E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

Similar documents
E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

E650 Series 3. Electricity Meters IEC/MID Industrial and Commercial ZMD402AT/CT, ZFD402AT/CT. Technical Data

ZMD405AT/CT, ZFD405AT/CT, ZMD410AT/CT, ZFD410AT/CT

E35C. AD-FG/CG/GG Version 3.2. Technical Data. Communication Module Residential

MID energy meter B21 Single-phase energy meter, 65 A

Energy Management Energy Meter Type EM110

C series Product brief

Introduction DIN rail mounted electricity meters

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Energy Management Energy Meter Type EM110

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Energy Management Energy Meter GM3D

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

Energy Management Energy Meter Type EM340

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Electricity Meters Grid metering. Electricity Meter. Landis+Gyr E850 ZMQ200. Increased revenue through high accuracy and tailored grid functions

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Energy Management Energy Analyzer Type EM210 MID

High precision measurement system for current and voltage IHC-A/B-RM01/03

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Energy Management Energy Meter GM3T E GM3T-RS485 E

Energy Management Energy Meter Type EM21 72R Retro-Fit

DELTAplus. DIN Rail Mounted electricity meters. Technical Documentation

Energy Management Energy Analyzer Type EM111

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Subject to changes 11/2003 Page 1/7

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-SDS.22

Type CP-S, CP-C & CP-A Switch mode

Liquid level monitoring relay CM-ENS.2x

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Electronic timer CT-MFS.21

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Measuring centers MC7x0 series Multifunction Meter MC740

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

S650 Series 3. Electricity Meters IEC/MID Industrial and Commercial SMA300AR/CR. User Manual

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Delta Meter. ABB Cewe

ME162 Single-Phase Electronic Meter

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

UMG 103-CBM. Universal measurement device for DIN rails

Overcurrent Protection / 7SJ45

Energy Management Energy Analyzer Type EM210

SINGLE AND POLY-PHASE STATIC METERS

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

XUA1 - AC Voltage and phase balance relay

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

E65C. Communication Industrial and Commercial CU-P40, P41, P42. User Manual

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFS

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

AMIK 200 / 201 Technical Data Sheet

MDEX. on customized sensors. Technical information. Torque transducer. CS-T-04-MDEX Special features

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

02/11/2015

NETWORK ANALYZERS Analyzers

Utility Communications Teleprotection Equipment TPT-200

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Energy Management Energy Analyzer Type EM24 DIN

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Power Meter Series PM3200 Functions and characteristics

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

3-phase meter with direct connection and pulse or Modbus RS485 output

Three-phase monitoring relay CM-PVE

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Transcription:

Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR E550 Series 2 Technical Data Building on its tradition of industrial meters, Landis+Gyr is now bringing out the E550 Series 2, the latest generation of ZMG400 meters. The E550 Series 2 offers two electrical interfaces, advanced modem solution, event logging and anti-tampering functions. Date: 20.01.2012 File name: D000029746 E550 ZMG400xR Series 2 Technical Data en.docx Landis+Gyr D000029746 en h

2/10 Revision history Version Date Comments a 17.02.2010 First edition b e 23.07.2010 Continuous improvement f 01.12.2011 Corrected error in solid state output (DC deleted) g 02.12.2011 Corrected error in electromechanical output (DC deleted) h 20.01.2012 New extension boards 060 with 6 output contacts and 240 with 2 control inputs and 4 output contacts. Nothing in this document shall be construed as a representation or guarantee in respect of the performance, quality or durability of the specified product. Landis+Gyr accepts no liability whatsoever in respect of the specified product under or in relation to this document. Subject to change without notice. Landis+Gyr D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data

3/10 The E550 transformer connected I&C meters record active and reactive energy consumption in 1-phase 2-wire, 2-phase 3-wire, 3-phase 4-wire and 3-phase 3-wire (no neutral) networks. Basic Version The basic version provides energy registers for tariffication, red test diodes for active and reactive energy, an optical interface for meter reading and an electrical interface. Interfaces The Series 2 now supports two independent electrical interfaces. The meter supports RS232, RS485, RS422, CS and a specially powered RS232 to supply external modems. Installation support The monitoring of voltage, current, demand and power factor supports the installation. E550 Series 2 ZMG400AR/CR Technical specifications General Voltage Nominal voltage U n ZMG400xR 3 x 58/100 V to 69/120 V 3 x 110/190 V to 133/230 V 3 x 220/380 V to 240/415 V 3 x 58/100 V to 277/480 V Voltage range 80% to 115 % Un Frequency Nominal frequency f n 50 or 60 Hz Tolerance 2% Application 1 phase 2 wire; 2 phase 3 wire; 3 phase 4 wire, 3- phase 3-wire (no neutral) IEC-specific Data Current Nominal current I n selectable: 1 or 5 A Maximum current I max Metrological 1 A max. 600% Metrological 5 A max. 200% Thermal 1 A 8 A Thermal 5 A 12 A Short circuit 0.5 s 20 x I max ZMG410xR Active energy, to IEC 62053-21 class 1 Reactive energy, to IEC 62053-23 class 2 Measurement Behaviour Starting current ZMG405xR According to IEC Typical 0.1% I n 0.07% I n Starting current ZMG410xR According to IEC 0.2% I n Typical 0.14% I n The startup of the meter is controlled by the starting power and not by the starting current. Starting power in M-circuit Nominal voltage x starting current MID-specific Data single phase Current (for classes B and C) Reference current I ref selectable: 1.0, 5.0 A Minimum current I min Transitional current I tr Maximum current I max 0.01 x I ref 0.05 x I ref 2.0, 6.0, 10.0 A Measurement Accuracy to EN 50470-3 ZMG400xR classes B and C Measurement Accuracy ZMG405xR Active energy, to IEC 62053-22 class 0.5 S Reactive energy, to IEC 62053-23 class 1 Measurement Behaviour Starting current I st Class B: I st Class C: I st 0.002 or 0.01 A 0.001 or 0.005 A D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data Landis+Gyr

4/10 General Operating Behaviour Voltage failure (Power Down) Bridging time Data storage Switch off 0.5 s after another 0.2 s after approx. 10 s Fast transient burst test to IEC 61000-4-4 Current and voltage circuits 4 kv Auxiliary circuits > 40 V 2 kv Surge immunity test to IEC 61000-4-5 Current and voltage circuits 4 kv Auxiliary circuits > 40 V 1 kv Voltage restoration (Power Up) Function standby 3 phases after 4 s Function standby 1 phase after 5 s Detection of energy direction and phase voltage after 4 to 5 s Power Consumption Power consumption per phase in voltage circuit Phase voltage 58 V 100 V 277 V Active power (typical) 0.8 W 0.8 W 1.5 W Apparent power (typical) 1.0 VA 1.1 VA 2.5 VA Power consumption per phase in current circuit Phase current 1(6)A 1 A 6 A Active power (typical) 0.02 W 0.6 W Apparent power (typical) 0.01 VA 0.25 VA Phase current 5(10)A 5 A 10 A Active power (typical) 0.1 W 0.35 W Apparent power (typical) 0.02 VA 0.1 VA Environmental Influences Temperature range to IEC 62052-11 Operation class 1 40 C to +70 C Operation class 0.5 25 C to +70 C Storage 40 C to +85 C Temperature coefficient Range 25 C to +70 C Average value (typical) 0.012% per K At cos =1 (from 0.05 I b to I max ) 0.02% per K At cos =0.5 (from 0.1 I b to I max ) 0.03% per K Insulation Strength Insulation strength 4 kv at 50 Hz during 1 min. Impulse voltage 1.2/50 s to IEC 62052-11 Current and voltage circuits 10 kv Auxiliary circuits > 40 V 6 kv Protection class ll to IEC 60050-131 2 Calendar Clock Calendar Gregorian or Persian (Jalaali) Accuracy Backup time (power reserve) With supercap Charging time for 7 days backup time Charging time for max. backup time With battery 1 (calendar clock, display, readout) Battery type With battery 2 (calendar clock only) Battery type < 5 ppm > 21 days 24 h 300 h 10 years UM3-R6-AA 10 years CR2032 Display Characteristics LCD liquid crystal display Digit size in value field 9 mm Number of digits in value field up to 8 Digit size in index field 8 mm Number of digits in index field up to 7 Impermeability to IEC 60529 IP 53 Electromagnetic Compatibility Electrostatic discharges to IEC 61000-4-2 Contact discharge 8 kv Air discharge 15 kv Inputs and Outputs Control inputs Control voltage U S Max. input voltage Input current 100 to 277 V AC 320 V AC < 2 ma ohmic at 230 V AC Electromagnetic RF fields to IEC 61000-4-3 80 MHz to 2 GHz 10 and 30 V/m Radio disturbance According to IEC/CISPR 22 class B Output solid state solid state relay Voltage 12 to 277 V AC/DC Max. current 100 ma Max. switching frequency (pulse length 20 ms) 25 Hz Landis+Gyr D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data

5/10 Inputs and Outputs (cont.) Output electromechanical electromechanical relay Max switch voltage 277 V AC Max. switch current 6 A Rated current 5 A Optical test outputs active and reactive energy red LED Number 2 Meter constant selectable Communication Interface Optical interface to IEC 62056-21 serial, asynchronous, half-duplex Max. transmission rate 19,200 bps Protocols IEC 62056-21 and dlms RS232 Interface (powered and not powered) to DIN 61393 / DIN 66259 serial, asymmetric, asynchr., bidirectional Operating mode intelligent or transparent Nominal voltage 9 V DC Maximum voltage 15 V DC Minimum voltage 5 V DC Max. transmission rate 38,400 bps Protocols IEC 62056-21 and dlms Max. conductor length depending on environment and connecting cable 30 m Insulation resistance to meter 4 kv AC /50 Hz, 1 min Creep distance 6.3 mm RS485 Interface to ISO-8482 serial, symmetrical, half duplex Nominal input voltage common mode range 7 to +12 V DC Binary 1 state difference voltage < 0.2 V Binary 0 state difference voltage > 0.2 V Max. transmission rate 38,400 bps Max. number of slaves 31 Protocols IEC 62056-21 and dlms Max. conductor length depending on environment and connecting cable 1000 m Insulation resistance to meter 4 kv AC /50 Hz, 1 min Creep distance 6.3 mm CS Interface to IEC 62056-21 / DIN 66258 serial, bidirectional, current interface Nominal voltage without load 24 V DC Max. voltage without load 30 V DC Binary 1 state 10 30 ma Binary 0 state 2 ma Max. transmission rate 9600 bps Protocols IEC 62056-21 and dlms b Insulation resistance to meter 4 kv AC /50 Hz, 1 min Creep distance 6.3 mm RS422-Interface to ISO-8482 serial, symmetric, asynchronous, bidirectional Nominal input voltage common mode range 3 to +3 V DC Binary 1 state difference voltage < 0.2 V Binary 0 state difference voltage > 0.2 V Max. transmission rate 38,400 bps Max. number of slaves 10 Protocols IEC 62056-21 and dlms Max. conductor length depending on environment and connecting cable 1000 m Insulation resistance to meter 4 kv AC /50 Hz, 1 min Creep distance 6.3 mm Weight and Dimensions Weight External dimensions Width Height (with short terminal cover) Height (with standard terminal cover) Height (with extended hook) Depth Suspension triangle Height (with extended hook) Height (suspension eyelet open) Height (suspension eyelet covered) Width Terminal cover Short Standard Long (opaque, transparent) Standard Standard GSM ADP1 adapter RCR/FTY adapter approx. 1.5 kg 177 mm 244 mm 281.5 mm 305.5 mm 75 mm 230 mm 206 mm 190 mm 150 mm no free space 40 mm free space 60 mm free space 80 mm free space 110 mm free space 60 mm free space Material Housing Polycarbonate, partly glass-fibre reinforced Connections Phase connections cage type terminals Cross section 5.2 x 5.2 mm Recommended conductor cross section 4 to 6 mm 2 Screw head Pozidrive Combi No. 2 Screw dimension M4 x 15 D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data Landis+Gyr

6/10 Connections (cont.) Screw head diameter Tightening torque 5.6 mm 1.5 to 2 Nm RS232 Interface designation.02/.42/.62 RJ 12 Pin assignment 1 6 1 CTS 2 TxD 3 GND 4 DTR 5 RxD 6 DSR RS485 Interface designation.03/.43/.63/.37 RJ 12 Pin assignment 1 6 1 c (common ground) 2 a (data a) 3 b (data b) 4 b 5 a 6 c CS Interface designation.40/.42/.43 screw type terminals RS422-Interface designation.60/.62/.63 RJ 12 Pin assignment RS422 6 1 RS422 6 1 1 GND 2 U P (Data a) 3 U N (Data b) 4 U N (Data z) 5 U P (Data y) 6 GND The two RJ12 jacks of the RS422-interface are looped internally to permit connection of several meters. RS232 powered designation.07/.37 RJ 45 Pin assignment 1 8 1 NC 2 CTS 3 TxD 4 GND 5 NC 6 RxD 7 NC 8 V+ (10... 14 V) Voltage outputs U1, U2, U3, N screw type terminals Max. current 1 A Max. voltage of control inputs 300 V + - Meter Dimensions (standard terminal cover, suspension eyelet open) 6.2 75 40 26 190 206 281.5 150 177 75 The height of the suspension triangle with extended hook is 230 mm. See also User Manual. Landis+Gyr D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data

7/10 Terminal Dimensions 5.2 13 16 10 10 10 10 10 10 10 10 10 Terminal Layout Control inputs and output contacts Communication interfaces Voltage outputs U1 U2 U3 N Optical separation of phases Upper part of voltage inputs displaced back Voltage inputs Current circuits Control inputs and output contacts Communication interfaces Voltage outputs U1 U2 U3 N Optical separation of phases Upper part of voltage inputs displaced back Voltage inputs Current circuits D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data Landis+Gyr

8/10 designation ZMG 4 10 CR 4. 260 b. 43 S2 Network type ZMG 3-phase 4 wire network (M-circuit) Connection type 4 Transformer operated Accuracy class 10 05 Measured quantities CR AR Tariff functions 1 2 3 4 Active energy class 1 (IEC), B (MID) Active energy class 0.5 (IEC), C (MID) Active and reactive energy Active energy Energy rates, externally controlled Energy rates, internally controlled with time switch (TOU) Energy and demand rates, externally controlled Energy and demand rates, internally controlled with time switch (TOU) Number of control inputs / number of output contacts / special functions 000 020 060 240 260 440 041 Additional functions 0 3 4 7 a b No control inputs, no output contacts, no special functions 2 output contacts 6 output contacts 2 control inputs, 4 output contacts 2 control inputs, 6 output contacts 4 control inputs, 4 output contacts No control inputs, 4 output contacts, 1 output relay 5A None With software events With hardware and software events With load profile With load profile and software events With load profile, hardware and software events Interfaces 2 (Xx) and 1 (xx) (S2 = Series 2) 00 No interfaces 02 RS232 03 RS485 40 CS* 42 CS and RS232* 43 CS and RS485* *) only as.260x.4x or as.440x.4x **) only as.041x.6x ***) only as.020x.07,.041x.37,.240x.37 or as.060x.37 60 RS422** 62 RS422 and RS232** 63 RS422 and RS485** 07 Powered RS232*** 37 RS485 and Powered RS232*** Landis+Gyr D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data

9/10 D000029746 en h E550 Series 2 ZMG400AR/CR Technical Data Landis+Gyr

Contact: Landis+Gyr (Europe) AG Theilerstrasse 1 CH-6301 Zug Switzerland Phone: +41 41 935 6000 www.landisgyr.com