Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Similar documents
Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Level Limit Switch nivotester FTL 325 P

Soliwave M FQR50 / FDR50

Technical Information Nivector FTC968, FTC968Z

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Soliwave FQR56/FDR56. Technical Information. Microwave Barrier. FQR56 emitter. FDR56 receiver

RMA42. Technical Information

Level Limit Switch nivotester FTL 370, FTL 372

SET Installation and Operating Instructions. Level switch for two sensors

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Inductive sensor slot-type SI2-K08-AP7

Remote Switching Unit nivotester FTL 320

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Temperature Input Module for Zone 1 Series 9482/32

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Temperature Transmitter itemp RTD DIN rail TMT 127

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

SALES SERVICE +358 (0)

Analog Universal Module HART for Zone 2 Series 9468/33

0 2 1 â Ó. itemp HART TMT182. Technical Information

Isolators A3/1. Vibration Transducer Supply Unit Series

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Technical Information RMA42

Temperature transmitter itemp PCP DIN rail TMT 121

Binary Output Series 9175

Level Measurement silometer FMX 570

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Digital Input Output Module for Zone 2 Series 9470/33

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

itemp HART DIN rail TMT112

Operating Instructions

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Information Barrier RB223

Digital Input Output Module for Zone 2 Series 9470/33

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolating Repeater Input Series 9163

INSTALLATION AND OPERATION MANUAL

Safety Instructions Nivotester FTC625, FTC325

Binary Output without Power Supply Series 9176

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Digital Input Output Module for Zone 1 Series 9470/32

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Preset counters, electronic

Relative and absolute pressure transmitter type 528

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

SBEx-2S BINARY SEPARATOR

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

prosonic T FMU230, FMU231

Submersible pressure sensor For oils and fuels Model LF-1

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

System Components Liquiphant M (NAMUR)/PROFIBUS-PA interface FXA 164

Process display RIA 261

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Temperature transmitter itemp RTD DIN rail TMT 127

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

QUINT-PS/ 3AC/24DC/10

Ultrasonic level meters ULM 70

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Electronic relays. Monitoring. Monitoring

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

OPTIWAVE 7300 C Supplementary instructions

Remote I/O. 74 Remote I/O. Remote I/O System

Submersible pressure sensor For water and wastewater Model LW-1

Zelio Control Measurement Relays

SINEAX B 811 Power Pack with additional Functions

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Resistance thermometer Model TR30, compact design

02/11/2015

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Field indicator for current loops with HART communication Models DIH50, DIH52

Technical Information itemp TMT180

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Installation guide 971 SmartRadar LTi

Transcription:

Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave FDR50/FQR50 microwave barrier. You can use the for level detection for any type of solids or for control and counting tasks for packaged goods. Associated apparatus for the microwave barrier with intrinsically safe circuits. Advantages at a glance High level of operational safety through line monitoring up to the sensor LED display of operating and switching state Selectable pick up and/or drop out delay of the switching output Compact housing for easy inline mounting on standard rack rails Easy wiring via pluggable terminal block connectors TI00377F/97/EN/14.16 71278977

Table of contents Function and system design... 3 Measuring principle... 3 Measuring system... 3 Limit switch signal function... 3 Function monitoring system... 3 Device combinations... 4 Input... 4 Measured variable... 4 Input signal... 4 Output... 4 Output signal... 4 Switching frequency... 4 Power supply... 5 Electrical connection... 5 Ring wiring... 5 Star wiring... 5 Supply voltage... 6 Cable specification... 6 Power consumption... 6 Installation... 7 Installation instructions... 7 Clearances... 7 Human interface... 10 Control concept... 10 Display elements... 10 Operating elements... 10 Certificates and approvals... 12 CE approval... 12 Ex approval... 12 Other standards and guidelines... 12 Ordering information... 12 Ordering information Nivotester... 12 Notes on product structure... 12 Safety instructions... 13 Zone classification... 13 Safety notes for electrical equipment for potentially explosive atmospheres... 13 Accessories... 14 Protective housing... 14 Documentation... 15 Operating instructions (KA)... 15 Tecnical informations... 15 Safety instructions... 15 Environment... 8 Ambient temperature range... 8 Storage temperature... 8 Degree of protection... 8 Electromagnetic compatibility (EMC)... 8 Mechanical construction... 9 Design, dimensions... 9 Weight... 9 Material... 9 Housing... 9 Terminals... 9 2

Function and system design Measuring principle The Nivotester monitors the Soliwave FDR50/FQR50 microwave barrier s open collector output and uses a relay (change-over gate) to provide this output for many user applications. An LED displays the switching state of the relay. Problems such as a cable breakage are also displayed. The input on the Nivotester is galvanically isolated from main power and output. It is connected to the microwave barrier via a three-wire cable (ring or star wiring), whereupon the Nivotester provides distribution (intrinsically safe circuit, DC) voltage to the microwave barrier. Measuring system Emitter Receiver Nivotester The complete measuring system for limit detection consists of: an emitter FQR50, a receiver FDR50 and an evaluator Nivotester Optical or acoustic signallers, contactors, relays, solenoids etc. may be connected to the Nivotester. Limit switch signal function The appropriate setting for the limit switch signal function (see page 9) ensures that the relay for signal output and fault is always activated (fail-safe mode) in idle state. In combination with the Soliwave FDR50/FQR50 microwave barrier the following secure modes are possible: The relay drops out when the switch point is reached (microwave barrier interrupted), a fault occurs or the distribution voltage fails. The relay drops out when the switch point is underrun (microwave barrier uninterrupted), a fault occurs or the distribution voltage fails. Function monitoring system The Nivotester is equipped with a function monitoring system for improved fail-safe operation. A fault is indicated by an LED, the fault relay falls off. In combination with the microwave barrier Soliwave FQR50/FDR50-C* and -D* resp. the Nivotester -B* and -D* resp. can recognise the following faults and use an LED to indicate them: Breakage in the power supply cable to the emitter FQR50 Microwave barrier power input (emitter FQR50 and/or receiver FDR50) too high Short-circuit (emitter FQR50, receiver FDR50 or wiring) Manual function monitoring can be carried out by pushing the test button. 3

Device combinations The following equipment combinations are possible: Nivotester -B* (ATEX II (1)G [Ex ia Ga] IIC and ATEX II (1)D [Ex ia Da] IIIC resp.) with FQR50/ FDR50-C* (ATEX II 1/2G Ex ia IIC T4 Ga/Gb and ATEX II 1/2D Ex ia IIIC T98 C Da/Db resp.) Nivotester -D* (IECEx [Ex ia Ga] IIC and IECEx [Ex ia Da] IIIC resp.) with FQR50/FDR50-D* (IECEx Ex ia IIC T4 Ga/Gb and IECEx Ex ia IIIC T98 C Da/Db resp.) The following equipment combinations are impossible: Nivotester -A* (non hazardous area) with FQR50/FDR50-C* (ATEX II 1/2G and ATEX II 1/2D resp.) Nivotester -A* (non hazardous area) with FQR50/FDR50-D* (IECEx) Nivotester -B* (ATEX II (1)G and ATEX II (1)D resp.) with FQR50/FDR50-A* (non hazardous area) Nivotester -B* (ATEX II (1)G and ATEX II (1)D resp.) with FQR50/FDR50-B*(ATEX II 1/2D) Nivotester -B* (ATEX II (1)G and ATEX II (1)D resp.) with FQR50/FDR50-D* (IECEx) Nivotester -D* (IECEx) with FQR50/FDR50-A*(non hazardous area) Nivotester -D* (IECEx) with FQR50/FDR50-B* (ATEX II 1/2D) Nivotester -D* (IECEx) with FQR50/FDR50-C* (ATEX II 1/2G and ATEX II 1/2D resp.) Input Measured variable Input signal A limit signal is generated when the microwave barrier is either interrupted or uninterrupted, depending on the type of limit signal selected. input: - Soliwave FDR50/FQR50 microwave barrier - input galvanically isolated from power supply - intrinsically safe circuit Output Output signal Relay output: - galvanically isolated from power supply - a potential-free switching contact for the limit signal - a potential-free switching contact for fault notification Breaking capacity for relay contacts: U~ max. 253 VAC I~ max. 2 A (AC) P~ max. 500 VA (cos φ 0.7) U max. 40 VDC I max. 2 A (DC) P max. 80 W Service life: min. 10 5 switching operations at max. contact load Function indicators: LEDs for - On (green) - Limit signal (yellow) - Fault (red) Switching frequency max. 2 Hz 4

Power supply Electrical connection Ring wiring When connected to the Nivotester a microwave barrier can be wired via a choice of ring or star connection. The required backup power is provided by the. Emitter FQR50 Receiver FDR50 1 2 3 1 2 3 1 2 3 6 7 8 6 7 8 1 2 1516 3 4 5 Contact circuit (terminal 3, 4, 5) and alarm output (terminal 15, 16) resp. Power supply (terminal 1, 2) Star wiring Emitter FQR50 Receiver FDR50 1 2 3 1 2 3 1 2 3 6 7 8 6 7 8 1 2 1516 3 4 5 Contact circuit (terminal 3, 4, 5) and alarm output (terminal 15, 16) resp. Power supply (terminal 1, 2) 5

Supply voltage AC voltage model - Voltage range: 85.. 253 VAC, 50/60 Hz DC voltage model - Voltage range: 20.. 30 VAC / 20.. 60 VDC - Reverse voltage protection Internally there is a micro-fuse built into the supply voltage circuit so that only one fuse for short circuits in the feed line to the must be upstream. Cable specification Power consumption -B* with FQR50/FDR50-C* and -D* with FQR50/FDR50-D* resp.: Off-the-shelf installation cable, 3-conductor, non-shielded Resistance: 15 Ω/km R' 150 Ω/km Inductance: 0.4 mh/km L' 1 mh/km Capacitance: 45 nf/km C' 200 nf/km Length of spurs max. 1000 m (IIC) and 5000 m (IIB) respectively AC voltage model: 6,9 VA DC voltage model: 1,85 W 6

Installation Installation instructions The Nivotester is mounted upright on a DIN rail (TS 35 as per EN 50022). A protective case (IP 66, see accessories) is available for external installation. min. IP 55 100 mm = 3.94 in Din rail EN 50022-35x7.5 / EN 50022-35x15 Clearances -20 C... +40 C / -4 F... +104 F -20 C... +60 C / -4 F... +140 F -20 C... +50 C / -4 F... +122 F 7

Environment Ambient temperature range - 20 C... + 60 C (if installed individually) - 20 C... + 50 C (if installed in-line without clearance spaces) - 20 C... + 40 C (if installed in protective case) Storage temperature Degree of protection IP 20 Electromagnetic compatibility (EMC) Note! If possible mount devices so that they are not subjected to direct sunlight. This applies especially to use in warmer climates. - 20 C... + 85 C (preferably at + 20 C) Interference Emission to EN 61326, Electrical Equipment Class B Interference Immunity to EN 61326, Appendix A (Industrial) 8

Mechanical construction Design, dimensions DIN rail EN 50022-35x7.5 / EN 50022-35x15 Weight 0.3 kg Material Housing: - Polycarbonat, Polyamid PA6 - Color (main part): Light grey, RAL 7035 Housing Housing: In-line case (Minipac shape) made of plastic Terminals 6 78 ---- X2 Refer to the nameplate! 6 78 ---- X1 N L1 L- N L+ L1 F 1 215 3 45 16 ---- X1 ---- X2 max. 1.5 mm 2 (max. AWG 16) The four plug terminals are a part of the device. 9

Human interface Control concept Display elements Operating elements Onsite adjustments using switches and potentiometers behind the hinged face plate. Green LED: operational state Yellow LED: switching state Red LED: fault Limit switch signal function Test button Fault notification LED row YE - yellow (switch state) RD - red (fault) GN - green (operation) Limit switch signal function: - Switches the limit switch relay on or off when the microwave barrier is either interrupted or uninterrupted, depending on the type of limit signal selected. - Optical indication of switching state via yellow LED Fault notification: - When activated, switches on the fault relay when a fault occurs - Optical indication of a fault via red LED Test button: - Simulation of a fault when fault notification switched on - Simulation of a limit signal when fault notification is switched off (for uninterrupted microwave barrier) 10

Switch delay (pick up delay) t(t) = 0.5..20 s m T T t(s) = 0.5..20 s n S S Switch delay (drop out delay) Switch delay (pick up delay): - When switch delay activated limit switch relay switches on pick up delay after time t(t) - Adjustable time: t(t) = 0.5.. 20 s Switch delay (drop out delay): - When switch delay activated limit switch relay switches off drop out delay after time t(s) - Adjustable time: t(s) = 0.5.. 20 s Note: The switching frequency (maximum 2 Hz) is given by the microwave barrier Soliwave FDR50/FQR50. You can find detailed information on the different setting options in the KA00205F/97/A6 operating instructions. 11

Certificates and approvals CE approval Ex approval Other standards and guidelines The Nivotester fulfils the legal requirements of the EC directives. The manufacturer confirms the successful examination of the equipment by using the CE mark. See "Ordering information" EN 60529 Degrees of protection through housing (IP code) EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use EN 61326-X EMC product family standard for electrical equipment for measurement, control and laboratory use Ordering information Ordering information Nivotester 10 Approval: B ATEX II (1)G [Ex ia Ga] IIC ATEX II (1)D [Ex ia Da] IIIC D IECEx [Ex ia Ga] IIC IECEx [Ex ia Da] IIIC Y Special version, to be specified 20 Model: 1 DIN rail mounting, b = 45 mm 9 Special version, to be specified 30 Power supply: A 85-253 VAC, 50/60 Hz E 20-60 VDC 20-30 VAC, 50/60 Hz Y Special version, to be specified 40 Output: 1 1x level SPDT + 1x alarm/level SPST 9 Special version, to be specified - Notes on product structure The following equipment combinations are possible: Nivotester -B* (ATEX II (1)G [Ex ia Ga] IIC and ATEX II (1)D [Ex ia Da] IIIC resp.) with FQR50/ FDR50-C* (ATEX II 1/2G Ex ia IIC T4 Ga/Gb and ATEX II 1/2D Ex ia IIIC T98 C Da/Db resp.) Nivotester -D* (IECEx [Ex ia Ga] IIC and IECEx [Ex ia Da] IIIC resp.) with FQR50/FDR50-D* (IECEx Ex ia IIC T4 Ga/Gb and IECEx Ex ia IIIC T98 C Da/Db resp.) 12

Safety instructions Zone classification Emitter FQR50-C* FQR50-D* Zone 1 / Zone 21 Zone 0 / Zone 20 Receiver FDR50-C* FDR50-D* Nivotester -B* -D* Safety notes for electrical equipment for potentially explosive atmospheres The following equipment combinations are allowed to operate in explosive area: - -B* with FQR50/FDR50-C* (see Safety Instructions XA00219F/97/A3) - -D* with FQR50/FDR50-D* (see Safety Instructions XA00484F/97/EN) Install the device according to the manufacturer's instructions and any other valid standards and regulations (e.g. EN/IEC 60079-14). Incorrect use of the device poses a danger. The device may be installed, hooked up and put into operation only by qualified and authorized persons with special attention paid to - the operating manual, - the relevant standards and - legal rules and regulations. The Nivotester can and may be serviced by the manufacturer only. 13

Accessories Protective housing A protective housing for field installation of top-hat rail devices e. g. Nivotester is available. In this housing there is space for several top-hat rail devices (to a maximum installation width of 145 mm). Technical data - Order code: 52010132 - Protection type (according to EN 60529): IP 66 - Lower housing section: fibre-glass reinforced polycarbonate, grey - Upper housing section: polycarbonate, transparent - Seal: PU seal - Top-hat rail (EN 50022): galvanized - Cable entries: 5 pieces M20x1.5 14

Documentation Operating instructions (KA) Nivotester KA00205F/97/A6 Soliwave FQR50/FDR50 KA00206F/97/A6 Tecnical informations Safety instructions Soliwave FQR50/FDR50 TI00378F/97/EN Soliwave FQR50/FDR50-C* with the Nivotester -B* XA00219F/97/A3 Soliwave FQR50/FDR50-D* with the Nivotester -D* XA00484F/97/EN 15

Subject to modification Instruments International Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00377F/97/EN/14.16 16 71278977 InDesign 6.0.6