Transmitters BROCHURE

Similar documents
914DNS. Pressure and Density Transmitter. Features. 1 Datasheet 914DNS Pressure and density transmitter.

Transmitters DATASHEET

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

A New Generation of Pressure Transmitters

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

A New Generation of Pressure Transmitters

Proline Promass F 300, 500

Technologies, Solutions, and Applications. Guided Wave Radar for Level

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Compact Orifice Flow Meter

RUNYI GROUP AJ FLOW TOTALIZER. Features

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

Electro-Magnetic Flowmeters COPA-XE

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

TMU. Coriolis Mass Flow Meter. for liquids and gas

DRS390 High stability, flange mounting

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Field Devices and Wiring

Field IT 2600T Series Pressure Transmitters

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Process Control Drawings

IFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series

FOSTEN AUTOMATION SÉRIE F500-RD

TS16 - Pre-Instructional Survey

Coriolis Massflowmeter

FICHA TÉCNICA DE PRODUTO

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

SITRANS L Level instruments

Rosemount 333 HART Tri-Loop

ST 3000 Fieldbus Transmitter Series 100 Models

Modulating control valve

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Coriolis Massflowmeter

Coriolis Mass Flow Meters. Advanced flow measurement made easy.

Vortex Flow Measuring System prowirl 77

What does the Process Automation understand under Diagnosis?

ph / ORP Measurement mypro CPM 431

E-Chart Image Release History

Various Technics of Liquids and Solids Level Measurements (Part 4)

Thermal Mass Flowmeter DATASHEET

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

prosonic T FMU230, FMU231

Accutech DP20. Wireless differential pressure field unit

Technologies, Solutions, and Applications. Magnetic Level Indication and Bridle Measurements

SensyCal FCU200, SensyCal FCU400 Universal Measuring Computer. Multifunctional Precise Compact. Data logger function and billing date recording

Intelligent Communicator DCR3000

PAD - Heavy Duty Differential Pressure Trasmitter

Mass Flowmeter CoriolisMaster FCM2000

SensyCal FCU200, SensyCal FCU400 Universal Measuring Computer

Ambient Conditions. Operating Conditions. Pressure

LST100 Ultrasonic level transmitter for upstream oil and gas

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Accurate Low Flow Rate Measurement Using a Specially Designed Differential Pressure Type Flowmeter

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

FCX. Series AII & AIIe Electronic Transmitters. Barton

VELTRON II Microprocessor Based Pressure & Flow Smart

Level Measurement Continuous level measurement Radar transmitters

PlantPAx Distributed Control System (DCS) Demonstrator - Pressure, Flow, Level, Temperature (3531-V0)

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

LST400 Ultrasonic level / open channel flow transmitter

Level Measurement With REFLEX RADAR

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Level gauges Series LT Level indicator, switch and transmitter for liquids

Supercal 531 Multi function Integrator that lives up to Your highest expectations

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

mass flowmeter for compressed air

Spirit IT Flow-X High accuracy flow computers

Coriolis Mass Flow Meter Model TM

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

General Specifications

Mass Flowmeter CoriolisMaster FCM2000

DP2500 DP0100 DP0250 Differential Pressure Transmitter

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Condumax W CLS15 and CLS15D

Full Metal Variable Area Flowmeter and Counter Model BGF

STD96. Universal Pressure Transmitter with local LCD Display

Advanced instrumentation solutions crafted with highest precision

Series Smart Pressure Transmitter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

SITRANS LR 300: High Performance Radar for Level Measurement

Microprocessor Gas and Steam Flow Computer Energy Flow Computer (Consumption and Enthalpy for Steam) Series: DigiFlow Type: 515

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Process Leak Detection Diagnostic with Intelligent Differential Pressure Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Magnetostrictive Level Transmitter

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

AT200 External Mount Magnetostrictive Level Transmitter

REFLEX RADAR INDICATOR

Pharma Temperature Sensor G3/8"

Transcription:

Transmitters BROCHURE JUNHO 2013

Pressure transmitter 2600T with multi-sensor technology The versatile champion Multi-functional: a single transmitter up to three measured values Flexible: PROFIBUS PA, FOUNDATION Fieldbus, HART, Modbus Convenient: configurable via local operating keypad Modular: exchangeable electronics with self-reconfiguration Global: national and international approval certificates ABB Instrumentation

Clever use of fieldbus technology: Multi-sensor transmitters of the 2600T series The use of fieldbus technology considerably increases the range of information from your field instruments. In addition to the measured value, the status and alarm messages provide valuable information about plant status and reliability of the measured values. The transmitters of the 2600T series with their multi-sensor technology support the availability of this information in a unique way. Process variable DP P T Process Measured value DP P T Process Status Alarm Status Alarm Status Alarm Choice of functions - Selectable characteristics: - linear/square rooting, - freely programmable characteristic - e. g. for volume measurements in a spherical container - Min/max indicator - Event counter for when range, sensor limits and temperature are exceeded - Simulation of any output current - Alarm condition (selectable): alarm signal can be configured as constant current 4 ma or 20 ma - Open channel flow measurement (p 3/2 ) A single transmitter provides up to three measured values - With an accuracy of 0.075 %, optionally 0.04 % - Each with an alarm and status report Using one device for three measurements saves mounting, installation and investment cost. - Less shut-offs - Fewer mechanical connections Supports fieldbus protocols - PROFIBUS PA - FOUNDATION Fieldbus - HART - Modbus Comfortable configuration through local operating keypad and integral digital display - Easy adaptation to the operating conditions at the measuring point - Less planning and commissioning time and cost Local digital and analog measured value display - To increase the local convenience and information flow Exchangeable electronics with self reconfiguration - Quick and reliable trouble-shooting (should problems ever arise the instrument has an impressive MTBF of 200 years!) Various national and international approval certificates ensure universal usage - CSA, FM, ATEX

Intelligent technology so easy to handle Multi-sensor transmitters 267JS / 269JS The unique combination of several sensor systems in a single device permits simultaneous measurement of differential pressure, absolute pressure and, via an external sensor, process temperature. Additionally, the sensor temperature is measured and recorded for service and diagnosis purposes. The sensor temperature and the absolute pressure are also used for eliminating environmental effects on the sensor. Maintenance and diagnosis information such as Value above/below range Measuring sensor overload Sensor out of temperature range is available. EEPROM - Sensor-specific data - Configuration data Linearisation Temperature correction A/D converter Differential pressure Static pressure Sensor temperature Adjustment of - ZERO - SPAN Write protection RAM - Measuring range - Configuration data LC display Transfer function Controller (FF) Self-monitoring Diagnosis El. damping D/A converter DP P T Protocols - PROFIBUS PA - FOUNDATIONFieldbus - HART Output Differential pressure Static pressure Functional diagram of the measuring section/electronic section The digital interface between the sensor and the electronics does not only provide for signal processing without additional errors. It also facilitates the replacement of the electronic section and makes the transmitter easily serviceable. All parameters and configuration data relevant for the measuring point are saved in the non-volatile memory of the sensor. After replacement of the electronics, automatic data transfer is carried out. The previous transmitter functionality is thus restored, without requiring further user actions. The new sensor technology provides for extremely short response times and, thus, allows a quick reaction on process changes. Despite serial signal processing, this feature is achieved by using several A/D converters. Sensor and electronic section Take advantage of our experience Our experience and know-how in the field of pressure transmitter development, construction and production were a good basis for our 2600T. This transmitter has a very good long-time stability and will make a good job over years without requiring any maintenance. Firm as a rock Considerably reduced environmental and process effects due to multi-sensor technology. The result: reliable and safe measurement. Early detected, immediately eliminated Permanent self-monitoring functions allow for an early diagnosis. A write protect switch prevents unauthorized access to the device. So easy to handle Keys and switches on the device and a digital display allow for easy parameter setting and configuration on site. There is no need to open the device in the field. This prevents the ingress of moisture or aggressive substances into the device and ensures reliable functionality over a long time. The measured value is indicated in both an analog and digital manner on the LCD. Which of the available measured values differential pressure, pressure or temperature is indicated can be defined by configuration. Good visibility even under bad light conditions is ensured by the background illumination function of the display.

Mass flow measurement Multi-variable transmitter 267CS / 269CS ONE transmitter THREE measured values: Differential pressure adjustable measuring ranges, 0.5 mbar 20 bar Absolute pressure adjustable measuring ranges, 6 bar 410 bar Temperature measuring range 50 C +650 C Optional output signals: 4 20 ma/hart PROFIBUS PA FOUNDATION Fieldbus Modbus Selectable accuracy: 0.075 % 0.04 % Mass flow measurement Connecting an external temperature sensor allows for measuring the process temperature in addition to the pressure variables. As a result, the transmitter is capable of measuring gases, vapors and liquids using the differential pressure method. The operating density of the fluid is calculated as a function of pressure and temperature, and from this results the mass flow. Mass and standard volume flow in accordance with AGA 3 or DIN EN ISO 5167. qm = K. ρ1 = ρn. P1. Tn. Zn C. ε. d 2. ρ1 dp 1 β 4 Pn. T1. Z1 The pressure and temperature dependent values for vapors, liquids and gases are calculated using tables saved in the device. Highest accuracy is achieved through: Dynamic flow correction with continuous calculation of Reynold s number and flow coefficient Correction of material-dependent thermal size changes Linearization of the primaries Flow correction is also possible without temperature measurement with fixed temperature. Mass flow measurement even more efficient, due to the variety of supported primaries: Orifice, corner, D- and D/2 taps Orifice, flange taps Small bore orifices (flange/corner taps) ISA-1932 nozzle Long radius nozzle Classic Venturi meter Venturi nozzle Pitot tube V-cone Wedge element Integral orifice Pure density correction (without considering the primary)

Communication using the Device Management Software The Device Management Software DSV401 (SMART VISION) allows for data communication with the field instruments. It supports the PROFIBUS, FOUNDATION Fieldbus, HART and Modbus communication standards. DSV401 is used for parameter display, configuration, diagnosis, support of service and maintenance tasks, data management and documentation. Calibration/Adjustment by mouse-click Adjustment of the lower range value and span with and without application of pressure. Measured value display Digital display of the process pressure as a percentage and in physical units as colored bargraph as trend data display in four sections, with adjustable time ranges Verification and plausibility checking of the measuring point are supported in an optimal manner through the possibility to simulate all input values. The main features at a glance Device diagnostics Information about the process data reliability Online data monitoring Detection of process malfunctions Process value alarms Access to detailed information about the process state Device data read-out to ensure that all requirements regarding corrosion protection, certificates etc. are met

Contactos/Contacts: Comercial/Commercial: Fernando Mena Costa e-mail: fcosta@bhb,pt Tel: (+351) 21 843 64 00 Fax: (+351) 21 843 64 09 Assistência/Service: Patricia Costa e-mail: ppcosta@bhb.pt Tel: (+351) 21 843 64 00 Note: ABB the owner of this document, reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. Copyright 2011 ABB. All rights reserved