PLL and Self-synchronized Synchonverter: An Overview of Grid-inverter Synchronization Techniques

Similar documents
An Optimized Synchronous Techniques of Single Phase Enhanced Phase Locked Loop (EPLL)

Improved Grid Synchronization Algorithm for DG System using DSRF PLL under Grid disturbances

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

Phase Locked Loop for synchronization of Inverter with Electrical grid: A Survey

Phase-Locked Loops for Grid-Tied Inverters: Comparison and Testing

Control of grid connected inverter system for sinusoidal current injection with improved performance

Microgrid Connection Management based on an Intelligent Connection Agent

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

A Control Topology to Enhance Performance of Weak Grid under Different Power Levels

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

J. Electrical Systems 13-4 (2017): Regular paper

Development of Phase Lock Loop System for Synchronisation of a Hybrid System with the Grid

SCIENCE & TECHNOLOGY

A Resonant Integrator Based PLL and AC Current Controller for Single Phase Grid Connected PWM-VSI

Fault detection in a three-phase system grid connected using SOGI structure to calculate vector components

Photovoltaic System Based Interconnection at Distribution Level With Different Loads

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) INDIRECT CURRENT CONTROLLED SINGLE PHASE SHUNT ACTIVE FILTER

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

Improving the Shunt Active Power Filter Control Methods under Distorted and Unbalanced Grid Voltages

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Power Quality improvement of a three phase four wire system using UPQC

Phase-error correction by single-phase Phase-Locked Loops based on transfer delay

Synchronization Algorithms for Single Phase System

Impact of strength of fault current path on the operation of decoupled double synchronous reference frame phase locked loop

Power Quality Improvement in Wind Energy Conversion System of Grid Interfacing Inverter using Hysteresis Band Current Controller

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

Literature Review for Shunt Active Power Filters

ABSTRACT I. INTRODUCTION

PLL for Grid Synchronization of Single Phase Distributed Generation System

Grid Synchronization by Estimation of Positive Sequence Component in Three Phase Signals

Voltage Support and Reactive Power Control in Micro-grid using DG

Review on Shunt Active Power Filter for Three Phase Four Wire System

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Parallel Operation of Distributed Generators by Virtual Synchronous Generator Control in Microgrids

PHASE-LOCKED LOOP FOR AC SYSTEMS: ANALYSES AND COMPARISONS

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Improved PLL for Power Generation Systems Operating under Real Grid Conditions

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

p. 1 p. 6 p. 22 p. 46 p. 58

Cost Based Dynamic Load Dispatch for an Autonomous Parallel Converter Hybrid AC-DC Microgrid

Current Control Strategy for Parallel Operation of Inverters Based On Micro grids M.Bavithra 1, Belwin J. Brearley 2

International Journal of Modern Engineering and Research Technology

Adaptive Flux-Weakening Controller for IPMSM Drives

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Virtual Instrumentation Applied to Calculation of Electrical Power Quantities in Single-Phase Systems

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

Published in: Proceedings of the 37th Annual Conference of IEEE Industrial Electronics Society, IECON 2011

A NOVEL APPROACH TOWARDS SIX-STEP OPERATION IN OVERMODULATION REGION IN SVPWM VSI

Power Quality Improvement using Shunt Passive Filter

Control of Active and Reactive Power Ripple to Mitigate Unbalanced Grid Voltages

POWER AND ENERGY APPLICATIONS

Flexible Voltage Control Scheme for Distributed Generation Systems under Grid Fault

Resonant Current Control Of Three Phase Grid Connected Photovoltaic Inverters

Protection from Voltage Sags and Swells by Using FACTS Controller

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

A NEW POWER SIGNAL PROCESSOR FOR CONVERTER- INTERFACED DISTRIBUTED GENERATION SYSTEMS

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

IMPORTANCE OF VSC IN HVDC

Modified three phase Unified Power Quality Conditioner with capacitor midpoint topology

Active Power Sharing and Frequency Control of Multiple Distributed Generators in A Microgrid

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

UPQC with Islanding and Grid Connection for Microgrid Applications

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Implementation of a low cost series compensator for voltage sags

ANALYSIS OF GRID SYNCHRONISATION UNDER BALANCED AND UNBALANCED FAULTS USING PLL TECHNIQUES

THE CORRECT line phase-angle is a very important information

Kanuru; Krishna (Dt); A.P, India. DOI: / Page. 1 G. Aruna Jyothi, 2 DR. P. V. R. L.

MODIFYING THE THREE-PHASE SYNCHRONOUS REFERENCE FRAME PHASE-LOCKED LOOP TO REMOVE UNBALANCE AND HARMONIC ERRORS

Islanding Detection and Frequency Circuit Measurement by Power Distribution Relation Depending on the Angle

Improved Active Power Filter Performance for Renewable Power Generation Systems

Control Of Shunt Active Filter Based On Instantaneous Power Theory

This is a refereed journal and all articles are professionally screened and reviewed. Electromechanical Active Filter as a Novel Custom Power device

Power Quality Improvement by Simultaneous Controlling of Active and Reactive Powers in UPQC-S

Integration of Phase-Locked Loop Based Real-time Oscillation Tracking in Grid Synchronized Systems

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Downloaded from

Power Quality Improvement of Non-Linear Load by Using Instantaneous P-Q Theory

Design of Unified Power Quality Conditioner (UPQC) Connected To Three Phase Four Wire System

Comparison of Control Algorithms for Shunt Active Filter for Harmonic Mitigation

Published in: Proceedings of the 39th Annual Conference of IEEE Industrial Electronics Society, IECON 2013

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

A Hierarchical Control Approach for Voltage Unbalance Compensation in A Droop Controlled Micro-Grid

Investigation of D-Statcom Operation in Electric Distribution System

Transcription:

PLL and Self-synchronized Synchonverter: An Overview of Grid-inverter Synchronization Techniques Md Ruhul Amin Department of Electrical Power Engineering Faculty of Electrical and Electronic Engineering Universiti Tun Hussein Onn Malaysia (UTHM) Johor, Malaysia e-mail: ruhulamineee@yahoo.com Shamsul Aizam Zulkifli Department of Electrical Power Engineering Faculty of Electrical and Electronic Engineering Universiti Tun Hussein Onn Malaysia (UTHM) Johor, Malaysia e-mail: aizam@uthm.edu.my Abstract In this paper, a brief summary of synchronization approaches is discussed sequentially from older techniques to latest technology. There are many techniques that have been developed which focusing of synchronization, from basic grid evaluating technique, phase-locked-loop (PLL) and later to synchronous reference-frame phase-locked-loop where is established on basis of phase estimation and determination where it can give fast synchronization time. Recently, due to the advancement of inverter control strategy which is based on the mathematical formulas derivation, a synchronous generator characteristic can be integrated in the inverter controller design. As a result, the inverter will behave like the synchronous generator whereas known it has fast synchronization time and known as synchronverter. At the end of this paper, a comparison table among the existing PLLs with synchronverter in terms of efficiency will be addressed. Keywords - Distributed energy; grid-inverter; synchronization; PLL; amplitude; phase angle; synchronverter. I. INTRODUCTION The locally introduced distributed energy resources (DERs) are connected with conventional grid for sharing loads by means of inverters. For injecting quality power into the grid, there are many power electronic devices and control mechanisms are employed between the conventional grid and DERs. The synchronization between grid and inverter is one of most important issue to deliver high class of power to the grid. The advanced control strategy of synchronization is required for preserving as well as improving the stability of the power system [1-3]. There are many studies have been done on the field of power system control strategies for sending the power from DERs to the conventional ac grid. Most of DERs offer dc output and the dc-storage battery bank is connected with existing alternating current grid network through an efficient inverter [4]. Usually, currentsource inverter (CSI) and in case of standalone operation voltage-source inverter (VSI) are used to supply energy to the grid or utility. Amusingly, the VSI does not need external reference to keep synchronized [5], even it works with other systems with regard to frequency and voltage droops that caused outlining microgrid [6]. During operation of VSI at grid connected mode, it acts like current source instead of voltage source. By maintaining inverter in synchronized condition, the inverter could inject good quality power into the grid at reasonable change in terms of voltage, frequency and phase angle [7]. However, the synchronization unit often needs to provide the value of frequency and the amplitude, with an addition the phase of the fundamental component of the grid voltage for the references for the power controller [8]. In case of synchronous generator (SG) is connected with infinity bus, the power (torque) angle control method is another control method. The phase difference between phase of the grid voltage and of the SG is often called power angle. The control of power angle as well as torque angle control and current vector control for VSI are mostly studied methods. The real power flowing to the grid is controlled by the phase difference, called the power angle or torque angle, between the generated voltage and the grid voltage. The reactive power is controlled by regulating the amplitude of the generated voltage and grid voltage [9]. As shown in figure 1, this conventional synchronization structure consists of synchronization unit to synchronize with the grid in terms of voltage and frequency. Figure 1. Typical grid-inverter connection structure In the operation point of view of synchronous generator, several mathematical models and algorithms behave alike synchronous generator that can be called virtual synchronous machine, commonly the synchronverter has been suggested in [10] that give good synchronization between the inverter and grid. At the same time, the power flow between them can be controlled. It can be run in the mode of gridconnected in addition or stand-alone since it has ability to control voltage and frequency. Moreover, by maintaining proper control topology and algorithm it is capable to share real power and reactive power depends on controlling facilities. In case of three phase applications, there are further demands such as estimations of the fundamental positive or DOI 10.5013/IJSSST.a.17.41.08 8.1 ISSN: 1473-804x online, 1473-8031 print

negative sequences [11], whose characteristic applications are the flexible power control [7] of grid-interfaced converters for distributed power generation from distributed energy resources [12] and active power filters [13] under the distorted and unbalanced circumstances. In addition, fast and precise synchronization are forthright requirement having wide range of reactive and real power controlling options [11]. In this paper, various synchronizing techniques of converter have been discussed in the synchronization means with grid and converter and the details on the synchronverter also been discussed. II. CONNECTIONS AND SYNCHRONIZATION TECHNIQUES The most important and basic conditions for such applications are to possess inverter synchronized with the grid before and after the inverter being connected to the grid. So that, 1) an inverter can be connected to the grid, and 2) the inverter can feed the right amount of power to the grid even when the grid voltage changes its frequency, phase, and amplitude [14]. Moreover, the concept of plug and play distributed microsources is the key to microgrids. To accomplish this goal, the ideas of active-power/frequency and reactive-power/voltage droop controls will be used. Its allow microsources to share power and maintain stability without the need for fast communications [14]. However, it has been a norm to adopt a synchronization unit, e.g. PLL to make sure that the inverter is synchronized with the grid. This practically adds an outer-loop controller (the synchronization unit) to the inverter controller [15] such as shown in Figure 1. III. PLL AND SYNCHRONIZATION The most extensively acknowledged for synchronization procedure in time domain is shown in figure 2. It shows, the difference between input phase angle V in and the output signal ð are measured by the Phase Detection (PD) and passed through the Loop Filter (LF). The output signal of LF triggers the Voltage-Controlled Oscillator (VCO) to generate the output signal, which would monitor the input signal from the inverter voltage. hand, this scheme cannot be applied to single phase systems in an up-front manner [17]. Conversely, it affords a beneficial structure for single-phase PLLs as long as the 90 degree shifted orthogonal component of the single phase input signal is created [18]. The instantaneous real and imaginary power theory (PQ-PLL) has the alike arrangement to the conventional SF-PLL [18]. Figure 3 shows the PQ- PLL block diagram. Figure 3. Block diagram of PQ-PLL This PQ-PLL can be easily understood from as a instantaneous power theory concept. The fundamental positive-sequence component is obtained as a by-product. Sometimes, PLL fails in tracking the system voltage during initialization under some opposing conditions, and oscillations is caused by the existence of subharmonics pulls the stable point of operation synchronized to the subharmonic frequency. In order to settle these problems, a robust PQ-PLL is presented to maintain synchronization in presence of subharmonics, harmonics, and negative sequence unbalances [19]. Moreover, Double Synchronous Frame PLL (DSF-PLL) is constructed based on both transformation on the positive and negative sequence components of the utility voltage into the double synchronous frame, which can entirely disregard the detection errors of the conventional SF-PLL [20-21]. On the other hand, Sinusoidal Signal Integrator PLL (SSI-PLL) tracks the utility voltage by extracting the fundamental positive sequence to the SF-PLL [22-23]. Consequently, it operates under voltage distortions as well as imbalances condition. The block diagram of SSI -PLL is shown in figure 4, whereas the constant K regulates the bandwih and the speed-response of the SSI-PLL. Figure 2. Typical synchronization structure As known, Synchronous-Frame PLL (SF-PLL) in threephase systems is effectively synchronized grid-inverter connection due to keep reference voltage locked to utility voltage vector phase angle. In the event of utility voltage is distorted which having high-order harmonics, PLL bandwih reduction is not satisfactory in the presence of the unbalanced utility voltage [16]. It should be noted that, Synchronous Reference Frame PLL (SRF-PLL) does not provided individual values of the amplitude, phase and frequency rather than average information. On the other Figure 4. SSI-PLL block diagram A sequence detector chooses the sign of Vα+ and Vβ+. When the voltage sequence at the PCC is recognized in advance, the sequence detector can be abolished. The main advantages of SSI-PLL are invulnerability to the voltage DOI 10.5013/IJSSST.a.17.41.08 8.2 ISSN: 1473-804x online, 1473-8031 print

distortion and unbalance conditions. In addition, it can be extended into the single-phase system applications with a few modifications successfully. Similar, Double second order generalized integrator (DSOGI-PLL) extracts the fundamental positive sequence to the SF-PLL whereas it operates a double second order generalized integrator to implement the quadrature-signals generator [24]. Therefore, the precise sequence component extraction here requires 90 0 phase shift for Vα+ and Vβ+. There are two solutions for this purpose, the transport delay buffer method and the all pass filter method. Proper mixing Band Pass Filter (BPF) and Low Pass Filter (LPF) remove the harmonics and 90 phase shift by recognizing the angular frequency ω. Figure 5 shows the DSOGI-PLL block diagram. On the other hand, Enhanced PLL (EPLL) is a frequency-adaptive nonlinear synchronization approach [25]. The main progress over the conventional PLL lies in the PD mechanism is it permits more flexibility and provides more facts such as amplitude and phase angle. Figure 5. DSOGI-PLL block diagram EPLL also provides higher degree of resistance and insensitivity to noise, harmonics and unbalance of the input signal. Whereas, Three Phase Multi-PLL (3MPLL) adaptively tracks and estimates the magnitude, phase angle, and frequency of the input signal [26]. The operation principle of Quadrature PLL (QPLL) is stated in [27] where this method is based on estimating in-phase and quadraturephase amplitudes of the fundamental component of the input signal. In advantage, it is applicable for both in distributed generation and communication system applications. In case of wide-range of synchronization, the Predictive PLL (PPLL) comprises of a predictor, oscillator, and phase-shifter and data acquisition blocks [28]. It has phase locking mechanism similar to the conventional PLL while PPLL locks to the phase of input signals, however, it works the systematic expressions for computing the frequency, amplitude and phase difference in a predicted manner [29]. In addition, the synchronize information can be determined within two cycles of the input signal period in the poor condition for example perturbations in frequency, amplitude and phase angle. There are some other PLL have been developed on linear and non-linearity basis as well as adaptability in Adaptive Linear Combiner (ALC) [30], Multi-rate-PLL (MR-PLL) [31], Adaptive PLL (APLL) [32] and more basic zero-crossing detector (ZCD) method for stable and sinusoidal input signal [32]. IV. SYNCHRONVERTER A synchronverter is an inverter that mimics a conventional synchronous generator. Synchronverters are grid-friendly inverters that mimic synchronous generators (SG) [10]. Mathematically, a synchronverter is a model, which behaves as in same as synchronous machine to deliver a voltage supply. Since, PLLs are characteristically nonlinear, difficult and time-consuming to tune the PLL parameters to reach satisfactory performance while controlling the inverter in power system. It affects not only control performance and degrade system stability but also a complex synchronization unit is often computationally intensive. The controlling principle of a power controller is combined capability of controlling the voltage and frequency parameter. So it is able to achieve real power control, reactive power control, frequency regulation, and voltage regulation. Consider a round rotor machine has stator inductances are constant. The mathematical equations for the generator can be written by assuming there is no damper windings in the rotor, that there is one pair of poles per phase without having any magnetic-saturation effects in the iron core as well as no eddy currents. The phase voltage v of terminal can be obtained below. d di v RSi RSi LS e (1) dif e Mfif sin Mf cos (2) 1 (T m T e D p ) J (3) Te Mfif isin (4) e Mfifsin (5) Q Mfif isin (6) Where Tm, Te, e, θ, and Q are the mechanical torque applied to the rotor, the electromagnetic torque, the threephase generated voltage, the rotor angle, and the reactive power. Figure 6 shows that Electronic part of synchronverter with controller. Assume that figure 7 is the per-phase model of a synchronous generator is connected to an infinite bus. Grid current and voltage Frequency droop Equation (3) Equation (4) Equation (5) & (6) Voltage droop Figure 6. Synchronverter with control e DOI 10.5013/IJSSST.a.17.41.08 8.3 ISSN: 1473-804x online, 1473-8031 print

ACKNOWLEDGMENT Authors gratefully acknowledge the support of Universiti Tun Hussein Onn Malaysia (UTHM) for UTHM Scholarship funding and RAGS (R037) to undertake this research activity. REFERENCES Figure 7. SG-infinite bus connection model [11]. The generated real power P and reactive power Q are expressed. VE g P sin( g ) (7) XS Vg Q [Ecos( g) V g] (8) X S The real power is controlled by a frequency droop control loop. This loop regulates the (imaginary) speed of the synchronous machine and creates the phase angle for the control signal e. The reactive power is controlled by a voltage droop control loop using the voltage droop. This loop regulates the field excitation, which is proportional to the amplitude of the voltage generated. Hence, the frequency control, voltage control, real power control, and reactive power control are all integrated in one compact controller with only four parameters. It is appealed in [11] that regulation of reactive power Q flowing out of the synchronverter can be comprehend to frequency response found in few cycle in experimental synchronverter [10]. This operation is tested in grid frequency lower and higher then nominal 50Hz successfully. The voltage droop modes of proposed synchronverter comprises slight overshoots with smooth transition [11]. Some experimental results from the novel synchronverter well found with a PLL is presented in [32]. V. CONCLUSION An ample analysis of phase locked loop methods and synchronization techniques have been executed to discover a comprehensive viewpoint on their dissimilar and diverse structures and applications. On the design simplicity, frequency adaptive, timing, distortion insensitivity, unbalanced insensitivity and single-phase points of view, it is proved that synchronverter is most prospective solution for grid-inverter synchronization having extensive range of controlling strategy in distributed energy resources as well as all grid-connected applications. In order to simplify the collection of the given requirement, Table I provides brief comparisons as well as guidelines for the proper choice of PLL and synchronization schemes for specific applications. [1] Lee, C.T., Chu, C.C. and Cheng, P.T., A new droop control method for the autonomous operation of distributed energy resource interface converters, IEEE Transactions on Power Electronics 28(4), 2013, pp.1980-1993. [2] Zhengbo, M., Linchuan, L. and Tuo, D, Application of a combined system to enhance power quality in an island microgrid. IEEE Conference on Power Engineering and Automation (PEAM), 2011, Vol. 3, 2011, pp.326-330, doi: 10.1109/PEAM.2011.6135104 [3] Roy, R.B. and Amin, M.R., Analysis of Proposed Controlling Topology of the HVDC link between Bangladesh and India. 9th International Forum on Strategic Technology (IFOST), 2014, pp. 390-395, doi: 10.1109/IFOST.2014.6991147 [4] Blaabjerg, F., Teodorescu, R., Liserre, M. and Timbus, A.V, Overview of control and grid synchronization for distributed power generation systems. IEEE Transactions on Industrial Electronics, 53(5), 2006, pp.1398-1409. [5] Vásquez, J.C., Guerrero, J.M., Gregorio, E., Rodríguez, P., Teodorescu, R. and Blaabjerg, F., June. Adaptive droop control applied to distributed generation inverters connected to the grid. IEEE International Symposium on Industrial Electronics, 2008. ISIE 2008, pp.2420-2425. doi: 10.1109/ISIE.2008.4677215 [6] Rocabert, J., Luna, A., Blaabjerg, F. and Rodríguez, P., Control of power converters in AC microgrids. IEEE Transactions on Power Electronics, 27(11), 2012 pp.4734-4749. [7] Sultani, J.F., Modelling, Design and Implementation of DQ Control in Single-Phase Grid-Connected Inverters for Photovoltaic Systems used in Domestic Dwellings. 2013. [8] Shinnaka, S., A novel fast-tracking D-estimation method for singlephase signals, IEEE Transactions on Power Electronics, 26(4), 2011, pp.1081-1088. [9] Amin, M.R. and Roy, R.B., Design of microcontroller based Thyristor Controlled three-phase static volt-ampere reactive compensator. IEEE International Conference on Informatics, Electronics & Vision (ICIEV)2014, pp. 1-6. doi: 10.1109/ICIEV.2014.6850694 [10] Zhong, Q.C. and Weiss, G., Synchronverters: Inverters that mimic synchronous generators. IEEE Transactions on Industrial Electronics, 58(4), 2011, pp.1259-1267. [11] Zhong, Q.C., Nguyen, P.L., Ma, Z. and Sheng, W., Self-synchronized Synchronverters: inverters without a dedicated synchronization unit. IEEE Transactions on Power Electronics, 29(2), 2014, pp. 617-630. [12] Rodriguez, P., Timbus, A.V., Teodorescu, R., Liserre, M. and Blaabjerg, F., Flexible active power control of distributed power generation systems during grid faults. IEEE Transactions on Industrial Electronics, 54(5), 2007, pp.2583-2592. [13] Montero, M.I.M., Cadaval, E.R. and González, F.B., Comparison of control strategies for shunt active power filters in three-phase fourwire systems. IEEE Transactions on Power Electronics, 22(1), 2007, pp. 229-236. [14] Thacker, T., Boroyevich, D., Burgos, R. and Wang, F., Phase-locked loop noise reduction via phase detector implementation for singlephase systems. IEEE Transactions on Industrial Electronics, 58(6), 2011, pp. 2482-2490. [15] Svensson, J., Synchronisation methods for grid-connected voltage source converters. IEE Proceedings of In Generation, Transmission and Distribution, 148(3), 2001, pp. 229-235. doi: 10.1049/ipgtd:20010101 DOI 10.5013/IJSSST.a.17.41.08 8.4 ISSN: 1473-804x online, 1473-8031 print

[16] Chung, S.K., A phase tracking system for three phase utility interface inverters. IEEE Transactions on Power Electronics, 15(3), 2000, pp. 431-438. [17] Silva, S.A.O.D., Novochadlo, R. and Modesto, R.A., Single-phase PLL structure using modified pq theory for utility connected systems, IEEE Conference on Power Electronics Specialists, PESC 2008, pp. 4706-4711. doi: 10.1109/PESC.2008.4592712 [18] Silva, S.M., Lopes, B.M., Braz Filho, J.C., Campana, R.P. and Bosventura, W.C., October. Performance evaluation of PLL algorithms for single-phase grid-connected systems. IEEE Conference Record of the 2004 on Industry Applications Conference, 2004. 39th IAS Annual Meeting, 4, 2004, pp. 2259-2263. doi: 10.1109/IAS.2004.1348790 [19] Rolim, L.G.B., Costa, D.R.D. and Aredes, M., Analysis and software implementation of a robust synchronizing PLL circuit based on the pq theory. IEEE Transactions on Industrial Electronics, 53(6), 2006, pp.1919-1926. doi: 10.1109/ISIE.2003.1267261 [20] Rodriguez, P., Pou, J., Bergas, J., Candela, J.I., Burgos, R.P. and Boroyevich, D., Decoupled double synchronous reference frame PLL for power converters control, IEEE Transactions on Power Electronics 22(2), 2007 pp. 584-592. [21] Rodriguez, P., Luna, A., Teodorescu, R., Iov, F. and Blaabjerg, F., Fault ride-through capability implementation in wind turbine converters using a decoupled double synchronous reference frame PLL. European Conference on Power Electronics and Applications, 2007, pp. 1-10. doi:10.1109/epe.2007.4417783 [22] Yuan, X., Merk, W., Stemmler, H. and Allmeling, J., Stationaryframe generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions. IEEE Transactions on Industry Applications, 38(2), 2002, pp. 523-532. [23] Bojoi, R.I., Griva, G., Bostan, V., Guerriero, M., Farina, F. and Profumo, F., Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame. IEEE Transactions on Power Electronics, 20(6), 2005, pp. 1402-1412. [24] Ciobotaru, M., Teodorescu, R. and Blaabjerg, F., A new single-phase PLL structure based on second order generalized integrator, 37th IEEE Conference Power Electronics Specialists, PESC'06, 2006 pp.1-6. doi:10.1109/pesc.2006.1711988 [25] Karimi-Ghartemani, M. and Iravani, M.R., A method for synchronization of power electronic converters in polluted and variable-frequency environments, IEEE Transactions on Power Systems, 19(3), 2005, pp.1263-1270. [26] Karimi-Ghartemani, Masoud. "A novel three-phase magnitude-phaselocked loop system, IEEE Transactions on Circuits and Systems I: Regular Papers 53(8), 2006, pp.1792-1802. [27] Karimi-Ghartemani, M., Karimi, H. and Iravani, M.R, A magnitude/phase-locked loop system based on estimation of frequency and in-phase/quadrature-phase amplitudes. IEEE Transactions on Industrial Electronics, 51(2), 2004, pp.511-517. [28] Timorabadi, H.S. and Dawson, F.P., A wide-range synchronization system for ac power systems. IEEE International Symposium on Industrial Electronics, 2006, 3, pp. 1667-1672. [29] Han, B. and Bae, B., Novel phase-locked loop using adaptive linear combiner. IEEE transactions on power delivery, 21(1), 2006, pp.513-514. [30] Pavljasevic, S. and Dawson, F., Synchronization to disturbed utilitynetwork signals using a multirate phase-locked loop. IEEE Transactions on Industrial Electronics, 53(5), 2006, pp. 1410-1417. [31] Jovcic, D., Phase locked loop system for FACTS. IEEE Transactions on Power Systems, 18(3), 2003, pp. 1116-1124. [32] Choi, J.W., Kim, Y.K. and Kim, Digital PLL control for single-phase photovoltaic system. IEE Proceedings-Electric Power Applications, 153(1), 2006, pp. 40-46. doi:10.1049/ip-epa:20045225 TABLE I. BRIEF COMPARISONS OF SYNCHRONIZATION SCHEMES FOR SPECIFIC APPLICATIONS Type of schemes Design Simplicity Frequency adaptive & range Distortion insensitivity Unbalance insensitivity Timing Aptness to Single-phase SF-PLL Good Average Average Poor Average Average PQ-PLL Average Average Average Poor Average - DSF-PLL Average Average Good Good Good - SSI-PLL Average Average Good Good Good Good DSOGI-PLL Average Average Good Good Good Good EPLL Average Average Good Good Good Good PPLL Average Good Good Good Good Good MR-PLL Average Average Good Theoretically Feasible Good Good ZCD Good Poor Poor Poor Poor Good Synchronverter Very Simple Very Good Very Good Good Very Good Good DOI 10.5013/IJSSST.a.17.41.08 8.5 ISSN: 1473-804x online, 1473-8031 print