IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual. Agilent Technologies June 2012

Similar documents
Keysight Technologies Innovative Passive Intermodulation (PIM) and S-parameter Measurement Solution with the ENA. Application Note

Agilent E4980A Precision LCR Meter. Dielectric Constant Measurement Program Operation Manual

Keysight Technologies Basics of RF Ampliier Measurements with the E5072A ENA Series Network Analyzer

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

External Source Control

Keysight Technologies Accurate Mixer Measurements Using the ENA RF Networks Analyzers Frequency-Offset Mode. Application Note

Keysight Technologies Amplifier and CW Swept Intermodulation - Distortion Measurements using the PNA Microwave Network Analyzers.

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Keysight Technologies PNA-X Series Microwave Network Analyzers

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Keysight Technologies E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Agilent. E5071C ENA Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

VVM measurement with E5061B for replacing 8508A vector voltmeter. May 2013 Agilent Technologies

Agilent Technologies PSA Series Spectrum Analyzers Test and Adjustment Software

Advanced Test Equipment Rentals ATEC (2832)

Exercise 5: Power amplifier measurement

Agilent E5072A ENA Series Network Analyzer

Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Millimeter Signal Measurements: Techniques, Solutions and Best Practices

Keysight 2-Port and 4-Port PNA-X Network Analyzer

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

Keysight Technologies E5072A ENA Series Network Analyzer 30 khz to 4.5/8.5 GHz. Data Sheet

Advanced Measurement Techniques for RF Amplifiers Using Unique Functions of the Agilent E5071C ENA. Application Note

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Signal Analysis Measurement Guide

Keysight Technologies E5071C ENA Network Analyzer

IMD and RF Power Measurements with the Keysight PNA-X N5249A

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Network Analysis Back to Basics

Keysight Technologies Multiport Solutions for E5071C ENA RF Network Analyzers Using External Switches. Application Note

Keysight Technologies PNA Microwave Network Analyzers

UM User manual for the BGU7004 GPS LNA evaluation board. Document information. Keywords LNA, GPS, BGU7004. Abstract

Introduction. Part 1. Introduction...2

Demo Circuit DC550A Quick Start Guide.

Keysight Technologies E5072A ENA Series Network Analyzer 30 khz to 4.5 /8.5 GHz. Data Sheet

Agilent Technologies Gli analizzatori di reti della serie-x

Keysight Technologies Nonlinear Vector Network Analyzer (NVNA) Breakthrough technology for nonlinear vector network analysis from 10 MHz to 67 GHz

RF, Microwave & Wireless. All rights reserved

Keysight 2-Port and 4-Port PNA-X Network Analyzer

E5071C ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

Agilent PNA Microwave Network Analyzers

9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

S3602A/B Vector Network Analyzer Datasheet

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Introduction. Part 1. Introduction...2

Keysight Technologies PNA Family Microwave Network Analyzers

PLANAR 814/1. Vector Network Analyzer

Overcoming Mixer Measurement Challenges

Understanding RF and Microwave Analysis Basics

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 678A 40MHZ TO 900MHZ DIRECT CONVERSION QUADRATURE DEMODULATOR

Advanced Test Equipment Rentals ATEC (2832)

Power Meter. Measurement Guide. for Anritsu RF and Microwave Handheld Instruments BTS Master Site Master Spectrum Master Cell Master

RIGOL. User s Guide. DSA800 Options and Accessories. May RIGOL Technologies, Inc.

How do I optimize desired Amplifier Specifications?

Advanced Product Design & Test for High-Speed Digital Devices

Keysight Technologies External Source Control X-Series Signal Analyzers Option ESC. Demo Guide

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

RIGOL. User s Guide. DSA800 Options and Accessories. Dec RIGOL TECHNOLOGIES, INC.

Configuration of PNA-X, NVNA and X parameters

DEMO MANUAL DC2153A LTC MHz to 1700MHz Differential ADC Driver/IF/RF Amplifier. Description

PLANAR S5048 and TR5048

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1455A 5MHZ TO 1600MHZ HIGH LINEARITY DIRECT QUADRATURE MODULATOR LTC5598 DESCRIPTION

Spectrum Analyzers 2680 Series Features & benefits

PXIe Contents CALIBRATION PROCEDURE

Agilent PNA Family Microwave Network Analyzers

HP Archive. This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web!

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

S3602C Vector Network Analyzer Datasheet

Reconfigurable 6 GHz Vector Signal Transceiver with I/Q Interface

3.3V Supply, R1 = 2kΩ

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

30 MHz to 6 GHz RF/IF Gain Block ADL5544

Keysight Technologies E5080A ENA Series Network Analyzer. - 9 khz to 4.5/6.5/9 GHz

SKY Preliminary Data Sheet

3.3 V, SILICON MMIC MEDIUM OUTPUT POWER AMPLIFIER. Part Number Order Number Package Marking Supplying Form C3V

QuickSyn Frequency Synthesizers

PARAMETER CONDITIONS TYPICAL PERFORMANCE Operating Supply Voltage 3.1V to 3.5V Supply Current V CC = 3.3V, LO applied 152mA

Agilent N5250A PNA Millimeter-Wave Network Analyzer 10 MHz to 110 GHz

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

Measuring Non-linear Amplifiers

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight 2-Port and 4-Port PNA Network Analyzer

Pulsed Measurement Capability of Copper Mountain Technologies VNAs

Keysight Technologies Ampliier Linear and Gain Compression Measurements with the PNA Microwave Network Analyzers. Application Note

Gain Compression Simulation

SA620 Low voltage LNA, mixer and VCO 1GHz

Maxim Integrated Products 1

MAAP STD Power Amplifier, 2 W GHz Rev. V2 Features Functional Schematic Description Pin Configuration2 Ordering Information1

30 MHz to 6 GHz RF/IF Gain Block ADL5611

DEMO MANUAL DC2349A LTC5586 6GHz High Linearity I/Q Demodulator with Wideband IF Amplifier DESCRIPTION BOARD PHOTO

Experiment 12 - Measuring X-Parameters Using Nonlinear Vector Netowrk Analyzer

Impedance 50 (75 connectors via adapters)

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

DAC1627D Demo boards Quick Start v2

Transcription:

IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual Agilent Technologies June 2012 1

Important Notice Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Agilent Technologies. Microsoft, MS-DOS, Windows, Visual C++, Visual Basic, VBA and Excel are registered trademarks of Microsoft Corporation. Java is registered trademark of Sum Microsystems Corporation. Copyright 2009-2011 Agilent Technologies Sample Program The customer shall have the personal, non-transferable rights to use, copy, or modify SAMPLE PROGRAMS in this manual for the customer s internal operations. The customer shall use the SAMPLE PROGRAMS solely and exclusively for their own purpose and shall not license, lease, market, or distribute the SAMPLE PROGRAMS or modification of any part thereof. Agilent Technologies shall not be liable for the quality, performance, or behavior of the SAMPLE PROGRAMS. Agilent Technologies especially disclaims any responsibility for the operation of the SAMPLE PROGRAMS to be uninterrupted or error-free. The SAMPLE PROGRAMS are provided AS IS. AGILENT TECHNOLOGIES DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Agilent Technologies shall not be liable for any infringement of any patent, trademark, copyright, or other proprietary right by the SAMPLE PROGRAMS or their use. Agilent Technologies does not warrant that the SAMPLE PROGRAMS are free from infringements of such rights of third parties. However, Agilent Technologies will not knowingly infringe or deliver software that infringes the patent, trademark, copyright, or other proprietary right of a third party. 2

Contents Introduction What is intermodulation distortion (IMD)? IMD measurement solution IMD measurement wizard for the E5072A Operation Manual Measurement Examples Summary 3

What is intermodulation distortion (IMD)? A measure of nonlinearity of amplifiers. Two or more tones applied to an amplifier and produce additional intermodulation products. The DUT s output will contain signals at the frequencies: n*f1 +m *F2. P(F1) DeltaF P(F2) IM3 relative to carrier (dbc) F_IMD = n * F1 + m * F2 P(2*F1-F2) ex.) Lo F_IM3 = 2 * F1 - F2 Hi F_IM3 = 2 * F2 - F1 Lo F_IM5 = 3 * F1-2 * F2 Hi F_IM5 = 3 * F2-2 * F1 Lo F_IM7 = 4 * F1-3 * F2 Hi F_IM7 = 4 * F2-3 * F1 2*F1-F2 F1 F2 2*F2-F1 Frequency 4

Third-order Intercept Point (IP3) The third-order intercept point (IP3) or the third-order intercept (TOI) are often used as figures of merit for IMD. Output power (dbm) P(F1) P(F2) OIP3 IM3 relative to carrier (dbc) P(2*F1-F2) DeltaF Fundamental (Slope 1:1) Third-order product (Slope 1:3) 2*F1-F2 F1 F2 2*F2-F1 Frequency P(F1): Power level of low tone P(F2): Power level of high tone P(2*F1-F2): Power level of low-side IM3 signal P(2*F2-F1): Power level of high-side IM3 signal IIP3 Input power (dbm) IP3 can be calculated by the equation using low-side IM3: IP3 (dbm) = P(F1) + (P(F2) - P(2*F1-F2)) / 2 When high-side IM3 is used, the equation is: IP3 (dbm) = P(F2) + (P(F1) - P(2*F2-F1)) / 2 5

Intermodulation Distortion Solution with ENA 2x SG + SA SG + ENA Using two SGs and a SA with CW signals. It requires a controller to synchronize instruments. If many frequencies must be tested, test time is increased dramatically. ENA with frequency-offset mode (FOM) option can set different frequencies at the source and receiver. Real-time swept frequency IMD measurements can be performed. Source power calibration and receiver calibration is available with VNA for accurate absolute power measurements. 6

IMD Measurement Wizard for the E5072A Key Features: Measurement macro running on the E5072A with intuitive GUI Quick setup of two-tone IMD measurements Control all necessary equipments from E5072A MXG (connected via GPIB/USB interface) Power meter & sensor (connected via GPIB/USB interface) USB power sensor (connected directly to the ENA s USB port) Guided calibration wizard Various measurement sweep types Fixed F1 and Swept F2 Sweep Fc (center frequency of main tones) Sweep DeltaF (delta frequency of main tones) Various IMD measurement parameters Available at: www.agilent.com/find/enavba Absolute power of fundamental tones (in dbm) Power levels of IMD products (absolute in dbm), Low or High-side IM (3rd, 5th, 7th) Calculated third-order intercept point (IP3) 7

IMD Measurement Wizard Overview Introduction Peripherals Setup (SG, Power sensor) Stimulus Parameter Setup (IM order, frequency, NOP, IFBW etc.) Calibration (Receiver cal) Calibration (Power Cal) Measurement Result Pout (F1 from SG) Pout (F2 from ENA) P(IM) IP3 8

IMD Measurement Wizard Measurement type Introduction 1. Fixed F1, Swept F2 2. Sweep fc (sweep center frequency between the two main tones) Three different sweep types are available. 3. Sweep DeltaF (sweep delta frequency between the two main tones) 9

IMD Measurement Type 1. Fixed F1, Swept F2 One of the main tones from the SG is fixed at a certain frequency (F1), while the other F2 from the ENA s source is swept. (1-1) Lo IM (Fixed F1, downward-swept F2) (1-3) Hi IM (Fixed F1, upward-swept F2) IM Main Tones Main Tones IM F 1 F 2 F 1 F 2 F IM F IM F b_rcv (1-2) Lo IM (Fixed F1, upward-swept F2) IM Main Tones F 1 F 2 F b_rcv (1-4) Hi IM (Fixed F1, downward-swept F2) Main Tones IM F 2 F 1 F IM F IM F b_rcv F b_rcv 10

IMD Measurement Type 2. Sweep fc Stimulus setup Measurement Result P(F1, SG) P(F2, ENA) P (Lo IM3) OIP3 Center frequency of the main tones is swept in the frequency range, while the delta frequency is fixed. 3rd, 5th, or 7th-order IM product can be tested for either high-side or low-side. P(Lo IM3) P(F1) P(F2) Output power of the main tones and IM power level is displayed to calculate output IP3 of the DUT. 11

IMD Measurement Type 3. Sweep DeltaF Stimulus setup Measurement Result P(F1, SG) P(F2, ENA) P (Lo IM3) OIP3 Delta frequency between the main tones is swept in the frequency range, while the center frequency is fixed. 3rd, 5th, or 7th-order IM product can be tested for either high-side or low-side. P(Lo IM3) P(F1) P(F2) Output power of the main tones and IM power level is displayed to calculate output IP3 of the DUT. 12

Required Equipments Model Description Note E5072A N5181A E5072A ENA Series Network Analyzer (with configurable test set) MXG RF analog signal generator Option 008 (frequency-offset mode) must be installed. (*1) With the firmware revision 1.01 or later. An external generator is used as a second source for the main tone. U200x Series USB power sensor Necessary for accurate absolute measurements using the E5072A s receiver. Can be directly connected to the E5072A s USB port. Other power sensors/meters supported for the E5072A are listed in the E5072A s webhelp. (link) 82357B USB/GPIB interface Necessary to control an external SG or power meter over GPIB from the E5072A firmware. *1: For more details on the E5072A s options, refer to the E5072A configuration guide, part number 5990-8001EN. (http://cp.literature.agilent.com/litweb/pdf/5990-8001en.pdf) 13

Operation Manual 14

Operation Manual Launch program Save the wizard program in the E5072A Visit: www.agilent.com/find/enavba Go to ENA IMD Measurement Wizard Page Download E5072AIMDWizard_xxxx.zip and unzip the file. Copy E5072AIMDWizard_xxxx.vba under D:/VBA/ of the E5072A s directory. Note: xxxx is the revision number of the wizard program. Launch the wizard program [Macro Setup] > Load & Run Select E5072AIMDWizard_xxxx.vba * The main window shows up. Note: Be sure to preset the E5072A and SG manually before launching the wizard program. 15

Operation Manual Measurement procedure 1. Setup peripherals Setup SG Setup power meter / sensor (GPIB or USB) 2. Setup measurement parameters Select IMD sweep types 1. Fixed F1, Swept F2 2. Sweep fc (center frequency) 3. Sweep DeltaF (delta frequency) Setup stimulus parameters 3. Perform calibration Receiver calibration Power calibration for main tones (SG & ENA) 4. Connect DUT and perform measurement 16

Operation Manual 1. Setup peripherals (SG) 2 1 1 1. Press Setup SG Control Necessary to setup an external SG (i.e. Agilent MXG N5181A) which is connected to the ENA via USB/GPIB interface (i.e. 82357B). 1. Enter the SG s GPIB address 2. Press Check Connection When the SG is connected to the ENA successfully, Connected is displayed. 3. Press Return 3 17

Operation Manual 1. Setup peripherals (Error: SG - Not connected) When the correct GPIB address of the SG is not entered, the error message is shown Warning: No SG discovered after pressing Check Connection. Not connected is displayed in the SG setup window. 18

Operation Manual 1. Setup peripherals (Power sensor via GPIB or USB) 1 1 1. Press Setup PS Control Necessary to setup a power sensor which is connected to the ENA by either the USB/GPIB interface (i.e. 82357B) or the ENA s USB port. 1. Select tab, Power Meter & Power Sensor (GPIB) or USB Power Sensor (USB) 19

Operation Manual 1. Setup peripherals (Power sensor via GPIB) Setup for power meter connected via GPIB/USB interface (i.e. Agilent 82357B) 1 3 2 1 2 3 1. Select tab, Power Meter & Power Sensor 2. Enter the GPIB address of the power meter 3. Press Check Connection When the power meter is connected to the ENA successfully, Connected is displayed. 1. Select Channel 2. Perform zeroing of the sensor (optional) 3. Press Return 20

Operation Manual 1. Setup peripherals (Error: Power Meter - Not connected) When the power meter is not connected or correct GPIB address of the power meter is not entered, the error message is shown Warning: No Power Meter discovered after pressing Check Connection. Not connected is displayed in the setup window. 21

Operation Manual 1. Setup peripherals (Power sensor via USB) Setup for USB power sensor (i.e. Agilent U2000 series) 1 2 3 1 2 1. Select tab, USB Power Sensor 2. Select the serial number of the connected USB power sensor 3. Press Check Connection When the power sensor is connected to the ENA successfully, Connected is displayed in the setup window. 1. Perform zeroing of the sensor (optional) 2. Press Return 22

Operation Manual 1. Setup peripherals (Error: Power Sensor - No Devices) If the USB power sensor is not connected to the E5072A, the serial number is not displayed in the pull-down menu. 23

Operation Manual 1. Setup peripherals When the both SG and power sensor are connected to the E5072A successfully, the measurement sweep types can be selected. 24

Operation Manual 2. Setup measurement parameters 1. Fixed F1, Swept F2 1 2 3 1 4 5 1. Press Fixed F1, Swept F2 One of the main tones is fixed at a specific frequency, while the other main tone is swept in the frequency range. 1. Select sweep type 2. Select IM order (3rd, 5th, or 7th) 3. Enter main tones frequency, NOP 4. Select IFBW for main tones & IM tone 5. Press Next 25

Operation Manual 2. Setup measurement parameters 2. Sweep fc 1 2 1 1. Press Sweep fc Center frequency of the main tones is swept in the frequency range, while the delta frequency is fixed. 1. Select IM order (3rd, 5th, or 7th), Hiside or Low-side. 2. Enter center frequency (fc), delta frequency (DeltaF), and NOP 3. Select IFBW for main tones & IM tone 4. Press Next 3 4 26

Operation Manual 2. Setup measurement parameters 3. Sweep DeltaF 1 2 1 1. Press Sweep DeltaF Delta frequency between the two main tones is swept in the frequency range, while the center frequency is fixed. 1. Select IM order (3rd, 5th, or 7th), Hiside or Low-side. 2. Enter center frequency (fc), delta frequency (DeltaF), and NOP 3. Select IFBW for main tones & IM tone. 4. Press Next 3 4 27

Operation Manual 2. Setup measurement parameters (Error: Frequency out of range) When the entered frequency value is out of the specification of the E5072A, the frequency is highlighted in red in the measurement channels. In this case, it is necessary to reenter the correct frequency range in the stimulus parameter setup. 28

Operation Manual 3. Perform calibration (Receiver cal) Note: Power calibration is recommended before receiver calibration to characterize the E5072A s receivers with calibrated source power for accurate absolute measurements. 2 1 2 1 29 3 1. Connect the power sensor to the E5072A s port 1 2. Enter Tolerance and Max Iteration for power calibration Measurement sweep of power calibration is continued until the power is adjusted within the accuracy tolerance or maximum iteration is met. 3. Press Take Cal Sweep Power calibration is performed for the channel 1,2 and 3 respectively. The button is highlighted in blue after the calibration is completed. 3 4 1. Connect the E5072A s port 1 and port 2 with a thru adapter 2. Select Receiver B 3. Press Take Cal Sweep The button is highlighted in blue and Corrected is shown in the status cell after the calibration is completed. 4. Press Next

Operation Manual 3. Perform calibration (Error: Power meter not settled) When the power sensor is NOT connected to the E5072A s port 1, the error message, -200: Execution error and Power meter not settled are displayed. The power calibration is aborted automatically. 30

Operation Manual 3. Perform calibration (Power cal for main tones) Power calibration is performed for the main tones from the ENA and SG to ensure accurate power levels at the DUT s input. Different power levels can be set for the frequency ranges. 1 2 1 3 2 3 31 1. Connect the combiner / E5072A / SG / power sensor 2. Enter Target power, Tolerance, and Max Iteration for power calibration of the main tone from the E5072A 3. Press Take Cal Sweep The button is highlighted in blue after the calibration is completed. 1. Enter Target power, Tolerance, and Max Iteration for power calibration of the main tone from the SG 2. Press Take Cal Sweep Note power calibration for the SG is performed only for the last frequency point. The button is highlighted in blue after the calibration is completed. 3. Press Next

Operation Manual 3. Perform calibration (Error - Power can not be adjusted) When the power level can not be adjusted within the accuracy tolerance during power calibration, the error message will be displayed. In this case, it is necessary to set the wider tolerance for the target power level. 32

Operation Manual 4. Connect DUT and perform measurement 1 1 2 1. Connect the DUT 2. Press Done All the necessary setup is done and ready to measure IMD of the DUT. 1. Measurement window is displayed on the E5072A screen. 33

Operation Manual 4. Connect DUT and perform measurement Measurement window Measurement window (with frequency information) 1 2 1. Press Single to trigger measurement once Press Cont. to perform continuous sweep measurements and press *Hold to hold measurements. 2. Press Exit to exit the program When Show Frequency Setup box is checked, the frequency range of main tones and IM product is displayed. 34

Operation Manual 4. Connect DUT and perform measurement Measurement result (Sweep fc) Frequency range P(F1) P(F2) P(Lo IM3) Ch 1 Ch 2 P(F1) P(F2) DUT Ch 3 Ch 4 OIP3 P(Lo IM3) Ch 1: P(F1) Output power of main tone frequency from SG (in dbm) Ch 2: P(F2) Output power of main tone frequency from E5072A (in dbm) Ch 3: P(IM) Power of IM product (in dbm) Ch 4: OIP3 Calculated OIP3 (in dbm) IP3 (dbm) = P(F1) + (P(F2) - P(2*F1-F2)) / 2 IP3 (dbm) = P(F2) + (P(F1) - P(2*F2-F1)) / 2 Output power of main tones and IM product is measured by the absolute measurement using the E5072A s receiver B. Output-referred IP3 (OIP3) is calculated and displayed in the channel 4 of the E5072A. 35

Measurement Examples 36

DUT for Demo DUT: The amplifier included in the E5072A s demo kit is used for measurements. Mini-Circuits: ZRL-2400LN+ (Agilent P/N: 0955-2330) *Data sheet is available at: http://www.minicircuits.com/pdfs/zrl-2400ln.pdf S-parameters: 500 M to 6 GHz, IFBW = 1 khz, Power level = -30 dbm, Full 2-port Cal 37

Test Configuration 1 Using the external combiner Configuration - Test setup USB/GPIB Interface (i.e. 82357B) GPIB MXG REF IN USB E5072A REF OUT Attenuator (Optional) Combiner DUT LPF (Optional) USB/GPIB interface (i.e. Agilent 82357B) is necessary to control the SG from the ENA firmware. 10 MHz reference is connected between the instruments. A low-loss and high-isolation combiner is recommended. An optional LPF is needed to eliminate source harmonics from the ENA. An optional attenuator is needed to protect ENA s receiver. 38

Measurement Example E5072A Receiver IP3 Measurement result (Sweep DeltaF) DUT: Thru. Pin (F1) = Pin (F2) = 0 dbm, IFBW = 10 Hz P(Lo IM3) P(F1) P(F2) Ch 1: Pout (@ Main tone frequency from SG, in dbm) P(F1) P(F2) Ch 2: Pout (@ Main tone frequency from ENA, in dbm) Ch 3: Power of IM product (@ Lo IM3, in dbm) P(Lo IM3) IP3 Ch 4: Calculated IP3 (in dbm) IP3 (dbm) = P(F1) + (P(F2) - P(2*F1-F2)) / 2 The E5072A receiver s IP3 can be determined by connecting a thru adapter between the port 1 and port 2, injecting a two-tone stimulus and measuring the power of the two tones and the 3rd IM product. The receiver IP3 is approx. +40 dbm in the frequency range. 39

Test Configuration 2 Using the internal bridge as a combiner The E5072A s internal bridge can be used as a combiner for two-tones. No external combiner is required in the test setup. Configuration - Test setup E5072A Block Diagram GPIB MXG REF IN USB E5072A CPLR ARM REF OUT R1 A B R2 USB/GPIB Interface (i.e. 82357B) Port 1 Port 2 LPF (optional) LPF CPLR ARM (< +12 dbm) Attenuator (Optional) DUT SG < -14 dbm (for the SG tone) DUT Input power at the port ( CPLR ARM ) should be at least below +12 dbm as the damage level of the input is +15 dbm. Input power at the DUT is below -14 dbm for the main tone from the SG due to the coupling factor (i.e. 26 db) of the E5072A s internal bridge. 40

RCVR R1 IN SOURCE OUT SOURCE OUT CPLR THRU CPLR ARM RCVR A IN RCVR B IN CPLR ARM CPLR THRU SOURCE OUT SOURCE OUT RCVR R2 IN E5072A Block Diagram Source Solid-state Attenuator (65 db) SPDT Switch R1 R2 Mechanical Step Attenuator (60 db, 10 db step) A B Mechanical Step Attenuator (60 db, 10 db step) Bias-Tee Bias-Tee Port 1 Port 2 REF 1 REF 2 41

Measurement Example Using the internal bridge Measurement result (fixed F1, swept F2) DUT: RF amp. Pin (F1) = Pin (F2) = -20 dbm, IFBW = 1 khz Ch 1: Pout (@ Main tone frequency from SG (CW), in dbm) P(F1, CW) P(F2) Ch 2: Pout (@ Main tone frequency from ENA, in dbm) Ch 3: Power of IM product (@ Lo IM3, in dbm) P(Lo IM3) OIP3 Ch 4: Calculated OIP3 (in dbm) IP3 (dbm) = P(F2) + (P(F1) - P(2*F2-F1)) / 2 Output power of the main tones and IM power level is displayed to calculate output IP3 of the DUT. 42

Measurement Example Using the internal bridge Measurement result (Sweep fc) DUT: RF amp. Pin (F1) = Pin (F2) = -20 dbm, IFBW = 1 khz P(Lo IM3) P(F1) P(F2) Ch 1: Pout (@ Main tone frequency from SG, in dbm) P(F1) P(F2) Ch 2: Pout (@ Main tone frequency from ENA, in dbm) Ch 3: Power of IM product (@ Lo IM3, in dbm) P(Lo IM3) OIP3 Ch 4: Calculated OIP3 (in dbm) IP3 (dbm) = P(F1) + (P(F2) - P(2*F1-F2)) / 2 Output power of the main tones and IM power level is displayed to calculate output IP3 of the DUT. 43

Measurement Example Using the internal bridge Measurement result (Sweep DeltaF) DUT: RF amp. Pin (F1) = Pin (F2) = -20 dbm, IFBW = 1 khz P(Lo IM3) P(F1) P(F2) Ch 1: Pout (@ Main tone frequency from SG, in dbm) P(F1) P(F2) Ch 2: Pout (@ Main tone frequency from ENA, in dbm) Ch 3: Power of IM product (@ Lo IM3, in dbm) P(Lo IM3) OIP3 Ch 4: Calculated OIP3 (in dbm) IP3 (dbm) = P(F1) + (P(F2) - P(2*F1-F2)) / 2 Output power of the main tones and IM power level is displayed to calculate output IP3 of the DUT. 44

Resources Configuration Guide (5990-8001EN) Data Sheet (5990-8002EN) Quick Fact Sheet (5990-8003EN) Technical Overview (5990-8004EN) Application Note High-power measurement using the E5072A (5990-8005EN) Basics of RF amplifier measurements with the E5072A (5990-9974EN) ENA Series: www.agilent.com/find/ena E5072A Product page: www.agilent.com/find/e5072a 45