Cool Power Technologies

Similar documents
Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

Cool Power Technologies

(DOSA) VDC, 5.5 A.

Cool Power Technologies

Cool Power Technologies

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

QME48T40 DC-DC Series Data Sheet VDC Input; A Output

Asia-Pacific Europe, Middle East North America Bel Power Solutions, Inc. BCD.

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS. Input Voltage Continuous 0 80 VDC. Operating Ambient Temperature C

S24SP series 60W Single Output DC/DC Converter

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

(typ.) (Range) Parameter Model Min. Typ. Max. Unit

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

ISOLATED DC/DC CONVERTERS 48 Vdc Input 2.5 Vdc /20 A Output, 1/8 Brick Converter

QME48T20120 DC-DC Converter Data Sheet VDC Input; A Output Data Sheet

S24SE/S24DE series 15W Single/Dual Output DC/DC Converter

Input Voltage Continuous 0 80 VDC Operating Ambient Temperature C Storage Temperature C

Features. Applications. QD48T DC-DC Converter Data Sheet VDC Input; 1.8 and A Output

PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS. Input Voltage Continuous 0 80 VDC. Operating Ambient Temperature C

TBD. Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W FEATURES OPTIONS APPLICATIONS

QME48T40 DC-DC Series Data Sheet VDC Input; A Output

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

North America Asia-Pacific Europe, Middle East

Input Voltage Continuous 0 80 VDC Operating Ambient Temperature C Storage Temperature C

Q54SJ W DC/DC Power Modules FEATURES. Q54SJ12058, 700W Quarter Brick DC/DC Power Modules: 40~60Vin, 12.2V/ 57.4A out OPTIONS APPLICATIONS

YNV12T05 DC-DC Converter Data Sheet VDC Input; VDC 5 A

500 WATT MXW SERIES DC/DC CONVERTERS

360 WATT MTW SERIES DC/DC CONVERTERS

Networking Computers and Peripherals Telecommunications

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Parameter Symbol Min Typ Max Unit Operating voltage Range Vin Vdc Input current at 36V. Iin - - A Input current at 55V

SQE48T20120 DC-DC CONVERTER

Model Number Active Low 12 Vdc 18 Vdc - 36 Vdc 20 A 240 W 94.5% 0RQB-T0R120 0RQB-T0R12L. Max. Output Power

Conditions: TA = 25ºC, Airflow = 300 LFM (1.5 m/s), Vin = 48 VDC, unless otherwise specified. PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS

AA SERIES (1 x 1 Package) Up to 30 Watt DC-DC Converter

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

AA SERIES (1 x 1 Package) Up to 10 Watt DC-DC Converter

V36SE12005 FEATURES. Delphi Series V36SE, 1/16 th. Brick DC/DC Power Modules: 18~75Vin, up to 60W OPTIONS APPLICATIONS

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

QM48T/S14120 DC-DC Converter Data Sheet VDC Input; A Output

PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS Absolute Maximum Ratings

This unit is designed to be highly efficient and low cost. Features include remote on/off, over current protection and overvoltage protection.

Delphi Series S36SA, 25W Family DC/DC Power Modules: 18Vin to 60Vin, 3.3V/8A out

This unit is designed to be highly efficient and low cost. Features include remote on/off, over current protection and overvoltage protection.

1000 WATT FXW SERIES DC/DC CONVERTERS

PARAMETER CONDITIONS / DESCRIPTION MIN TYP MAX UNITS. Input Voltage Continuous 0 80 VDC. Operating Ambient Temperature C

150 WATT QSW DC/DC CONVERTERS

Intermediate Bus Architectures Data communications/processing LAN/WAN Servers, Workstations

ISOLATED DC/DC CONVERTERS 48 Vdc Input, 12 Vdc/8.35 A Output

Delphi Series V48SR, 1/16 th Brick 66W

Encapsulated Type. Page I-III. Page 1-15 Open-Frame Type. S36SE3R305 Datasheet

Delphi Series S48SP, 35W 1x1 Brick DC/DC Power Modules: 48V in, 5V/7A out

Delphi Series E48SP Eighth Brick Family DC/DC Power Modules: 48V in, 12V/20A out

Delphi Series H48SC3R325, 85W Half Brick Family DC/DC Power Modules: 48V in, 3.3V/25A out

AS SERIES (2.00 x 1.6 Package) Up to 20 Watt DC-DC Converter

Delphi S36SE, 25W 1x1 Brick Series DC/DC Power Modules: 36~75V in, 12V/2A out

H80SV12017 * * FEATURES. Delphi Series H80SV, half Brick Family DC/DC Power Modules: 16.8~137.5 Vin, 54/48/24/15/12Vout,200W APPLICATIONS

Delphi E36SR Series DC/DC Power Modules: 18~60 in, 12V/4A out, 48W

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

V36SE12004 FEATURES. Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W OPTIONS APPLICATIONS

MIW3000 Series EMI. 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

Asia-Pacific Europe, Middle East North America Bel Power Solutions, Inc. BCD.

S24SP12004 series 40W Single Output DC/DC Converter

S24SP05012 series 60W Single Output DC/DC Converter

S24SP24003 series 60W Single Output DC/DC Converter

Delphi Series E48SR, 66W Eighth Brick Family DC/DC Power Modules: 48V in, 15V/4A out

ISOLATED DC-DC CONVERTER CEB75 SERIES APPLICATION NOTE

The 0RQB-C5U54x is an isolated DC-DC converter that operates from a nominal 24 VDC, 48 VDC source.

Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 12V/10A out

200 WATT TH SERIES DC/DC CONVERTERS

di/dt Nex TM-v Series: YNV12T05

SRPE-50E1A0 Non-Isolated DC-DC Converter

OVP 2:1. Wide Range. Protection

MAX. OUTPUT POWER 24/48/72/96/110 VDC 5 VDC 6 A 30 W 82% 0RQB-30Y05L. 0 R QB - 30 Y 05 L y. Output Power. Input Range

SMT20C SERIES. Single Output TÜV. SMT20C Series 20 A DC-DC Converter C Class Non-Isolated

ICH 500-Watt Series Wide Input Isolated Half Brick DC-DC

PM24S/DR24S series 60W Single Output DC/DC Converter

EQD075 Series (Eighth-Brick)DC-DC Converter Power Modules 18-60Vdc Input; 3.3 to 5.0Vdc Output; 75W

Delphi Series H48SA, 150W Half Brick Family DC/DC Power Modules: 36~75V in, 48V/3.2A out

0RCY-F0S10x Isolated DC-DC Convert

Delphi Series Q48SK, Quarter Brick Family DC/DC Power Modules: 36~75V in, 12V/18A out, 216W

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

QUARTER-BRICK SERIES Single Output Performance Products

SIL20C SERIES. Single Output. SIL20C Series 20 A DC-DC Converter C Class Non-Isolated

Delphi Series V48SC, 1/16th Brick 90W DC/DC Power Modules: 48V in, 12V, 7.5A out

` FEATURES. Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power Modules: 48V in, 1.0V/50A out OPTIONS APPLICATIONS

Delphi Series H48SA, 450W Half Brick Family

Distributing Tomorrow s Technologies For Today s Designs Toll-Free:

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, up to 50W

Delphi Series E48SP3R340, 1/8 th Brick 132W DC/DC Power Modules: 48V in, 3.3V, 40A out

Delphi Series V36SE, 1/16 th Brick DC/DC Power Modules: 18~75Vin, 3.3Vo, 50W

Delphi Series T48SR, 1/32 Brick Family DC/DC Power Modules: 36~75V in, 5V/5A out, 25W FEATURES OPTIONS APPLICATIONS

Transcription:

- 1 - Cool Power Technologies Eighth-Brick Isolated DC/DC Converter Features Ultra-wide input voltage range: 40 150Vin Output: 24V @ 1.2A ROHS Directive 2011/65/EU Compliant No minimum load required Low height - 0.465 (11.8mm) max. Baseplate option - 0.500 (12.7mm) tall 2250VDC Input-Output Isolation Fixed-frequency operation Industry standard 1/8th brick footprint Remote sense Full protection (OTP, OCP, OVP, UVLO auto-restart) Remote ON/OFF - positive or negative enable logic options Output voltage trim (industry-standard trim equations) Weight: 0.79 oz [22.4 g] On-board input differential LC-filter Meets UL94, V-0 flammability rating Compliant to REACH (EC) No 1907/2006 Designed to meet UL/CSA60950-1, TUV per IEC/EN60950-1, 2 nd edition Designed to meet Class B conducted emissions per FCC and EN55022 when used with external filter (see EMC Compliance section below.) Description The Cool Power Technologies DC-DC converter is an open frame eighth-brick DC-DC converter that conforms to industry standard specifications. The converter operates over an input voltage range of 40 to 150 VDC, and provides a tightly regulated 24V output voltage with an output current rating of 1.2 Amps. The output is fully isolated from the input and the converter meets Basic Insulation requirements. The standard feature set includes remote On/Off (positive or negative enable), input undervoltage lockout, output overvoltage protection, overcurrent and short circuit protections, output voltage trim, remote sense and overtemperature shutdown with hysteresis.

- 2 - SECTION TABLE OF CONTENTS PAGE FEATURES & DESCRIPTION 1 APPLICATION DIAGRAM 2 ELECTRICAL SPECIFICATIONS 3 CHARACTERISTIC PERFORMANCE CURVES 6 CHARACTERISTIC WAVEFORMS 7 APPLICATION NOTES 8 RIPPLE MEASUREMENTS TEST SET-UP 8 OUTPUT VOLTAGE TRIM EQUATIONS 9 THERMAL DERATING 10 EMC COMPLIANCE 12 MECHANICAL OUTLINE & PCB FOOTPRINT 13 ORDERING INFORMATION 14 APPLICATION DIAGRAM

- 3 - ELECTRICAL SPECIFICATIONS 40 150Vin, 24V/1.2Aout Conditions: T A = 25 ºC, Airflow = 300 LFM, Vin = 96 VDC, Cin = 33 µf, unless otherwise specified. Input Characteristics Parameter Conditions Min Typ Max Unit Operating Input Voltage Range 40 96 150 VDC Input Under-Voltage Lock-out Turn-on Threshold Turn-off Threshold 43.5 37.3 44.2 38.5 44.9 39.9 Input Voltage Transient 100ms 160 VDC Maximum Input Current V IN = 40VDC; I out = 1.2A 0.88 A Input Standby Current Converter Disabled 2 5 ma Input No-Load Current Converter Enabled 35 50 ma Short Circuit Input Current RMS 30 ma Input Reflected Ripple Current 5Hz to 50MHz See Fig 1 for setup VDC 15 22 ma PK-PK Input Voltage Ripple Rejection 120Hz 50 db Inrush Current All - - 0.01 A 2 /s Output Characteristics Parameter Conditions Min Typ Max Unit Output Voltage Set point Sense pins connected to output pins 23.64 24 24.36 VDC Output Current 0 1.2 A Output Current Limit Inception 1.3 1.6 2.5 A Peak Short-Circuit Current 10mΩ Short 4 A RMS Short-Circuit Current 10mΩ Short 0.4 A RMS External Load Capacitance 220 uf Output Ripple and Noise Output Regulation Line: Load: Overall Output Regulation: 20MHz Bandwidth 1 uf Ceramic + 10uF Tantalum See Fig 2 for setup Over line, load & temp 23.4 100 150 mv PK-PK ±10 ±10 ±20 ±20 24.6 mv mv V

- 4 - ELECTRICAL SPECIFICATIONS (continued) 40 150Vin, 24V/1.2Aout Conditions: T A = 25 ºC, Airflow = 300 LFM, Vin = 96 VDC, Cin = 33 µf, unless otherwise specified. Absolute Maximum Ratings Parameter Conditions Min Typ Max Unit Input Voltage Continuous Operation 0 150 VDC Operating Ambient Temperature W/ Derating -40 +85 C Operating Temperature Open Frame -40 +110 C T ref, see Thermal Derating section Baseplate Option -40 +123 C Storage Temperature -55 +125 C Feature Characteristics Parameter Conditions Min Typ Max Unit Switching Frequency 325 khz Output Voltage Trim Range 1-10 +10 % Remote Sense Compensation 1 +10 % Output Over-voltage Protection Non-latching 115 125 140 % Over-temperature Protection Peak Backdrive Output Current during startup into prebiased output Avg. PCB temp, non-latching Sinking current from external voltage source equal to VOUT 0.6V and connected to the output via 1Ω resistor. COUT=220µF, Aluminum 135 C Backdrive Output Current in OFF state Converter disabled 0 5 ma Enable to Output Turn-ON Time V OUT = 0.9*V OUT_NOM 30 ms Output Enable ON/OFF Negative Enable Converter ON Converter OFF Positive Enable Converter ON Converter OFF Enable Pin Current Source/Sink Output Voltage Overshoot @ Startup Auto-Restart Period All voltages are WRT Vin. Converter has internal pull-up of approx. 5V (all protection features) -0.5 2.4 2.4-0.5 N/A 0.25 0.8 20 20 0.8 1 ma VDC VDC VDC VDC ma 0 2 %Vo 100 ms

- 5 - ELECTRICAL SPECIFICATIONS (continued) 40 150Vin, 24V/1.2Aout Conditions: Ta = 25 ºC, Airflow = 300 LFM, Vin = 96 VDC, Cin=33 µf, unless otherwise specified. Efficiency Parameter Conditions Min Typ Max Unit Full Load 50% Load Dynamic Response Vin = 96 V 86 88 % Vin = 112 V 85 87 % Vin = 96 V 83 85 % Vin = 112 V 81 83 % Parameter Conditions Min Typ Max Unit Load Change 50%-75% or 25% to 50% of Iout Max, di/dt = 0.05 A/µs Settling Time to 1% of Vout Load Change 50%-100% of Iout Max, di/dt = 1 A/µs Settling Time to 1% of Vout Isolation Specifications Co = 1 µf ceramic + 10 µf tantalum Co = 1 µf ceramic + 10 µf tantalum 200 300 mv 50 µs 400 600 mv 50 µs Isolation Capacitance 1000 pf Isolation Resistance 10 MΩ Isolation Voltage Input to Output - Open frame Input to Output - Baseplate 2250 V DC 2250 V DC Input to baseplate 1500 V DC Reliability Per Telcordia SR-332, Issue 2: Method I, Case 3 (I O =80% of I O _max, T A =40 C, airflow = 200 lfm, 90% confidence) Output to baseplate 1000 V DC MTFB 3,750,845 Hours FITs (failures in 10 9 hours) 267 /10 9 Hours Notes: 1) Combination of remote sense + trim up not to exceed 10% of V onom.

- 6-2) CHARACTERISTIC CURVES: Efficiency 95% 90% 85% 80% 75% Vin=45V 70% Vin=90V 65% Vin=112V Vin=140V 60% 0.12 0.24 0.36 0.48 0.6 0.72 0.84 0.96 1.08 1.2 Output Current (A) Figure 1. Efficiency vs Output Current, 300lfm airflow, 25 C ambient. Power Dissipation (W) 8 7 6 5 4 3 2 1 Vin=45V Vin=90V Vin=112V Vin=140V 0 0.12 0.24 0.36 0.48 0.6 0.72 0.84 0.96 1.08 1.2 Output Current (A) Figure 2. Power Dissipation vs. Load Current, 300lfm airflow, 25 C ambient. 1.20 1.20 Output Current (A) 1.00 0.80 0.60 0.40 0.20 N/C ~40LFM (0.2m/s) Output Current (A) 1.00 0.80 0.60 0.40 0.20 N/C ~40LFM (0.2m/s) 0.00 25 40 55 70 85 Ambient Temperature ( C) Figure 3. Output Current Derating vs Ambient Temperature & Airflow (converter mounted vertically with air flowing from pin 3 to pin 1, Vin = 96 V.) 0.00 25 40 55 70 85 Ambient Temperature ( C) Figure 4. Output Current Derating vs Ambient Temperature & Airflow (converter mounted vertically with air flowing from pin 3 to pin 1, Vin = 48 V.) 1.20 Output Current (A) 1.00 0.80 0.60 0.40 0.20 N/C ~40LFM (0.2m/s) 100 LFM (0.5 m/s) 200 LFM (1.0 m/s) 300 LFM (1.5 m/s) 0.00 25 40 55 70 85 Ambient Temperature ( C) Figure 5. Output Current Derating vs Ambient Temperature & Airflow (converter mounted vertically with air flowing from pin 3 to pin 1, Vin = 112 V.) Figure 6. Thermal Image of (1.2A output, 85C Ambient, 100lfm airflow, Vin = 96V, airflow from pin 3 to pin 1, Tmax = 110 C)

- 7 - CHARACTERISTIC WAVEFORMS: Figure 7. Output Voltage Ripple (50mV/div), time scale 1uS/div. Vin=Vin_nom, full resistive. Figure 8. Input Reflected Ripple Current (10mA/div) time scale - 2uS/div. Vin=Vin_nom, full resistive. Figure 9. Startup Waveform via Line Voltage, time scale 10mS/div. Vin=Vin_nom, full resistive load (negative enable.) Ch1=5V/div, Ch2=20V/div Figure 10. Startup Waveform via Enable Pin, time scale 10mS/div. Vin=Vin_nom, full resistive load + 1000uF (negative enable.) Ch1,Ch2=5V/div Figure 11. Load Transient Response (100mV/div), di/dt=0.05a/us, 50% - 75% - 50% of full load, time scale: 200uS/div. Figure 12. Load Transient Response (500mV/div), di/dt=0.5a/us, 50% - 100% of full load, time scale: 100uS/div

- 8 - Application Notes Input Voltage Reflected Ripple Measurement INPUT REFLECTED RIPPLE TEST SETUP: TO OSCILLOSCOPE Current Probe DC Source C source : 220 uf ESR < 0.1 OHM @ 20 ºC, 100 khz L source : 10 uh 100 uf ESR < 0.7 OHM Vin(+) Vin(-) Note: Measure input reflected-ripple current with a simulated source inductance (Ltest) of 10 uh. Capacitor CS offsets possible source impedance. Output Voltage Ripple Measurement OUTPUT RIPPLE TEST SETUP: Figure 13. Input Reflected-ripple Current Test Setup. Vout(+) COPPER STRIP 1.0 uf 10 uf SCOPE RESISTIVE LOAD Vout(-) Note: Use a 1µF X7R ceramic capacitor and a 10µF tantalum capacitor. Scope measurement should be made using a BNC socket. Position the load 3 in. [76mm] from module. Figure 14. Peak-to-Peak Output Noise Measurement Test Setup.

- 9 - Application Notes (cont) Output Voltage Trim Output voltage adjustment is accomplished by connecting an external resistor between the Trim Pin and either the +Sense or Sense pins. TRIM UP EQUATION: ( ) 5.1 Vo_nom 100 + % R trim_up 1.225 % 510 10.2 kω % Where Rtrim_up is the resistance value in k-ohms and % is the percent change in the output voltage. E.g. to R 5.1 24 ( 100 + 10) 510 trim_up 10.2 kω 1.225 10 10 trim the output up 10%, or Rtrim_up = 1037.9kOhm. +Vin +Vout +Sense Enable Trim R trim_up R load -Sense -Vin -Vout Figure 15. Trim UP circuit configuration TRIM-DOWN EQUATION: 510 R trim_down % 10.2 kω Where Rtrim_down is the resistance value in k ohms and % is the percent change in the output voltage. +Vin +Vout +Sense Enable Trim R load R trim_down -Sense -Vin -Vout Figure 16. Trim DOWN circuit configuration

- 10 - Application Notes (cont) Thermal Derating It is preferable that the DC-DC module have an unobstructed flow of air across it for best thermal performance. Components taller than ~ 2mm in front of the module can deflect airflow and possibly create hotspots. Significant cooling is achieved through conductive flow from the modules I/O pins to the host PCB. Sufficiently large traces connecting the dc-dc converter to the source and load will help ensure thermal derating performance will meet or exceed the derating curves published in this datasheet. If the module is expected to be operated near the load limits defined in the derating curves, insystem verification of module derating performance should be performed to ensure long-term system reliability. Peak temperatures are to be measured using infrared thermography or by gluing a fine gauge (AWG #40) thermocouple at the T ref location(s) shown below. T ref_2 should be monitored for input voltages below 60 Vin, T ref_1 for input voltages > 60 Volts. Temperatures at the specified location(s) are not to exceed 123ºC in order to maintain converter reliability. Input Undervoltage Lockout The converter is disabled until the input voltage has exceeded the UVLO turn-on threshold. Once the input voltage exceeds this level (see Input Under-Voltage Lock-out in Electrical Specifications table) the module will commence soft-start. Hysteresis of 2-3 volts minimizes the likelihood of pulling the input voltage below the turn-off threshold during startup which could create an undesirable on/off cycling condition. The converter will continue to operate until the input voltage subsequently falls below the UVLO turn-off threshold. Enable Pin Function The module has a remote enable function that allows it to be turned on or off remotely. The Enable pin is referenced to the negative input pin (-Vin) of the converter. Modules can be ordered with either negative or positive enable. The negative enable option the module will not turn on unless the enable pin is connected to Vin. The positive enable option allows the converter to turn on as soon as voltage sufficient to exceed the UVLO of the converter has been applied to the input terminals. In this case the module is turned off by connecting the Enable pin to Vin. On/off thresholds are located in the Electrical Specifications table.

- 11 - Application Notes (cont) Output Overvoltage Protection The module has an independent feedback loop that will disable the output of the converter if a voltage greater than about 125% of the nominal set point is detected. When this threshold is reached, the converter will shut down and remain off for the amount of time specified by the Auto-Restart Period. The converter will attempt a restart once this period of time has elapsed. Output Overtemperature Protection To provide protection under certain fault conditions, the unit is equipped with a thermal shutdown circuit. The unit will shutdown if the average PCB temperature exceeds approx. 135ºC, but the thermal shutdown is not intended as a guarantee that the unit will survive temperatures beyond its rating. The module will automatically restart once it has cooled below the shutdown temperature minus hysteresis (typically 20 deg C.) SMT Version Layout Considerations (if applicable) Copper traces with sufficient cross-section must be provided for all output & input pins. SMT pads tied to internal power/ground planes must have multiple vias around each SMT pad to couple expected current loads from module pins into internal traces/planes. One 0.024 (0.6mm) diameter via for each 4A of expected source or load current must be provided as close to the termination as possible, preferably in the direction of current flow from SMT pad to load. Vias must be at least 0.024 (0.6 mm) away from the SMT pad to prevent solder from flowing into the vias. SMT pads on the host card are to be 0.080 (2mm) diameter. Solder paste screen opening should be 0.075 diameter and the screen should be 0.006 (0.15 mm) thick (other thicknesses are possible; 0.006 provides a good compromise between solder volume and coplanarity compensation.) Paralleling Converters Modules may be paralleled but it is recommended that the total power draw not exceed the output power rating of a single module. External sharing controllers are recommended for reliability and to ensure equal distribution of the load to the converters.

- 12 - Application Notes (cont) EMC Compliance To meet Class B compliance for EN55022 (CISPR 22) or FCC part 15 sub part j, the following input filter is required: Figure 17. EMI Filter L1 = 1.32 mh Common Mode Inductor (Pulse P0420NL) C1, C2, C3 = 2.2uF ceramic C4 = 100uF electrolytic C5, C6 = 8.2nF (@2kV if output is ref. to gnd.) 100 90 80 70 60 dbuv 50 EN55022 ClassB Average Limits 40 30 20 10 0 150 k 255 k 433 k 735 k 1.2 M 2.1 M Frequency (Hz) 3.6 M 6.1 M 10.4 M 17.7 M 30.0 M Figure 18. CPE1U96 Conducted Emissions using above specified input filter, Vin = 96V, Full Resistive Load

- 13 - MODULE PIN ASSIGNMENT: PIN # DESIGNATION NOTES 1 V IN (+) 1) All dimensions in inches [mm] Tolerances:.xx ± 0.02 [.x ±.5] 2 On/Off.xxx ± 0.010 [.xx ±.25] 3 V IN (-) 2) Input, on/off control and sense/trim pins are Ø 0.040 [1.02] with Ø 0.070 [1.77] standoff shoulders. 4 V OUT (-) 3) Output pins are Ø 1.57 mm (0.062 ) with Ø 0.093 [2.36] shoulders (note, shoulder sits.008 above mounting surface) 5 Sense (-) 4) All pins are gold plated with nickel under plating. 6 Trim 5) Weight: 22.4 g (0.79 oz.) open frame 39.1 g (1.38 oz.) baseplate model 7 Sense (+) 6) Workmanship: Meet or exceeds IPC-A-610 Class II 8 V OUT (+) MECHANICAL OUTLINE:

- 14 -

- 15 - ORDERING INFORMATION: Output Product Identifier Current Output Voltage Input Voltage Enable logic option Additional features CPE 1 D 96 N or P S or B Cool Power Eighth Brick 1.2A 24V 40 150V N = Negative P = Positive S = Surface Mount B = Baseplate Option Rev 1.0, 3-October-17