SIN 57 Issue 2.4 May 2018

Similar documents
KiloStream Data Sheet

Suppliers' Information Note. Microconnect Distributed Antennas. Service & Interface Description

Suppliers' Information Note. BT Metallic Path Facility. Interface Description

) ,4)0,%8 $4%$#% ).4%2&!#% &/2 53%2 #,!33%3 05",)# $!4!.%47/2+3 ).4%2&!#%3. )454 Recommendation 8 INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK

INTERNATIONAL TELECOMMUNICATION UNION

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

SIN 355 Issue 1.8 January 2016

Superseded by a more recent version INTERNATIONAL TELECOMMUNICATION UNION

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

) #(2/./53 $!4! 42!.3-)33)/.!4! $!4! 3)'.!,,).' 2!4% ()'(%2 4(!. KBITS 53).' K(Z '2/50 "!.$ #)2#5)43

Suppliers' Information Note. BT Public Switched Telephone Network (PSTN): Technical Characteristics Of The Multi-Line Analogue Line Interface

EUROPEAN pr ETS TELECOMMUNICATION February 1996 STANDARD

BASIC PARAMETERS FOR THE MEASUREMENT OF ERROR PERFORMANCE AT BIT RATES BELOW THE PRIMARY RATE

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

Suppliers' Information Note. BT Public Switched Telephone Network (PSTN): Technical Characteristics Of The Single Analogue Line Interface

INTERNATIONAL TELECOMMUNICATION UNION. SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voice-band modems

Siemens ST950 & ST900 Statement of Compliance Against TR 2513 Issue A, September 2005 Performance Specification for Wig Wag Signal Control Equipment

ANALOG AND DIGITAL PHYSICAL INTERFACES

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

TECHNICAL TBR 2 BASIS for January 1997 REGULATION

INTERNATIONAL TELECOMMUNICATION UNION

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

This Special Provision covers the requirements for the installation and testing of fibre optic modems (FOM).

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

RECOMMENDATION ITU-R BT.1302 *

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

USER'S MANUAL. Model : K

Installation and Quick Reference Guide. Disclaimer and warranty 2. Contents of this box 2. Brief background to AIS 3.

Exercise 3. Differential QAM (DQAM) EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Review of phase ambiguity

Final draft ETSI EN V1.1.1 ( )

M9606. FSK Modem. 5C Communications Inc.

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

8450 Series CellGuard TM Power / VSWR Monitors

EMC Evaluation of Comtrend Ethernet Powerline Adaptors

Interface converter G kbit/sec

Trillium US Inc. E350 Temperature Monitor User s Manual Rev A / February 2016

RFL-SHFI-M Module. C37.94 Short Haul Fibre Interface For Milegate. User Manual

ROM/UDF CPU I/O I/O I/O RAM

1995 Metric CSJ , etc. SPECIAL SPECIFICATION ITEM D-I Muldem (Drop/Insert Multiplexor/Demultiplexor)

Broadband Step-Up Transformer. User Manual

RFL-SHFI and SHFI-2 Module. C37.94 Short Haul Fibre Interface for UMUX. User Manual

JOINT STOCK COMPANY. MULTICHANNEL RECEIVER RI-4010M (version RM ) User guide

Distribution transformers Part 2 Ground mounted transformers not closecoupled

INTERNATIONAL TELECOMMUNICATION UNION

)454 ' ).4%27/2+).' "%47%%..%47/2+3 "!3%$ /. $)&&%2%.4 $)')4!, ()%2!2#()%3!.$ 30%%#( %.#/$).',!73 $)')4!,.%47/2+3. )454 Recommendation '

SPECIAL SPECIFICATION 1806 Spread Spectrum Wireless Modem

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

ETSI EN V1.1.1 ( )

AMU-214 Auxiliary Monitor Unit Operations Manual

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

MDW-45 Converter RS RS-422/485

RECOMMENDATION ITU-R BT *

Digital Electronic Thermostat With RF

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Trillium US Inc. E500 Dual Channel Temperature Monitor User s Manual Rev A / November 2015

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual

)454 1 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

TECHNICAL DESCRIPTION

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

ND1603:2003/04. Specification of the KCH Metallic Path Facility. Issue 2. NICC DSL Task Group

Bosch Smart Home. Door/Window Contact Instruction Manual

) ,4)&2%15%.#9 053("544/. 3)'.!, 2%#%04)/. '%.%2!, 2%#/--%.$!4)/.3 /. 4%,%0(/.% 37)4#().'!.$ 3)'.!,,).'

A-16D A-Net Distributor

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

King Fahd University of Petroleum & Minerals Computer Engineering Dept

Absolute Block. Uncontrolled When Printed Document to be part superseded by GKRT0055 Iss 1 and GKRT0077 Iss 1 (published on 07/09/2013)

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

CDS CALLING LINE IDENTIFICATION SERVICE TERMINAL EQUIPMENT REQUIREMENTS PART 1 IDLE STATE, DOWN STREAM SIGNALLING PART 2 LOOP STATE SIGNALLING

9600 bps, Dual Modem 170 Card Private Wire Only

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Part IV: Glossary of Terms

khz to 2.9 GHz Spectrum Analyzer

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

AS/ACIF S016:2001. Australian Standard. Requirements for Customer Equipment for connection to hierarchical digital interfaces

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

CROSS Chassis from 160 A to 450 A

Stat-4 Stat-8 Stat-24

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

SOUNDMASTER VF 400 MOS-FET POWER AMPLIFIER OWNERS MANUAL

E-800 power amplifier. user manual

TWS 16 BT UHF wireless system. user manual

)454 1 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

4 Channel Frequency Conscious Noise Gate. Operation Manual

Maintenance Manual. Simulcast Interface Panel 19D904009G5 & G4. ericssonzy LBI TABLE OF CONTENTS

4612 Reference Guide

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation. CXE880 Fibre node

The use of diversity for voice-frequency telegraphy on HF radio circuits

SERIES K: PROTECTION AGAINST INTERFERENCE

CX-A6 Amplifier Installation & User Guide V8.0

TOA NEW 900 SERIES POWER AMPLIFIER

ETSI EN V7.0.1 ( )

Transcription:

SIN 57 Issue 2.4 May 2018 Suppliers' Information Note For The BT Network BT KiloStream X.21 Interface Service Description Each SIN is the copyright of British Telecommunications plc. Reproduction of the SIN is permitted only in its entirety, to disseminate information on the BT Network within your organisation. You must not edit or amend any SIN or reproduce extracts. You must not remove BT trade marks, notices, headings or copyright markings. This document does not form a part of any contract with BT customers or suppliers. Users of this document should not rely solely on the information in this document, but should carry out their own tests to satisfy themselves that terminal equipment will work with the BT network. BT reserves the right to amend or replace any or all of the information in this document. BT shall have no liability in contract, tort or otherwise for any loss or damage, howsoever arising from use of, or reliance upon, the information in this document by any person. Due to technological limitations a very small percentage of customer interfaces may not comply with some of the individual characteristics which may be defined in this document. Publication of this Suppliers' Information Note does not give or imply any licence to any intellectual property rights belonging to British Telecommunications plc or others. It is your sole responsibility to obtain any licences, permissions or consents which may be necessary if you choose to act on the information supplied in the SIN. This SIN is available in Portable Document Format (pdf) from: http://www.btplc.com/sinet/ Enquiries relating to this document should be directed to: sinet.helpdesk@bt.com British Telecommunications plc Registered Office 81 Newgate Street LONDON EC1A 7AJ Registered in England no.1800000

CONTENTS 1. INTRODUCTION... 3 2. SERVICE OUTLINE... 3 3. SERVICE AVAILABILITY... 4 4. ENVELOPING, LINE RATES, & MODULATION... 4 5. KILOSTREAM X.21 NTU/DTE INTERFACE... 4 5.1 2.4-48KBIT/S STRUCTURED CIRCUITS... 4 5.1.1 Remote loops... 5 5.1.2 Local Loops... 5 5.2 64KBIT/S UNSTRUCTURED CIRCUITS... 5 5.3 X.21 INTERCHANGE CIRCUITS... 5 6. KILOSTREAM X.21 BIS (V.24 & V.35) NTU/DTE INTERFACES... 6 6.1 X.21 BIS (V.24 & V.35) CIRCUIT OPTIONS... 6 6.1.1 Local and Remote Loops... 6 6.2 X.21 BIS (V.24 & V.35) INTERCHANGE CIRCUITS... 7 6.3 X.21 BIS (V.24 & V.35) SUB-OPTIONS... 8 7. NETWORK TERMINATING EQUIPMENT... 8 8. POWER SUPPLY... 9 9. OPERATING ENVIRONMENT... 9 10. FURTHER INFORMATION... 10 11. REFERENCES... 10 12. GLOSSARY... 10 13. HISTORY... 11 SIN 57 Issue 2.4 British Telecommunications plc Page 2 of 11

1. Introduction This Suppliers' Information Note (SIN) describes the "BT KiloStream" service using the X.21 [1] and X.21 bis [2] (V.24 & V.35) interfaces. The SIN provides information about this service for terminal equipment manufacturers and developers. supply in November 2012. All remaining KiloStream products (i.e. 48kbit/s and 64kbit/s services) were withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. 2. Service Outline The BT KiloStream service enables the exchange of serial binary synchronous data, using point to point private circuits with digital transmission throughout the network. The service incorporates extensive supervisory, alarm, and testing facilities. supply in November 2012. All remaining KiloStream products (i.e. 48kbit/s and 64kbit/s services) were withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. The X.21 / X.21 bis interfaces facilitate full duplex transmission of data at 2400, 4800, 9600, 19200 and 48000bit/s over the network. In addition, an 'unstructured' 64000bit/s facility is available which uses Data and Timing circuits only. X.21 bis (V.24 & V.35) interfaces allow connection of Data Terminal Equipment (DTE) which is designed for interfacing to synchronous V series modems. Table 1 illustrates the range of X.21 & X.21 bis interfaces and associated data speed options. Table 1: Speeds and interfaces Speed kbit/s X.21 X.21 bis (V.24) 2.4 * * 4.8 * * 9.6 * * 19.2 * * X.21 bis (V.35) 48 * * 64 * It should be noted that the KiloStream service enables Network Terminating Units (NTU) [also known as Data Circuit-Terminating Equipment - DCE] having an X.21 interface to SIN 57 Issue 2.4 British Telecommunications plc Page 3 of 11

work to an NTU operating at the same data rate but using an X.21 bis interface, thus giving flexibility in the use of DTE. 3. Service Availability The BT KiloStream service, implementing the X.21 & X.21 bis interfaces, was launched in 1982 throughout the UK (inland only). supply in November 2012. All remaining KiloStream products (i.e. the 48kbit/s and 64kbit/s services) were withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. 4. Enveloping, Line Rates, & Modulation The NTU will code contiguous, isochronous binary data received from the DTE into envelopes with a 6 + 2 structure. This procedure applies to all data rates except 64kbit/s which is not structured. The data is then modulated using a diphase modulation technique known as WAL 2. The NTU also performs the complementary demodulation and decoding in the receive path. 5. KiloStream X.21 NTU/DTE Interface The X.21 interface is a 15 way D-type socket (female) and is available at all speeds. The offering is set as shown in Sec. 5.1 & 5.2 with no variable options. 5.1 2.4-48kbit/s structured circuits supply in November 2012. All remaining KiloStream products (including the 48kbit/s service) was withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. Local and remote loops may be activated by means of buttons on the NTU or by the Data Terminal Equipment (DTE). SIN 57 Issue 2.4 British Telecommunications plc Page 4 of 11

5.1.1 Remote loops Remote loops can be applied from the DTE if the following conditions are satisfied: The Control (Circuit C) is OFF The DTE sends a continuous 11001100 pattern This pattern must be preceded by at least one Binary 1 within the preceding 16 bit intervals Loop activation is indicated by return of the 11001100 sequence. The DTE responds to loop activation within 0.7 seconds by an OFF to ON transition on the Control (Circuit C) The loop will subsequently be removed when an ON to OFF transition is placed on the Control (Circuit C) by the DTE 5.1.2 Local Loops Local loops can be applied from the DTE if the following conditions are satisfied: The Control (Circuit C) at both ends is OFF The DTE sends on the T circuit a binary pattern consisting of 11001100 with control OFF This pattern must be preceded by a continuous Binary 0 pattern persisting for at least 24 bit intervals Loop activation is indicated by return of the 11001100 sequence. The DTE responds to loop activation within 0.7 seconds by an OFF to ON transition on the Control (Circuit C) The loop will subsequently be removed when an ON to OFF transition is placed on the Control (Circuit C) by the DTE. The local loop pattern is referred to as Local Loop Code A. All KiloStream NTUs will respond to this code, although those with an LCD display will also respond to Local Loop Code B. This code consists of a continuous 11110000 pattern. All other conditions are the same as for Local Loop Code A activation. 5.2 64kbit/s unstructured circuits On X.21 unstructured circuits, test loops can only be applied at the NTU. Note: The 64kbit/s KiloStream service was withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. 5.3 X.21 Interchange Circuits ITU-T circuit designation Table 2: X.21 Interchange Circuits Direction of signalling Circuit description PIN number A G Common return 8 - T DTE-NTU Transmit data 2 9 R NTU-DTE Receive data 4 11 C DTE-NTU Control 3 10 I NTU-DTE lndication 5 12 S NTU-DTE Signal element timing 6 13 Circuits working at 64kbit/s data rate are unstructured' and use G, T, R and S circuits. However, I circuit will be B SIN 57 Issue 2.4 British Telecommunications plc Page 5 of 11

permanently ON except under fault conditions 6. KiloStream X.21 bis (V.24 & V.35) NTU/DTE Interfaces These interfaces allow connection of data terminal equipment that is designed for interfacing to synchronous V series modems. 6.1 X.21 bis (V.24 & V.35) Circuit Options supply in November 2012. All remaining KiloStream products (including the X21 bis V.35 interface) was withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. V.24 presentation can be supplied for speeds up to and including 19.2kbit/s using a 25 way D-type socket (female). There are further sub-options on electrical interchange circuits 106, 107 and 108/1 (See Sec. 6.3). V.35 presentation can only be supplied for a speed of 48kbit/s, using a MRAC 34S-J2 socket (female). There are further sub-options on electrical interchange circuits 106 and 107 (See Sec. 6.3). 6.1.1 Local and Remote Loops Remote and local loops may be activated from either the NTU or the DTE. Remote loops are controlled via circuit 140. If this circuit is ON, a remote loop is applied. When the condition on circuit 140 is removed, the loop is deactivated. Local loops are controlled in a similar manner; but utilise circuit 141. SIN 57 Issue 2.4 British Telecommunications plc Page 6 of 11

6.2 X.21 bis (V.24 & V.35) Interchange Circuits ITU-T circuit number Table 3: Interchange circuits X.21 bis (V.24) [2.4-19.2kbit/s] Direction of signalling Circuit description PIN number 102 - Common return 7 103 DTE-NTU Transmit data 2 104 NTU-DTE Receive data 3 105 DTE-NTU Request to send 4 106 NTU-DTE Ready for sending 5 107 NTU-DTE Data set ready 6 108/1 DTE-NTU Connect data set to line 20 109 NTU-DTE Data channel received line 8 signal detector 114 NTU-DTE Transmitter signal element 15 timing 115 NTU-DTE Receiver signal 17 element timing 140 DTE-NTU Remote loopback 21* 141 DTE-NTU Local loopback 18* 142 NTU-DTE Test indicator 25* * If these circuits are not used by the DTE they must be correctly terminated or disconnected (see note 1) Table 4: Interchange circuits X.21 bis (V.35) [48kbit/s only] ITU-T circuit Direction of Balanced Unbalanced Circuit PIN designation number signalling circuit circuit description A T 102 - x Common return B 103 DTE-NTU x Transmit data P S 104 NTU-DTE x Receive data R T 105 DTE-NTU x Request to send C 106 NTU-DTE x Ready for sending D 107 NTU-DTE x Data set ready E 109 NTU-DTE x Data channel received line signal detector F 114 NTU-DTE x Transmitter signal Y AA(a)** element timing 115 NTU-DTE x Receiver signal element timing V X 140 DTE-NTU x Remote loopback N* 141 DTE-NTU x Local loopback L* 142 NTU-DTE x Test indicator NN*(m)** * If these circuits are not used by the DTE they must be correctly terminated or disconnected (see note 1) ** Letters in brackets ( ) indicate alternative connector labelling SIN 57 Issue 2.4 British Telecommunications plc Page 7 of 11

note 1: Interchange circuits not used by the DTE It is important that all conductors connected to pins listed in the tables are either: Correctly terminated at the DTE as specified in the relevant ITU-T recommendation at all times, or Disconnected on the interface cable at the NTU connector end. This avoids spurious conditions on interchange circuits causing incorrect operation of the NTU. This is especially important on loop control circuits 140 and 141. 6.3 X.21 bis (V.24 & V.35) sub-options supply in November 2012. All remaining KiloStream products (including the X21 bis V.35 interface) was withdrawn from new supply on 1 st September 2016. It is further expected that all KiloStream products (at all speeds) will be completely withdrawn from service in March 2020. The table below shows the various option codes used by BT to ensure a new circuit is correctly configured. The first options shown in each case are the most likely to be used. Table 5: X.21 & X.21 bis sub-options ITU-T Interchange circuit with an interface option BT suggested defaults Customer alternatives X.21 bis (V.24) Circuit 106 Ready for send delay (RFS) Circuit 108/1 Connect data set to line (CDSTL) Circuit 107 Data set ready (DSR) X.21 bis(v.35) Circuit 106 Ready for send delay (RFS) Circuit 107 Data set ready (DSR) Zero delay Permanently ON To follow CDSTL Zero delay To follow CDSTL l0-20ms delay Controlled by terminal equipment Set OFF under fault conditions 10-20ms delay Set OFF under fault conditions 7. Network Terminating Equipment A KiloStream circuit is provided with an NTU at either end. These units provide the correct interfaces to ITU-T standards and are connected to a mains power supply The NTU consists of a single printed circuit card, which can be housed in one of two ways. Single unit The NTU is housed in a moulded plastic case that is designed to rest on a desktop. The customer's Data Terminal Equipment interface is located at the rear of the case, together with a line connection card and a 3 metre long mains cable complete with a BS1363 [3], 3 pin moulded plug top. Multiple installation The NTU can be mounted in a KiloStream shelf. The shelf is in 19 inch rack equipment SIN 57 Issue 2.4 British Telecommunications plc Page 8 of 11

practice, 6 vertical units (VU) high. It can provide for up to 12 KiloStream circuits of any combination of types. 8. Power supply Single unit The socket must meet the requirements of British Standards Specifications BS1363 and be wired in accordance with the 15th edition of the IEE wiring regulations. Subject to building fire regulations, this unit must be powered at all times. Shelf Mounted The external power supply should be connected on installation and the shelf power unit switched ON. Again, subject to building fire regulations, this unit must be powered at all times. 9. Operating Environment Table 6: Shelf mounted NTU specifications Dimensions H 261 mm x W 25mm x D 248mm Weight 0.55kg Power requirements 240V at 50Hz Power consumption Approximately 7 watts (100 watts fully loaded shelf) Table 7: Shelf mounted NTU specifications Single unit specifications Dimensions H 55mm x W 251 mm x D 274mm Weight 2.9kg Power requirements 240V RMS AC -10% to +6% 45Hz to 55Hz Power consumption Approximately 8 watts Operating environment 5 0 C to 55 0 C Relative humidity 90% non-condensing (max) at a temperature range of 20-45 0 C Table 8: KiloStream shelf specifications Dimensions H 266mm x W 482mm x D 269mm (6VU) Weight 16.12kg 240V RMS AC 45Hz to 55Hz Power consumption Operating environment Approximately 100 watts fully equipped 5 0 C to 55 0 C Relative humidity 90% non-condensing (max) at a temperature range of 20-45 0 C The shelf can also be housed in one of two ways: Table 9: Further shelf housing options Housing Number of shelves/circuits Dimensions Case Up to 1/12 H 270mm W 540mm D 400mm Cabinet Up to 4/48 H 1730mm W 600mm D 600mm Description A metal case with a perspex front cover designed to rest on a desk top Power, line & data interface connectors are provided at the rear. A metal cabinet with full length doors fitted front and rear. Power and line connectors are permanently cabled in Interface connectors are situated at the SIN 57 Issue 2.4 British Telecommunications plc Page 9 of 11

Customer owned rack or cabinet bottom of the cabinet at the front or as advised The shelf can be fitted into any suitable l9in practice rack subject to BT approval. 10. Further information Contacts for further information can be found at http://www.btplc.com/sinet/ Alternatively please contact either: Your Company s BT account manager For business customers, BT sales on 0800 800152 for product and service information, sales and rental enquiries. If you have enquiries relating to this document then please contact: sinet.helpdesk@bt.com 11. References [1] ITU-T Rec.X.21 Interface between Data Terminal Equipment and Data Circuitterminating Equipment for synchronous operation on public data networks [2] ITU-T Rec.X.21 bis Use on public data networks of Data Terminal Equipment (DTE) which is designed for interfacing to synchronous V-Series modems [3] BS1363 Specification for 13 A fused plugs and switched and unswitched socket-outlets 1992 1988 Latest Issue For further information or copies of referenced sources, please see document sources at: http://www.btplc.com/sinet/ SINs are available from http://www.btplc.com/sinet/ 12. Glossary CCITT DCE DTE ITU-T NTU SIN RFS CDSTL DSR VU International Telegraph and Telephone Consultative Committee Data Circuit-terminating Equipment (aka NTU) Data Terminal Equipment International Telecommunications Union - Telecommunication standardisation sector (formerly CCITT). Network Terminating Unit (aka DCE) Suppliers' Information Note Ready For Service Connect Data Set To LIne Data Set Ready Vertical Unit SIN 57 Issue 2.4 British Telecommunications plc Page 10 of 11

13. History Issue 1.0 April 1982 SIN 57, 58, and 59 first Issued. Issue 2.0 November 2002 X.21 & X.21 bis SINs (57/58/59) rationalised into one document. Issue 2.1 December 2003 Approval Requirements statement removed, information available via SINet Useful Contacts page. Issue 2.2 November 2012 Note added about the withdrawal of some speeds and interface options from new supply Issue 2.3 January 2016 Note added about the timeframes for the withdrawal of the remaining speeds and interface options from new supply and subsequent final closure of KiloStream services. Change SINet site references from http://www.sinet.bt.com to http://www.btplc.com/sinet/ Issue 2.4 May 2018 Editorial changes to the notes on withdrawal timeframes. -END- SIN 57 Issue 2.4 British Telecommunications plc Page 11 of 11