RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES. 32-Channel Thermocouple Measurement System

Similar documents
EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

EMX-4350 APPLICATIONS FEATURES A SMART PXI EXPRESS 625 KSA/S 4-CHANNEL DIGITIZER

EMX-1434 APPLICATIONS FEATURES A SMART PXI EXPRESS 4-CHANNEL KSA/S ARBITRARY WAVEFORM GENERATOR

Correlation of Voltage and Temperature Measurement

EX FEATURES. Stand-alone 48-channel unit with built-in Ethernet controller. Built-in bridge completion and Excitation

Features EX1629. High-performance Remote Strain Gage Measurement Unit. Overview. 48 programmable channels in a single unit

Model 865 RF / Ultra Low Noise Microwave Signal Generator

SCXI 8-Channel Isolated Analog Input Modules

Model 865-M Wideband Synthesizer

8248AU. 4-Ch Isolated Amplifier with Optional Bridge Conditioning FEATURES TYPICAL APPLICATIONS

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

Model 865-M Wideband Synthesizer

PC-supported measurement

Kistler LabAmp for DynoWare

ELG3336 Design of Mechatronics System

Model ½-Digit Multimeter Datasheet

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ni.com Sensor Measurement Fundamentals Series

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

NI PXI/PXIe-2527 Specifications

FC Series Signal Conditioners

Developer Techniques Sessions

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Technical Datasheet UltraScope USB

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

MECE 3320 Measurements & Instrumentation. Data Acquisition

Ethernet-Based Temperature, Voltage and Strain Measurement Modules

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

HE693THM884/888 High Resolution Thermocouple Module Product Specifications and Installation

DS H01 DIGITAL SYNTHESIZER MODULE SYSTEM SOLUTIONS. Features Applications 174 x 131 x 54 mm. Technical Description

Model 845-M Low Noise Synthesizer

GFT Channel Digital Delay Generator

Model 2450 Interactive SourceMeter Instrument

Low-G 222 Series OCXO

7600 Isolated Digitizer and Receiver

GFT1012 2/4 Channel Precise Slave Generator

EKT 314/4 LABORATORIES SHEET

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

90 Day TCAL ±5 C. = channel 2 reading channel 2 accuracy channel 2 reading

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

imc C-SERIES: CS-3008-N, CL-3016-N

Model 855 RF / Microwave Signal Generator

MX440A. Data Sheet. Universal amplifier. Special features. Block diagram Digital platform. B en

PSI Temperature Scanners

USB-2404-UI Specifications

VT1419A Multifunctional Plus Measurement and Control Module

2750 Integra Mainframes

technicalnote Implementing Advanced Cold-Junction Compensation Techniques to Improve Temperature Measurement Accuracy Headline Type K Thermocouple

imc C-SERIES: CS-1016-N, CL-1032-N

Model 2450 Interactive SourceMeter Instrument

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

GFT1504 4/8/10 channel Delay Generator

Picture 1 PC & USB Connection

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

PACSystems* RX3i IC695ALG600-EE Universal Analog Input Module

Vibration Transducer Calibration System

Specifications for the NI PXI/PCI-6552/6551

PACSystems* RX3i IC695ALG600-DD

NI 6143 Specifications

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

PACSystems* RX3i IC695ALG600

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

MX1601B-R. Ultra rugged Standard Amplifier. Data sheet. Special features. Block diagram

Fluke 83V and 87V Digital Multimeters

NEW! AOIP FD5 Advanced Digital Data Logger

Agilent 34410A and 34411A Multimeters Setting the Standard for Next Generation Benchtop and System Testing

MX1601B R. Data Sheet. Ultra-rugged Standard Amplifier

EX CHANNEL, PRECISION THERMOCOUPLE INSTRUMENT USER S MANUAL. P/N: Released April 22, VTI Instruments Corp.

Portable Multi-Channel Recorder Model DAS240-BAT

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

WaveStation Function/Arbitrary Waveform Generators

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

PFXLM4B01 D * * (1) (2) (3) (4)

Agilent U2300A Series USB Modular Multifunction Data-Acquisition Devices

IP65 Splash and Dust Proof Stepping Motors

8558A 8 1/2 Digit Multimeter

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

QUAD PROGRAMMABLE FILTER/AMPLIFIERS For the and Signal Conditioning Systems

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

SSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Note Using the PXIe-5785 in a manner not described in this document might impair the protection the PXIe-5785 provides.

High Resolution Thermocouple Module Product Specifications and Installation Data

Analog Signal Conditioning Accessories

GE Fanuc IC695ALG312. Rx3i PacSystem

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

These specifications apply to the PXIe-5113 with 64 MB and 512 MB of memory.

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Advanced Test Equipment Rentals ATEC (2832) CIBANO in-1 test system for medium- and high-voltage circuit breakers

Agilent U9397A/C FET Solid State Switches (SPDT)

DIN Thermocouple Conditioner MODEL 5M14(V)

Wind Turbine Analysis System - Type 3652 MKII & MKIII

NI PXI-4461 Specifications

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

Transcription:

WWW.VTIINSTRUMENTS.COM RX1032 PRECISION TEMPERATURE MEASUREMENTS FOR RUGGED ENVIRONMENTS FEATURES 32-Channel Thermocouple Measurement System Advanced CJC Implementation 1000 Sample/sec/channel Scan Rate Precise Distributed Measurement Synchronization with IEEE-1588 Rugged Design Broad Operating Temperature Range IP65 Environmental Rating Ethernet Connectivity via LXI Open Industry Standard IVI-COM, IVI-C, LabVIEW Driver Support 1 2016 VTI Instruments Corporation. All rights reserved.

RX1032 OVERVIEW The RX1032 thermocouple measurement instrument is a ruggedized version of the popular EX1000 series, the most advanced, full-featured data acquisition solutions available on the market today. The RX1032 unit provides superior measurement accuracy and repeatability by implementing fully integrated signal conditioning and advanced cold junction compensation (CJC). The RX1032 series uses military grade connectors for power and connectivity while thermocouple and sensor inputs are routed through a protected entry to a screw terminal panel for quick and easy connectivity. The rugged construction of the enclosure enables the measurement system to be mounted on test pylons, in test cells and in other harsh environments. SCALABLE FOR HIGH- SPEED SYNCHRONIZED DATA ACQUISITION The RX10XX family supports easy integration and synchronization of multiple devices through an industry standard IEEE-1588 implementation. Multiple RX1032 instruments can easily be distributed and placed extremely close to the measurement points of interest, reducing the length of analog cable, minimizing errors induced by noisy environments. All measurement data is returned with IEEE-1588 timestamp codes with typical accuracies of <200µS ensuring that the acquired data is tightly correlated across the entire test article. APPLICATIONS Large Scale Engine Test Harsh Environment Health Monitoring HALT / HASS Rocket Motor Reliability Wind Tunnel Test COLD JUNCTION COMPENSATION The heart of any truly accurate thermocouple measurement system is the CJC implementation. The RX1032 combines multiple precision thermistors, a significant thermal mass, and careful parts placement to provide world-class measurement performance. 2

SPECIFICATIONS CHANNELS CHANNELS 32 differential inputs CHANNEL TYPES Thermocouple inputs: J, K, T, E, S, R, B, N SAMPLING RATE 1000 Sa/sec/ch maximum TEMPERATURE RESOLUTION <0.1 C TEMPERATURE ACCURACY See Thermocouple Accuracy table TEMPERATURE NOISE, PEAK-TO-PEAK 0.08 Cpp typical (J, K, T, E) PROGRAMMABLE FILTERS BESSEL (2 POLE) BUTTERWORTH (1 POLE) COMMON MODE REJECTION RATIO 4 HZ FILTER 1 KHZ FILTER 4 Hz, 15 Hz, 40 Hz, 100 Hz, 500 Hz (-3 db cutoff frequency) 1000 Hz (-3 db cutoff frequency) DC: 100 db MINIMUM; (50/60) HZ: 140 db TYPICAL, 120 db MINIMUM DC: 100 db MINIMUM; (50/60) HZ: 100 db TYPICAL, 80 db MINIMUM 3

LXI SPECIFICATIONS CLOCK SPECIFICATIONS CLOCK OSCILLATOR ACCURACY SYNCHRONIZATION ACCURACY TIMESTAMP ACCURACY RESOLUTION ±50 PPM REPORTS SYNCHRONIZED WHEN < ±200 μs OF THE 1588 MASTER CLOCK AS GOOD AS TIME SYNCHRONIZATION DOWN TO 50 ns 25 ns IEEE 1588- BASED TRIGGER TIMING ALARM TRIGGER TIME ACCURACY RECEIVE LAN [0-7] EVENT TRIGGER TIME ACCURACY FUTURE TIMESTAMP PAST/ZERO TIMESTAMP AS GOOD AS TIME SYNCHRONIZATION DOWN TO 50 μs 50 μs AS GOOD AS TIME SYNCHRONIZATION DOWN TO 50 μs 50 μs TYPICAL 1 ms MAXIMUM HARDWARE TRIGGER TIMING LXI TRIGGER BUS DIO BUS 55 μs TYPICAL DIO BUS 57 μs TYPICAL ENVIRONMENTAL SPECIFICATIONS TEMPERATURE -40 C TO +71 C (REDUCED ACCURACY), 0 C TO +50 C (FULL OPERATING ACCURACY) HUMIDITY IP 65 RATED ENCLOSURE, 5% TO 95% ALTITUDE SHOCK AND VIBRATION UP TO 4600 M CONFORMS TO MIL-PRF-28800F RANDOM VIBRATION 30 MIN PER AXIS, 10-500Hz MIL-PRF-28800F CLASS 2 5 TO 55HZ RESONANCE SEARCH PER MIL-PRF-28800F CLASS 2, SINUSOIDAL EACH AXIS SHOCK 30G/AXIS, 11MS HALF SINE PULSE PER MIL-PRF-28800F CLASS 2 GENERAL INPUT PROTECTION TRANSDUCER SCREW TERMINAL INSTRUMENT CONNECTION POWER INPUT 15V ZENER PROTECTION M3 X 6MM (PAN HEAD PHILLIPS) 10/100 BASE-T INPUT CONNECTOR SCREW TERMINAL INPUT VOLTAGE DC, 18-36V DC DIMENSIONS (H x W x D) 125 mm x 238 mm x 249 mm; 4.92 x 9.05 x 9.45 WEIGHT 5.3 kg; 11 lbs. 4

THERMOCOUPLE ACCURACY Operating Temperature +15 C to +25 C -40 C to +50 C +50 C to +70 C Type E, J, K, N, and T Typical ±0.12 C ±0.22 C ±0.53 C Max ±0.20 C ±0.35 C ±0.93 C Type R, S Typical ±0.48 C ±0.88 C ±2.12 C Max ±0.80 C ±1.40 C ±3.72 C Type B Typical ±0.96 C ±1.76 C ±4.24 C Max ±1.60 C ±2.80 C ±7.44 C 1) After 1-hour warmup period and temperature stable for 1 hour after any temperature change 2) Exclusive of thermocouple, wiring, noise, common mode errors 3) Temperature variation less than 0.1 C/min 4) Typical is based on 2σ and Max is based on 4σ Specifications contained within this document are subject to change without notice. Revision 20161021. 5

ORDERING INFORMATION Model RX1032 Configuration Ruggedized 32 Channel Thermocouple Instrument BLOCK DIAGRAM RX-10XX CHASSIS MOUNTING DIMENSIONS (IN MM) VIBRATION/SHOCK ISOLATOR MOUNTING DIMENSIONS (IN MM) CONTACT +1 949-955-1894 sales@vtiinstruments.com Corporate Headquarters 2031 Main St. Irvine, CA 92614 6