Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Similar documents
06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Binary Output without Power Supply Series 9176

Binary Output Series 9175

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolating Repeater Input Series 9163

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.

Fieldbus Isolating Repeater Series 9185/11

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Isolators A3/1.

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital I/O Coupler (4-wire) Series 9413/21

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital Input Output Module for Zone 2 Series 9470/33

Temperature Input Module for Zone 1 Series 9482/32

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Remote I/O. 74 Remote I/O. Remote I/O System

Single-Channel Safety Barriers Series 9001

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Technical Data. General specifications. Rated operating distance s n 3 mm

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Safety Instructions Nivotester FTC625, FTC325

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Technical Information Barrier RB223

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Motor Protection Circuit Breaker Series 8146/5-V27

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Signal Beacon - LED Series 6162

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Certificate of Compliance

Inductive sensor slot-type SI2-K08-AP7

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Temperature Transmitter itemp RTD DIN rail TMT 127

Field indicator for current loops with HART communication Models DIH50, DIH52

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Assembly. Front view. Parametrization interface. Power Bus

Sicherheit, auf die Sie sich verlassen können

Temperature Measurement Transmitters for mounting in sensor head

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Actuators Series 8602/3

onlinecomponents.com

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Switch Power Rail

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Temperature Measurement

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Signal conditioner - MACX MCR-UI-UI-NC

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp RTD DIN rail TMT 127

itemp PA TMT184 Technical information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

Temperature Measurement Transmitters for mounting in sensor head

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

0 2 1 â Ó. itemp HART TMT182. Technical Information

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Temperature head transmitter itemp TC TMT 188

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

A6500-UM Universal Measurement Card

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Head mounted Temperature Transmitter TF02/TF02-Ex

Operating Manual. isolate501

Assembly. Front view. Switch Power Rail

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Technical Information RMA42

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

... for hydraulic and general applications in hazardous areas

Transcription:

> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function: The power supplies are used for the intrinsically safe operation of field devices e.g. 3- or 4-wire transmitters, solenoid valves, light barriers, controllers and more. ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x Installation in x *) x *) *) Restrictions see table explosion protection WebCode 9143A Isolators /1

Selection Table Version Auxiliary power Ex i output Order number Nominal voltage U N Max. nominal current I N Ex i power supply 4.0... 5.6 V 160 ma 9143/10-065-200-10s 8.8... 9.1 V 200 ma 9143/10-099-220-10s 8.7... 9.5 V 200 ma 9143/10-104-220-10s 9.4... 10.4 V 180 ma 9143/10-114-200-10s 9.5... 11.8 V 130 ma 9143/10-124-150-10s 12.5... 14.7 V 140 ma 9143/10-156-160-10s 14.6... 17.6 V 35 ma 9143/10-187-050-10s 18.9... 23.0 V 40 ma 9143/10-244-060-10s 14.6... 17.6 V 35 ma 9143/10-187-050-20s 12.5... 14.7 V 140 ma 9143/10-156-160-20s 9.5... 11.8 V 130 ma 9143/10-124-150-20s 9.4... 10.4 V 180 ma 9143/10-114-200-20s 8.7... 9.5 V 200 ma 9143/10-104-220-20s 4.0... 5.6 V 160 ma 9143/10-065-200-20s 18.9... 23.0 V 40 ma 9143/10-244-060-20s The order code above is with screw type removable terminals. /2 Isolators

Explosion Protection Global (IECEx) Gas, dust and mining IECEx BVS 12.0009X IECEx BVS 12.0009X Ex na [ib Gb] IIC/IIB T4 Gc [Ex ib Db] IIIC [Ex ib Mb] I Europe (ATEX) [Ex ib Gb] IIC/IIB [Ex ib Db] IIIC [Ex ib Mb] I Gas, dust and mining BVS 05 ATEX E 152X BVS 05 ATEX E 152X Certifications and certificates Certificates E II 3 (2) G Ex na [ib Gb] IIC/IIB T4 Gc E II (2) D [Ex ib Db] IIIC E I (M2) [Ex ib Mb] I E II (2) G [Ex ib Gb] IIC/IIB E II (2) D [Ex ib Db] IIIC E I (M2) [Ex ib Mb] I IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Belarus (TR) Ship approval DNV Safety data Version 9143/10-065-200-.0. 9143/10-099-220-.0. 9143/10-104-220-.0. 9143/10-114-200-.0. Max. voltage U o 6.5 V 9.9 V 10.4 V 11.4 V Max. current I o 200 ma 220 ma 220 ma 200 ma Max. power P o 1.3 W 2.178 W 2.288 W 2.28 W capacitance C o IIC 25 mf 3 mf 2.4 mf 1.64 mf IIB 570 mf 20.2 mf 16.8 mf 11.2 mf inductance L o IIC 0.82 mh 0.30 mh 0.24 mh 0.16 mh IIB 3.71 mh 1.7 mh 1.5 mh 1.4 mh Internal capacitance C i negligible Internal inductance L i negligible Insulation voltage U m 253 V AC Further information and combination of values, see certification. Version 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0. 9143/10-244-060-.0. Max. voltage U o 12.4 V 15.6 V 18.7 V 24.4 V Max. current I o 150 ma 160 ma 50 ma 60 ma Max. power P o 1.86 W 2.496 W 0.935 W 1.464 W capacitance C o IIC 1.24 mf - - 0.27 mf - - IIB 7.9 mf 3.03 mf 1.64 mf 0,88 mf inductance L o IIC 0.17 mh - - 0.06 mh - - IIB 2.08 mh 0.351 mh 15.5 mh 534 mh Internal capacitance C i Internal inductance L i Insulation voltage U m negligible negligible 253 V AC V Further parameters Further information and combination of values, see certification. Installation in Zone 2, 22 and in the safe area in Zone 22 and in the safe area Further information see respective certificate and operating see respective certificate and operating instructions instructions Isolators /3

Technical Data Electrical data Auxiliary power Rated voltage U N Voltage range AC: 20... 28 V 85... 230 V AC DC: 18... 35 V Frequency range AC: 48... 62 Hz DC: - - 48... 62 Hz Reverse polarity protection AC: - - DC: yes Indication LED green LED green Power consumption Version 9143/10-065-200-.0. 9143/10-099-220-.0. 9143/10-104-220-.0. 9143/10-114-200-.0. 24 V DC 2.6 W 5.0 W 5.0 W 4.6 W 115 V AC 2.3 VA - - 4.0 VA 3.7 VA 230 V AC 3.3 VA - - 4.6 VA 4.5 VA Power dissipation determined for nominal current condition. Version 9143/10-124-150-.0. 9143/10-156-160-.0. 9143/10-187-050-.0. 9143/10-244-060-.0. 24 V DC 3.3 W 4.0 W 2.0 W 2.8 W 115 V AC 2.8 VA 4.0 VA 2.0 VA 2.6 VA 230 V AC 3.5 VA 4.9 VA 3.2 VA 3.8 VA Power dissipation determined for nominal current condition. Current limitation If the max. nominal current is reached the output voltage is set to 0 V. Galvanic separation Test voltage under regulations EN 60079-11 Output to power supply 1.5 kv AC Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no < 85 % at T a > 40 C condensation) Mechanical data Connection Connection single-wire - rigid - flexible - flexible, end covering sleeves (without / with plastic sleeving) Connection two wires - rigid - flexible - flexible, end covering sleeves Weight approx. 170 g Mounting type on DIN rail (NS35/15, NS35/7.5) Mounting orientation horizontal or vertical Enclosure IP30 Terminals IP20 Enclosure material PA 6.6 Fire resistance (UL-94) V0 0.2... 2.5 mm 2 0.2... 2.5 mm 2 0.25... 2.5 mm 2 0.2... 1 mm 2 0.2... 1.5 mm 2 0.25... 1 mm 2 /4 Isolators

Electrical connection Connection diagram 85... 230 V Typ 9143/..-...-...-20. Hazardous area Zone 1 Safe area Field device ISpac Isolator Control system Typ 9143/..-...-...-10. Hazardous area Zone 1 Safe area pac-bus Zone 2 10597E01 Field device ISpac Isolator Control system 10598E01 Dimensional Drawing (All Dimensions in mm / inches) - Subject to Alterations X 99 mm / 3.90 35,2 mm / 1.39 Screw terminals Dimension X 108 mm / 4,25 in 122 mm / 4.80 114,5 mm / 4.51 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 10599E00 Isolators /5