HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Similar documents
Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

NJWA - Harmonics and Drives Proper System Design

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Harmonic control devices

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

Reliable power onboard and offshore

Understanding Input Harmonics and Techniques to Mitigate Them

How adjustable speed drives affect power distribution

7/15/2002 PP.AFD.08 1 of 28

How Harmonics have led to 6 Power Factor Misconceptions

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Harmonic Distortion and Variable Frequency Drives

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Effective Harmonic Mitigation with Active Filters

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

APPLICATION GUIDE. Harmonics in HVAC applications

Drives 101 Lesson 5. Power Input Terminology for a VFD

Low Pass Harmonic Filters

Power Factor & Harmonics

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

PFC Lite. How it works OMNIVERTER. OMNIVERTER November 14, 2015 Slide 1

MIRUS International Inc.

Technical Paper. Harmonic Distortion in Data Centers

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Harmonic control devices. ECE 528 Understanding Power Quality

ABB drives. Technical guide No. 6 Guide to harmonics with AC drives

ABB n.v. Power Quality Products, October 2014

Active Harmonic Filter (AF3)

Analysis of Harmonic Distortion in Non-linear Loads

Design and Simulation of Passive Filter

The increase in the application

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

CHAPTER 4 HARMONICS AND POWER FACTOR

Power Quality and Harmonic :Causes and Effects with Paper Mill Factory

22.0 Harmonics in Industrial Power Systems

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Thyristorised Automatic Power Factor

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Harmonic Filters and Reactors

Harmonic Filtering in Variable Speed Drives

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

LINEATOR. Advanced Universal Harmonic Filter

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants

Open-Delta Systems Affect Variable Frequency Drives

Caution - leakage currents! Leakage currents in fault-current protected environments

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

Economical Solutions to Meet Harmonic Distortion Limits[4]

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Introduction to Rectifiers and their Performance Parameters

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

THE FIRST STEP IN THE RESOLUTION OF VOLTAGE DISTORTION FOR SHARED GENERATORS AND MV UNDERSEA RING MAIN IN AN OFFSHORE OIL FIELD

Harmonic Distortion Effects and Mitigation in Distribution Systems

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

Harmonics White Paper

Harmonics Reduction using 4-Leg Shunt Active Power Filters

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Reducing Total Harmonic Distortion with Variable Frequency Drives

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

AGN 026 Harmonic Voltage Distortion

Phoenix DX Clean Power (18 Pulse) AC Drive

VARIABLE FREQUENCY DRIVE

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

APPLICATION NOTE. Applying Type DD60 Capacitors in Harmonic Filter Applications. Total Power Factor PF = cosine ɸ

GESS Industrial UPS System. Overview

High Voltage DC Transmission 2

ZENER ELECTRIC PTY LTD

Do Capacitor Switching Transients Still Cause Problems?

TOSHIBA International Corp

Effects of Harmonic Distortion I

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

16th NATIONAL POWER SYSTEMS CONFERENCE, 15th-17th DECEMBER,

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Principles for Controlling Harmonics

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

McGill Power Sales & Engineering, INC.

MERLIN GERIN KNOW HOW. THM filtering and the management of harmonics upstream of UPS

Active Harmonic Filter (AHF)

Evaluations of Energy Efficiency Improvement

Power Factor. Power Factor Correction.

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

DESIGN AND ANALYSIS OF ELIMINATION OF HARMONICS USING WIND ENERGY CONVERSION SYSTEMS

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

The Occurrence of Faults in Permanent Magnet Synchronous Motor Drives and its Effects on the Power Supply Quality

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

COMPARISON OF POWER QUALITY SOLUTIONS USING ACTIVE AND PASSIVE RECTIFICATION FOR MORE ELECTRIC AIRCRAFT

Transcription:

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Harmonic Basics 3 rd Harmonic Fundamental 5 t1h Harmonic 7 th Harmonic Harmonic Frequency Sequence 1 50Hz + 2 100Hz 0 3 150Hz 0 4 200Hz 0 5 250Hz - 6 300Hz 0 7 350Hz + : : : 19 950Hz + What are harmonics? Proliferated by power semiconductor devices Converts power (AC to DC, DC to AC, etc.) A harmonic is a component of a periodic wave having a frequency that is an integer multiple of the fundamental power line frequency Characteristic harmonics are the predominate harmonics seen by the power distribution system Predicted by the following equation: h C = characteristic harmonics to be expected n = an integer from 1,2,3,4,5, etc. p = number of pulses or rectifiers in circuit H c = np +/- 1

Multi-pulse Converters H n = NP +/- 1 H n = harmonic order present N,n = an integer P = number of pulses Harmonic Orders Present Harmonics present by rectifier design Type of rectifier Hn 1 phase 4-pulse 2 phase 4-pulse 3 phase 6-pulse 3 phase 12-pulse 3 phase 18-pulse 3 x x 5 x x x 7 x x x 9 x x 11 x x x x 13 x x x x 15 x x 17 x x x x 19 x x x x 21 x x 23 x x x x 25 x x x x 27 x x 29 x x x 31 x x x 33 x x 35 x x x x x 37 x x x x x 39 x x 41 x x x 43 x x x 45 x x 47 x x x x 49 x x x x

Harmonic Basics Nonlinear loads draw it Example: 6-Pulse VFD Converter Inverter DC bus M A B C

Harmonic Basics Why a concern? I h Loads Current distortion Added heating, reduced capacity in Transformers Conductors and cables Nuisance tripping of electronic circuit breakers (thermal overload) Blown fuses Detrimental to generators Heating of windings Detrimental to UPS UPS can t supply the current V h = I h x Z h

HARMONIC BASICS I h Loads V h = I h x Z h Voltage distortion Interference with other electronic loads Faulting to destruction Generator regulators can t function Shut downs Not compatible with PF caps Potential resonance condition Excessive voltage Overheating of PF correction capacitors Tripping of PF protection equipment Shutdown / damage to electronic equipment Encapsulated cables have stray capacitance Harmonics create resonance at generator Critical to limit harmonics before the encapsulated cable power feeds Especially on Ring Mains Systems

WHAT IS TOTAL POWER FACTOR? TPF = (DPF) x (Distortion factor) DPF = KW KVA f = Cos φ Distortion factor = 1 1 + THD(I) 2 = Cos δ TPF = Total or true power factor DPF = Displacement power factor Distortion factor = Harmonic power factor

TOTAL POWER FACTOR EXAMPLE Variable frequency drive (PWM type) DPF =.95 THD(I) = 35% (with DC choke or input line reactor) Distortion Factor =.9438 TPF =.95 x.9438 =.8966 1 =.9438 1 +.35 2

HARMONIC MITIGATION METHODS Typically applied per device Line reactors/dc bus chokes 5 th harmonic filters Broadband filters Multi-pulsing Active front end (AFE) converter Low Harmonic Drives System solution Active harmonic filter

INDUCTORS/TRANSFORMERS Converter-applied inductors or isolation transformers. (Line Reactor less expensive than transformer) Pros: ~ L Load Inexpensive & reliable Transient protection for loads Suppresses voltage notch of SCR rectifier Source 1st Z yields big TDD reduction (90% to 35% w/3% Z) Complimentary to active harmonic control Cons: Limited reduction of TDD at equipment terminals after 1st Z Reduction dependent on source Z Adds ~1% losses to individual system

5TH HARMONIC FILTER Inductor (L p ) and Capacitor (C) provide low impedance source for a single frequency (5 th ) Z s L s Must add more tuned filters to filter more frequencies V s L p C Load Inductor L s required to detune filter from electrical system and other filters If L s not present, filter is sink for all 5 th harmonics in system If L s not present, resonance with other tuned filters possible Injects leading reactive current (kvar) at all times may not need Losses of 1-2% typical

BROADBAND FILTERS ~ L L Load Source L p C Mitigates up to 13 th (19 th ) order Each inductor (L) => 8% impedance V drops ~ 16% at load Trapezoidal voltage to load Can only be used on diode converters Prevents fast current changes (only good for centrifugal loads) Capacitor (C) designed to boost V at load to acceptable level (injects leading VARs) Physically large High heat losses (~5%) Series device

Multi-Pulse Drives Y D D common DC bus / load Rectifiers with two (12 pulse) or three (18 pulse) input bridges fed by a transformer with two or three phase shifted output windings. Pros: Cons: Reduces TDD to 10% (12 pulse) & 5% (18 pulse) at loads Reliable High installation cost with external transformer Large footprint (even w/autotransformer) Series solution with reduction in efficiency (1-2% losses) One required for each product Cannot retrofit

ACTIVE FRONT END CONVERTER A C IGBT VFD DC Bus IGBT S o u r c e Filter Converter Inverter AC Motor Input filter required to attain 5% THDv

AFE CONVERTERS PCC EMC Filter Mains Choke Reactance, 4% Mains Filter Mains Filter Reactance, 12% Mains Pulse Converter, IGBT DC Bus Motor Pulse Inverter, IGBT M Motor

AFE CONVERTERS Disadvantages Larger and more expensive than 6 pulse drives Approximately twice the size & price Larger & more expensive than 18-P VFD Additional ~5% losses Mains voltage must be free of imbalance and voltage harmonics Generates more harmonics Without mains filter, THD(V) can reach 40% Requires short circuit ratio > 40 at PCC Transformers two times KVA of VFD Switched mode power supplies prohibited IGBT & SCR rectifiers prohibited on same mains No other nonlinear loads permitted Capacitors prohibited on mains

SYSTEM SOLUTION ACTIVE HARMONIC FILTER Applied to one or many nonlinear loads VFD, UPS, UV, DC drives, DC power supplies Provides DPF correction Leading or lagging More cost effective for multiple loads Saves space Lower total heat losses Not critical to operation

ACTIVE HARMONIC FILTER ~ I s CT I l Source I a L Reduced THDv everywhere AHF AHF Load Parallel connected I s + I a = I l Ia includes 2 nd to 25/50 th harmonic current I s <5% TDD

ACTIVE HARMONIC FILTER Pros: Load, bus, or PCC applied solution Easy sizing - not dependent upon system Z Scalable Dynamic - responds instantly Provides precise correction Parallel Installation Meets 5% TDD at equipment, bus, or PCC Considerations: May Require additional impedance (eg 3%) Requires individual branch circuit protection

DUAL MODE OPERATION I as = I h2 + I r 2 MOST ACTIVE HARMONIC FILTERS CAN PROVIDE BOTH HARMONIC MITIGATION AND POWER FACTOR CORRECTION EITHER SEPERATELY OR AT THE SAME TIME YOU CHOOSE I as = rms output current of AccuSine I h = rms harmonic current I r = rms reactive current Examples Ias Ih Ir 100.0 10.0 99.5 100.0 20.0 98.0 100.0 30.0 95.4 100.0 40.0 91.7 100.0 50.0 86.6 100.0 60.0 80.0 100.0 70.0 71.4 100.0 80.0 60.0 100.0 90.0 43.6 100.0 95.0 31.2

ELECTRONIC POWER SOLUTIONS OFFER NUMEROUS HARMONIC MITIGATION SOLUTIONS C O N T A C T E L E C T R O N I C P O W E R S O L U T I O N S A B O U T Y O U R H A R M O N I C M I T I G A T I O N S O L U T I O N