06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Similar documents
Binary Output Series 9175

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolating Repeater Input Series 9163

Binary Output without Power Supply Series 9176

Isolators A3/1. Vibration Transducer Supply Unit Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Isolators A3/1.

Fieldbus Isolating Repeater Series 9185/11

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 2 Series 9470/33

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital I/O Coupler (4-wire) Series 9413/21

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Output Module for Zone 2 Series 9470/33

Temperature Input Module for Zone 1 Series 9482/32

Single-Channel Safety Barriers Series 9001

Remote I/O. 74 Remote I/O. Remote I/O System

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

Inductive sensor slot-type SI2-K08-AP7

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail

Technical Data. General specifications. Rated operating distance s n 3 mm

Temperature Transmitter itemp RTD DIN rail TMT 127

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Technical Information Barrier RB223

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Motor Protection Circuit Breaker Series 8146/5-V27

Assembly. Front view. Power Rail

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Safety Instructions Nivotester FTC625, FTC325

Assembly. Front view. Parametrization interface. Power Bus

Temperature transmitter itemp RTD DIN rail TMT 127

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

SINEAX B 811 Power Pack with additional Functions

Temperature transmitter itemp PCP DIN rail TMT 121

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

0 2 1 â Ó. itemp HART TMT182. Technical Information

onlinecomponents.com

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Technical Information RMA42

itemp HART DIN rail TMT112

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature Measurement Transmitters for mounting in sensor head

RMA42. Technical Information

Head mounted Temperature Transmitter TF02/TF02-Ex

Level Limit Switch nivotester FTL 325 P

Type Nominal voltage (V) Code HSV V

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Control Unit Series 8208

Zelio Control Measurement Relays

Rail mounted Temperature Transmitter TH102/TH102-Ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

MACX MCR-EX-SL-RPSSI-I

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Operating Instructions

Transcription:

Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched off) > Inversion of output signal can be set > Transmission frequency up to 10 khz > For use up to SIL 2 (relay - output) or SIL 3 (electronic - output) (IEC 61508) www.stahl.de Series 9170 06528E00 Basic function: binnary / digital input, 1and 2 channels. The switching repeaters are suitable typically for intrinsically safe operation of contacts, proximity switches to EN 60947-5-6 (NAMUR), optocoupler outputs etc. The version 9170/.1-14-12 LFT is characterised by line fault transparency. This function makes it possible to signal cable faults directly to the control level via the signal channel. The output of the switching repeater behaves acc. to EN 60947-5-6 (NAMUR). ATEX / IECEx NEC 505 NEC 506 NEC 500 *) Restrictions see table explosion protection Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 2 1 2 1 2 Ex i interface x x x x x x Ex i interface x x x Ex i interface x x x x x x Installation in x *) x *) Installation in x *) x *) Installation in x *) x *) x *) WebCode 9170A Isolators /1

Switching Repeater Series 9170 Selection Table Output version (control) Signal relay (125 V / 1 A) Power relay (250 V / 4 A) Electronic (35 V / 50 ma) Note Channels Power supply Output / channel LFD relay LFT Order number Tech. data see page 1 24 V DC 2 change-over contacts yes no 9170/10-11-11s /3 120... 230 V AC 2 change-over contacts no no 9170/10-11-21s 2 24 V DC 1 change-over contact yes no 9170/20-10-11s 2 NO yes no 9170/20-11-11s 120... 230 V AC 1 change-over contact no no 9170/20-10-21s 2 NO no no 9170/20-11-21s 1 24 V DC 1 change-over contact yes no 9170/10-12-11s /8 120... 230 V AC 1 change-over contact no no 9170/10-12-21s 2 change-over contacts no no 9170/10-13-21s 2 24 V DC 1 change-over contact yes no 9170/20-12-11s 120... 230 V AC 1 change-over contact no no 9170/20-12-21s 1 24 V DC 1 electronic output yes no 9170/11-14-11s /12 yes 9170/11-14-12s /15 2 24 V DC 1 electronic output yes no 9170/21-14-11s /12 yes 9170/21-14-12s /15 The order numbers listed in the table are for devices equipped with screw-type terminals. For devices equipped with spring-type terminals, replace the ending "s" for screw-type terminals with "k" for spring-type terminals. LFD - Line fault diagnostic no - device transmits line fault via LED yes - device transmits line fault via LED and relay contact LFT - line fault transparency, device signals line fault on field side to the control directly via the signal output. /2 Isolators

Switching Repeater with Signal relay (125 V / 1 A) Type 9170/.0-11-.1., Type 9170/20-10-.1. Type 9170/.0-11-.1., Type 9170/20-10-.1. Explosion Protection Version Global (IECEx) 24 V DC 9170/.0-11-11., 9170/20-10-11. 120... 230 V AC 9170/.0-11-21., 9170/20-10-21. Gas and dust IECEx BVS 09.0041X IECEx BVS 09.0041X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Da] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X Certifications and certificates Certificates E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (TR), Russia (TR), Ukraine (TR), USA (FM, UL), Belarus (TR) Ship approval DNV DNV Safety data E II (1) G [Ex ia Ga] IIC E II (1) D [Ex ia Da] IIIC IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (TR) Version 9170/10-..-.. (1 channel) 9170/20-..-.. (2 channels) Inputs (channels individually) Max. voltage U o 10.6 V 10.6 V Max. current I o 24 ma 24 ma Max. power P o 64 mw 64 mw capacitance C o IIC 2,32 mf 2,32 mf IIB 16,2 mf 16,2 mf inductance L o IIC 63 mh 63 mh IIB 230 mh 230 mh Internal capacitance C i 2.42 nf 2.42 nf Internal inductance L i negligible negligible Insulation voltage U m 253 V 253 V Inputs (2 channels parallel) Max. voltage U o 10.6 V Max. current I o 48 ma Max. power P o 128 mw capacitance C o IIC 2,32 mf IIB 16,2 mf inductance L o IIC 16 mh IIB 61 mh Internal capacitance C i 4.84 nf Internal inductance L i negligible Insulation voltage U m 253 V Further parameters Installation in Zone 2, Div. 2 and in the safe area in safe area Further information see respective certificate and operating instructions Isolators /3

Switching Repeater with Signal relay (125 V / 1 A) Type 9170/.0-11-.1., Type 9170/20-10-.1. Electrical data Version 24 V DC 9170/.0-11-11., 9170/20-10-11. 120... 230 V AC 9170/.0-11-21., 9170/20-10-21. Auxiliary power Nominal voltage U N 24 V DC 120... 230 V AC Voltage range 18... 31.2 V 96... 253 V Residual ripple < 3.26 V SS Frequency range 48... 62 Hz Nominal current at U N 1 channel 33 ma 12 ma 2 channels 55 ma 18 ma Power consumption at U N 1 channel 0.8 W 120 V AC : 1.4 VA 230 V AC : 1.8 VA 2 channels 1.3 W 120 V AC : 2.2 VA 230 V AC : 2.8 VA Power dissipation 1 channel 0.8 W 120 V AC: 1.0 W 230 V AC: 1.3 W 2 channels 1.3 W 120 V AC: 1.6 W 230 V AC: 2.0 W Polarity reversal protection yes Operation indication LED green PWR LED green PWR Undervoltage monitoring yes (no faulty module / output states) yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 EN 60079-11 Ex i input to output 1.5 kv AC 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC 1.5 kv AC Ex i inputs interconnected 500 V AC 500 V AC Ex i input to error message 1.5 kv AC 1.5 kv AC contact acc. to standard EN 50178 EN 50178 Output to auxiliary power 1.1 kv AC 1.1 kv AC Outputs interconnected 1.1 kv AC 1.1 kv AC Error contact to power supply 350 V AC 350 V AC Error contact to outputs 1.1 kv AC 1.1 kv AC Ex i input Input signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR) Current for ON / OFF ON ) 2.1 ma ) 2.1 ma OFF ( 1.2 ma ( 1.2 ma Hysteresis approx. 0.2 ma approx. 0.2 ma Open-circuit voltage 8.2 V 8.2 V Short-circuit current ( 8.2 ma ( 8.2 ma Internal resistance 1000 Ω 1000 Ω Output Minimum load 1 V / 100 ma 1 V / 100 ma Maximum load DC 125 V / 1 A 125 V / 1 A Maximum load AC 125 V / 1 A 125 V / 1 A Max. switching capacity 25 W / 50 VA 25 W / 50 VA Overload protected Voltage drop Electrical service life Resistive load 5 x 10 5 cycles at 24 V / 1 A 5 x 10 5 cycles at 24 V / 1 A Mechanical service life 1 x 10 8 cycles 1 x 10 8 cycles Recommended back-up fuses ( F 1 A AC / DC ( F 1 A AC / DC Max. switching frequency 15 Hz 15 Hz Switching delay ON / OFF 5 ms 5 ms Switching delay OFF / ON 5 ms 5 ms Settings (switch INV) Inversion of operating mode Inversion of operating mode Indication LED yellow OUT per channel LED yellow OUT per channel /4 Isolators

Switching Repeater with Signal relay (125 V / 1 A) Type 9170/.0-11-.1., Type 9170/20-10-.1. Electrical data Error detection Ex i input Open circuit I in < 0.05... 0.35 ma according to EN 60947-5-6 Short circuit R in < 100... 360 Ω according to EN 60947-5-6 Behaviour of the output OFF Settings (switch LF) activated / deactivated Error detection LED red "LF" each channel Message of line fault and - contact (30 V / 100 ma), closed to ground in case of fault *) auxiliary power failure - pac-bus, floating contact (30 V / 100 ma) *) *) not at 9170/.0-1.-21. Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 (can be used in industrial environment) NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Isolators /5

Switching Repeater with Signal relay (125 V / 1 A) Type 9170/.0-11-.1., Type 9170/20-10-.1. Electrical connection Connection diagram 24 V DC 1 channel 9170/10-11-11 Zone0/1 pac-bus Division 2 Zone 2 06696E02 2 channels 9170/20-11-11 Zone0/1 pac-bus Division 2 Zone 2 06699E02 2 channels 9170/20-10-11 pac-bus Division 2 Zone 2 14359E02 /6 Isolators

Switching Repeater with Signal relay (125 V / 1 A) Type 9170/.0-11-.1., Type 9170/20-10-.1. Electrical connection Connection diagram 120 V / 230 V AC 1 channel 9170/10-11-21 12835E02 2 channels 9170/20-11-21 2 channels 9170/20-10-21 12836E02 14360E02 Isolators /7

Switching Repeater with Power Relay (250 V / 4 A) Type 9170/.0-12-.1., Type 9170/.0-13-21. Type 9170/.0-12-.1., Type 9170/.0-13-21. Explosion Protection Version Global (IECEx) 24 V DC 9170/.0-12-11. 120... 230 V AC 9170/.0-12-21., 9170/.0-13-21. Gas and dust IECEx BVS 09.0041X IECEx BVS 09.0041X [Ex ia Ga] IIC [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Da] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X DMT 02 ATEX E195X Certifications and certificates Certificates E II (1) G [Ex ia Ga] IIC E II (1) D [Ex ia Da] IIIC IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (TR) Ship approval DNV DNV Safety data E II (1) G [Ex ia Ga] IIC E II (1) D [Ex ia Da] IIIC IECEx, ATEX, Brazil (INMETRO), India (PESO), Canada (CSA), Kazakhstan (TR), Korea (KCs) only for 9170/10-12-21., Russia (TR), Serbia (SRPS), USA (FM, UL), Belarus (TR) Version 9170/10-..-.. (1 channel) 9170/20-..-.. (2 channels) Inputs (channels individually) Max. voltage U o 10.6 V 10.6 V Max. current I o 24 ma 24 ma Max. power P o 64 mw 64 mw capacitance C o IIC 2,32 mf 2,32 mf IIB 16,2 mf 16,2 mf inductance L o IIC 63 mh 63 mh IIB 230 mh 230 mh Internal capacitance C i 2.42 nf 2.42 nf Internal inductance L i negligible negligible Insulation voltage U m 253 V 253 V Inputs (2 channels parallel) Max. voltage U o 10.6 V Max. current I o 48 ma Max. power P o 128 mw capacitance C o IIC 2,32 mf IIB 16,2 mf inductance L o IIC 16 mh IIB 61 mh Internal capacitance C i 4.84 nf Internal inductance L i negligible Insulation voltage U m 253 V Further parameters Installation in safe area Further information see respective certificate and operating instructions /8 Isolators

Switching Repeater with Power Relay (250 V / 4 A) Type 9170/.0-12-.1., Type 9170/.0-13-21. Electrical data Version 24 V DC 9170/.0-12-11. 120... 230 V AC 9170/.0-12-21., 9170/.0-13-21. Auxiliary power Nominal voltage U N 24 V DC 120... 230 V AC Voltage range 18... 31.2 V 96... 253 V Residual ripple < 3.26 V SS Frequency range 48... 62 Hz Nominal current at U N 1 channel 33 ma 12 ma 2 channels 55 ma 18 ma Power consumption at U N 1 channel 0.8 W 120 V AC : 1.4 VA 230 V AC : 1.8 VA 2 channels 1.3 W 120 V AC : 2.2 VA 230 V AC : 2.8 VA Power dissipation 1 channel 0.8 W 120 V AC: 1.0 W 230 V AC: 1.3 W 2 channels 1.3 W 120 V AC: 1.6 W 230 V AC: 2.0 W Polarity reversal protection yes Operation indication LED green PWR LED green PWR Undervoltage monitoring yes (no faulty module / output states) yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 EN 60079-11 Ex i input to output 1.5 kv AC 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC 1.5 kv AC Ex i inputs interconnected 500 V AC 500 V AC Ex i input to error message 1.5 kv AC 1.5 kv AC contact acc. to standard EN 50178 EN 50178 Output to auxiliary power 1.1 kv AC 1.1 kv AC Outputs interconnected 1.1 kv AC 1.1 kv AC Error contact to power supply 350 V AC 350 V AC Error contact to outputs 1.1 kv AC 1.1 kv AC Ex i input Input signal acc. to EN 60947-5-6 (NAMUR) acc. to EN 60947-5-6 (NAMUR) Current for ON / OFF ON ) 2.1 ma ) 2.1 ma OFF ( 1.2 ma ( 1.2 ma Hysteresis approx. 0.2 ma approx. 0.2 ma Open-circuit voltage 8.2 V 8.2 V Short-circuit current ( 8.2 ma ( 8.2 ma Internal resistance 1000 Ω 1000 Ω Output Minimum load 12 V / 100 ma 12 V / 100 ma Maximum load DC 250 V / 2 A 250 V / 2 A Maximum load AC 250 V / 4 A 250 V / 4 A Max. switching capacity 50 W / 1000 VA 50 W / 1000 VA Overload protected Voltage drop Electrical service life Resistive load 1 x 10 5 cycles at 250 V / 4 A 1 x 10 5 cycles at 250 V / 4 A Mechanical service life 15 x 10 6 cycles 15 x 10 6 cycles Recommended back-up fuses ( F 4 A AC / 2 A DC ( F 4 A AC / 2 A DC Max. switching frequency 6 Hz 6 Hz Switching delay ON / OFF 10 ms 10 ms Switching delay OFF / ON 10 ms 10 ms Settings (switch INV) Inversion of operating mode Inversion of operating mode Indication LED yellow OUT per channel LED yellow OUT per channel Isolators /9

Switching Repeater with Power Relay (250 V / 4 A) Type 9170/.0-12-.1., Type 9170/.0-13-21. Electrical data Error detection Ex i input Open circuit I in < 0.05... 0.35 ma according to EN 60947-5-6 Short circuit R in < 100... 360 Ω according to EN 60947-5-6 Behaviour of the output OFF Settings (switch LF) activated / deactivated Error detection LED red "LF" each channel Message of line fault and - contact (30 V / 100 ma), closed to ground in case of fault *) auxiliary power failure - pac-bus, floating contact (30 V / 100 ma) *) *) not at 9170/.0-1.-21. Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 (can be used in industrial environment) NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Electrical connection Connection diagram 24 V DC 1 channel 9170/10-12-11 pac-bus 06698E02 2 channels 9170/20-12-11 pac-bus 06695E02 /10 Isolators

Switching Repeater with Power Relay (250 V / 4 A) Type 9170/.0-12-.1., Type 9170/.0-13-21. Electrical connection Connection diagram 120 V / 230 V AC 1 channel, 1 changeover 9170/10-12-21 06871E02 2 channels 9170/20-12-21 1 channel, 2 changeover 9170/10-13-21 07219E02 06874E02 Isolators /11

Switching Repeater with Electronic Output (35 V / 50 ma) Type 9170/.1-14-11. Type 9170/.1-14-11. Explosion Protection Global (IECEx) Gas and dust IECEx BVS 09.0041X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X E II 3 (1) G Ex nac ncc [ia] IIC T4 E II (1) D [Ex ia] IIIC Certifications and certificates Certificates Ship approval Safety data IECEx, ATEX, India (PESO), Canada (CSA), Kazakhstan (TR), Russia (TR), USA (FM), Belarus (TR) DNV Version 9170/11-..-.. (1 channel) 9170/21-..-.. (2 channels) Inputs (channels individually) Max. voltage U o 9.6 V 9.6 V Max. current I o 10 ma 10 ma Max. power P o 24 mw 24 mw capacitance C o IIC 3,6 mf 3,6 mf IIB 26 mf 26 mf I 99 mf 99 mf inductance L o IIC 350 mh 350 mh IIB 1000 mh 1000 mh I 1000 mh 1000 mh Internal capacitance C i 2.42 nf 2.42 nf Internal inductance L i negligible negligible Insulation voltage U m 253 V 253 V Inputs (2 channels parallel) Max. voltage U o 9.6 V Max. current I o 20 ma Max. power P o 48 mw capacitance C o IIC 3,6 mf IIB 26 mf I 99 mf inductance L o IIC 90 mh IIB 340 mh I 1000 mh Internal capacitance C i 4.84 nf Internal inductance L i negligible Insulation voltage U m 253 V Further parameters Installation in Zone 2, Div. 2 and in the safe area Further information see respective certificate and operating instructions /12 Isolators

Switching Repeater with Electronic Output (35 V / 50 ma) Type 9170/.1-14-11. Electrical data Auxiliary power Nominal voltage U N 24 V DC Voltage range 18... 31.2 V Residual ripple < 3.26 V SS Nominal current at U N 1 channel 26 ma 2 channels 36 ma Power consumption at U N 1 channel 0.6 W 2 channels 0.9 W Power dissipation 1 channel 0.6 W 2 channels 0.9 W Polarity reversal protection yes Operation indication LED green PWR Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i inputs interconnected 500 V AC Ex i input to error message 1.5 kv AC contact acc. to standard EN 50178 Output to auxiliary power 1.1 kv AC Outputs interconnected 1.1 kv AC Error contact to power supply 350 V AC Error contact to outputs 1.1 kv AC Ex i input Input signal acc. to EN 60947-5-6 (NAMUR) Current for ON / OFF ON ) 2.1 ma OFF ( 1.2 ma Hysteresis approx. 0.2 ma Open-circuit voltage 8.2 V Short-circuit current ( 8.2 ma Internal resistance 1000 Ω Output Maximum load DC 35 V / 50 ma DC Maximum load AC Max. switching capacity 1.75 W Overload protected yes Voltage drop < 2 V Electrical service life Resistive load > 10 9 cycles at 35 V / 50 ma Max. switching frequency 10 khz Switching delay ON / OFF 15 ms Switching delay OFF / ON 30 ms Settings (switch INV) Inversion of operating mode Indication LED yellow OUT per channel Error detection Ex i input Open circuit I in < 0.05... 0.35 ma according to EN 60947-5-6 Short circuit R in < 100... 360 Ω according to EN 60947-5-6 Behaviour of the output OFF Settings (switch LF) activated / deactivated Error detection LED red "LF" each channel Message of line fault and auxiliary power failure - contact (30 V / 100 ma), closed to ground in case of fault - pac-bus, floating contact (30 V / 100 ma) Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 (can be used in industrial environment) NAMUR NE 21 Isolators /13

Switching Repeater with Electronic Output (35 V / 50 ma) Type 9170/.1-14-11. Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Electrical connection Connection diagram 24 V DC 1 channel 9170/11-14-11 Zone0/1 pac-bus Division 2 Zone 2 06693E02 2 channels 9170/21-14-11 Zone0/1 pac-bus Division 2 Zone 2 06694E02 /14 Isolators

Switching Repeater with Electronic Output (35 V / 50 ma) and Line Fault Transparency Type 9170/.1-14-12. Type 9170/.1-14-12. Explosion Protection Global (IECEx) Gas and dust IECEx BVS 09.0041X Ex nac ncc [ia] IIC T4, [Ex ia] IIIC Europe (ATEX) Gas and dust DMT 02 ATEX E195X E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC Certifications and certificates Certificates IECEx, ATEX, India (PESO), Canada (CSA), Kazakhstan (TR), Russia (TR), USA (FM), Belarus (TR) Ship approval DNV Explosion Protection Safety data Version 9170/11-..-.. (1 channel) 9170/21-..-.. (2 channels) Inputs (channels individually) Max. voltage U o 9.6 V 9.6 V Max. current I o 10 ma 10 ma Max. power P o 24 mw 24 mw capacitance C o IIC 3,6 mf 3,6 mf IIB 26 mf 26 mf I 99 mf 99 mf inductance L o IIC 350 mh 350 mh IIB 1000 mh 1000 mh I 1000 mh 1000 mh Internal capacitance C i 2.42 nf 2.42 nf Internal inductance L i negligible negligible Insulation voltage U m 253 V 253 V Inputs (2 channels parallel) Max. voltage U o 9.6 V Max. current I o 20 ma Max. power P o 48 mw capacitance C o IIC 3,6 mf IIB 26 mf I 99 mf inductance L o IIC 90 mh IIB 340 mh I 1000 mh Internal capacitance C i 4.84 nf Internal inductance L i negligible Insulation voltage U m 253 V Further parameters Installation in Zone 2, Div. 2 and in the safe area Further information see respective certificate and operating instructions Isolators /15

Switching Repeater with Electronic Output (35 V / 50 ma) and Line Fault Transparency Type 9170/.1-14-12. Electrical data Auxiliary power Nominal voltage U N 24 V DC Voltage range 18... 31.2 V Residual ripple < 3.26 V SS Nominal current at U N 1 channel 26 ma 2 channels 36 ma Power consumption at U N 1 channel 0.6 W 2 channels 1.9 W Power dissipation 1 channel 0.6 W 2 channels 1.9 W Polarity reversal protection yes Operation indication LED green PWR Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i inputs interconnected 500 V AC Ex i input to error message 1.5 kv AC contact acc. to standard EN 50178 Output to auxiliary power 1.1 kv AC Outputs interconnected 1.1 kv AC Error contact to power supply 350 V AC Error contact to outputs 1.1 kv AC Ex i input Input signal acc. to EN 60947-5-6 (NAMUR) Current for ON / OFF ON ) 2.1 ma OFF ( 1.2 ma Hysteresis approx. 0.2 ma Open-circuit voltage 8.2 V Short-circuit current ( 8.2 ma Internal resistance 1000 Ω Output Maximum load DC 35 V / 50 ma DC Maximum load AC Max. switching capacity 1.75 W Overload protected yes Electrical service life Resistive load > 10 9 cycles at 35 V / 50 ma Max. switching frequency 10 khz Switching delay ON / OFF 15 ms Switching delay OFF / ON 30 ms Electronic output closed R = 2.4 k Ω Electronic output opened R > 13 k Ω In case of error (signalisation R > 100 k Ω contact open) Settings (switch INV) Inversion of operating mode Indication LED yellow OUT per channel /16 Isolators

Switching Repeater with Electronic Output (35 V / 50 ma) and Line Fault Transparency Type 9170/.1-14-12. Electrical data Error detection Ex i input Open circuit I in < 0.05... 0.35 ma according to EN 60947-5-6 Short circuit R in < 100... 360 Ω according to EN 60947-5-6 Behaviour of the output OFF Settings (switch LF) activated / deactivated Error detection LED red "LF" each channel Message of line fault and - Contact in the output circuit (35 V / 50 ma) opens in case of fault auxiliary power failure - Contact (30 V / 100 ma) close to ground in case of fault - pac-bus, floating contact (30 V / 100 ma) Electromagnetic compatibility Tested under the following standards and regulations: EN 61326-1 (can be used in industrial environment) NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Electrical connection Connection diagram 1 channel 9170/11-14-12. LFT pac-bus Division 2 Zone 2 2 channels 9170/21-14-12. LFT pac-bus 07789E02 Division 2 Zone 2 07790E02 Isolators /17

Switching Repeater Series 9170 Series 9170 Mechanical data Connection Screw-type terminals Spring-type terminals Single-wire connection - rigid - flexible - flexible with core end sleeves (without / with plastic sleeve) Two-wire connection - rigid - flexible - flexible with core end sleeves 0.2... 2.5 mm 2 0.2... 2.5 mm 2 0.25... 2.5 mm 2 0.2... 1 mm 2 0.2... 1.5 mm 2 0.25... 1 mm 2 0.2... 2.5 mm 2 0.2... 2.5 mm 2 0.25... 2.5 mm 2 - - - - 0.5... 1 mm 2 Weight approx. 160 g Mounting type on top hat rail (NS35/15, NS35/7.5) or in pac-carrier Mounting orientation horizontal or vertical Enclosure IP30 Terminals IP20 Enclosure material PA 6.6 Fire resistance (UL-94) V0 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations X 99 mm / 3.90 " 17,6 mm / 0.69 " Dimension X Screw-type terminals 108 mm / 4.25 Spring-cage terminals 128 mm / 5.04 122 mm / 4.80 " 114,5 mm / 4.51" 09685E00 Accessories and Spare Parts Designation Description Order number Resistance coupling element Connection of additional contacts in the Ex area as well, in order to enable short circuit and open circuit detection. 105944 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Isolators