Buck-Boost Transformers

Similar documents
Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

BUCK-BOOST TRANSFORMERS

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

BUCK-BOOST TRANSFORMERS

Steps for Selecting the Proper Transformer

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

HPS Universal BUCK-BOOST TRANSFORMERS

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

Product Data Bulletin

T S 15KVA 1PH 240/480 Transformer

Drive Isolation Transformers

Warehouse Stock Transformers

Non-Linear Load Transformers

Full Line Product Catalog

Full Line Product Catalog

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Jefferson Electric Inc Product Catalog JE901

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Acme Electric Full Line Product Catalog

Transformer Questions & Answers

2.1. Product Description

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

ULTRA-K Series 600K - he

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Power-Sure 700. Technical Data TD158001EN. Contents

General Description & Features Selection Charts Definition of Terms... 42

Transformer Questions & Answers

PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

Load Isolation Transformers

Dry-Type Transformers

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

Power Processor - Series 700F 10KVA to 150KVA

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

Straight Isolation - Hard Wired (169 Series)

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

Power Conditioners product guide

DONGAN ELECTRIC MANUFACTURING CO.

Technical Data and Specifications. Core and Coil Assemblies

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Low Voltage Transformers. Selection Guide

What is a Transformer?

Challenges of Parallel Operations

TECHNICAL INFORMATION

TRANSFORMER OPERATION

Line Frequency Transformer

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Amveco Toroidal Solutions. Acme Electric s class leading toroidal magnetics is the perfect solution for the most challenging applications.

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Established 1942 Quality Service Competitive Prices Single Phase Transformers Three Phase Transformers Open frame or Enclosed Smoothing Chokes

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

TOSHIBA International Corp

Phoenix DX Clean Power (18 Pulse) AC Drive

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Strategies for design 600V large modular UPS for critical power applications

Energy Efficient Distribution Transformers

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

Single Phase Soft Starters

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Three Winding Transformer.

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Single-Phase Transformation Review

Transformers & Inductive Components

S11 Adjustable Speed Drive Engineering Specification

DISCONNECT SWITCHES. UL Listed CSA Certified

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

3Ø Short-Circuit Calculations

Section 2 Outdoor Voltage Transformers

Isolation Transformer Series

Regional Technical Seminar

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

SECTION TRANSFORMERS

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Transcription:

Buck-Boost Transformers Buck Boost transformers are the ideal solution anytime a line voltage change in the 5-15% range is required in single phase or three phase applications.

Proper voltage is critical ith nearly two-thirds of all electrical loads being A.C. motor loads, maintenance of the proper voltage to that motor is very important. If the supply line voltage is not maintained, motor winding current is increased causing reduced motor torque and escalating motor temperature, all of which results in the rapid loss of insulation life expectancy. Anytime you have a lower than standard voltage, equipment damage and failure can result. Buck-boost transformers are an economical way to correct this potentially very serious problem. Anytime a line voltage change in the 5-20% range is required, a buck-boost transformer should be considered as your first line of defense. here are buck-boost transformers used? A typical buck-boost application is 120 volts in, 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage transformer is field connected as an autotransformer. Buck-boost transformers provide tremendous capabilities and flexibility in kva sizes and input/output voltage combinations. Basically you get 75 different transformers... all in one convenient package. Other buck-boost applications are, where (A) low supply voltage exists because equipment is installed at the end of a bus system; (B) the supply system is operating at or over its design capacity; and (C) where overall consumer demands may be so high the utility cuts back the supply voltage to the consumer causing a brownout. hy use buck-boost instead of another type transformer? Take a look at the advantages and disadvantages of using a buck-boost transformer (autotransformer) compared to a standard isolation transformer of the proper size and voltage combination. Advantages More efficient Smaller & lighter 5-10 times increase in kva isadvantages No circuit isolation Cannot create a neutral Application voltages and kva don t match the nameplate voltages and kva Versatile, many applications Lower cost Can buck-boost transformers be used on three-phase systems as well as single phase systems? Yes. A single unit is used to buck or boost single phase voltage two or three units are used to buck or boost three phase voltage. The number of units to be used in a three -phase installation depends on the number of wires in the supply line. If the three-phase supply is 4 wire Y, use three buck-boost transformers. If the 3-phase supply is 3 wire Y (neutral not available), use two buck-boost transformers. Alternatively, Acme Electric s NE 3 Phase Auto Buck Boost Transformers remove the need for multiple separate units and provide the same great electrical advantages standard Buck Boost Transformers offer in one simple and convenient package. T211688 T111683 For help selecting the correct Buck-Boost Transformer, check out our catalog or our selection tool, both available on our website. 2

Single Phase,.05 to 10.0 kva Encapsulated Features n UL listed, CSA certified and UL 3R enclosure, meets or exceeds all listing criteria, including NEMA, ANSI, and OSA standards n Flexibility, can be used in single phase and three pase configurations n Reduce (buck) or raise (boost) line voltage from 5-20% n All copper lead wire terminations n Long Life, 80 C rise up to 0.15 kva, and 115 C rise above 0.25 kva n Can be used in Three Phase applications Three Phase, 6.0 to 45 kva Encapsulated Features n UL listed, CSA certified and UL 3R enclosure, meets or exceeds all listing criteria, including NEMA, ANSI, and OSA standards n One unit, instead of multiple for 3 phase applications n Time and installation cost savings as units come pre-wired from the factory n Smaller footprint compared to using three individual single phase units n Long Life, UL class 180 C insulation system, 115 C rise 3

SPECIFICATIONS 1 - SINGLE PASE 120 X 240 PRIMARY VOLTS 12/24 SECONARY VOLTS 60 z Insulating Transformer Rating Secondary Maximum Current Output 12 V 24 V eight epth eight imensional rawings T181047 0.05 kva 4.16 2.08 6.41 (16.3) 3.14 (8.0) 3.05 (7.7) 4 (1.8) A T181048 0.10 kva 8.32 4.16 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 5 (2.3) A T181049 0.15 kva 12.52 6.25 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 7 (3.2) A T181050 0.25 kva 20.80 10.40 8.68 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) B T181051 0.50 kva 41.60 20.80 9.06 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) B T181052 0.75 kva 62.50 31.25 9.68 (24.6) 4.75 (12.1) 4.51 (11.5) 19 (8.6) B T111683 1.00 kva 83.20 41.60 10.50 (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) B T111684 1.50 kva 125.00 62.50 11.62 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) B T111685 2.00 kva 166.00 83.20 13.00 (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) B T111686 3.00 kva 250.00 125.00 11.50 (29.2) 10.31 (26.2) 7.13 (18.1) 55 (24.9) C T111687 5.00 kva 416.60 208.00 14.38 (36.5) 10.31 (26.2) 7.13 (18.1) 75 (34.0) C T211688 7.50 kva 625.00 312.50 20.81 (52.9) 11.12 (28.2) 10.84 (27.5) 125 (56.7) T211689 10.00 kva 833.00 416.60 20.81 (52.9) 11.75 (29.8) 11.59 (29.4) 160 (72.6) 120 X 240 PRIMARY VOLTS 16/32 SECONARY VOLTS 60 z Insulating Transformer Rating Secondary Maximum Current Output 16 V 32 V eight epth eight imensional rawings T181054 0.05 kva 3.12 1.56 6.41 (16.3) 3.14 (8.0) 3.05 (7.7) 4 (1.8) A T181055 0.10 kva 6.25 3.12 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 5 (2.3) A T181056 0.15 kva 9.38 4.69 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 7 (3.2) A T181057 0.25 kva 15.60 7.80 8.68 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) B T181058 0.50 kva 31.20 15.60 9.06 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) B T181059 0.75 kva 46.90 23.40 9.68 (24.6) 4.75 (12.1) 4.51 (11.5) 19 (8.6) B T113073 1.00 kva 62.50 31.20 10.50 (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) B T113074 1.50 kva 93.70 46.90 11.62 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) B T113075 2.00 kva 125.00 62.50 13.00 (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) B T113076 3.00 kva 187.50 93.80 11.50 (29.2) 10.31 (26.2) 7.13 (18.1) 55 (24.9) C T113077 5.00 kva 312.00 156.00 14.38 (36.5) 10.31 (26.2) 7.13 (18.1) 75 (34.0) C T213078 7.50 kva 468.00 234.00 20.81 (52.9) 11.12 (28.2) 10.84 (27.5) 125 (56.7) T213079 10.00 kva 625.00 312.00 20.81 (52.9) 11.75 (29.8) 10.84 (27.5) 160 (72.6) 1 All units have ground studs for use with non-metallic conduit. All sizes of 0.75 kva and less are suitable for 50/60 ertz. Additional field wiring box may be required when using units as autotransformers. 240 X 480 PRIMARY VOLTS 24/48 SECONARY VOLTS 60 z Insulating Transformer Rating Secondary Maximum Current Output 24 V 48 V eight epth eight imensional rawings T181061 0.05 kva 2.08 1.04 6.41 (16.3) 3.14 (8.0) 3.05 (7.7) 4 (1.8) A T181062 0.10 kva 4.16 2.08 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 5 (2.3) A T181063 0.15 kva 6.24 3.12 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 7 (3.2) A T181064 0.25 kva 10.40 5.20 8.68 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) B T181065 0.50 kva 20.80 10.40 9.06 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) B T181066 0.75 kva 31.20 15.60 9.68 (24.6) 4.75 (12.1) 4.51 (11.5) 19 (8.6) B T137920 1.00 kva 41.60 20.80 10.50 (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) B T137921 1.50 kva 62.40 31.20 11.62 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) B T137922 2.00 kva 83.20 41.60 13.00 (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) B T137923 3.00 kva 125.00 62.50 11.50 (29.2) 10.31 (26.2) 7.13 (18.1) 55 (24.9) C T137924 5.00 kva 208.00 104.00 14.38 (36.5) 10.31 (26.2) 7.13 (18.1) 75 (34.0) C T243570 7.50 kva 312.00 156.00 20.81 (52.9) 11.12 (28.2) 10.84 (27.5) 135 (61.2) T243571 10.00 kva 416.00 208.00 20.81 (52.9) 11.75 (29.8) 11.59 (29.4) 160 (72.6) 4

277 PRIMARY VOLTS 12/24 SECONARY VOLTS 60 z Insulating Transformer Rating Secondary Maximum Current Output 12 V 24 V eight epth eight imensional rawings T1100V0370BC 0.10 kva 8.33 4.16 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 5 (2.3) A T1150V0370BC 0.15 kva 12.5 6.24 7.16 (18.2) 3.89 (9.9) 3.67 (9.3) 7 (3.2) A T1250V0370BC 0.25 kva 20.83 10.49 8.68 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) B T1500V0370BC 0.50 kva 41.67 20.83 9.06 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (6.8) B T1001K0370BC 1.00 kva 83.33 41.67 10.50 (26.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) B T1005K0370BC 1.50 kva 125.0 62.5 11.62 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.6) B Units Rated 277 V Input: 12/24 V Output Input Output Connection iagram 277 12 M 277 24 N Units Rated 120 x 240 V Input: 12/24 V Output Input Output Connection iagram 120 12 K 120 24 L 240 12 M 240 24 N Units Rated 240 x 480 V Input: 24/48 V Output Input Output Connection iagram Units Rated 120 x 240 V Input: 16/32 V Output Input Output Connection iagram 120 16 K 120 32 L 240 16 M 240 32 N Number of Leads per Termination 1 2 3 4 X1 X2 X3 X4 T213078 1 1 1 1 2 2 2 2 T213079 1 1 1 1 2 2 2 2 T243571 1 1 1 1 2 2 2 2 T211688 1 1 1 1 2 2 2 2 T211689 1 1 1 1 2 2 2 2 240 24 K 240 48 L 480 24 M 480 48 N IRING IAGRAMS K L M N 4 3 4 3 2 1 2 1 4 3 2 1 4 3 2 1 X1 X2 X3 X4 X1 X2 X3 X4 X1 X2 X3 X4 X1 X2 X3 X4 5

TREE PASE BUCK-BOOST Acme Electric s NE 3 Phase Auto Buck Boost Transformers are the best economical solutions available for three phase applications, requiring only one transformer and reducing the overall footprint. Additionally, the transformers are assembled and prewired at the factory, a considerable time and installation cost savings. Acme Electric s NE 3 Phase Auto Buck Boost Transformers are UL Listed with a 10 year warranty and are currently being offered in Type 3R enclosures. 240 PRIMARY VOLTS 208 SECONARY VOLTS KVA eight epth eight imensional rawing 3 A3003K0310B 15.19(38.6) 13.50(34.3) 10.84(27.5) 120(54.0) 6 A3006K0310B 15.19(38.6) 13.50(34.3) 10.84(27.5) 120(54.0) 9 A3009K0310B 15.19(38.6) 13.50(34.3) 10.84(27.5) 130(58.5) 15 A3015K0310B 15.19(38.6) 13.50(34.3) 10.84(27.5) 130(58.5) 30 A3030K0310B 18.86(47.9) 20.30(51.6) 9.03(22.9) 250(112.5) I 45 A3045K0310B 18.86(47.9) 20.30(51.6) 9.03(22.9) 270(121.5) I 75 A3075K0310B 24.81(63.0) 27.13(68.9) 11.14(28.3) 400(180.0) I 112.5 A3112K0310B 24.81(63.0) 27.13(68.9) 11.14(28.3) 600(270.0) I 150 A3150K0310B 24.81(63.0) 27.13(68.9) 11.14(28.3) 650(292.5) I CONNECTION IAGRAM BUCK-BOOST IMENSIONAL RAINGS esign A esign B esign C esign esign I 6

NOTES 7

800.334.5214 hubbell-acmeelectric.com ubbell Canada Inc. 905-839-1138 ubbell de Mexico, S.A. de C.V. 52-55-9151-9999 ACM_BRO_028_1016