KFS. Flap-type flow meter. Design and range of application

Similar documents
Design and applications

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Inductive sensor slot-type SI2-K08-AP7

Metal tube variable area flowmeters for gases, liquids and steam

Target disk flowmeter for liquids and gases

SALES SERVICE +358 (0)

Full Metal Variable Area Flowmeter and Counter Model BGF

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Float Switches with Permanent Magnet For Vertical Installation Model RSM

OPTIFLUX 5000 Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet

Level gauges Series LT Level indicator, switch and transmitter for liquids

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

OPTIFLUX 5000 Technical Datasheet

BGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Coriolis Massflowmeter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

OPTIFLUX 1000 Technical Datasheet

Digital flow transmitter for continuous flow measurement

Relative and absolute pressure transmitter type 528

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

BATCHFLUX 5500 C Technical Datasheet

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

OPTIMASS 1000 Technical Datasheet

Page Type Resolution (mm) min. max. Output

Positioner with HART Communication Type 3780

TMU. Coriolis Mass Flow Meter. for liquids and gas

INLINE flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

ED701 General Industry Pressure Transmitter

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Positive Displacement Flow sensors

Submersible pressure sensor For oils and fuels Model LF-1

Digital inductive conductivity transmitter

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

INSERTION paddle wheel flowmeter for continuous flow measurement

VTM Local Display Unit with Frequency and Analogue Output

The transducer component converts the measured signal and displays the actual value.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Coriolis Mass Flow Meter Model TM

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

IP26 Series Current to Pneumatic Converter

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Flow Measurement SITRANS F VA. SITRANS FVA250 variable area meter. 4/382 Siemens FI Overview

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Level and Pressure. Product Information. Vibrating level switches

Digital flow ELEMENT transmitter for continuous flow measurement

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Submersible pressure sensor For water and wastewater Model LW-1

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Coriolis Massflowmeter

Resistance thermometers for process technology

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

WATERFLUX 3070 Technical Datasheet

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Relative and absolute pressure transmitter type 528

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Vortex Meter VTX2. P e

INLINE flowmeter for continuous flow measurement

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Non-Submersible Industrial Pressure Transducer

SITRANS P. Transmitters for level. Introduction 1/42. Application

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

INLINE flowmeter for continuous flow measurement

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

OPTIWAVE 1010 Technical Datasheet

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

OPTISONIC 7300 Technical Datasheet

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Fluxi 2000/TZ. Turbine Gas Meter

Operating Instructions

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Electro-Magnetic Flowmeters COPA-XE

... for hydraulic and general applications in hazardous areas

Electromagnetic Flow Transmitter

Density meter DWF. Device description. Device description DWF Page 1 of 22

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Trimod Besta Level Switch type I 8 / IE9 8

Transcription:

Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated to customer requirement and fitted with a product-specific scale. For process control purposes, the measuring device can be equipped with limit contacts or a measuring transducer with electrical analog output. The 50 mm thick ring features a half-round plate that is fastened to a rotating spindle. The angle between flap and ring changes according to the rate of flow, and a breakaway-proof magnetic coupling transfers the movement to an external pointer. The standard indicator is housed in a round stainless steel casing with bayonet lock and can optionally be equipped with contacts. The casing of the indicator part with integrated 4-20mA output is constructed of die-cast aluminium. suitable for H 2 O, acids, alkaline solutions and gases spring-loaded flap horizontal or vertical direction of flow largely independent of viscosity limit contacts, optional analog output 4-20 ma, optional, optional

Type series Materials -IK1 -IK2 -IKS1 -IKS2 -RK1 -RK2 -EM Ex -IK1 Ex -EM EEx local mechanical indicator with one inductive contact with two inductive contacts with one electronic contact with two electronic contacts with one reed contact with two reed contacts with 4-20 ma output local mechanical indicator, with one inductive contact, with 4-20 ma output, Material, ring Wetted internals Wetted gasket 2) DN Steel 1.4571 Sil 4400 25-600 Stainless steel 1.4571 Sil 8200 25-600 PVC 1.4571 1) EPDM 25-300 P P 1.4571 1) EPDM 25-300 PVDF 1.4571 1) Viton 25-300 Indicator part -EM Scale casing Stainless steel 1.4301 Aluminium, painted Pointer Aluminium, painted Aluminium, painted Scale Aluminium, coated Aluminium, coated Pane PMMA, opt. glass Float glass 1) optionally Hastelloy C4 2) others on request Rubber coating on request Technical data Measuring ranges Measuring accuracy 5% FS Scale in physical units, e.g.: l/h, m³/h Length of scale max. 95 mm Turndown ratio min. 1 : 10 Degree of protection, IP 66 (IP 67 for -EM) indicator part Corrosion protection for Epoxy, stove enamelled, steel version colour: blue, RAL 5017 Mounting length Standard: 50 mm Special spring: 60mm Connections Mounting between welding neck flanges to DIN 2501 optionally acc. to ANSI 150 lbs, JIS 150 lbs, others on request Steel/stainless steel version 1) Allowable media - 70 C... + 200 C PN 6/10 temperatures - 20 C... + 70 C PN 6/10 ( Ex and -IK1 Ex) 2) Standard pressure stage PN 6/10 optionally PN 16/25/40 (no surcharge) PVC version 1) (not suitable for hazardous areas) Allowable media 0 C... + 20 C at 10 bar temperatures 0 C... + 40 C at 6 bar Allowable operating pressure PN 6/10 PP version 1) (not suitable for hazardous areas) Allowable media 0 C... + 20 C at 10 bar temperatures 0 C... + 80 C at 1.5 bar Allowable operating pressure PN 6/10 PVDF version 1) (not suitable for hazardous areas) Allowable media - 40 C... + 20 C at 10 bar temperatures - 40 C... + 140 C at 2 bar Allowable operating pressure PN 6/10 Standard measuring ranges, water at 20 C DN Measuring range [m 3 /h] H 2 O 25 0,5-7 1-12 32 0,5-8 1,8-18 4-40 40 0,6-6 1,6-16 3-30 5-50 50 0,8-8 1,8-18 3-35 5-50 65 2-18 4-40 6-60 9-90 11-110 80 2-20 4-40 6-60 10-100 12-120 100 5-50 8-80 12-120 14-140 20-200 125 5-55 8-80 12-120 14-140 20-200 35-350 150 6-60 10-100 14-140 18-180 22-220 35-350 200 12-120 15-150 20-200 25-250 40-400 250 18-180 25-250 30-300 40-400 300 20-220 25-250 30-300 50-500 350 50-500 Special measuring ranges,water at 20 C DN Measuring range [m 3 /h] H 2 O 200 60-600 250 60-600 300 60-650 90-900 350 70-700 90-900 400 60-600 75-750 110-1100 500 70-700 100-1000 135-1350 600 80-800 125-1250 165-1650 Measuring ranges for other media and operating conditions on request. 1) The process fluid must not freeze 2) Where insulation measures have been carried out to pipeline and measuring part, 70 C... + 200 C are also possible

Standard measuring ranges, air at STP (0 C and 1013 mbar) DN Measuring range [m 3 /h] air at STP Minimum range Maximum range 25 10-100 30-300 32 10-100 30-300 40 10-100 40-400 50 10-100 75-750 65 18-180 80-800 80 20-200 100-1000 100 25-250 220-2200 125 25-250 260-2600 150 30-300 300-3000 200 40-400 300-3000 250 100-1000 400-4000 300 150-1500 500-5000 Intermediate measuring ranges possible The measuring ranges for the -EM Series slightly differs from the above values. More precise details supplied on request. Options Limit contacts Inductive contact IK1 and IK2 Limit contact with inductive slot initiator, optionally The pointer in the indicator activates a built-in inductive contact by means of a metal vane. The limit contact is adjustable over the full measuring range. A maximum of 2 contacts can be built into one. The contact point is indicated on the flow meter scale by a pointer. IK1 IK2 Contact data Function Version with one contact Version with two contacts Inductive slot initiator to NAMUR DIN 19233, two-wire Switching function NC or NO contact Slot width 2.0 mm Hysteresis 1.0 % v.e... 10.0 % v.e Repeat accuracy 2.0 % Temperature drift ±10 % Ambient temperature -25 C... +70 C Voltage nom. 8.2 VDC Switching frequency 2.5 khz Switching performance bistable Nominal voltage 8 V DC via isolation switching amplifier KFA Power consumption active area uncovered 2,1 ma active area covered 1,2 ma Ambient temperature -25 C... +70 C Polarity reversal protection yes Certification to KEMA 01 ATEX 1264X Inner inductance (Li) / 41 nf / 266 µh capacitance (Ci) * values for cable assemblies up to 10m Contact marking II 1 G EEx ia IIC T6 (max. Ui = 15V, Ii = 60 ma, Pi = 100 mw) Limit contact with inductive slot initiator for PLCs, IKS1 and IKS2 The pointer of the flow meter activates the inductive contact that is built into the indicator casing by means of a metal vane. The limit contact is adjustable over the full measuring range. A maximum of 2 IKS contacts can be built into a. The contact point is indicated on the meter scale by a pointer. The IKS version is particularly suitable for direct connection to PLCs. IKS1 Version with one contact IKS2 Version with two contacts Contact Inductive slot initiator Switching function NC or NO Switching performance bistable Supply voltage 24 V DC Current switched IA 100 ma Open-circuit power consumption 10 ma Ambient temperature -25 C... +70 C Explosion protection no Voltage drop (bei Imax) 1,2V

Reed contact RK1 and RK2 The flow meter can optionally be equipped with a limit contact RK for flow monitoring and control purposes. The limit contact is adjustable over the full measuring range. RK1 RK2 Contact Switching function Switching performance Voltage switched Current switched Contact rating Ambient temperature Version with one contact Version with two contacts Reed contact, floating NC / NO bistable max. 140 V AC / 200 V DC max. 0,25 A max. 5 VA, 3 W -25 C... +105 C Power supply 24V DC Measuring signal 4 to 20 ma for 0 to 100% flow value > 20.8 ma for alarm status Supply power influence < 0,1 % Ext. resistance dependence < 0,1 % Temperature influence < 5 µa/k max. external resistance / 0 (250 *) to 800 Ohm load impedance Ambient temperature -25 C... +60 C * With HART TM communication, these are minimum values. Low-voltage directive Above 50 VAC/75 VDC, the contacts are subject to the EC low-voltage directive. The user is required to check their application accordingly. Explosion protection according to Directive 94/9/EC: ATEX The following versions are also available in the type-tested hazardous-duty variant for Zone 1 and 2 of device categories 2 and 3, atmosphere G, in compliance with Directive 94/9/EC (ATEX 95): Electrical measuring transducer EM The electrical measuring transducer generates a current of 4 to 20 ma in two-wire technology that is proportional to the instantaneous flow rate. The transducer is factory-calibrated on the basis of the flow measuring range. The calibration values, used for linearization of the measuring transducer, are stored in a memory chip. A protective extra-low voltage (PELV) with galvanic isolation to VDE 0100 Part 410 is required as power supply. All instruments connected to the measuring circuit (indicators, recorders) are connected in series, and together may not exceed the maximum external resistance. The EM features reverse voltage protection. Ex -IK1 Ex -EM EEx mechanical local indicator, with one inductive contact, with 4-20 ma output,

Dimensions Standard Note: The flap axis for DN32 and DN25 devices is located 9mm above the ring axis! NPS = Nominal pipe size acc. to ANSI/ASTM DN d 4 A 1) Weight [kg] NPS d 4 A 1) Steel PVC 25 68 202 3,8 2,0 1" 51 199 32 78 206 3,8 2,0 1 1/4" 64 204 40 88 206 3,8 2,0 1 1/2" 73 206 50 102 211 3,9 2,1 2" 92 212 65 122 219 5,0 2,3 2 1/2" 105 217 80 138 226 5,6 2,5 3" 127 225 100 158 236 6,4 2,7 4" 157 237 125 188 249 8,0 2,8 5" 186 250 150 212 261 8,8 3,3 6" 216 263 200 268 286 11,4 3,7 8" 270 287 250 320 311 13,0 4,5 10" 324 313 300 370 336 22,0 4,9 12" 381 338 350 430 376 29,3-400 482 401 31,5-500 585 451 39,0-600 685 501 45,5 - All dimensions in mm 1) The PVC / PP / PVDF versions deviate in part from the standard.

with contacts (IK1, IK2, IKS1,...) Note: The flap axis for DN32 and DN25 devices is located 9 mm above the ring axis! NPS = Nominal pipe size acc. to ANSI/ASTM DN d 4 A 1) Weight [kg] NPS d 4 A 1) Steel PVC 25 68 249 3,8 2,0 1" 51 246 32 78 253 3,8 2,0 1 1/4" 64 251 40 88 253 3,8 2,0 1 1/2" 73 253 50 102 258 3,9 2,1 2" 92 259 65 122 266 5,0 2,3 2 1/2" 105 264 80 138 273 5,6 2,5 3" 127 272 100 158 283 6,4 2,7 4" 157 284 125 188 296 8,0 2,8 5" 186 297 150 212 308 8,8 3,3 6" 216 310 200 268 333 11,4 3,7 8" 270 334 250 320 358 13,0 4,5 10" 324 360 300 370 383 22,0 4,9 12" 381 385 350 430 423 29,3-400 482 448 31,5-500 585 498 39,0-600 685 548 45,5 - All dimensions in mm 1) PVC / PP / PVDF versions deviate in part from the standard.

-EM Note: The flap axis for DN32 and DN25 devices is located 9mm above the ring axis! NPS = Nominal pipe size acc. to ANSI/ASTM DN d 4 A 1) Weight [kg] NPS d 4 A 1) Steel PVC 25 68 233 3,8 2,0 1" 51 233 32 78 236 3,8 2,0 1 1/4" 64 238 40 88 242 3,8 2,0 1 1/2" 73 240 50 102 247 3,9 2,1 2" 92 246 65 122 253 5,0 2,3 2 1/2" 105 251 80 138 260 5,6 2,5 3" 127 259 100 158 270 6,4 2,7 4" 157 271 125 188 283 8,0 2,8 5" 186 284 150 212 295 8,8 3,3 6" 216 297 200 268 320 11,4 3,7 8" 270 321 250 320 345 13,0 4,5 10" 324 347 300 370 370 22,0 4,9 12" 381 372 350 430 395 29,3-400 482 420 31,5-500 585 485 39,0-600 685 535 45,5 - All dimensions in mm 1) PVC / PP / PVDF versions deviate in part from the standard.

The equipment from KIRCHNER has been tested in compliance with the applicable CE-regulations of the European Community. The respective declaration of conformity is available on request. The KIRCHNER QM-System will be certified in accordance with DIN-EN-ISO 9001:2000. The quality is systematically adapted to the increasing demands.