APPLICATION NOTE 3560/7702. Introduction

Similar documents
NON-SELLABLE PRODUCT DATA. Order Analysis Type 7702 for PULSE, the Multi-analyzer System. Uses and Features

PRODUCT DATA. Pocket Front-end Type 3560 L PULSE Lite Software Types 7781, 7782, 7783

NON-SELLABLE PRODUCT DATA

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

VOLD-KALMAN ORDER TRACKING FILTERING IN ROTATING MACHINERY

PRODUCT DATA. Piezoelectric Accelerometer Miniature Triaxial DeltaTron Accelerometers Types 4524, 4524 B

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Mr. Wolfgang Metzen was trained as a mechanical

NOISE AND VIBRATION DIAGNOSTICS IN ROTATING MACHINERY

Theory and praxis of synchronised averaging in the time domain

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

PRODUCT DATA. PULSE Vibration Check System for Aircraft Engines Type 3641 including PULSE Standard Configuration 3560-B-T57

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

Measuring Power Supply Switching Loss with an Oscilloscope

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

PRODUCT DATA. Sound Intensity Probe Kit for 2260 Type 3595 Sound Intensity Microphone Pair Type 4197 Dual Preamplifier Type 2683

PRODUCT DATA. PULSE Reflex Angle Domain Analysis Type Uses and Features

Agilent N8480 Series Thermocouple Power Sensors. Technical Overview

KickStart Instrument Control Software Datasheet

PRODUCT DATA. Type channel Human Vibration Front-end Type 1700

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

Gear Transmission Error Measurements based on the Phase Demodulation

Trouble-shooting Radio Links in Unlicensed Frequency Bands TUTORIAL

MEMS On-wafer Evaluation in Mass Production Testing At the Earliest Stage is the Key to Lowering Costs

PRODUCT DATA. Noise Monitoring Terminals Types 3597 C, 3637 A/B and 3631

SOURCE MEASURE UNITS. Make Multiple Measurements Accurately Using a Single Instrument All While Saving Space, Time and Money

Getting Started with the LabVIEW DSP Module

Compensating for speed variation by order tracking with and without a tacho signal

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Ethernet Transmitter Test Application Software TekExpress 10GBASE-T and NBASE-T Datasheet

Real-Time FFT Analyser - Functional Specification

Agilent Spectrum Visualizer (ASV) Software. Data Sheet

Rotating Machinery Analysis

Simplifying DC-DC Converter Characterization using a 2600B System SourceMeter SMU Instrument and MSO/DPO5000 or DPO7000 Series Scope APPLICATION NOTE

Tire Pressure Monitoring Systems and Remote/Passive Keyless Entry

Process Control Calibration Made Easy with Agilent U1401A

Keysight Technologies Phase Noise X-Series Measurement Application

PHASE DEMODULATION OF IMPULSE SIGNALS IN MACHINE SHAFT ANGULAR VIBRATION MEASUREMENTS

Measuring Wireless Power Charging Systems for Portable Electronics

Signal Analysis Techniques to Identify Axle Bearing Defects

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Differential Probes P6248 P6247 P6246 Datasheet

PRODUCT DATA. Laser Doppler Vibrometer Type 8329

Frame through-beam sensors

N9051A Pulse Measurement Software

APPLICATION NOTE. Detecting Faulty Rolling Element Bearings. Faulty rolling-element bearings can be detected before breakdown.

Product Data. Brüel & Kjær B. Artificial Mastoid Type 4930

Techniques to Achieve Oscilloscope Bandwidths of Greater Than 16 GHz

NI 6624 Calibration Procedure

Performing Safe Operating Area Analysis on MOSFETs and Other Switching Devices with an Oscilloscope APPLICATION NOTE

Making a S11 and S21 Measurement Using the Agilent N9340A

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Process Control HPP-25

In-circuit Measurements of Inductors and Transformers in Switch Mode Power Supplies APPLICATION NOTE

THE USE OF VOLUME VELOCITY SOURCE IN TRANSFER MEASUREMENTS

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Isolation Addresses Common Sources of Differential Measurement Error

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

ACOUSTIC NOISE AND VIBRATIONS OF ELECTRIC POWERTRAINS

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Power Analysis Application Module DPO4PWR MDO3PWR Datasheet

Essential Capabilities of EMI Receivers. Application Note

Separation of Sine and Random Com ponents from Vibration Measurements

High-voltage Differential Probes

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

Application Note. Monitoring strategy Diagnosing gearbox damage

Through-beam ring sensors

UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer

Natural Frequencies and Resonance

Measurement Statistics, Histograms and Trend Plot Analysis Modes

NI sbrio-9632/9642 Verification Procedure

m+p Analyzer Revision 5.2

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

An Introduction to Time Waveform Analysis

Using the 4200A-CVIV Multi-Switch to Make High Voltage and High Current C-V Measurements APPLICATION NOTE

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

AC/DC Current Probe TCP0150 Datasheet

Also, side banding at felt speed with high resolution data acquisition was verified.

Evaluating and Optimizing Radio Frequency Identification (RFID) Systems Using Real-Time Spectrum Analysis

Lecture on Angular Vibration Measurements Based on Phase Demodulation

AC Current Probes CT1 CT2 CT6 Data Sheet

Replicating Real World Signals with an Arbitrary/Function Generator

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

Keysight Technologies USB Preamplifiers

Measuring Vgs on Wide Bandgap Semiconductors APPLICATION NOTE

Keysight Technologies Making Fuel Cell AC Impedance Measurements Utilizing N3300A Series Electronic Loads. Application Note

How big is China s Digital Economy

P7600 Series TriMode Probes

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

Machine Data Acquisition. Powerful vibration data collectors, controllers, sensors, and field analyzers

8 Hints for Better Spectrum Analysis. Application Note

Process-Controller HPP-25

Transcription:

APPLICATION NOTE Order Tracking of a Coast-down of a Large Turbogenerator by Svend Gade, Henrik Herlufsen and Hans Konstantin-Hansen, Brüel& Kjær, Denmark In this application note, it is demonstrated how to use the order tracking facility of PULSE, the Multi-analyzer System Type 3560. The data to be analysed is a coast-down of a large turbogenerator in a power station. Critical speeds were confirmed during the measurement. In addition, the 37th order component (and multiples thereof) were identified, caused by loose blades in the cooling fan system. Introduction Analysis of vibration or acoustic signals from rotating machines is often preferred in terms of order spectra rather than frequency spectra. An order spectrum gives the amplitude and/or the phase of the signal as a function of harmonic order of the rotation frequency. This means that a harmonic or sub-harmonic order component remains in the same analysis line independent of the speed of the machine. The technique is called tracking, as the rotation frequency is being tracked and used for analysis. Most of the dynamic forces exciting a machine are related to the rotation frequency so interpretation and diagnosis can thus be greatly simplified by use of order analysis. The classical problem of smearing of the frequency components caused by speed variations of the machine is solved by using order analysis. In situations where the frequency components from a normal frequency analysis are smeared together, proper diagnosis will only be facilitated via order analysis. Of particular interest is the analysis of the vibrations during a run-up or a coast-down of a machine in which case the structural resonances are excited by the fundamental or the harmonics of the rotational frequencies in the mechanical system. Determination of the critical speeds, where the normal modes of the rotating shaft are excited, is very important on large machines such as turbines and generators. 3560/7702

Fig. 1 Contour plot of coast-down using ordinary FFT analysis Use of an FFT analyzer in the normal sampling mode with a fixed sampling frequency (i.e., nontracking) and plotting of the spectrum at certain fixed steps in rotation speed of the machine gives the socalled Campbell diagram. This is a 3-D waterfall type of plot, where vibration levels as a function of frequency are plotted against rotation speed (RPM) of the machine (plotted vertically). This means that the harmonic components appear on radial lines through the point (0 Hz, 0 RPM) while structural resonances appear on vertical straight lines (constant frequency lines). Thus such a plot can be very useful (Fig. 1). The smearing of the components, which appears because the time window used for the individual spectra represents a certain sweep in the speed, is however, a disadvantage. The power of the components becomes spread over several lines. In particular, high frequency components in the spectrum, such as toothmesh frequencies, might be smeared so much that details in sideband structures are lost in the analysis. This is the main reason why order analysis is used instead. For order tracking, the time record is measured in revolutions [REV] rather than seconds [s] and the corresponding FFT spectrum is measured in orders [ORD] rather than frequency [Hz]. Just like the resolution, f [Hz], of the frequency spectrum equals 1/T, where T [s] is seconds per FFT-record, the resolution of the tracked analysis, ord [ORD], equals 1/rev, where rev [REV] is revolutions per FFT-record. For analyses with one or more revolutions per record, the resolution of the spectrum is equal to or better than 1 ORD. The result of the analysis is a high resolution order-spectrum, where the individual orders, or fractions of orders, relate directly to the various rotating parts of the machinery. The focus is on the orders. In general one can say that tracking analysis, by use of an FFT analyzer, is an analysis by which the harmonic pattern of the vibration signal from a rotating machine is stabilised in certain lines independent of speed variations. This means that all the power of a certain harmonic is concentrated in one line and the smearing that would result in normal analysis is avoided. Order Tracking of a Coast-down of a Large Turbogenerator 2 The vibration signals (acceleration) at the bearings of the generator and the turbine were recorded at the same time as was the tacho signal from a Photoelectric Tachometer Probe Type MM 0012 giving the rotation frequency of the shaft. The coast-down lasted nearly 10 minutes and was therefore suitable for order tracking analysis. The lowest 20 harmonics of the vibration signal are analysed during the coastdown. The PULSE setup is shown below and the order spectrum at 2513 RPM in Fig. 2. Setup System Analysis Bandwidth : Auto Order Analyzer Lines : 400

Fig. 2 Order spectrum at 2513 RPM and the measurement setup. Notice only 3 significant orders are seen Order Span: 40 Order dorder : 100m Order Record Size: 10 Rev/Rec Trigger: Free Run Overlap: 66.67 % Averaging: Average Update: New Record Exponential Averaging 20 Tracking: Tracking Mode: Auto Frequency Range: 25.6k Hz Fundamental Frequency Limits: 0 -- 38.4k RPM Tachometer: Tachometer Tacho Signal: Speed (Tacho 1) (0 -- 640 Hz) Vibration 1 Window: Hanning Weighting: None Integration - differentiation: Channel 1 Gain Adjust: 1 Max Input: 5 V (6.667 m/s) None Tachometer Tacho 1 Tacho Detection Slope: Positive Level: -20 % of max input Hysteresis: 20 % of max input Hold Off: 1u sec 40 % of interval Divider: 1 pulses Averager: 5 pulses 3

Tacho Gearing Gearing Select: Ratio 1 1 1 1 Ratio: -- -- -- -- = 1 1 1 1 1 Factor: 1 Combined: 1 Sensitivity: 1 V/V Gain Adjust: 1 Max Input: 5 V (6.667 V) Fig. 3 Order analysis of lower harmonics of generator vibration signal during coastdown Fig. 4 Constant frequency curves A 3-dimensional waterfall plot of the stored spectra of the vertical vibration signal at the generator bearings is shown in Fig. 3. The first 3 harmonics are significant in level and show characteristic resonances. For example, a resonance is seen in the fundamental between 950 RPM and 1050 RPM which evidently is also excited by the second harmonic between 475 RPM and 525 RPM. The constant frequency components, presumably vibrations from other machines transmitted through the foundations, show up on hyperbolic curves in the rotation speed harmonic order plane. The curves are given by c n = f 60, where c is speed in RPM, n is harmonic order and f is the frequency in Hz. Fig. 4 shows some examples of constant frequency curves. Notice the smearing of the constant frequency components. As an overall view of all the related components this plot is very useful. 600 1200 1800 2400 3000 RPM 1 2 3 4 5 Rot. Speed c 6 7 8 9 10 f = 150 Hz f = 50 Hz f = 100 Hz Order No n 810108/2e Using a slice cut (order cut) as shown in Fig. 5 the resonances can be displayed in more detail. It is seen that the resonance around 1000 RPM actually has its peak at 17.44 Hz and is excited by both the fundamental and second harmonic. The broad resonance shape around 1700 RPM in the fundamental is also discernible in the second harmonic. The increased level at 2700 RPM in the fundamental corresponds to a critical speed stated by the manufacturer to be at 45.8 Hz. This resonance is not seen in the second harmonic. In the 1500 3000 RPM range of the second harmonic at 4

least four resonance peaks are seen. Some of these might be combinations of more than one resonance. Fig. 5 Fundamental and second order of generator vibration during coast-down Fig. 6 Nyquist plot of the fundamental of generator vibration during coast-down Acceleration was measured in this example but integrated to velocity. Acceleration is the vibration quantity which puts emphasis on the high frequencies and is thus preferable if it is wanted to raise the higher harmonics relative to the dominating first harmonics. If, however, a measure of the energy in the vibration is desired the velocity should be measured (by integration of acceleration), as the kinetic energy is proportional to velocity squared. Since phase assigned order spectra have been stored in the multi-buffer it is possible to show not only magnitude of orders as a function of RPM but also phase, Bode plots and Nyquist plots. Fig. 6 shows the fundamental order as a Nyquist plot. The cursor is positioned to the same RPM as indicated in Fig. 5. Both real, imaginary and magnitude cursor values can be shown. 5

Fig. 7 Order tracking analysis including 37th order The vibration signal at the generator bearing contained among other components a significant 37th harmonic and harmonics of this. A 3-dimensional plot of a 400 line order analysis up to the 40th harmonic during coast-down is shown in Fig. 7. This component was found to be caused by a fan with 37 blades in the generator cooling system. Some peaks are easily seen. No sideband structure is seen around this component, indicating that it is a rather pure blade-passing frequency without modulation. The fundamental is plotted versus rotation speed in Fig. 8. Peaks showed up in the higher harmonics at nearly the same rotation speeds as in the fundamental. This indicates that the increases are not due to structural resonances, but might be caused by increased turbulence in the blower at different speeds. Fig. 8 Blade-passing frequency (i.e., 37th order) of fan during coast-down Conclusion PULSE, the Multi-analyzer System Type 3560, offers three methods for order analysis: Frequency-based order analysis Order tracking analysis Order tracking filtering The first two methods are in real-time, while the third is a post-processing method. All the methods offer phase assigned orders as output. Frequency-based order analysis using fixed sampling frequency has the advantage of being fast and easy to implement, but it can only be used over a limited RPM range and cannot be used for the accurate extraction of higher orders due to smearing. 6

1 2 3 Signal Processor & IEEE 488 Interface Type 7517 Talk Listen SRQ Trigger Input Sampling Input/Output Power On Off 4 channel Input Type 3022 Input 4 Input 3 Input 2 Input 1 7/6-'89 K B Brüel &Kjær Signal Processor 4 channel Input & IEEE 488 Interface Type 3022 Type 7517 Input 4 Talk Listen SRQ Input 3 Trigger Input Input 2 Input 1 Power Sampling Input/Output On Off 7/6-'89 K B Brüel &Kjær B 7/6-'89 K Order tracking analysis, which uses resampling techniques, is free of smearing and can thus be used for extracting high orders. Implementation is slower due to the more complex calculations involved. PULSE also offers Vold-Kalman order tracking as post-processing on time data. The main advantages of this technique are that there are no slew rate limitations including gear shifts and decoupling of close and crossing orders. Since this is a time-domain based technique, the Vold-Kalman technique also produces order waveform extraction with no time delay, which is very useful for sound quality synthesis and editing. An overview of a complete PULSE-based order analysis system is shown in Fig. 9. Fig. 9 Overview of a 4-channel PULSE system for order analysis Display DSP and Software MS Office NT BZ 5196 Pentium Taxi Interface ZD 0815 Microsoft Windows NT 4.0 BZ 5197 Noise and Vibration Analysis 7700A Keyboard Mouse 1 DSP Board ZD 0812 PULSE Software Order Analysis 7702A Software Maintenance and Upgrade Agreement 7700A-MS1 Frames Taxi Cable AO 0370 Acquisition Front-end 2825 (5 slots) s Signal Analyzer Interface 7521 4-channel Input 3022 Blank Panel FA 1009 Blank Panel FA 1009 Blank Panel FA 1009 Options for 4-channel System Remote Control ZH 0630 RS-232 Data Recorder 7701 incl. Throughput-to-Disk UL 0112 Vold-Kalman Order Tracking Filter 7703 Zwicker Loudness 7704 A Time Capture 7705 DeltaTron Amplifier 2646 Miniature Accelerometer 4397 Miniature Triaxial DeltaTron Accelerometer 4504 Triaxial Accelerometer 4506 DeltaTron Accelerometer 4508 Photoelectric Tachometer Probe MM 0012 Photoelectric Probes MM 0024 DeltaTron Microphone Preamplifier 2671 and Free-field 1/2" Microphone 4189 990014/1e 7

References [1] S. Gade, H. Herlufsen, H. Konstantin-Hansen, N.J. Wismer, Order Tracking Analysis, Brüel & Kjær Technical Review No. 2, 1995 BO 0469 11 99/05 HEADQUARTERS: DK-2850 Nærum Denmark Telephone: +4545800500 Fax: +4545801405 http://www.bk.dk e-mail: info@bk.dk Australia (02)9450-2066 Austria 0043-1-8657400 Brazil (011)5182-8166 Canada (514)695-8225 China (86) 1068029906 Czech Republic 02-67021100 Finland (0)9-755 950 France (01)69906900 Germany 06103/908-5 6 Hong Kong 25487486 Hungary (1)2158305 Ireland (01) 450 4922 Italy (02)57604141 Japan 03-3779-8671 Republic of Korea (02)3473-0605 Netherlands (0)30 6039994 Norway 66771155 Poland (22)8409392 Portugal (1)4711453 Singapore (65) 275-8816 Slovak Republic 421 7 544 307 01 Spain (91)3681000 Sweden (08)4498600 Switzerland 01/9436070 Taiwan (02)7139303 United Kingdom (0181)954-2366 USA 18003322040 Local representatives and service organisations worldwide