MRG 512-PRO PQ Flex Mobile universal measurement device Supplementary description to the operation manual UMG 512-PRO

Similar documents
MRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

Current / residual current and voltage transformers. Current / residual current and voltage transformers

UMG 509-PRO Power Quality Analyser User manual and technical data Part no Doc. no

Accessories. Accessories

UMG 96 RM-E Residual current monitoring (RCM) Power Analyser Operating instructions and technical data

UMG 512-PRO Power Quality Analyser User manual and technical data Part no Doc. no d 01/2018

MultiMeter-Pocket CAT III 1000 V

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

UMG 512 Operation manual and technical data

Transienten. Datenspeicher

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

SAFETY AND OPERATING MANUAL

MAVOWATT 4 Multifunction Power Meter

printed pages will not be updated

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DS4012 DOUBLE INSULATION. IMPORTANT: Read Before Using.

The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off.

Power supply CP-D 24/4.2 Primary switch mode power supply

Electric Staple/Nail Gun

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

UMG 96 RM-EL Power Analyser Operating instructions and technical data

TE 7-C. English. Printed: Doc-Nr: PUB / / 000 / 03

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

GENERAL OPERATIONAL PRECAUTIONS

User Manual Digital Multimeter

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Safety instructions and installation

INVERTEC 135S, 150S & 170S

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

2-Speed Hammer Drill HP2000 HP2020

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Power supply CP-D 12/2.1

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

SAFETY AND OPERATING MANUAL

MULTI-PURPOSE SAW MODEL NO. OZMPS500A OPERATING INSTRUCTIONS

Power supply CP-E 24/2.5

SAFETY AND OPERATING MANUAL. 750W/13mm IMPACT DRILL JM750ID

Power supply CP-T 48/20.0 Primary switch mode power supply

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Installing the IPS 4240 and the IPS 4255

Installation Instructions RF identification system Read/write head ANT430 ANT431

Earth Fault Indicator EFI-BLZ-50 User Manual

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

Maintenance instructions

6688 OCXO Frequency Reference 6689 Rubidium Frequency Reference. User's Manual

Tube Facing Tool.

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Impact Wrench MODEL TW1000. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

DEIF A/S. Insulation monitor. Type SIM-Q

CEC VIBRATION TRANSMITTER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Instruction Manual MSC710 MSC710-U MSC710-I

INSTRUCTION MANUAL DIGITAL PSC-LOOP TESTER MODEL 4118A KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD.

UMG 96 RM Basic device Power Analyser Operating instructions and technical data

Measuring current transformers of the W, W series

Power supply CP-E 24/0.75

Power supply CP-D 24/1.3

AC/DC Current Oscilloscope Probe Model SL261

Circuit Breaker Finder

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

UMG 96 RM Basic device Power Analyser Operating instructions and technical data Item no

ENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill MHP161 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Flexible Rogowski Coil Integrator Kit with 0-5Vdc and 0-10Vdc User's Manual

ENGLISH (Original instructions) INSTRUCTION MANUAL. Hammer Drill HP1630 HP1631 DOUBLE INSULATION. IMPORTANT: Read Before Using.

Power supply CP-E 24/2.5

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Operating Manual 6 Industrial Bench Grinder ATBG280/

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

Power supply CP-T 24/20.0 Primary switch mode power supply

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

IRM 2500 Rotation plate for oval rings (operating manual)

Power supply CP-E 24/20.0

V6 V10 V35 V45 V218-S V221-S

Impact Wrench. 19 mm (3/4 ) MODEL 6906

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

DM-45 Digital Multimeter

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

CX-A6 Amplifier Installation & User Guide V8.0

INVERTEC V145-S (MANUAL IN ENGLISH) IM /2012 Rev. 7 ENGLISH

FORTUS 360mc/400mc and FDM 360mc/400mc 3D Production System. Site Preparation Guide Rev E

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MDP303 MDP304 DOUBLE INSULATION. IMPORTANT: Read Before Using.

VIP ESI. Electrical Service Industry Voltage and Impedance Indicator. Instruction Manual & Specification

Installation Instructions RF-identification system Read/write head ANT513

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Installation and Operating Instructions for Phase Demodulator Type _.2

...thoroughly tried and tested!

CX-A6 Amplifier Installation & User Guide V9.0

External brake resistor AX2090-BW5x

Measuring current transformers of the W AB(P) series

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

Transcription:

Doc. no. 2.054.018.2 Subject to technical changes. www.janitza.com Mobile universal measurement device MRG 512-PRO PQ Flex Supplementary description to the operation manual UMG 512-PRO Janitza electronics GmbH Vor dem Polstück 6 D-35633 Lahnau Support tel. +49 6441 9642-22 Fax +49 6441 9642-30 E-mail: info@janitza.com Internet: http://www.janitza.com

Contents Safety information 3 Concerning this operation manual 4 Scope of supply - basic device 4 Connecting the measurement case 4 Reading out recordings 5 MRG 512-PRO PQ Flex views 5 Measurement transformer settings 6 Example connection - voltage measurement 7 Example connection - current measurement 7 Schematic diagram: MRG 512-PRO PQ Flex design 8 Technical data 9-2 -

Safety information Please read the operating instructions enclosed diligently, as well as all other publications that must be drawn upon for working with this measurement case and the accessories. Observe all safety instructions and warnings. Failure to comply with the instructions can result in personal injuries and/or damage to the product. The measurement case must only be operated by specialised personnel. Specialised personnel are persons, that based on their respective training and experience, are qualified to recognise risks and prevent potential dangers that can be caused by the operation or maintenance of the measurement case. Check the measurement case, the measurement wires and accessory parts for any signs of damage before use. Check whether there are cracks in the plastic of any parts missing. Pay particular attention to the insulation of the wiring and connectors. Defective parts must be replaced immediately. Do not use if damaged! Comply with all of the locally applicable and national safety regulations. Use personal protective equipment (e.g. approved rubber gloves, face protection and protective clothing) in order to avoid electric shocks and burning injuries. If the measurement case is not operated in accordance with the operation manual, protection is no longer ensured and hazards can be presented by the device! Do not work with the device if the front plate has been removed. Otherwise, you may come into contact with hazardous voltages! It is not permitted to use the device with the front plate removed! c m Do not use the measurement case in wet or moist environments or in the vicinity of explosive gases or vapours. Use the measurement case only with the measurement wires and adapter supplier. Exercise particular caution when connecting and removing the flexible current transformers and the gripping probes for the measured voltage. Ensure that the circuit to be measured is de-energised. Keep your fingers behind the finger protectors on the gripping measurement probes. Voltages and currents that are outside the permissible measurement range can destroy the device. The input voltage shall not be higher than the rated voltage of the measurement device. Disconnect the input signals before cleaning the measurement case. The UMG 512-PRO is not suitable for measuring DC voltages. Measured voltages and measured currents must derive from the same network. Voltages outside the rated range could destroy the measurement case. Incorrect network settings can cause faults in the network. c Attention! Fatal hazard due to electrical energy: High voltage spikes that are dangerous to touch can occur on current transformers that are driven with open-circuit secondary windings! For this reason, never operate current transformers with open-circuit secondary windings! First connect the current transformer lines to the corresponding measurement case inputs! - 3 -

Concerning this operation manual This description and the operating instructions for the device are part of the product. Read this description and the operation manual through prior to using the device. Keep this description and the operation manual throughout the complete service life of the product and have them readily available for reference. Scope of supply - basic device Pass this description and the operation manual on to each subsequent owner or user of the product. In the event of questions that are not covered by this operation manual for the UMG 512- PRO, please contact the support department of Janitza electronics GmbH (Tel. no. +49 6441-9642-22). This device must only be operated and repaired by specialised personnel. Number Designation 1 MRG 512-PRO PQ Flex 1 Supplementary description MRG 512-PRO PQ 1 Operation manual UMG 512-PRO 1 Carry case 1 Mains connection cable 4 Voltage pickoffs with fuses, black (gripping probes) 1 Voltage pickoff with fuse, blue (gripping probe) 1 Voltage measurement set (brown, black, grey, red, blue) 4 Rogowski coil with connection cable and plug (ø 190 mm, L 600 mm) 1 Cross patch cable, CAT 5e 2 Connection cable with plug for residual current measurement, 3 m (Residual current transformer not included in the scope of deliverables) Connecting the measurement case 1. Connect the mains cable to the measurement case (1) and connect to 230 V / 50 Hz. Switch on the measurement case via the on/off switch (2). The "Mains OK" (3) and "Batt. OK" (4) LEDs illuminate. 2. Carry out basic settings on the UMG 512-PRO (5), e.g. - Voltage transformer / current transformer settings - Recording configuration or - RCM measurement (the transformer for RCM measurement is not included in the scope of deliverables). The settings can be implemented via the accompanying GridVis software or directly on the UMG 512-PRO (see the accompanying instructions for the UMG 512-PRO for this). 4. Connect measured voltage with the voltage tap-offs via the voltage inputs (7) or with the measurement lines included in the scope of deliverables. In doing so, observe the applicable safety regulations. 5. Connect current transformer coils (operating current (8) or residual current (9)) with the measurement case via the screw terminals. 6. Connect the current transformer coils to the consumer to be measured. 7. Measurement starts 8. After measurement is complete, switch the device off (2), disconnect from the object being measured and disconnect from the mains! 3. Set up the measurement transformer (6) - see "Measurement transformer configuration" chapter. - 4 -

Reading out recordings If you wish to read out the measured data, connect the measurement case to a PC via the Ethernet connection (10). The read-out is implemented via the GridVis software. MRG 512-PRO PQ Flex views UMG 512-PRO 3. LED Network OK Green: Supply voltage is present Net Ok Batt. Ok I / O 4. LED Batt. OK Green: UPS functioning correctly 6. Measurement transducer 5. Power Analyser UMG 512-PRO 2. On/off switch Switch the device off after the measurement! 9. Residual current transformer inputs I 5, I 6 Residual current transformer inputs I 5 I 6 Voltage inputs L4 L1 L2 L3 N 7. Voltage inputs U L1, U L2, U L3, U L4, U LN Current transformer inputs AUX Ethernet I L1 I L2 I L3 I N 10. Ethernet connection RJ45 8. Current transformer inputs I L1, I L2, I L3, I N 1. Supply voltage - 5 -

Measurement transformer settings Set the following parameters at the integrated measurement transducer: Compensate for the influence of the coil lengths through the potentiometer switching (1). To do so, set the parameters according to the table: (2) Setting Rogowski coil 600 mm Flex-CT-1A-600 mm DIP switch (1) The transformer ratio should be adapted in the UMG 512-PRO measurement device too in accordance with the table. Change the settings by means of the GridVis software or by entries on the device (measurement range: ratio x / 1 A ). Please refer to the UMG 512-PRO operation manual for this. Potentiometer Set the current measurement range with the DIP switch (2) in accordance with the table: Measurement range DIP switch 100 A 8 250 A 7 400 A 6 630 A 5 1000 A 4 1500 A 3 2000 A 2 4000 A 1-6 -

Example connection - voltage measurement Voltage pickoffs with fuse L4 L1 L2 L3 N Locking sleeve with bayonet catch for accommodating a fuse PE N L1 L2 L3 Max. 20mm Example connection - current measurement I5 I6 I1 I2 I3 IN PE N L1 L2 L3 Voltage measurement terms connections Rogowski coil RCM measurement cable Residual current transformer not included in the scope of deliverables - 7 -

Schematic diagram: MRG 512-PRO PQ Flex design Settings, parametrisation and safety information apply in accordance with the m installation and operating instructions enclosed. IDIFF IPE Up to 2 residual current measurements can be selected! 0-30 ma I5 RCM I6 MRG 512-PRO PQ Flex Ethernet 10/100Base-T RJ45 Switch PC PC Versorgungsspannung Auxiliary Supply I1 Strommessung 1-4 Current Input 1-4 Spannungsmessung 1-4 Voltage Input 1-4 I2 I3 I4 L1 L2 L3 LN 230 V 50 Hz PE N L1 L2 L3 Verbraucher Loads c Attention! C Please Fatal hazard due to electrical energy: High voltage spikes that are dangerous to touch can occur on current transformers that are driven with open-circuit secondary windings! For this reason, never operate current transformers with open-circuit secondary windings! First connect the current transformer lines to the corresponding measurement case inputs! ensure the correct setting of the current transformer, check the performance values of the individual phases - these must not possess any negative signs when drawing energy. Also check the power factor for plausibility. Turn the current transformer if necessary! - 8 -

Technical data Power supply Interface Measurement inputs Measurements UPS buffering Dimensions (L x W x H) Weight 230 V, 50 Hz, 50 VA Ethernet See UMG 512-PRO operating instructions See UMG 512-PRO operating instructions Up to 3 h 500 mm x 390 mm x 230 mm 14.2 kg - 9 -