Model CAACS Commercial Automated Accelerometer Calibration System

Similar documents
Model CAACS Commercial Automated Accelerometer Calibration System

Table of Contents. Compendium SPEKTRA. Calibration Systems CS18. Vibration and Shock Exciters. Vibration Control Systems. Services

Do all accelerometers behave the same? Meggitt-Endevco, Anthony Chu

26 Endevco Isotron accelerometers

A New Solution for Shock and Vibration Calibration of Accelerometers

Very High Frequency Calibration of Laser Vibrometer up to 350 khz

Vibration Transducer Calibration System

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005, ANSI/NCSL Z

COPY FOR INFORMATION ONLY

Introduction to LIVM Accelerometers

Mechanically Isolated & Electrically Filtered ICP pyroshock Accelerometers. Bob Metz October 2015

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Vibration amplifier Model 6634C

Accelerometers. Providing quick, accurate and reliable motion data

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

New Long Stroke Vibration Shaker Design using Linear Motor Technology

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

The ENDEVCO high-g shock triaxial accelerometer: A smaller, more cost-effective solution to making triaxial measurements. Endevco technical paper 334

CHOOSING THE RIGHT TYPE OF ACCELEROMETER

AN5E Application Note

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

430. The Research System for Vibration Analysis in Domestic Installation Pipes

Anthony Chu. Basic Accelerometer types There are two classes of accelerometer in general: AC-response DC-response

Investigate and Optimize Your Structures with Kistler's Modal Portfolio

TRANSDUCER TEST SET (TTS) MODEL DI-803

MIL-STD-202G SHOCK (SPECIFIED PULSE)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Model 626B01. Low Frequency Industrial ICP Accelerometer. Installation and Operating Manual

V8 Vibration Test Systems

Accelerometer Sensors

Enhancing the capability of primary calibration system for shock acceleration in NML

Accelerometers. Providing quick, accurate and reliable motion data

Dytran Instruments, Inc. 1

Operating Manual. Model 832 & 832M1 Accelerometer

Test Results and Alternate Packaging of a Damped Piezoresistive MEMS Accelerometer

Sensor Datasheet Collection

Acceleration. Providing Quick, Accurate and Reliable Measurements

Certificate of Accreditation

Tactical grade MEMS accelerometer

21 st Transducer Workshop Vehicular Instrumentation/Transducer Committee

Models Z7, Z11, Z602WA and Z820WA Impedance head operating guide

Introduction To Impulse Hammers

Primary vibration calibration by laser interferometry requirements, problems and first experience with a new calibration system

A high temperature 100 mv/g triaxial accelerometer. Endevco technical paper 329

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Errata to Procedural Standard for Sound & Vibration Measurement 2015 Third Edition

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

2014 Short Form Test and Measurement Catalog

Sensor Portfolio for Machinery Health Applications

Systems. Dynamic Test. Electrodynamic Vibration Test Systems

High Temperature Velocity and Acceleration Sensor

Embedded Surface Mount Triaxial Accelerometer

Proven Sensor Performance for Emerging Shock Environments

Implementation of an Accelerometer Transverse Sensitivity Measurement System. By: Ian Veldman 3 to 5 September 2012

INSTRUCTION MANUAL. IM7298, Revision A ( )

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

1.00. MODEL HI 813 Operation and Installation Manual. Doc# REV T (July 2017)

SE 120. Piezoresistive accelerometer

Operating Manual. Model 161 PE/IEPE Signal Conditioner

Bilateral Comparison EURAMET.AUV.V-K1.2. (vibration acceleration) Swiss Federal Office of Metrology METAS Christian Hof

UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES

IPC-TM-650 TEST METHODS MANUAL

Vibration Fundamentals Training System

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

Modular Signal Conditioning System

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO

PV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line

Model 629A31. Precision Triaxial Industrial ICP Accelerometer. Installation and Operating Manual

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

4-20 ma Vibration Transmitter, Top connector

Torque Sensor Accessories and Services

DOBLE F6150e TECHNICAL SPECIFICATIONS

Velocity and Acceleration Measurements

P/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant

Model 600A13. Very High Temperature ICP Accelerometer Kit. Installation and Operating Manual

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 213, SHOCK (SPECIFIED PULSE)

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2017 ANSI/NCSL Z (R2002)

OPERATING GUIDE MODEL 3093M32 MINIATURE HIGH SENSITIVITY TRIAXIAL LIVM ACCELEROMETER WITH SINGLE 4-PIN CONNECTOR INTERNALLY CASE GROUND ISOLATED

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

Shock/Vibration/ Thermal Cycling

Low Frequency Velocity Sensor

Load Cell Accessories and Services

VCSO Mechanical Shock Compensation

sin(wt) y(t) Exciter Vibrating armature ENME599 1

A Custom Vibration Test Fixture Using a Subwoofer

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

ACCELEROMETER SELECTION BASED ON APPLICATIONS

LDTEDS: A Method for Long Distance Communication to Smart Transducers with TEDS

Hardware Inputs. Hardware Outputs. PC Connection. Software

Shaft Vibration Monitoring System for Rotating Machinery

Technology. Construction of magnetic buzzer. Construction of magnetic buzzer. Operation principles and construction

ELG3336 Design of Mechatronics System

EFFECTS OF ACCELEROMETER MOUNTING METHODS ON QUALITY OF MEASURED FRF S

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay

TIPS FROM TECHS. Understanding Current Output Signals: RMS, Peak and True Peak. Energy & Power Generation

HI-913 HARDY SHAKER Installation Manual

Transcription:

Commercial Automated Accelerometer Calibration System Features > Vibration calibration 0.5 Hz to 40 khz > Shock calibration 20 g to 10,000 g > Calibration of different type of transducers, PE, IEPE, PR, VC, Servo, Velocity > Calibration certificates may be customized by user > Electrical self-calibration > Compliance with ANSI/NCSL Z540-1-1994 and ISO 9000 > All calibrations performed are traceable to The National Institute of Standards and Technology (NIST) > Calibration in accordance with ISO/IEC 17025-2005. Color printer PC controller Pneumatically Operated Projectile (POP) (optional) Computer desk 2911 High frequency shaker (optional) Interface panel with precision oscillator Precision reference and test amplifiers Shaker protection panel 20 year warranty power amplifier Note Endevco model 2924/2924A long-stroke low frequency shaker also available (optional). Description The Endevco Commercial Automated Accelerometer Calibration System (CAACS) provides NIST traceable calibration of most accelerometer types, whether self-generating piezoelectric or accelerometers requiring current or voltage excitation. The output of the test accelerometer can be charge or voltage, signal-ended or differential, AC or DC-coupled, isolated or grounded. The Commercial Automated Accelerometer Calibration System controls up to four excitation sources, such as the pneumatically driven exciter for shock measurements, and the high frequency or low frequency shaker for vibration measurements. Test configurations and test data are stored and managed using Microsoft Access database. Tests may be automatically set up by recalling a particular test definition file which is specific to each transducer model. No operator adjustments are required for the particular gain, grounding, vibration levels, etc. Computer control helps eliminate operator error, enhances repeatability and ensures optimum signal-to-noise ratio and calibration accuracy.

Specifications Frequency range Typical measurement uncertainty 2 Hz 40 khz with model 2911 high frequency shaker 0.5 Hz 160 Hz with optional model 2924/2924A low frequency shaker Direct traceability to NIST using Endevco shakers 1.5% (1 Hz to < 100 Hz) 1.2% (100 Hz to 2.5 khz) 2.5% (> 2.5 khz to 10 khz) 5% (> 10 khz to 20 khz) Calibration method Back-to-back comparison per ISO 16063-21 Measurements Accelerometers and sensors supported Sensitivity, amplitude, phase, bias, resonance, linearity, shock, ZMO, resistance, capacitance Piezoelectric, IEPE, Piezoresistive, Variable Capacitance, Voltage, Servo, Acceleration, Velocity TEDS sensor support IEEE P1451.4 Excitation type Acceleration levels Calibration data management Automatic pass/fail classification Measurement units Main voltage supply Shaker type Reference accelerometer Type Sensitivity Frequency range Resonance frequency Test sensor mounting hole Armature Stepped sine 0.5 to 20 g Yes Yes English, metric 115 volts optional 220 volts Air-bearing 2270M18 IEPE 20 mv/g 2 Hz to 40 khz >45 khz 1/4-28 UNF (10-32 UNF, 6-32 UNC, 2-56 UNC adapters), Beryllium

Available exciters The Endevco model 2911 shaker is designed specifically for demanding requirements of comparison accelerometer calibration. The internal quartz design 2270M18 reference accelerometer built in the beryllium alloy armature is the most stable design over time, temperature and frequency and a resonance frequency far above the armature resonance. The 2911 performs precise measurements of sensitivity and frequency response from 2 Hz to 40 khz. The Endevco model 2924 long-stroke low frequency comparison vibration shaker supports the need for high signal-to-noise ratio at low frequencies, by generating larger accelerations at low frequencies. Frequency response from <1 Hz to 160 Hz. The Endevco model 2925 POP provides an accurate a controlled means of shock sensitivity calibration of accelerometers. The POP is designed to be used with the model 2270 family of back-to-back comparison calibration standard accelerometers. Calibrations are performed at accelerations from 10 g to well above 10 000 g at half-sine pulse durations from 3 ms to 100 µs. The system can be used manually in a stand-alone mode, or in a fully computer controlled mode.

Screens and certificates User customized reports and certificates Typical sweep certificate Sweep screen Shock screen Typical shock certificate

Ordering information P/N: CAACS-XX-Y-ZZ CAACS must be sold with X and/or Y option to be a complete system Configurations: XX Vibration option 00 - No vibration package Standard (S) comes with power amplifier 120 V, 60 Hz S0 - Vibration calibration module without shaker (standard, 120 V) S1-2911 (high freq) S2-2924/2924A (low freq) S3 - Both 2911 (high freq) and 2924/2924A (low freq) Euro / Asia (V) comes with power amplifier 230 V, 50 Hz V0 - Vibration calibration module without shaker V1-2911 (high freq) V2-2924/2924A (low freq) V3 - Both 2911 (high freq) and 2924/2924A (low freq) Y Shock option 0 - No shock package 1 - N/A 2-2925, POP ZZ Service plan option 0 - No service plan 1 - Basic maintenance for 1 year 2 - Basic maintenance for 2 years 3 - Basic maintenance for 3 years 4 - Premium maintenance for 1 year 5 - Premium maintenance for 2 years 6 - Premium maintenance for 3 years Domestic or International 0 - No service plan S - U.S. customer V - International customer

Warranty The CAACS is sold with a one year warranty. Service plans Service plans are available for continued support after the initial product warranty expiration. With loaner equipment options and special access to the CAACS technical support team, the plans offer a known cost of ownership and a means of accurately budgeting support requirements, ensuring that any technical issues with the system can receive immediate troubleshooting, and be back up and running with minimal downtime. For more details refer to CAACS Service Plans datasheet. 122010