Spectral distribution from end window X-ray tubes

Similar documents
DEVELOPMENT OF A WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE SPECTROMETER USING A MULTI-CAPILLARY X-RAY LENS FOR X-RAY DETECTION

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

DOUBLE MULTILAYER MONOCHROMATOR WITH FIXED EXIT GEOMETRY. H.Gatterbauer, P.Wobrauschek, F.Hegediis, P.Biini, C.Streli

MICRO XRF OF LIGHT ELEMENTS USING A POLYCAPILLARY LENS AND AN ULTRA THIN WINDOW SILICON DRIFT DETECTOR INSIDE A VACUUM CHAMBER

GUNSHOT RESIDUE INVESTIGATIONS USING TXRF

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER

Copyright -International Centre for Diffraction Data 2010 ISSN

MOXTEK S NEW ULTRA-LITE X-RAY SOURCES: PERFORMACE CHARACTERIZATIONS

A MONTE CARLO CODE FOR SIMULATION OF PULSE PILE-UP SPECTRAL DISTORTION IN PULSE-HEIGHT MEASUREMENT

TOWARDS FAST RECIPROCAL SPACE MAPPING

Applications of New, High Intensity X-Ray Optics - Normal and thin film diffraction using a parabolic, multilayer mirror

MICROFOCUSING X-RAY EQUIPMENT FOR THE LAB DIFFRACTOMETER

Atomic and nuclear physics

ON THE DETECTION LIMIT OF TEY (TOTAL ELECTRON YIELD) Maria F. Ebel, Horst Ebel and Robert Svagera

USING A CHARGE-COUPLED DEVICE (CCD) TO GATHER X-RAY FLUORESCENCE (XRF)AND X-RAY DIFFRACTION (XRD) INFORMATION SIMULTANEOUSLY

TOWARDS SUB-100 NM X-RAY MICROSCOPY FOR TOMOGRAPHIC APPLICATIONS

Multi-Element Analysis by Portable Total Reflection X-ray Fluorescence Spectrometer

ON THE ENERGY DEPENDENCE OF THE DETECTOR EFFICIENCY OF A Si-PIN DIODE

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Scintillation Counters

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

XRF Instrumentation. Introduction to spectrometer

High energy X-ray emission driven by high voltage circuit system

DESIGN OF EDXRF EQUIPMENT FOR THE NONDESTRUCTIVE STUDY OF PRINTS

X-RAY BACKSCATTER IMAGING: PHOTOGRAPHY THROUGH BARRIERS

Terahertz Radiation of a Low-inductance Discharge in Vacuum with Laser-plasma Initiation

X-ray Tube and Generator Basic principles and construction

X-rays in medical diagnostics

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Abstract. 1. Introduction

Components of Optical Instruments

CONFOCAL GRADED d-spacing MULTILAYER BEAM CONDITIONING OPTICS

SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES

Qualitative analysis tutorial for Tracer III SD and V+ data

Applications of Micro XRF for the Analysis of Traditional Japanese "Ainu" Glass Beads and other Artifacts

DESIGN AND MEASUREMENT WITH A NEW PORTABLE X-RAY CAMERA FOR FULL-FIELD FLUORESCENCE IMAGING

CHAPTER-2 INSTRUMENTATION AND METHODS OF DATA ANALYSIS

Seminar 8. Radiology S8 1

Explain what is meant by a photon and state one of its main properties [2]

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

Soft X-Ray Silicon Photodiodes with 100% Quantum Efficiency

New Detectors for X-Ray Metal Thickness Measuring

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

DUANE-HUNT RELATION AND DETERMINATION OF PLANCK S CONSTANT

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

Single-photon excitation of morphology dependent resonance

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

IDENTIFICATION OF PAINTING MATERIALS USED FOR MURAL PAINTINGS BY IMAGE ANALYSIS AND XRF

Method for digital particle spectrometry Khryachkov Vitaly

Lecture 18: Photodetectors

POLARIZATION FOR BACKGROUND REDUCTION IN EDXRF --- THE TECHNIQUE THAT DOES INDEED WORK

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

RIETVELD REFINEMENT OF POWDER DATA FROM MULTILAYER OPTICS

OPTIMIZING THE ELEMENTAL SENSITIVITY AND FOCAL SPOT SIZE OF A MONOLITHIC POLYCAPILLARY OPTIC USING MICRO-X-RAY FLUORESCENCE

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Optical Fiber Technology. Photonic Network By Dr. M H Zaidi

Observation of X-rays generated by relativistic electrons in waveguide target mounted inside a betatron

LYNXEYE XE-T. < 380 ev. Innovation with Integrity. Energy. Resolution. High-Resolution Position Sensitive Detector with Superb Energy Resolution XRD

High collection efficiency MCPs for photon counting detectors

K-edge subtraction X-ray imaging with a pixellated spectroscopic detector

Wide Field-of-View Fluorescence Imaging of Coral Reefs

FAST ELEMENTAL MAPPING WITH MICRO-XRF

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Gamma Spectrometer Initial Project Proposal

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

X-ray tube with needle-like anode

Fast Bunch Profile Monitoring with THz Spectroscopy of Coherent Radiation at FLASH.

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

Photonics and Optical Communication Spring 2005

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Skoog Chapter 1 Introduction

How Does One Obtain Spectral/Imaging Information! "

Lesson 2 Diffractometers

Low Cost Rolled X-ray Prism Lenses to Increase Photon Flux Density in Diffractometry Experiments

Components of Optical Instruments 1

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

A PORTABLE X-RAY APPARATUS FOR BOTH STRESS MEASUREMENT AND PHASE ANALYSIS UNDER FIELD CONDITIONS.

STATE-OF-THE-ART SILICON DETECTORS FOR X-RAY SPECTROSCOPY

Derivation of total filtration thickness for diagnostic x-ray source assembly

Monochromatic X-ray sources based on Table-top electron accelerators and X-ray tubes. A.P. Potylitsyn TPU, Tomsk, Russia

PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by

CHAPTER 7. Components of Optical Instruments

Experimental Competition

Silicon Photomultiplier

Supplemental Information

Peculiarities of the Hamamatsu R photomultiplier tubes

PHYSICS. Speed of Sound. Mr R Gopie

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Estimation of signal transfer property for wireless digital detector in different measurement schemes

Transcription:

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 393 Spectral distribution from end window X-ray tubes N. Broll 1, P. de Chateaubourg 2 1 FORTEX - E.N.S.A.I.S. 24, bld de la Victoire, 67084 STRASBOURG Cedex, France 2 UPVM - 61, av. du Gal de Gaulle, 94010 CRETEIL Cedex, France ABSTRACT Today little information still exists on spectra profiles emitted by x-ray tubes, although the development of mathematical matrix correction procedures for x-ray fluorescence analysis showed the demand of the knowlegde of accurate spectral intensity distribution from x-ray tubes. In this paper we present measured spectral intensity distributions from end window x-ray tubes (Au, Rh, Cu and Cr anodes) typically used in wavelength and energy dispersive spectrometers. The spectral distribution of the x-ray tubes measured with an energy dispersive method allows to compare the experimental data of the continuous spectra of the x-ray tube to a semiempirical expression based on the Kramers law. Furthermore, the knowlegde of different x-ray lines contributes to the total x-ray spectral distribution. INTRODUCTION In the quantitative analysis of elements by x-ray fluorescence techniques, it is essential to know the contribution of the continuous spectra to the excitation of the fluorescence lines relative to that excited d by characteristic lines of the excitation beam. Modern x-ray generators are still built around the Coolidge tube, i.e. vacuum tube in which electrons are emitted by an heated W filament (cathode), accelerated by high voltage and focused on a water-cooled metal target (anode). Electron bombardement of solid targets is the most usual method to generate x-rays represented by spectral distributions of x- ray photons. These spectral distribution consist of a continuous spectrum (due to the Bremsstrahlung) on which are superposed a few characteristic lines depending on the target element. Spectral intensity distributions from x-ray tubes show that the continuous component is far from being negligible; the continuous spectrum represents 30 to 70% of the total intensity which is composed of this continuous spectrum and the anode s characteristic lines. It is surprising that it was long considered that the continuous spectrum was described by the Kramers law, while this law concerns the x-ray inner generation by electrons and not the x-rays leaving the anode or tube s window. Before 1970, no discontinuities were reported due to the continuous spectrum s selfabsorption in the anode. Since 1968, the accurate spectral intensity distribution from x-ray tubes became more and more important for developing the fundamental parameter method. In these time new and more accurate measurements were realized. Important deviations between the experimental spectral distributions and the one given by Kramer s law were reported. These works were not carried on consequently, and therefore there exist only a few publications of which the most are principally devoted to former types of X-ray tubes. Up to now, no systematic study was carried out, although we know that the spectral distribution shape depends on the X-ray tube geometry. Figure 1 shows measured spectral distributions for different types of X-ray tubes. The shape of the spectral distributions can be explained by a theory based on electron transmission. However, this theory is too elaborate to apply. Therefore, experimental measurements and semi-empirical relations are preferred nowadays. 1

ISSN 1097-0002, Advances in X-ray Analysis, Volume 41 This document was presented at the Denver X-ray Conference (DXC) on Applications of X-ray Analysis. Sponsored by the International Centre for Diffraction Data (ICDD). This document is provided by ICDD in cooperation with the authors and presenters of the DXC for the express purpose of educating the scientific community. All copyrights for the document are retained by ICDD. Usage is restricted for the purposes of education and scientific research. DXC Website www.dxcicdd.com ICDD Website - www.icdd.com

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 394 Fig. 1 measured spectral distributions for different types of X-ray tubes EXPERIMENTAL METHODS Different methods have been used to measure spectral distributions. The first of these methods has been used by many authors assuming that the spectrum, obtained by X-ray scattering by an organic sample agreed with real tube s spectrum. Is difficult to fit such a spectrum to the real distribution. The exploitation of such a spectrum needs a lot of corrections. 2

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 395 Another method to study spectral distributions consists in exploiting spectra measured by an electronic microprobe, but again, results do not exactly match with reality. Furthermore, there exists two other experimental methods which allow to determine correctly the spectral distribution. The radiation at the exit of the tube is measured directly with a spectrometer, either wavelength or energy dispersive. Figure 2a,b represent the scheme of these experimental assemblies.these two methods also need corrections to link the measured x-ray intensity with x-ray intensity effectively emitted by the tube: Fig. 2a,b Schemes of the experimental assemblies Wavelength dispersion - analysing crystal reflectivity - detectors (scintillation and flow counters) efficiency - pulse heigth analysis - supression of higher order reflections - mylar window between detector transmisson - loss of counts due to the dead time of the detector - total spectrum reconstitution from measurements with different analysing crystals Energy dispersion - detector quantum yield - detector background - excape peaks - compton effect in the detector - pile-up peaks - interference of fluorescence lines due to the spectrometer s resolution 3

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 396 EXPERIMENTAL RESULTS Measurements have been realized using the energy dispersion method, which is more easy to handle. After corrections, we record results in a table where intensity measured is noted for different excitation voltages. A full spectrum can be expressed as a distribution N(E)dE, where N(E) is the number of accumulated counts corresponding to x-ray photon energies between E and E+dE. Since wavelength is inversely proportional to energy (λ=12.3981/e), dλ=-(12.3981/e 2 )de N(E) can be written as N(E)dE=N(λ)dλ where N(λ)=N(E)E 2 /12.3981. Measurements have been made on front end window tubes (Beryllium windows thickness of 125µm) used for Siemens SRS303 spectrometers. Au, Rh, Cr and Cu anodes were studied. Figures 3,4,5,6 represent spectral distributions of the continuous spectra for different excitation voltages. Fig 3. Spectral distribution of the continuous spectra of an Au tube for different excitation voltages 4

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 397 Fig 4. Spectral distribution of the continuous spectra of a Cu tube for different excitation voltages Fig 5. Spectral distribution of the continuous spectra of a Rh tube for different excitation voltages 5

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 398 Fig 6. Spectral distribution of the continuous spectra of a Cr tube for different excitation voltages We note for the Au tube, discontinuities of absorption for M shells can not be seen, although characteristic lines are detected. This is due to the difficulty to obtain an accurate measurement in the discontinuity area because, first, the superposition of intense characteristic lines and second the poor detector resolution at low energies. In practice, this imprecision is negligible, since characteristic lines are widely prevalent. Fig 7 accounts for continous spectra importance according to the tube s target for the same excitation voltage (here e.g. 40 kev). 6

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 399 Fig 7. Continous spectra according to the tube s target for the same excitation voltage (40 kev). We note that these experimental results can be used in order to fit the data to the semi-empirical equation: λ q 1 n N( λ) ( 1) exp( Q µ, )exp( 2 A λ µ Be, λ ρ λ λ 0 Be d) The first term agrees with the Kramers law, modified by the exponent q. The second term represents the radiation self absorption in the target, where the coefficients Q and n account for the mean depth electrons penetration in the target. Finally, the third term expresses the x-ray absorption by the beryllium window. Q, n and q are fitted by a reiterative process until variations between theoretical and experimental graphs become a minimum. For example, for an excitation voltage of 50 kev, we obtain following coefficients ( n is kept constant to 1): 7

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 400 Tube q Q Cr 1.502 0.00127 Cu 1.491 0.00144 Rh 1.426 0.00096 Au 1.206 0.00041 CHARACTERISTIC LINES We have measured Kα, Kβ lines of Cr and Cu tubes, L lines of Rh tube and Lα, Lβ, Lγ, Ll and M lines of Au tube. Figure 8 represents measured intensity evolution for each characteristic line as a function of the exciting voltage. Fig. 8 Measured intensity evolution for each characteristic line as a function of the exciting voltage We have represented in table 1 these characteristic lines leaving the x-ray tubes, at different voltages, that is, after all corrections required by the energy-dispersive method. Results are expressed in per cent in respect to the total spectrum (Bremsstrahlung plus characteristic lines) 8

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 401 [kv] 20 25 30 35 40 45 50 Cr tube Brems. 34.09 31.10 29.60 28.02 25.73 26.53 26.84 K α 57.92 60.54 61.64 63.18 65.15 64.45 64.23 K β 7.99 8.36 8.76 8.80 9.12 9.02 8.93 Cu tube Brems. 58.41 51.64 47.27 44.97 43.64 41.45 39.08 K α 36.52 42.50 46.38 48.49 49.59 51.44 53.42 K β 5.07 5.86 6.35 6.54 6.77 7.11 7.50 Rh tube Brems. 55.82 54.73 55.07 55.07 53.57 54.82 55.21 L 44.18 54.27 44.28 43.47 43.88 41.41 39.74 K α 0.55 1.25 2.16 3.21 4.21 K β 0.10 0.21 0.40 0.57 0.84 Cr tube Brems. 71.79 69.19 67.01 65.36 63.97 63.76 63.39 M a,b 21.80 19.45 17.54 15.78 14.47 12.83 11.97 Mn4 0.51 0.38 0.34 0.23 0.26 0.21 0.21 L l 0.16 0.37 0.42 0.52 0.60 0.64 0.64 L α 3.71 6.45 8.70 10.46 11.90 12.72 13.37 L β 1.87 3.80 5.26 6.72 7.68 8.60 9.22 Lγ 0.15 0.37 0.72 0.93 1.12 1.24 1.19 Table 1 Characteristic line intensities leaving the X-ray tubes at different voltages Figure 9 illustrates these variations in per cent as a function of the exciting voltage for each X-ray tube. 9

Copyright ISSN (C) 1097-0002, JCPDS-International Advances in X-ray Centre Analysis, for Volume Diffraction 41 Data 1999 402 Fig. 9 Variations of the characteristic line intensities in per cent as a function of the exciting voltage CONCLUSION Our collected spectral data are used in different software packages with fundamental parameter coefficients method. It is interesting to know the importance of different x-ray lines in order to determine their contributions to element analysis. In practice, the accuracy of the results is widely satisfied. In order to have more accurate measurements, it will be necessary to measure the discontinuities area (at low energies) by energy and wavelength dispersive method, and then to adjust the two measured spectra. Furthermore, it will be possible to realize a statistical study for determine the reliability of this method (exactness). We finally note that the spectral distribution does not remain constant during the x-ray tube lifetime. Characteristics can change by ageing and impurities. REFERENCES 1. H.A. Kramers, Philo. Mag. 46, 836 (1923) 2. C.T. Ulrey, Phys. Rev. 11,401 (1918) 3. H. Kulenkampff, Ann. der Phys. 69, 548 (1922) 4. H. Kulenkampff, L. Schmidt, Ann. der Phys. 43, 494 (1943) 5. J.W. Criss, L.S. Birks, Anal. Chem 40, 1080 (1968) 6. J.V. Gilfrich, L.S. Birks, Anal. Chem 40, 1077 (1968) 7. D.B. Brown, J.V.Gilfrich, M.C. Peckerar, J. Appl. Phys. 46, 4537 (1975) 8. T.C. Loomis, H.D. Keith, X-ray Spectrom. 5, 104 (1976) 9. N. Broll, X-ray Spectrom. 15, 271 (1986) 10. T.Arai, T. Shoji, K. Omote, Adv in X-ray Analys 29, 413 (1985) 11. R. Görgl, P. Wobrauschek, P. Kregsamer, C. Streli, X-ray Spectrom. 21, 37 (1992) 12. R.O. Müller, Spektrochemische Analysen mit Röntgenfluoreszenz, Oldenbourg, Munich (1967) 13. P.A. Pella, L. Feng, J.A. Small, X-ray Spectrom. 14, 125 (1985) 14. R. Tertian, N. Broll, X-ray Spectrom. 13, 134 (1984) 15. N. Broll, R. Tertian, X-ray Spectrom. 12, 30 (1983). 10