - full length copper Impact indicator - Mechanical Outdoor enclosure NEMA 3R Paint polyurethane overcoat Screened ventilation openings Space heaters Temperature monitor/fan controller Thermostat for space heaters UL listing Special Design or Application Low loss designs Rectifier transformer designs Special ambient designs High overload capacity designs Special/low sound level designs 50 Hz designs Seismic zone IV designs Five-legged core designs Series/parallel windings HV Wye connection to LV Delta Retrofit to specific dimensions K-factor ratings Special Paint Testing Each transformer shall receive the following standard production tests in accordance with ANSI C57.12.90 Resistance test Polarity & phase relation test Turns ration test No-load loss & exiting current test Impedance and load-loss test Applied potential test Induced potential test Test results, when requested, are available by transformer serial number. In addition, the following special tests can be performed on each transformer in accordance with applicable ANSI standards at an additional cost. Temperature test Impulse test Sound test Insulation power factor test Partial discharge test Vent-Dry Basic Impulse Ratings Nominal Standard Option System HV BIL HV BIL LV BIL Voltage kv kv kv kv 1.2 10 30 10 2.5 20 30, 45 20 5.0 30 45, 60, 75 30 8.7 45 60, 75, 95 N/A 15.0 60 75, 95, 110 N/A For additional information contact your local GE Electrical Distribution and Control Salesperson. General Electric Company 41 Woodford Avenue, Plainville, CT 06062 1997 General Electric Company GE Electrical Distribution & Control DEA-051 0197 BL