Exercise 7 AC voltage measurements peak responding detectors

Similar documents
Exercise 6 AC voltage measurements average responding voltmeters

Power supply circuits

Laboratory 2 (drawn from lab text by Alciatore)

Physics 310 Lab 4 Transformers, Diodes, & Power Supplies

Electronic Circuits I Laboratory 03 Rectifiers

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

Experiment 1.A. Working with Lab Equipment. ECEN 2270 Electronics Design Laboratory 1

Power supply circuits

Electronics II. 3. measurement : Tuned circuits

EXPERIMENT 4 LIMITER AND CLAMPER CIRCUITS

Experiment #2 Half Wave Rectifier

HAMEG Modular System Series 8000

Electronic Instrumentation & Automation. ET-7th semester. By : Rahul Sharma ET & TC Deptt. RCET, Bhilai

Experiment No. 2 Half Wave Rectifier using RC-Triggering

LAB 1: Familiarity with Laboratory Equipment (_/10)

ES736 True RMS-to-DC Converters

AC Theory and Electronics

EDEXCEL NATIONALS UNIT 5 - ELECTRICAL AND ELECTRONIC PRINCIPLES. ASSIGNMENT No.1 - RESISTOR NETWORKS

EE 330 Laboratory 8 Discrete Semiconductor Amplifiers

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

transformer rectifiers

Lab 2: Linear and Nonlinear Circuit Elements and Networks

LED level meter driver, 12-point, linear scale, dot or bar display

DEPARTMENT OF ELECTRICAL ENGINEERING LAB WORK EE301 ELECTRONIC CIRCUITS

PHY203: General Physics III Lab page 1 of 5 PCC-Cascade. Lab: AC Circuits

Electronics 1 Lab (CME 2410)

EE 330 Laboratory 8 Discrete Semiconductor Amplifiers

Operational Amplifiers: Part II

Laboratory 2. Lab 2. Instrument Familiarization and Basic Electrical Relations. Required Components: 2 1k resistors 2 1M resistors 1 2k resistor

Diodes This week, we look at switching diodes, LEDs, and diode rectification. Be sure to bring a flash drive for recording oscilloscope traces.

ECE 231 Laboratory Exercise 3 Oscilloscope/Function-Generator Operation ECE 231 Laboratory Exercise 3 Oscilloscope/Function Generator Operation

EE431 Lab 1 Operational Amplifiers

Single-Phase Grid-Tied Inverter (PWM Rectifier/Inverter)

Electronics I. laboratory measurement guide

EE 221 L CIRCUIT II. by Ming Zhu

DEPARTMENT OF ELECTRICAL ENGINEERING LAB WORK EE301 ELECTRONIC CIRCUITS

BME/ISE 3512 Bioelectronics. Laboratory Five - Operational Amplifiers

Electronics I. laboratory measurement guide Andras Meszaros, Mark Horvath

LABORATORY MODULE. Analog Electronics. Semester 2 (2005/2006)

EXPERIMENT 5 : DIODES AND RECTIFICATION

A Practical Exercise Name: Section:

Table of Contents...2. About the Tutorial...6. Audience...6. Prerequisites...6. Copyright & Disclaimer EMI INTRODUCTION Voltmeter...

Lab #2: Electrical Measurements II AC Circuits and Capacitors, Inductors, Oscillators and Filters

ECE ECE285. Electric Circuit Analysis I. Spring Nathalia Peixoto. Rev.2.0: Rev Electric Circuits I

2 AC and RMS. To pass this lab you must solve tasks 1-2. Tasks 3 and 4 are included in the grading of the course.

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

BME 3512 Bioelectronics Laboratory Five - Operational Amplifiers

EXPERIMENT 5 : THE DIODE

EE283 Electrical Measurement Laboratory Laboratory Exercise #7: Digital Counter

EXPERIMENT 5 : THE DIODE

UNIVERSITY OF TECHNOLOGY, JAMAICA SCHOOL OF ENGENEERING. Electrical Engineering Science. Laboratory Manual

EE 2274 DIODE OR GATE & CLIPPING CIRCUIT

ECE Electronics Circuits and Electronics Devices Laboratory. Gregg Chapman

Experiment 2: Transients and Oscillations in RLC Circuits

Experiment 6: Amplitude Modulation, Modulators, and Demodulators Fall 2009

EXPERIMENT 5 : THE DIODE

EE 2212 EXPERIMENT 3 3 October 2013 Diode I D -V D Measurements and Half Wave and Full Wave Bridge Rectifiers PURPOSE

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Wave Measurement & Ohm s Law

Experiment No. 1 Half Wave Rectifier using R-Triggering

INTRODUCTION TO ENGINEERING AND LABORATORY EXPERIENCE Spring, 2015

Half-wave Rectifier AC Meters

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

Group: Names: Resistor Band Colors Measured Value ( ) R 1 : 1k R 2 : 1k R 3 : 2k R 4 : 1M R 5 : 1M

Exercise 2: Demodulation (Quadrature Detector)

Experiment 7: Frequency Modulation and Phase Locked Loops

Sonoma State University Department of Engineering Science Spring 2017

Electronic Circuits Laboratory EE462G Lab #3. Diodes, Transfer Characteristics, and Clipping Circuits

Make Better AC RMS Measurements with your Digital Multimeter APPLICATION NOTE

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

Fig. 1. NI Elvis System

ECE 6416 Low-Noise Electronics Orientation Experiment

Exp. 1 USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS, PART I

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

Precision Rectifier Circuits

Electric Circuit Fall 2017 Lab3 LABORATORY 3. Diode. Guide

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Instrument Usage in Circuits Lab

Power Supplies. Linear Regulated Supplies Switched Regulated Supplies Batteries

Exercise 9: inductor-resistor-capacitor (LRC) circuits

DIY Function Generator XR2206

Electrical and Electronic Principles in Engineering

Contents. 1 Block Diagram. 2 Specifications. 3 Unipolar vs. Bipolar Interconnections. 4 Inexpensive Bipolar Power Supply Alternative.

Prepare for this experiment!

Exercise 3: Voltage in a Series Resistive Circuit

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

EE 210: CIRCUITS AND DEVICES

Başkent University Department of Electrical and Electronics Engineering EEM 214 Electronics I Experiment 2. Diode Rectifier Circuits

Laboratory Activities Handbook

2. SINGLE STAGE BIPOLAR JUNCTION TRANSISTOR (BJT) AMPLIFIERS

1) Consider the circuit shown in figure below. Compute the output waveform for an input of 5kHz

Brown University PHYS 0060 Physics Department LAB B Circuits with Resistors and Diodes

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

EE320L Electronics I. Laboratory. Laboratory Exercise #4. Diode Rectifiers and Power Supply Circuits. Angsuman Roy

SENSOR AND MEASUREMENT EXPERIMENTS

POLYTECHNIC UNIVERSITY Electrical Engineering Department. EE SOPHOMORE LABORATORY Experiment 3 The Oscilloscope

1.0 Introduction to VirtualBench

Experiment 9 : Pulse Width Modulation

Experiment No.5 Single-Phase half wave Voltage Multiplier

Step Response of RC Circuits

Transcription:

Exercise 7 AC voltage measurements peak responding detectors 1. Aim of the exercise The aim of the exercise is to familiarize students with the AC voltage measurements by means of peak responding detectors. 2. Main topics Issues with AC voltage characterization Basic principles of peak responding detectors (AC and DC coupled). Design of peak responding AC voltmeters. 3. Gained skills Oscilloscope observation of the input and output signals of AC and DC coupled peak responding detectors, Designing peak-responding AC voltmeters, Characterization of peak-responding AC voltmeters. 4. Brief introduction AC signal parameters - RMS (Root Mean Square) U voltage which is equal to the value of the direct current that would produce the same power dissipation in a resistive load. Can be expressed as: U = 1 T t 0 t 0 +T [u(t)]2 dt - Rectified average voltage a mean of the absolute value of the signal voltage: U AV = 1 T t 0 t 0 +T u(t) dt - Peak value: U M = max <t 0,t 0 +T> u(t) - Peak to peak value max <t 0,t 0 +T> min U PP = u(t) u(t) <t 0,t 0 +T> Based on these values several useful factors can be defined: - Form factor: k f = U U AV

- Crest factor: For sine (harmonic) signal: k c = U M U k f = π 2 2 1,11 k c = 2 Peak responding detectors The electric diagrams of peak responding detectors are presented in figure 1. Figure 1. Peak responding detectors a) DC coupled, b) AC coupled. The basic principle of both types of detectors is that a diode allows the capacitor to be charged, but prevents its discharging (as a diode is component which allows only one current direction). In terms of their topology the AC and DC coupled detectors are the same, their difference is only due to the different set-up of the output (from the capacitor in the DC coupled and from the diode in the AC coupled). To comprehend the operation of the detectors it is useful to bear in mind that due the Kirchhoff s Voltage Law, the directed sum of the electrical voltages around any closed network is zero and it applies each single moment. The phenomena are illustrated in figure 2.

Figure 2 Principle of operation of peak responding detectors. Besides of the voltage, an important parameter of the peak responding detector is its low limiting frequency. In this task it is assumed as: F d10=10/(r C) Laboratory module description Module P01 (Figure 3) makes it possible to investigate a peak responding detectors in both AC and DC coupled set-ups. Diode and capacitor should be connected in an arbitrary configuration in the Przetwornik block of the module. When connecting a diode one needs to take care on their polarization (connection direction). In this purpose, taking a look at the figure 4 is advised. Figure 3. P01 Module

Anode Katode Figure 4. A diode

5. Measurements and tasks Task 1. Investigation of the performance of DC coupled peak responding detector Using P01 build a DC coupled peak responding detector. Use the capacitor provided by the supervisor.! a) Set the sine input signal of Vpp of 5 V and frequency of 1 khz. Connect this signal to the DC coupled detector input. For both diode polarizations observe both input and output signals on the oscilloscope. Use the same scale and the ground level for both the oscilloscope channels. Put the oscillograms in the report and comment on them. b) For a single diode direction investigate the influence of the loading resistance on the shape of the output signal. In order to this connect the decade resistors to V connectors and shortcut Rd connectors. Put a few (distinctive) oscillograms in the report. c) Add the DC offset to the input signal and repeat the observations from point a). Based on the obtained results discuss the observation. Address the differences between the obtained oscillograms and theoretical predictions and explain them. Task 2. Investigation of the performance of AC coupled peak responding detector! Set the sine input signal of Vpp of 5 V and frequency of 1 khz. Connect this signal to the AC coupled detector input. For both diode polarizations observe both input and output signals on the oscilloscope. Use the same scale and the ground level for both the oscilloscope channels. Put the oscillograms in the report and comment on them. Investigate the influence of adding a DC component to the input signal and comment on that. Based on the obtained results discuss the observation. Address the differences between the obtained oscillograms and theoretical predictions and explain them. Task 3. Design of a peak responding AC voltmeter Design a peak responding AC voltmeter of the voltage range UZ and the low limiting frequency fd10 (which will be provided by supervisor) calibrated to measure the RMS value of sine waveform. Use LM-3 voltmeter of χ=1kω/v and the voltage range UZ0. Consider a diode as an ideal one. Calculate the resistance of Rd resistor (which should be connected in series with the LM-3 meter) and capacity of the C capacitor. Put the design data, voltmeter scheme together with formulas and calculations in the report.

Task 4. Characterization of the designed peak responding AC voltmeter a) Based on your design in task 3 build a peak responding AC voltmeter. Use 34450A AC voltmeter as a reference meter. Set the sine signal voltage from the generator to obtain UFS of the designed voltmeter on the calibrated meter. Set the frequency 3-5 times higher than fd10. Connect the signal to the meter you constructed and adjust Rd to have the full deflection. Put a new Rd value into the report with the frequency you applied. How the adjustment influenced the fd10? Calculate the new low limiting frequency. b) Measure the designed voltmeter s deflection vs input voltage characteristics =f(u) for the full range. In this purpose keep changing the input voltage from 0 to UFS with 0.5 V step and measure the input (reference) voltage (U) with the use of multimeter. is the designed voltmeter deflection in units. Draw the obtained dependency and compare it with the theoretical one (most suitably on the same drawing). c) Set the RMS of the input voltage for UFS/2. Measure the output RMS of the designed voltmeter for a number of frequencies between 0.2 and 2 fd10. Based on the results draw a frequency characteristic of your meter.

Control questions 1. Why do we connect a resistor in series with LM-3 meter in the peak responding AC voltmeter? 2. What is the role of the diode in peak responding detectors? 3. What is the role of the capacitor in peak responding detectors? 4. What is the frequency impact on the reading of peak responding AC voltmeters? 5. What is the loading resistance impact on the reading of peak responding AC voltmeters? 6. A DC coupled peak responding detector is supplied with sine signal of Vpp = 10 V and the DC component of a) -2 V, b) 2 V. Draw the output signals for each diode polarization. Consider the diode characteristic ideal and open circuit at the output. 7. A DC coupled peak responding AC voltmeter is supplied with sine signal: u(t)=5+10sinωt [V]. What will be the reading if the meter is calibrated for the RMS value? What would be the reading of a DC voltmeter for this signal? 8. An AC coupled peak responding AC voltmeter is supplied with sine signal: u(t)=5+10sinωt [V]. What will be the reading if the meter is calibrated for the RMS value? What would be the reading of a DC voltmeter for this signal? 9. Draw the output signals for AC and DC coupled peak responding detectors if they are supplied with a signal: u(t)=5+10sinωt [V]. 10. What resistance should be connected in series with a magnetoelectric meter of the internal resistance of 10 kω and the voltage range of 10 V to obtain an AC voltmeter calibrated to measure the RMS of the sine signal on the same voltage range. For the voltmeter a peak responding detector was used. 11. What is the influence of the duty cycle of the rectangular waveform on the indication of peak responding detectors? Draw sample signals for a DC coupled detector. 12. What problems can you expect with the measurements of low-voltage signals with the use of peak responding detectors?