TECHNICAL DATA SHEET STANDARD STEEL FRAMES SPECIFICATIONS MESKER STANDARD STEEL FRAMES

Similar documents
Table of Contents F Series Frames

MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee

Seamed Edge Doors 1000 Series

Through and through, our metal frames stand strong.

Solid Core Wood Door / Steel Frame Packages

Masonry Frames Interior/Exterior* Drywall Frames Interior**

THIS PAGE INTENTIONALLY LEFT BLANK

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

C-Series & S-Series Classic Frame with Transom (Single or Pair)

DCI Hollow Metal Technical Data

SPLIT FRAME INSTALLATION INSTRUCTIONS

DOOR COMPONENTS, INC Technical Data

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Product Guide. An Introduction to Hollow Metal Terminology and CURRIES Product. ASSA ABLOY, the global leader in door opening solutions

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

LABEL & RATING OPTIONS

SECTION HOLLOW METAL DOORS AND FRAMES

Versatrim Side-Snap Frame

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

Subject: Specification Compliance

ARCHITECTURAL STICK SYSTEMS

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

SECTION BULLET- RESISTANT DOORS

IMPORTANT NOTICE WARRANTY WILL BE HONORED ONLY IF THE JAMBS HAVE BEEN INSTALLED IN ACCORDANCE WITH THESE INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ENGINEERING DETAILS for STANDARD SERIES F-16 and DW-16 UNI-FRAME for 1¾ Doors

Steel Door Frame Installation in Steel Stud Construction

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Through and through, our metal frames stand strong.

Parveneer Positive Pressure Fire Rated Frames Double rabbet with T stop for 20 minutes

REVIEW ALL INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING INSTALLATION

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

SECTION HOLLOW METAL DOORS AND FRAMES

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

INSTALLATION INSTRUCTIONS FOR CECO DOOR FLOOD RESISTANT DOOR AND FRAME ASSEMBLIES

Heavy Wall Applied Stop Tube Frame and Door Installation

BioPrism Solid Surface

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

Karpen. Steel. Custom Doors & Frames. The Custom Quick-Ship Professionals. Division

How To Measure Your Finished Opening

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

1530(F) Mortise Exit Devices Installation Instructions

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

Versatrac R-System Stock Extrusions, Clips and Accessories

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232

DOOR SAVERS AVAILABLE IN STEEL, STAINLESS STEEL (32D), BRIGHT BRASS (3), BRONZE (10) AND OIL RUBBED BRONZE (10B)

Versatrac R-System Stock Extrusions, Clips and Accessories

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

Pivots / Padlocks / Hasps

Oxford Stalls Installation Instructions

Installation Instructions

Chapter 18. Interior Doors

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

3 BRACKET TO GUIDE ATTACHMENT. RIGHT END Figure 1. EXTENDED BRACKET (for doors taller than 8-8 ) SERIES 650. RIGHT END COTTER PIN Figure 6

Senior Swing. Caution

HMMA GUIDE SPECIFICATIONS FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM SEVENTH EDITION

MINIMALIST DOOR FRAMES

Stainless Steel Continuous Hinges

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

INSTALLATION INSTRUCTIONS

YSD 400 Sliding Door System Installation Manual

SLIDE 06 Solutions Document/Installation Manual

STC 46 3-Sided Paired Frame (Double Rabbet Only)

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

FIB-R-MAX STANDARD SINGLE DOOR

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Chapter 9. Windows and Exterior Doors

table of contents Sliding Door Accessories Page Latches & Snuggers Stay Rollers Brackets & Stops

FB-01C SR-02C FB-01C832 FLA 12 SR-02C FB-01C-D SR-02C SR-02C08-32 FLA SR-02C

Installation Instructions For 1-3/4 Acoustical Door Units. H Seals And Super "H" Door Bottoms

Chapter 9. Windows and Exterior Doors

INSTALLATION INSTRUCTIONS SERIES 487 CENTER GLAZED WITH 1-1/2" TRIM OFFICE PARTITIONS

Knock Down Patio Door Assembly Instructions Regular & Impact

HMMA 861 GUIDE SPECIFICATIONS FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES -00 AMERICAN NATIONAL STANDARD ANSI/NAAMM METAL DOORS & FRAMES

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Pre-Hanging Information

DOORS TECH-DATA MANUAL INDEX PAGE

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

TIP FOR GETTING STARTED

Aluminum Continuous Geared Hinges

SECTION STILELITE TM STEEL DOORS AND FRAMING. glass moldings and stops as shown in the approved submittal drawings.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

WARRAntY & HInGE types

MINIMALIST DOOR FRAMES PRODUCT BROCHURE ARCHITECTURAL METALS

Installation Instructions. Installation Type

FOR PROFESSIONAL GARAGE DOOR INSTALLERS

Transcription:

DS-201-1 STANDARD STEEL FRAMES SPECIFICATIONS STANDARD STEEL FRAMES 1. Frames shall be manufactured by Mesker Door Incorporated and designated as F-416 (16 GA) or F-414 (14 GA) for 1 3/4 doors, F-412 for Bullet Resistant Frames and F-816 (16 GA) for 1 3/8 doors. 2. Frames shall be fabricated from cold rolled or A60 galvannealed steel. 3. Frames shall be furnished knocked down. Mitered corners shall have a strong four tab interlocking system to maintain tight fineline miters. 4. Frames for 1 3/4 doors shall be prepared for a 4 1/ x 4 1/ standard or heavy weight template hinges and ANSI 115.1 universal strike. 5. Frames for 1 3/8 doors shall be prepared for 3 1/ x 3 1/ standard weight template hinges and ANSI 115.3 cylindrical strike. 6. Frames are standard with 7 gauge hinge reinforcements. 7. Frames shall be adequately reinforced for all hardware. 8. Strike and hinge reinforcements shall be protected by plaster guards. 9. Frames shall be supplied with 1 sill anchor. 10. Frames shall be furnished with rubber mutes, three per strike jamb. 11. Frames shall receive 1 coat of baked-on rust inhibitive gray primer. 12. For installation instructions see ANSI A250.11-2001.

DS-201-2 11/3 1/8 1/ DIA 9/3 HOLE IN FRAME PHEUMATIC CHAMBER MUTES TO INSTALL IN FIELD INSERT BLUNT END OF 3/3 DIAMETER WIRE OR TOOL INTO THE HOLE IN CENTER OF THE MUTE. MOISTEN CONE PORTIONS AND INSERT INTO 9/3 HOLE IN STOP OF FRAME, PUSH SLOWLY WITH A CIRCULAR MOTION TO ELONGATE CONICAL PORTION SUFFICIENTLY TO SET MUTE IN PLACE. 3 3/4 JAMB DEPTH 4 3/4 5 3/4 6 3/4 7 3/4 8 3/4 1 15/16 1 9/16 1 9/16 VARIES 1 15/16 5/8 TYP 1 15/16 1 9/16 3 1/ 1/ 1/ 3 3/4 4 7/8 5 3/4 6 3/4 7 3/4 THROAT OPENING FINISHED FINISHED OPENING OPENING WIDTH HEIGHT SINGLE DOUBLE 6-8 7-0 7-8 -0 2-0 2-4 2-6 2-8 3-0 3-6 3-8 4-0 4-0 4-8 5-0 5-4 6-0 7-0 7-4 8-0 1/ FRAME DIMENSIONS JAMB THROAT DEPTH OPENING 3 3 3/4 4 3/4 5 3/4 7 3/4 8 3/4 7/16 ON 5 3/4 DEPTH 2 3/16 2 3/4 3 3/4 4 7/8 6 3/4 7 3/4 13/3 13/3 STANDARD FRAME PROFILES NET DOOR HEIGHT 7 1/4 EQUAL EQUAL NET DOOR WIDTH C L HINGE STRIKE CL 40 5/16 12 1/4

DS-201-3 HINGE PREPARATION WILL TAKE 4 1/ HIGH TEMPLATE HINGES ONLY STANDARD OR HEAVY WEIGHT, NON- TEMPLATE HINGES CANNOT BE USED #20 GUAGE PLASTER GUARD PROJECTION WELDED TO HINGE 3/16 HINGE TO FRAME. HINGE PREPARATION WILL TAKE 3 1/ X 3 1/ TEMPLATE HINGES OR NON-TEMPLATE (S.D.I.) HINGES #20 GUAGE PLASTER GUARD PROJECTION WELDED TO HINGE #10 GUAGE HINGE TO FRAME 1/ 23/64 PROJECTIONS TO DRILL OUT FOR HEAVY WEIGHT HINGES 4 PLACES. 1 25/64 1 15/64 4 1/ 1/ 5/3 5/8 DRILLED AND TAPPED FOR #12-24 SCREWS 3/8 5/8 5/16 BACKSET 3 1/ 1 25/64 23/64 DRILLED AND TAPPED FOR #10-24 SCREWS 25/64 21/64 1/4 BACKSET 1 5/8 21/3 5/3 1 3/8 STANDARD 4 1/ HINGE MORTISE FOR 1 3/4 FRAMES STANDARD 3 1/ HINGE MORTISE FOR 1 3/8 FRAMES #20 GUAGE PLASTER GUARD PROJECTION WELDED TO STRIKE #14 GUAGE STRIKE TO FRAME #20 GUAGE PLASTER GUARD PROJECTION WELDED TO STRIKE #14 GUAGE STRIKE TO FRAME DRILLED AND TAPPED FOR #12-24 SCREWS PIERCED AND TAPPED FOR #8-32 SCREWS 3 3/8 4 1/8 4 7/8 STRIKE MORTISE CONFORMS TO ANSI A115.1 1 1/ 2 1/8 2 3/4 3/3 STRIKE MORTISE CONFORMS TO ANSI A115.3 3/3 5/8 5/8 5/16 BACKSET 1 1/4 9/16 9/16 1/4 BACKSET U STRIKE MORTISE C STRIKE MORTISE

DS-201-4 GENERAL INFORMATION TABS MUTES 3 PER STRIKE JAMB HINGE STRIKE STRIKE PREPARATIONS Frames are prepared for 4 7/8 high universal strike (ANSI 115.1) specify U and 2 3/4 high cylindrical strike (ANSI 115.3) specify C. HINGE PREPARATIONS Frames for 1 3/4 doors are prepared for 4 1/ x 4 1/ standard or heavy weight template hinges. 1 1/ pair on doors up to 7 - in height and 2 pair on 7-10 and 8-0. Frames for 1 3/8 doors are prepared for 3 1/ x 3 1/ standard weight template hinges. 1 pair on 6-8 doors and 1 1/ pair on 7-0 and 7 doors. U/L labeled frames have 1 1/ pair on all sizes. SILL ANCHOR 16 GAUGE ANCHORS Anchors must be specified to correspond with wall condition. Details are shown on the following data sheets: Wire Anchor - DS 246 Masonry Tee Anchor - DS 242 Wood and Steel Stud Anchor - DS 243 U/L Labeled Masonry Anchor - DS 241 Existing Wall Anchor - DS 245 PLASTER GUARD SILL ANCHORS Each jamb is supplied with 1-16 gauge sill anchor. HINGE MUTES Each frame is furnished with rubber mutes. Three per strike jamb. 1 9/16 OR 1 15/16 PLASTER GUARD STRIKE TAB IS OFFSET TO OBTAIN SMOOTH BEND ALONG TOP OF FRAME HEAD. 1 9/16 OR 1 15/16 SECTION THRU TAB

DS-201-5 F-SERIES ASSEMBLY INSTRUCTION 1. Slide header over jamb corner tabs, insert into slots. 2. Bend tabs on jamb rabbets out per illustration. (NOTE: Bending tabs in will increase door opening dimension.) 3. Bend corner tabs in per illustration. (BEND IN) CORNER TABS TAB IS OFFSET TO OBTAIN SMOOTH BEND ALONG TOP OF FRAME HEAD SECTION THRU TAB JAMB TABS (BEND OUT) VARIES HEAD TABS JAMB

DS-202-1 DJ SERIES STANDARD STEEL DRYWALL FRAMES SPECIFICATIONS STANDARD STEEL DRYWALL FRAMES 1. Frames shall be manufactured by Mesker Door Incorporated and designated as FDJ416 (16 GA) for 1 3/4 doors, and as FDJ816 (16GA) for 1 3/8 doors. 2. Frames shall be fabricated from cold rolled or A60 galvannealed steel as called for on plans. 3. Frames shall be knocked down construction. Frames shall be furnished with two (2) adjustable jamb lock mechanisms. Two (2) dimpled holes at the base of each jamb to stabilize the frame at installation. 4. Frames for 1 3/4 doors shall be prepared for 4 1/ x 4 1/ standard or heavy weight template hinges and ANSI 115.1 universal strike. 5. Frames for 1 3/8 doors shall be prepared for 3 1/ x 3 1/ standard weight template hinges and ANSI 115.3 cylindrical strike. 6. Frames shall be adequately reinforced for all hardware. 7. Frames shall be furnished with rubber mutes, three per strike jamb. 8. Frames shall receive 1 coat of baked-on rust inhibitive gray primer. 9. For installation instructions see DS-202-5.

DS-202-2 DIMPLED FOR A #10 DRYWALL SCREW DFA ANCHOR FRAME HANDING DOUBLE INSIDE RHR ACTIVE OUTSIDE RH ACTIVE INSIDE LHR ACTIVE OUTSIDE LH ACTIVE 3/4 3/4 INSIDE SINGLE INSIDE STANDARD OPTIONAL RHR OUTSIDE RH LHR OUTSIDE LH STANDARD FRAME PROFILES 4 1/ - 7 1/4 1/8 INCREMENTS JAMB DEPTH 1 9/16 VARIES 1 15/16 5/8 1 9/16 1 15/16 1 VARIES 5/8 1/4 1/ THROAT OPENING STANDARD SIZES FINISHED OPENING FINISHED OPENING WIDTH HEIGHT SINGLE DOUBLE 6-8 7-0 7-2 -0 2-4 2-6 2-8 3-0 3-4 3-6 3-8 4-0 4-0 4-8 5-0 5-4 6-0 6-8 7-0 1/4 1/ FRAME DIMENSIONS JAMB THROAT DEPTH OPENING 4 1/ 5 5/8 5 7/8 3 1/ 4 5/8 4 7/8 NET DOOR HEIGHT 1/ 7 1/4 EQUAL EQUAL 12 1/4 3 5/8-4 3/8 1/8 INCREMENTS 1/ NET DOOR WIDTH C L HINGE STRIKE C L 40 5/16 FINISH FLOOR

DS-202-3 HINGE PREPARATION WILL TAKE 4 1/ HIGH TEMPLATE HINGES ONLY. NON-TEMPLATE HINGES CANNOT BE USED. STANDARD 4 1/ HINGE MORTISE FOR 1 3/4 FRAMES 3/16 HINGE TO FRAME STANDARD 3 1/ HINGE MORTISE FOR 1 3/8 FRAMES HINGE PREPARATION WILL TAKE 3 1/ X 3 1/ TEMPLATE HINGES OR NON-TEMPLATE (S.D.I.) HINGES #10 GAUGE HINGE TO FRAME. 1/ PROJECTIONS TO DRILL OUT FOR HEAVY WEIGHT HINGES 4 PLACES. 23/64 1 25/64 1 15/64 4 1/ 1/ 5/3 5/8 3/8 5/8 1 5/8 DRILLED & TAPPED FOR #12-24 SCREWS 5/16 BACKSET 3 1/ 1 25/64 23/64 21/3 DRILLED & TAPPED FOR #10-24 SCREWS 25/64 21/64 1/4 BACKSET 1 3/8 5/3 U STRIKE MORTISE C STRIKE MORTISE #20 GAUGE PLASTER GUARD PROJECTION WELDED TO STRIKE #14 GAUGE STRIKE TO FRAME #20 GAUGE PLASTER GUARD PROJECTION WELDED TO STRIKE #14 GAUGE STRIKE TO FRAME 4 7/8 4 1/8 3 3/8 3/3 5/8 5/8 5/16 BACKSET 1 1/4 DRILLED AND TAPPED FOR #12-24 SCREWS STRIKE MORTISE CONFORMS TO ANSI A115.1 1 1/ 2 1/8 2 3/4 3/3 9/16 9/16 DRILLED & TAPPED FOR #8-32 SCREWS STRIKE MORTISE CONFORMS TO ANSI A115.3 1/4 BACKSET

DS-202-4 HINGE TABS MUTES 3 PER STRIKE JAMB SEE DETAIL B STRIKE GENERAL INFORMATION STRIKE PREPARATION - Frames are prepared for 4 7/8 high universal strike (ANSI 115.1) specify U and 2 3/4 high cylindrical strike (ANSI 115.3) specify C. HINGE PREPARATIONS - Frames for 1 3/4 doors are prepared for 4 1/ x 4 1/ standard weight template hinges 1 1/ pair on doors up to 7 in height. 2 pair on 7 10 and 8 0. Frames for 1 3/8 doors are prepared for 3 1/ x 3 1/ standard weight template hinges. 1 pair on 6 8 doors and 1 1/ pair on 7 0 and 7 doors. SILL ANCHOR 16 GUAGE MUTES TO INSTALL IN FIELD: INSERT BLUNT END OF 3/3 DIAMETER WIRE OR TOOL INTO THE HOLE IN CENTER OF THE MUTE. MOISTEN CONE PORTIONS AND INSERT INTO 9/3 HOLE IN STOP OF FRAME. PUSH SLOWLY WITH A CIRCULAR MOTION TO ELONGATE CONICAL PORTION SUFFICIENTLY TO SET MUTE IN PLACE. ANCHORS - The Mesker DJ Series Drywall Frame is stabilized with two (2) adjustable jamb locks, located near the top of each jamb. There are two (2) sill anchors available. The stocked frame has the faces dimpled for a #10 drywall screw. The DFA anchor can be provided as an extra cost option. MUTES - Each frame is furnished with rubber mutes. Three per strike jamb. ROUGH OPENING DIMENSIONS - Add to door opening dimensions: 1 7/8 to width and 1 1/ to height, i.e. for a 3068 door frame, the rough opening is 37 7/8 x 81 1/. ADJUSTABLE JAMB LOCK (LOCATED AT THE TOP OF EACH JAMB) DETAIL B ADJUSTABLE JAMB LOCK

DS-202-5 SERIES FDJ416 DRYWALL FRAME INSTALLATION HEADER NOMINAL DOOR HEIGHT + 1 1/ STRIKE JAMB NOMINAL DOOR WIDTH +1 7/8 ADD TO DOOR OPENING DIMENSIONS: 1 7/8 TO WIDTH AND 1 1/ TO HEIGHT. FOR A 3068 DOOR FRAME, THE ROUGH OPENING IS 37 7/8 X 81 1/. INSTALL HEADER INTO POSITION APPROX. 1 FROM TOP AND IN THE CENTER OF THE ROUGH OPENING. INSTALL STRIKE JAMB BY SLIDING OVER WALL AT TOP AND ENGAGING CORNER REINFORCING INTO HEADER. PIVOT JAMB INTO PLACE. HINGE JAMB ANCHOR ADJUSTING SCREW (TYPICAL BOTH JAMBS) LEVEL OR SQUARE REPEAT STEP #3 WITH HINGE JAMB. PULL HEADER DOWN TIGHTLY ONTO JAMBS. LOCK HEADER AND JAMB TOGETHER BY BENDING OVER EXPOSED TABS. TURN ADJUSTING SCREWS IN BOTH JAMBS COUNTERCLOCKWISE UNTIL ANCHOR IS RESTING AGAINST THE WALL. IF FEASIBLE, HANG DOOR NOW AND ADJUST FRAME ON WALL TO ALLOW PROPER DOOR/FRAME CLEARANCES OR PLUMB FRAME WITH CARPENTER SQUARE AND/OR LEVEL. (ADJUST HEADER LEVELNESS BY SHIMMING UNDER JAMBS.) ALT. DIMPLED FOR A #10 DRYWALL SCREW 3/4 3/4 DFA ANCHOR CHECK DOOR OPENING DIMENSION AT BASE OF FRAME (SAME DIMENSION AS BETWEEN JAMBS AT HEADER.) SECURE JAMBS WITH DRYWALL SCREW (NOT FURNISHED) THROUGH PUNCHED HOLE AT BASE OF FRAME. BE SURE TO ATTACH SCREWS ON EACH SIDE OF JAMBS (4 PLACES.) CHECK DOOR OPENING DIMENSION AT BASE OF FRAME (SAME DIMENSION AS BETWEEN JAMBS AT HEADER.) SECURE JAMBS WITH DRYWALL SCREWS (NOT FURNISHED) THROUGH SILL ANCHOR. (NOTE: SPECIFY ON YOUR ORDER IF THIS METHOD OF ATTACHMENT IS REQUIRED.)